Load combination generator for RCC buildings: IS 456, IS 875 and IS 1893

An RCC building with dead, live and earthquake load in X and Y needs 13 limit state combinations: 1.5 (DL + LL), then 1.2 (DL + LL ± EL), 1.5 (DL ± EL) and 0.9 DL ± 1.5 EL for EQx and EQy with both signs (IS 456 Table 18, IS 1893 (Part 1):2016 clause 6.3). Live load never takes a minus sign.

This generator lists them for your load cases, with or without the 100 % + 30 % rule, as text for STAAD, ETABS or Robot. It also finds the governing combination for a member, checks storey drift against 0.004 h and checks a list you typed. Free, in your browser.

IS 456:2000 Table 18 (Amendment 1) · IS 875 (Part 5):1987 clause 8.1 · IS 1893 (Part 1):2016 clauses 6.3, 7.11.1 (Amendments 1, 2) · checked against an independent solution (2,908 checks at build) · Updated 24 Nov 2026

Which load combinations does my building need, numbered and ready to paste into the software?

Primary load cases
Options

Roof imposed load (RLL) takes the same factor as floor LL in every combination (IS 456 Table 18 has one IL column). For the seismic weight itself IS 1893 7.3.2 says imposed load on the roof need not be considered. Temperature (IS 875-5 8.1 e to n) and vertical earthquake (IS 1893 6.3.3, 6.3.4) are not generated.

Strength (limit state of collapse)13combinations
Serviceability0combinations
Primary cases4DL, LL, EQx, EQy
    No.CombinationFactorsCheckClause
    11.5 (DL + LL)1.5 DL + 1.5 LLstrengthIS 456 Table 18 (DL + IL)
    21.2 (DL + LL + EQx)1.2 DL + 1.2 LL + 1.2 EQxstrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    31.2 (DL + LL − EQx)1.2 DL + 1.2 LL − 1.2 EQxstrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    41.2 (DL + LL + EQy)1.2 DL + 1.2 LL + 1.2 EQystrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    51.2 (DL + LL − EQy)1.2 DL + 1.2 LL − 1.2 EQystrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    61.5 (DL + EQx)1.5 DL + 1.5 EQxstrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    71.5 (DL − EQx)1.5 DL − 1.5 EQxstrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    81.5 (DL + EQy)1.5 DL + 1.5 EQystrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    91.5 (DL − EQy)1.5 DL − 1.5 EQystrengthIS 1893 6.3.2.1; IS 456 Table 18, Note 1
    100.9 DL + 1.5 EQx0.9 DL + 1.5 EQxstrengthIS 1893 6.3.2.1; IS 456 Table 18, 0.9 footnote
    110.9 DL − 1.5 EQx0.9 DL − 1.5 EQxstrengthIS 1893 6.3.2.1; IS 456 Table 18, 0.9 footnote
    120.9 DL + 1.5 EQy0.9 DL + 1.5 EQystrengthIS 1893 6.3.2.1; IS 456 Table 18, 0.9 footnote
    130.9 DL − 1.5 EQy0.9 DL − 1.5 EQystrengthIS 1893 6.3.2.1; IS 456 Table 18, 0.9 footnote
    COMB1 = 1.5 DL + 1.5 LL
    COMB2 = 1.2 DL + 1.2 LL + 1.2 EQx
    COMB3 = 1.2 DL + 1.2 LL - 1.2 EQx
    COMB4 = 1.2 DL + 1.2 LL + 1.2 EQy
    COMB5 = 1.2 DL + 1.2 LL - 1.2 EQy
    COMB6 = 1.5 DL + 1.5 EQx
    COMB7 = 1.5 DL - 1.5 EQx
    COMB8 = 1.5 DL + 1.5 EQy
    COMB9 = 1.5 DL - 1.5 EQy
    COMB10 = 0.9 DL + 1.5 EQx
    COMB11 = 0.9 DL - 1.5 EQx
    COMB12 = 0.9 DL + 1.5 EQy
    COMB13 = 0.9 DL - 1.5 EQy

    Generic text: type one line per combination, signs as written.

    What load combinations does an RCC building need?

    IS 875 (Part 5):1987 clause 8.1 lists which loads act together (DL, DL + IL, DL + EL, DL + IL + EL ...) and sends you to the design code for the factors. For reinforced concrete that is IS 456:2000 Table 18, and IS 1893 (Part 1):2016 clause 6.3 adds the earthquake sets. With one earthquake load EL:

    Each EL stands for EQx and EQy separately, each with + and −, because the ground shakes both ways (clause 6.3.2.1: one horizontal direction at a time for frames along two orthogonal directions). Wind takes the same factors with WL for EL. The count follows from the structure of the list:

    So dead, live and earthquake in X and Y give 13 strength combinations; add wind in X and Y and you get 25. With only EQx and one sign you would have 4, which is why a two-line list cannot be complete. The serviceability set (Table 18 columns 5 to 7: DL + LL, DL ± EL, DL + 0.8 LL ± 0.8 EL) adds 9 more for deflection and crack checks.

    Why does 0.9 DL − 1.5 EL govern at a beam end?

    Take the support of a first-floor beam in the X frame of a G+3 building (illustrative numbers, made up for this page): DL −60 kN·m, LL −30 kN·m (hogging), EQx ±70 kN·m from sway. The envelope of the 13 combinations:

    The largest hogging moment comes from 1.5 (DL − EQx), more than 1.5 (DL + LL) = -135 kN·m. The reversal case 0.9 DL + 1.5 EQx turns the support moment positive: the beam needs bottom steel at the support, which a gravity-only list never shows. At midspan the earthquake moment is small and 1.5 (DL + LL) = 90 kN·m governs. In a corner column (DL 600, LL 200, EQx ±180 kN), 1.2 (DL + LL + EQx) gives the most compression, 1,200 kN, and 0.9 DL − 1.5 EQx the least, 270 kN. Tab 2 draws all three.

    What is the 100-30 rule for earthquake load?

    IS 1893 clause 6.3.2.2 applies when the lateral load resisting elements are not oriented along two mutually orthogonal directions (Table 5 (v), as amended): design for full earthquake in one direction plus 30 % in the other, with every sign:

    Each EL becomes eight effects instead of four, so the strength list grows from 13 to 25. For a regular frame with columns and beams on two orthogonal grids, clause 6.3.2.1 takes one direction at a time and the 30 % sets are not required. When vertical shaking must be included (clause 6.3.3.1 as amended: Zone IV or V, irregular buildings, soft soil, long spans, large overhangs), clause 6.3.4.1 adds ±0.3 ELz to each set; this generator does not.

    What is the storey drift limit in IS 1893:2016?

    Clause 7.11.1.1: "Storey drift in any storey shall not exceed 0.004 times the storey height, under the action of design base shear VB with no load factors mentioned in 6.3, that is, with partial safety factor for all loads taken as 1.0." Storey drift is the relative displacement between the floors above and below (clause 4.21):

    The design force already carries R: Ah = (Z/2)(Sa/g)/(R/I), clause 6.4.2. The code multiplies displacements by R only where it says so, for members outside the lateral system (7.11.2) and for the gap between adjacent buildings (7.11.3), so the 0.004 check uses the displacements as analysed. Since Amendment 2, displacements from dynamic analysis need not be scaled up to the static base shear (7.11.1.2). A soft storey has its own, tighter 0.2 % limit: see the building irregularity checker.

    How do you enter load combinations in STAAD, ETABS and Robot?

    STAAD.Pro. The LOAD COMBINATION command (Technical Reference TR.35) takes a number, any title, then pairs of load case number and factor: LOAD COMBINATION 6 DL+LL+WL / 1 0.75 2 0.75 3 1.33 in Bentley's own example. The number must be below 100,000 and differ from every primary load case. TR.35 says "Values greater than or equal to 0.0 are allowed" for the factors, so the STAAD text here gives each sign of a lateral case its own primary load (EQ +X, EQ −X) and keeps every factor positive. A LOAD COMBINATION adds results; it is not re-analysed, so for P-delta use REPEAT LOAD instead.

    Robot Structural Analysis. Autodesk's help generates code combinations from the code chosen under Tools > Job Preferences > Design codes > Loads, with Loads > Automatic Combinations, and lets you "define the action combinations manually, one by one". Autodesk's list of codes in Robot 2023 names IS 456:2000 for concrete design, IS 875 (Part 3_4) for snow and wind, and IS 1893-2002 for seismic loads; it does not say which Indian combination rule the automatic set follows. Enter the list above as manual combinations, from the table copy.

    ETABS. Define one load case per direction (EQx, EQy, WLx, WLy) and type each combination as a linear add with the signed factors of the table copy.

    What 209 Robot structural analysis reports did (as of 24 Nov 2026)

    We read the 209 public Skill-Lync reports of the Robot Structural Analysis building project (BIM in AEC Industry using Revit), as of 24 Nov 2026, n = 209. 2 are image-only, with little text, so counts are of the 207 that can be read. Results sit mostly in screenshots, so a count of 0 means none typed it, not that none computed it. The links are examples.

    • 58 / 207Write the combinations out with numeric factors. report 1report 2
    • 97 / 207Mention combinations but write no factors.
    • 57 / 207Name an earthquake load.
    • 81 / 207Name a wind load.
    • 14 / 207Cite IS 456. report 1report 2
    • 4 / 207Cite IS 875.
    • 2 / 207Cite IS 1893.
    • 191 / 207Cite no design code at all.
    • 54 / 207Say the supports are fixed. report 1report 2
    • 151 / 207Do not state the supports.
    • 0 / 207Type a maximum moment or displacement number (results sit in screenshots).
    • 0 / 207Compute storey drift or compare it with 0.004.

    The most common combinations written out, counted once per report:

    As writtenReportsChecker
    1.5DL+1.5LL20in the codes
    1DL±1.5LL15not as written in the codes
    0.9DL±1.5EL10in the codes
    1DL+1.5LL8not as written in the codes
    1.5(DL+LL)8in the codes
    1.25DL+1.5LL+1.75WL5not as written in the codes
    1.25DL+1.5LL4not as written in the codes
    1.2(DL+LL+WL)3in the codes

    Of the 58 reports that write combinations with factors:

    • 15 / 58Give the live load a ± sign ("1DL ± 1.5LL"): live load does not reverse. report 1report 2
    • 19 / 58Name an earthquake load but put it in no combination. report 1report 2
    • 3 / 58Write earthquake combinations with + only, no reversed case. report 1report 2

    No report types a storey drift or compares one with 0.004, though the task asks for lateral displacement under every lateral combination. Many reports share near-identical text, so these counts reflect a shared answer as much as separate choices. They are first-party counts, a starting point rather than a measure of ability.

    How we checked the generator

    An independent Python script, scripts/verify/load_combinations.py, rebuilds every list from the clause text with its own code, including hand-written lists for five case sets and a closed-form count for every option set. This page refuses to build if the browser code differs from it in any combination, factor, clause, line of STAAD or table text, envelope value, drift verdict or checker flag: 2,908 checks over 331 cases, plus 5,426 checks inside the script. The cases cover no earthquake, wind only, both, 100-30 on and off, signs off, a single storey, a drift of exactly 0.004 h, a zero storey height, and 59 typed lines and lists. Two deliberate bugs, a 1.5 instead of 1.2 on the combined case and a dropped 30 % companion, each make the build fail.

    What this generator does not cover

    • Temperature, snow, cranes, vertical earthquake. IS 875-5 8.1 also combines temperature load; snow replaces imposed load on roofs (Note 1); vertical shaking follows IS 1893 6.3.3 and 6.3.4.
    • Pattern loading and reduced imposed load. IS 456 22.4.1 puts the imposed load on two adjacent spans and on alternate spans (on all spans if it is at most three-fourths of the dead load); IS 875-5 says reduced imposed load should not be used with earthquake. Model those in your analysis.
    • Foundations and stability. Soil pressure uses unfactored loads (IS 1893 6.3.5.1); overturning and sliding have their own factors (IS 875-5 Notes 4 and 5).
    • Steel and other codes. IS 800 Table 4, Eurocode and ASCE 7 have different factors. The checker flags factors such as 1.25 DL or 1.75 WL as not in IS 456, whatever their source.
    Learn building analysis

    The Robot structural analysis of a Revit building model is a project in Skill-Lync's BIM in AEC Industry using Revit course; ETABS and STAAD.Pro building design have their own courses.

    Frequently asked questions

    What load combinations are used for an RCC building as per IS 456 and IS 1893?

    IS 456 Table 18 and IS 1893 (Part 1):2016 clause 6.3 give 1.5 (DL + LL), 1.2 (DL + LL ± EL), 1.5 (DL ± EL) and 0.9 DL ± 1.5 EL. With earthquake in X and Y, each with both signs, that is 13 limit state combinations. Wind takes the same factors, never together with earthquake.

    How many load combinations are needed in ETABS, STAAD or Robot?

    For dead, live and earthquake in two directions: 13 for strength, plus 9 for serviceability if you check deflection and cracking. Adding wind in X and Y makes 25. With the 100 % + 30 % rule for earthquake it is 25, or 37 with wind as well. The software only adds them; the list comes from the code.

    Why is 0.9 DL + 1.5 EL used?

    Dead load usually helps resist uplift, overturning and moment reversal. IS 456 Table 18 takes 0.9 on DL when stability against overturning or stress reversal is critical, so the least likely dead load meets the full earthquake or wind. It governs column tension, footing uplift and bottom steel at beam ends.

    What is the 100-30 rule in IS 1893?

    Clause 6.3.2.2: when the lateral load resisting elements are not along two orthogonal directions, design for full earthquake in one direction plus 30 % in the other, both signs: ±ELx ± 0.3 ELy and ±ELy ± 0.3 ELx. For orthogonal frames, 6.3.2.1 takes one direction at a time.

    What is the storey drift limit as per IS 1893:2016?

    Clause 7.11.1.1: storey drift in any storey shall not exceed 0.004 times the storey height, under the design base shear with every load factor taken as 1.0. For a 3 m storey that is 12 mm between the floor below and the floor above. The displacements are not multiplied by R for this check.

    Why is live load never taken as negative in a load combination?

    Live load is gravity: people and furniture push down and cannot pull up. Earthquake and wind change direction, so they take ±. Writing 1.0 DL − 1.5 LL models a floor load acting upwards, which no code lists. The reversal case you need is 0.9 DL ± 1.5 EL, with no live load at all.

    Are wind and earthquake loads combined together?

    No. IS 1893 clause 6.2 (b) says an earthquake is not likely to occur together with high wind, and IS 875 (Part 5) clause 8.1 says maximum wind, earthquake and imposed loads are not likely to occur together. Make separate wind and earthquake combinations with the same factors and design for the worse one.

    What is the difference between IS 875 Part 5 and IS 1893 load combinations?

    IS 875 (Part 5):1987 clause 8.1 lists which loads act together (DL + IL + EL and so on) without factors, and tells you to follow the design code. The factors come from IS 456 Table 18 for concrete, and IS 1893 clause 6.3 adds the earthquake sets. They do not conflict: the design codes govern.

    Related on Skill-Lync

    Sources

    Free counselling

    From load cases to a building you can analyse and design.

    Structural design roles want engineers who can set up loads, combinations and drift checks in ETABS, STAAD.Pro or Robot and defend them against the code. A Skill-Lync counsellor can map the course that fits your background.

    Talk to a structural design course counsellor

    Free. We call you back, usually the same day.

    By submitting you agree to our Terms and Privacy Policy.

    Talk to a career counsellor

    Talk to a career counsellor

    Free 20-minute call. We'll map the right course to where you want to work.

    By submitting you agree to our Terms and Privacy Policy.