Challenge

Identification of Cracks

Question 1:

a)

b)

c)

What is the mode of failure or damage of the beams in the

figure above? Are the damages repairable? Elaborate

ANSWER-

OBSERVATION -

This type of failure occur at bottom to top .

and this faiure looking deep , in there

structure .

--and RCC comes in contact of Air .

AND also increase chances of Corrosion .

conclusions -

-it is a form of flexural failure .

-this failure occur due to reversal

stress of earthquake .

-when earthquake comes , in here

upper part of beam is connected to

slab , so slab provide protection of

upper part of beam ,

-but lower part didnot overcome

these reversable stress effect so

this type failure are take place in

here .

-and Reinforcement seems not

yielded ,

-and permanant and nonrepairable

deformation comes in here .

B)

OBSERVATION -

-

-Shown in here big and deeper crack .

-in here seems to beam is seprated

to column and also deformed .

-and feel like reinforcement is helps

to hold that structure .

-

CONCLUSION -

-When seismic force act, than beam try

to pull themselves out of beam ,

due to less devlopment length ,

provided over in here , so structure fail.

-this failure occured due to very less

devlopment length of RCC bars

-less devlopment lenth and cracks

are wide , open so structural is non

repairable .

C]

OBSERVATION -

-CRacks observed whole beam width

and column

-and cracks observed at joint .

CONCLUSION-

-A high load is acted on beam and column.

--all components try to overcome forces .

-as cracks seems to minor and its a

repairable condition .

Question 2:

a) b) c)

ANSWER

a)

OBSERVATION-

-In here columns seems to damaged

-and no failure comes in beam .

CONCLUSION -

-When Seismic forces is acted ,

than in here plastic hinge may

have been created over there

due to absence of walls .

-that is reason cracks are occured in

there .

-it's looks like not bad but it's

not repairable .

B]

OBSERVATION -

-Cracks are wide and deep

-all Reinforcement visible .

-and look to like shear failure

b)

CONCLUSION-

- basiclly ,when we provided improproper

RCC . calculation , this types

of shear failure comes in our

structures .

-no repairing are done in here .

C] OBSERVATION -

-Wooden piles supported on a slab .

columns seems to completely failed .

-two slabs seems to connected a column

and column is completely failed .

c)

CONCLUSION -

-When we start to design a structure

than proper calcultion according to

type of structure are nessesary ,

but in here design analysis ,

calulation mistake

play important role , so that's a reason

this type of failure will occur .

-i think another reason is that some

platic hinge position , not proper

detailing done , not provided proper

R/F according to demand .

-and surely not repairable.