Steel column design calculator (IS 800:2007 buckling, IS 808 sections)
An ISMB 350 column 5.2 m tall, pinned at the base and moment-connected at the top, has KL/r = 183.1 about its minor axis if nothing restrains it between floors. That is over the IS 800 Table 3 limit of 180, so it fails before load matters. Restrain it at mid-height and KL/r drops to 91.5: fcd = 131.3 MPa and Pd = 876 kN. Run any ISMB, ISHB, ISWB or angle below, free.
IS 800:2007 · IS 808:1989 · 7,096 build-time checks against an independent script · Updated 24 Nov 2026
Section and steel
Ends (IS 800 Table 11)
Moments (factored, end moments M and ψM)
Single angle strut (IS 808 equal angles)
Check my TSD numbers
Uses the section, ends and loads above (moments included). The lightest search runs every ISMB, ISHB and ISWB with the yield stress of its own flange thickness.
| Check (TSD name) | Ratio |
|---|---|
| Axial compression (buckling, 7.1.2) | 0.342 |
| Moment major (8.2.1.2) | 0.301 |
| Moment minor (8.2.1.2) | 0.000 |
| Lateral torsional buckling (8.2.2) | 0.376 |
| Combined, section (9.3.1) | 0.114 |
| Buckling combined (9.3.2.2) | 0.690 |
| Slenderness (Table 3) | 0.509 |
| Family | Lightest passing | kg/m | Governs |
|---|
What is the effective length of a column as per IS 800?
IS 800:2007 clause 7.2.2 gives the effective length KL from the unsupported length L (centre to centre of the members that hold the column in that plane, clause 7.2.1) and the end restraints, in Table 11. Each axis gets its own K: a column can be moment-connected about its major axis and pinned about its minor axis.
| End conditions (Table 11) | KL |
|---|---|
| Both ends fixed, no swaytranslation and rotation restrained at both ends | 0.65 L |
| One end fixed, other pinned, no swayfixed at one end, translation restrained and rotation free at the other | 0.8 L |
| Both ends pinned, no swaytranslation restrained, rotation free at both ends | 1 L |
| One end fixed, other fixed in rotation but free to swayfixed at one end, rotation restrained and translation free at the other | 1.2 L |
| One end pinned, other fixed in rotation but free to swayas drawn in Table 11 (row 2): pinned base, top held against rotation but free to translate | 2 L |
| Cantilever: fixed at one end, free at the otherfixed at one end, translation and rotation free at the other | 2 L |
"No sway" means the far end cannot move sideways because bracing or a stiff core holds it. In the TSD assignment the reports set steel columns pinned at the bottom and fixed at the top (8 reports say so). With the bay braced that is the 0.8 L row; if the frame can sway, a pinned base under a top held only against rotation is the 2.0 L row, two and a half times longer. Choose per axis in the calculator. Clause 7.2.4 gives 0.7 to 1.0 times the length between connections for truss members in the plane of the truss.
What is the buckling class of ISMB, ISHB and angle sections?
Table 10 sets the column curve from the shape. For rolled I-sections it depends on h/bf and the flange thickness:
- h/bf > 1.2, tf ≤ 40 mm: curve a about z-z, b about y-y. Every ISMB, ISWB and ISHB 350 to 450.
- h/bf ≤ 1.2, tf ≤ 100 mm: b about z-z, c about y-y. ISHB 150 to 300 (h/b = 1.0 to 1.2).
- Channels, angles, T and solid sections: c about any axis. Hot-rolled hollow sections: a.
Table 7 gives the imperfection factor for each curve: α = 0.21 (a), 0.34 (b), 0.49 (c), 0.76 (d). A higher α means more residual stress and initial bow, so a lower fcd at the same slenderness.
How do you calculate the design compressive stress fcd?
Clause 7.1.2.1 is a Perry-Robertson formula. With E = 2.0 × 105 MPa and γm0 = 1.10:
For the ISMB 350 column restrained at mid-height about its minor axis (curve b, fy 250 MPa):
About the major axis, 0.8 × 5.2 m over rz = 143 mm is KL/r = 29.1 on curve a: fcd = 220.7 MPa. The smaller value governs. The calculator reproduces all 200 printed cells we typed from IS 800 Table 9 (curves a to d, fy 250 and 360) to the table's rounding; Table 9 has no 350 column, so use the formula, as this tool does, rather than interpolating.
The yield stress itself depends on thickness. IS 800 Table 1 lists IS 2062 E250 at 250 MPa below 20 mm, 240 MPa from 20 to 40 mm and 230 MPa above 40 mm (E350: 350, 330, 320). ISMB 600's 20.3 mm flange takes 240 MPa; the calculator picks it from the flange or leg thickness unless you type your own.
What is the maximum slenderness ratio for a column or a brace (IS 800 Table 3)?
| Member (Table 3) | KL/r max |
|---|---|
| Compression from dead and imposed loads | 180 |
| Compression only from wind or earthquake combinations | 250 |
| Tie in a bracing system, not counted in compression on reversal | 350 |
| Member always in tension | 400 |
| Compression flange of a beam against lateral torsional buckling | 300 |
The 250 row needs the member's deformation not to "adversely affect the stress in any part of the structure". Pre-tensioned bracing need not meet the limits (Table 3 footnote). r is the radius of gyration for the axis of buckling: ry of an I-section, rvv of an angle. For the 5.2 m ISMB 350, the minor axis limits it: 5200 / 28.4 = 183.1 > 180. ISHB 300 over the same height gives 96.1.
What does "buckling combined" mean in Tekla Structural Designer?
It is the member buckling check under axial compression and bending together, IS 800 clause 9.3.2.2. Both equations must be below 1.0. Pdy and Pdz are the buckling strengths about each axis, Mdz includes lateral torsional buckling (8.2.2) over the length between lateral restraints, and the Cm factors come from Table 18 for the moment diagram (linear here; 0.9 for a sway frame):
The section itself is checked by 9.3.1.1 for plastic and compact sections, with the reduced moments of 9.3.1.2(c) for standard I and H sections (semi-compact sections use the linear sum of 9.3.1.3):
For the ISMB 350 column with P = 300 kN and Mz = 60 kN·m (single curvature, ψ = 0), restrained at mid-height: Mdz = 199.3 kN·m, with lateral torsional buckling over 2.6 m Mdz,LT = 159.4 kN·m (λLT = 0.793). Ky = 1.274, KLT = 0.922, and the two equations give 0.690 and 0.435, against an axial ratio of 0.342 and a major-moment ratio of 0.301. That is why a column passes "moment major" and still fails "buckling combined".
The tab's table uses TSD's check names. TSD's own settings (its design code, γ factors, effective lengths, LTB length and Cm) may differ from yours, so a different ratio is a prompt to compare settings, not proof that either is wrong.
When is a column section slender (class 4)?
Table 2 limits the flange outstand b/tf (b = half the flange width) to 15.7ε and the web d/tw to 42ε under axial compression, with ε = √(250/fy). Above that the section is slender and IS 800 sends it to IS 801 or an effective section (3.7.2); this tool flags it and does not design it. Fig. 2 draws d between the flange faces, taken here as D − 2tf with the mean flange thickness, which is conservative. Many textbooks use D − 2(tf + R1), the clear depth between the root fillets, which puts ISMB 450 at 41.0ε instead of 44.2ε.
At E250 that makes ISMB 450, ISMB 500, ISMB 550, ISMB 600, ISHB 450, ISWB 400, ISWB 450, ISWB 500, ISWB 550, ISWB 600 slender in pure compression. At E350 (42ε = 35.5) the ISMB webs from 300 up are slender in pure compression.
Under axial force plus bending Table 2's "Generally" rows apply: 84ε/(1 + r1) for plastic, 105ε/(1 + 1.5r1) for compact (r1 positive) and 126ε/(1 + 2r2) for semi-compact. The print adds "but ≤ 42ε" to each. Read as a cap, that would contradict the table: at r1 = 0 (pure bending) it would give 42ε where the neutral-axis-at-mid-depth row gives 84ε, 105ε and 126ε. Read as a floor, the rows join up: r1 = 0 gives the mid-depth row and r1 = 1 gives 84ε/2 = 42ε, the axial-compression row. The tool uses the floor. Note 5 defines r1 against the web alone and r2 against the whole section, taken here as P/(d tw fy/γm0) and P/(A fy/γm0). On that reading the most slender web here, ISWB 550 (d/tw 49.0), stays semi-compact or better until P reaches 0.78 of A fy/γm0. With no moment, a member is a strut and the 42ε axial row applies, as in the first tab.
ISMB, ISHB or ISWB: which IS 808 section suits a column?
An ISMB is deep and narrow, good for major-axis bending but weak about its minor axis. An ISHB has close to twice the ry of an ISMB of similar weight (54.1 mm for ISHB 300 against 28.4 mm for ISMB 350); an ISWB is in between. For the 5.2 m column carrying 400 kN, restrained at mid-height, the lightest passing sections here are ISMB 225 (31.1 kg/m), ISHB 150 (27.1 kg/m) and ISWB 200 (28.8 kg/m). Without the restraint no ISMB passes: those with ry large enough for KL/r ≤ 180 have class 4 webs.
For a heavier column, 600 kN with Mz = 150 kN·m over a 6.8 m storey with one minor-axis restraint, the lightest ISMB that passes is ISMB 500 (86.9 kg/m). ISHB 400 passes at 77.4 kg/m, 11% lighter, and ISWB 450 at 79.4 kg/m. 9 of 212 reports with text switch members to UK sections (UB 610x305x179, UC 254x254x107 and others) when an ISMB fails, and only 1 mentions ISHB at all. Check the wider IS 808 sections in tab 4 first: they are Indian standard sections, and an ISHB or ISWB that passes keeps the design in IS 808.
Why does a 75x75x8 angle brace fail slenderness?
An angle buckles about its weakest axis, v-v, and rvv of an ISA 75x75x8 is only 14.5 mm (IS 808). KL/r reaches 250, the Table 3 limit for a member in compression only under wind or earthquake, at 3.63 m, and 180 at 2.61 m. The reports name no brace length, so take your own: an X-brace across a 6 m bay and the 5.2 m storey is 7.94 m long, KL/r = 548. To reach 250 at that length you need rvv ≥ 31.8 mm; the first IS 808 angle in this list that gets there is ISA 200x200x16. A brace that only works in tension can be designed as a tie (350), or pre-tensioned.
A single angle bolted through one leg is loaded off its centroid. IS 800 clause 7.5.1.2 covers this with an equivalent slenderness and the constants k1, k2, k3 of Table 12 (bolted ends only):
l is the centre-to-centre length, b1 and b2 the leg widths, and λe goes into the curve c formula. The printed formula shows ε where the modulus E belongs; with E it is the usual non-dimensional slenderness, and it reproduces a worked example (below). For the 75x75x8 at 3 m with two or more bolts and a hinged gusset: λe = 2.002, Pd = 50.7 kN, against 39.0 kN as a concentric strut. Tension yield is Ag fy/γm0 = 259.1 kN (clause 6.2); rupture and block shear need the bolt layout and are not checked here.
What 421 TSD student reports show
Skill-Lync's Tekla Structural Designer course has five assignments on an industrial steel building: the layout and grids, columns, beams and bracings, analysis and design, and the report. We read the text of all 421 public reports on 24 Nov 2026; 82 are image-only (under 150 words of their own), leaving 339 with text. The counts below are "of N reports with text, as of 24 Nov 2026"; most rows use the 212 reports in the column, beam-and-bracing and analysis assignments.
| What the text shows | Reports | Examples |
|---|---|---|
| Names an ISMB (MB) section size | 109 of 212 | 123 |
| Gives a steel column an ISMB size | 49 of 212 | 123 |
| Gives beams or rafters an ISMB size | 91 of 212 | 123 |
| Names an equal-angle (ISA) section for the bracing | 33 of 212 | 123 |
| Switches a member to a UK universal beam or column (UB/UC) | 9 of 212 | 123 |
| Sets steel columns with one end fixed and the other pinned | 10 of 212 | 123 |
| Quotes "moment major" as the failing check | 19 of 212 | 123 |
| Quotes a deflection limit | 10 of 212 | 123 |
| Cites IS 800 (2007) | 11 of 339 | 123 |
| States the TSD design code is Indian | 13 of 339 | 123 |
| States the level heights (5.2 m, 6.8 m, 4.88 m) | 12 of 339 | 123 |
| Moves a member up an ISMB size after a failed check | 16 of 212 | 123 |
| Sets the steel grade to Fe 410 (E 250) | 76 of 339 | 123 |
ISMB 350 is the commonest column (28 of the 49 reports that size a column), and ISA 75x75x8 the usual brace (27 reports). The building's levels are 5.2 m, 6.8 m and 4.88 m. The TSD check named most often as failing is "moment major" (19 reports), then "buckling combined" (5), slenderness (4) and deflection (4). 11 reports cite IS 800, mostly for deflection limits, and none cites a member-check clause or shows a hand check of a column. That is the gap this page fills: the same checks, every factor visible.
Worked example: does the calculator match a published solution?
Bentley publishes IS 800:2007 verification problems for STAAD.Pro with hand solutions. Two are reproduced at build time, using their E = 2.05 × 105 MPa (this page otherwise uses IS 800's 2.0 × 105):
- ISMB 200, 3 m cantilever, 10 kN with 4.5 kN·m about each axis. Major axis λ = 0.402, χ = 0.952, fcd = 216.4 MPa, Pdz = 666.5 kN (printed 0.402, 0.952, 216.4, 666.5); minor axis λ = 1.581, fcd = 71.36 MPa, Pdy = 219.8 kN (printed 1.581, 71.37, 219.8). Mdy = 1.5 Ze fy/γm0 = 9.341 kN·m for a cantilever (printed 9.341). From its printed capacities and Cm = 0.9: Ky = 1.036, Kz = 1.003, KLT = 0.993, section 0.497, equations 0.618 and 0.396 (printed 1.036, 1.003, 0.993, 0.497, 0.618, and 0.397 in the hand solution, 0.396 in STAAD's output). The last digit of fcd differs by 0.01 MPa because STAAD's radii are printed to four figures. STAAD's Mcr uses the torsion and warping constants, not 8.2.2.1, so Mdz is taken from its print.
- ISA 150x115x16, 2.5 m, 100 kN, two bolts, hinged gusset (7.5.1.2). λvv = 1.139, λφ = 0.092, λe = 1.233, fcd = 95.06 MPa, Pd = 380.2 kN, ratio 0.263 (printed 1.139, 0.092, 1.233, 95.06, 380.2 and 0.263).
How we checked the calculator
An independent Python script, scripts/verify/steel_column.py, re-types the clauses: its own Perry-Robertson, Tables 1, 3, 10, 11 and 12, plastic moduli by strip integration, the 9.3.1 and 9.3.2.2 interaction and its own lightest-section search. It checks the 200 Table 9 cells and both worked examples, and that the IS 808 data are self-consistent (r = √(I/A), mass = 7850 A, Z = I/y, Iu + Iv = 2I, all within 1.5 %). This page then runs the browser code on 269 cases (7,096 comparisons) and does not build if any value differs by more than one part in a billion. Two deliberate errors (α for curve b set to 0.35; the Ky cap set to 1 + 0.6 ny) both stopped the build.
Simplifications: plastic moduli from a plate model with the mean flange thickness and no root fillets (1.8 % below the SP 6 value for ISMB 300, so slightly conservative); Mcr by the 8.2.2.1 formula for doubly symmetric sections with normal loading and warping not restrained; minor-axis Mdy capped at 1.2 Ze; Cm only for linear moment diagrams. Not covered: shear and high shear (9.2), class 4 effective sections, built-up and laced columns, base plates and connections, columns in tension with bending (9.3.2.1). Sections are the lightest IS 808 MB, HB and WB of each size and 28 equal angles; the heavier HB and WB of the same depth are not listed.
Column, beam and bracing design for industrial steel buildings is taught in Skill-Lync's steel structures programs, with Tekla Structural Designer and STAAD.Pro.
Frequently asked questions
What is the effective length of a column as per IS 800?
IS 800:2007 Table 11 multiplies the unsupported length L by 0.65 for both ends fixed, 0.8 for fixed and pinned, 1.0 for both pinned, all without sway; 1.2 for fixed with the other end held in rotation but free to sway; 2.0 for a cantilever, or a pinned base with a top held in rotation but free to sway.
What is the buckling class of ISMB, ISHB and angle sections?
IS 800 Table 10: a rolled I-section with h/b over 1.2 and flanges up to 40 mm is class a about the major axis and b about the minor axis, so every ISMB. With h/b up to 1.2, as ISHB 150 to 300, it is b and c. Angles, channels and T-sections are class c about any axis.
How do you calculate the design compressive stress fcd?
Find KL/r, the Euler stress fcc = π²E/(KL/r)², and λ = √(fy/fcc). With α from the buckling class (0.21, 0.34, 0.49, 0.76), φ = 0.5[1 + α(λ − 0.2) + λ²] and fcd = (fy/1.1)/(φ + √(φ² − λ²)). ISMB 350 at KL/r 91.5 about its minor axis gives 131.3 MPa.
What is the maximum slenderness ratio for a compression member and a bracing?
IS 800 Table 3: 180 for a member carrying dead and imposed load in compression; 250 for a member in compression only under wind or earthquake combinations, which covers most wall and roof bracing; 350 for a bracing tie not counted in compression; 400 for a member always in tension.
What does buckling combined mean in Tekla Structural Designer?
It is the member buckling check under axial force and bending together: IS 800 clause 9.3.2.2's two interaction equations, which add P/Pd for buckling to both moment ratios, scaled by the Ky, Kz and KLT factors and the equivalent moment factors Cm. A ratio above 1.0 fails, even when each check passes alone.
ISMB or ISHB: which is better for a steel column?
For a column, the minor axis usually governs. ISHB 300 has ry = 54.1 mm against 28.4 mm for ISMB 350, so the same storey height gives about half the slenderness. ISMB carries moment well about its major axis, so it suits beams and moment-frame columns with restraint about the minor axis.
Why does a 75x75x8 angle brace fail slenderness?
Its smallest radius of gyration, about the v-v axis, is 14.5 mm. KL/r reaches the Table 3 limit of 250 at 3.63 m and 180 at 2.61 m. A diagonal across a 6 m bay and a 5.2 m storey is 7.94 m long, about twice what a 75x75x8 can span.
Is this steel column calculator free?
Yes. It runs in your browser with no sign-up. Every number is recomputed at build time against an independent Python script that re-types the IS 800 clauses and 200 printed cells of Table 9 (7,096 comparisons), and the page does not build if any value differs.
Related on Skill-Lync
- Steel structure load calculator (the wind, dead and live loads that make P and M)
- Load combination generator (which combination gives the column its worst P and M)
- Gantry girder design calculator (crane columns carry its reactions)
- Weld strength calculator (base and bracing connections)
- Structural design courses compared
- All free engineering tools
Sources
- Bureau of Indian Standards, IS 800:2007 General construction in steel (public copy, archive.org): Table 1, 3.7, Table 2, Fig. 2, 3.8, Table 3, 6.2, 7.1.2, 7.1.2.1, Table 7, Table 9, Table 10, 7.2, Table 11, 7.5.1.2, Table 12, 8.2.1.2, 8.2.2, 8.2.2.1, 9.3.1.1-9.3.1.3, Table 17, 9.3.2.2, Table 18.
- IS 808:1989 Dimensions for hot rolled steel beam, column, channel and angle sections (law.resource.org): Tables 2.1 (MB), 2.2 (WB), 3.1 (HB), 5.1 (equal angles) and Amendment 1.
- Bentley Systems, STAAD.Pro verification problems "IS 800 2007 LSD - I Section - with LTB" and "IS 800 2007 LSD - Angle - Flexural Torsional Buckling" (docs.bentley.com).
- S. R. Satish Kumar and A. R. Santha Kumar, IIT Madras, NPTEL Design of Steel Structures, industrial building example (ISMB 300 plastic modulus).
- Skill-Lync, the 421 public student reports of the Tekla Structural Designer industrial steel assignments, read 24 Nov 2026.