Weld strength calculator
Check a fillet or butt weld in seconds: throat thickness, effective length, stress, design strength and pass or fail, under IS 800:2007, AISC 360-16 or your textbook's allowable stress. It also handles welds loaded off-centre (brackets, in plane or bending) and checks the minimum and maximum weld size. Free, no sign-up, nothing leaves your browser.
IS 800:2007 cl. 10.5 · AISC 360-16 J2 · elastic method for weld groups · worked examples verified by script · Excel version · Updated 16 Nov 2026
Complete penetration butt weld, IS 800:2007 10.5.7.1.2: checked as parent metal with throat = thinner part. The code selector does not apply.
Factored load for IS 800 and LRFD; service load for ASD and allowable stress.
How do you calculate fillet weld strength?
A fillet weld fails in shear across its throat, the shortest line from the root to the face. So its strength is throat area times design shear strength. Throat area = throat × effective length; for a normal 90° fillet the throat is 0.7 × leg size. Compare the stress P/(throat × length) with the code's strength.
Three things change from code to code: the throat factor, how much length counts, and the strength. In IS 800:2007 they are:
- Throat: K × size, with K from Table 22 (0.70 for fusion faces at 60° to 90°, falling to 0.50 at 120°). The throat must be at least 3 mm.
- Length: only the full-size length counts. Draw the weld 2 × size longer than the design length, and never shorter than 4 × size (clause 10.5.4.1).
- Strength (clause 10.5.7.1.1), with fu the smaller of the weld metal and parent metal ultimate stress, and γmw = 1.25 for shop welds or 1.50 for site welds (Table 5):
What is the design strength of a fillet weld as per IS 800?
For E250 steel welded with EX40XX electrodes (both fu = 410 N/mm²), fwd = 189.4 N/mm² for a shop weld and 157.8 N/mm² for a site weld. A site weld gets 1.50 instead of 1.25 because welding on site, often overhead, is harder to control. For E350 steel the electrode decides:
| Parent steel (IS 2062) | Electrode (IS 814) | fu used | Shop fwd | Site fwd |
|---|---|---|---|---|
| E250 (Fe 410) | EX40XX (fu 410) | 410 | 189.4 | 157.8 |
| E350 (Fe 490) | EX40XX (fu 410) | 410 | 189.4 | 157.8 |
| E350 (Fe 490) | EX50XX (fu 510) | 490 | 226.3 | 188.6 |
With an EX40XX electrode on E350 plate, the weaker weld metal governs and you get no benefit from the stronger steel. Joints longer than 150 × throat (long splices, end connections) are reduced further by clause 10.5.7.3:
Worked example 1: a tie lapped on a gusset, shop vs site
A 10 mm flat tie of E250 steel is lapped on a 12 mm gusset and joined by two side fillet welds, 6 mm, each 210 mm long as drawn. Factored tension: 300 kN. Minimum size by Table 21 (thicker part 12 mm): 5 mm. Maximum on the square edge of the 10 mm plate: 10 − 1.5 = 8.5 mm. So 6 mm is allowed.
Shop weld: capacity 1663.2 × 189.4 = 315.0 kN ≥ 300 kN. Pass, at 95% utilisation. Same joint welded on site: 262.5 kN, which fails. Each run would have to be 238.3 mm as drawn (say 240 mm), or the weld one size bigger. Moving a weld from the shop to the site is a design change, not a detail.
The joint length (210 mm) is well under 150 × 4.2 = 630 mm, so no long-joint reduction. For comparison, AISC 360-16 with E70 electrodes (FEXX = 70 ksi = 482.6 N/mm²), 0.707 throat and full length gives φRn = 386.9 kN (LRFD) or Rn/Ω = 258.0 kN (ASD, against service load). That is not "AISC is stronger": its electrode is stronger and its load factors are different.
How does AISC 360 calculate fillet weld strength?
AISC 360-16 (section J2.4) takes the nominal stress on the effective throat as 0.60 FEXX, with φ = 0.75 for LRFD or Ω = 2.00 for ASD. For E70 electrodes that is 217.2 N/mm² (LRFD) or 144.8 N/mm² (ASD). Unlike IS 800, AISC credits a load at an angle to the weld:
A transverse weld (θ = 90°) gets 1.5 times the strength, 325.8 N/mm² LRFD, because tests show it. The effective throat is 0.707 × leg for an equal-leg fillet. Minimum sizes (Table J2.4) go by the thinner part: 3 mm up to 6 mm, 5 mm to 13 mm, 6 mm to 19 mm, 8 mm above. Along a plate edge 6 mm or thicker, the weld is at most thickness − 2 mm.
How do you calculate weld strength under eccentric loading?
Treat each weld as a line, find the centroid G of the group, and move the load there: a direct force P plus a twisting moment P × e. The direct force spreads evenly over the welds. The moment adds a shear that grows with the distance r from G and acts at right angles to r. Add the two as vectors where they are largest.
Ju is the polar moment of the weld lines per unit throat. For the common shapes (our verifier checks each formula against numeric integration of the lines):
| Weld group | Length Lw | x̄ from left line | Ju (in plane) | Iu (bending) |
|---|---|---|---|---|
| Two vertical lines (b apart, each d long) | 2d | b/2 | d(3b² + d²)/6 | d³/6 |
| Two horizontal lines (b long, d apart) | 2b | b/2 | b(b² + 3d²)/6 | bd²/2 |
| C: one vertical d + two horizontal b | 2b + d | b²/(2b + d) | (8b³ + 6bd² + d³)/12 − b⁴/(2b + d) | d³/12 + bd²/2 |
| Box, all round | 2(b + d) | b/2 | (b + d)³/6 | d²(3b + d)/6 |
The most stressed point is always a corner of the group (the resultant grows steadily along a straight weld), on the side towards the load. The calculator checks every corner.
Worked example 2: bracket plate with a C-shaped weld
A bracket plate is welded to a column flange on three sides: a vertical weld d = 200 mm and two horizontal welds b = 100 mm. A factored load of 80 kN acts 300 mm from the vertical weld. Weld: 6 mm shop fillet, fwd = 189.4 N/mm².
The 6 mm weld fails at 129% utilisation. Because every stress scales with 1/throat, the size needed is 6 × 1.29 = 7.7 mm, so use 8 mm: τR = 182.9 N/mm², 97%. Notice the twisting part (212.4 N/mm²) is 4.5 times the direct shear (47.6): for brackets, the eccentricity is the design.
The elastic method is conservative. AISC also allows the instantaneous centre of rotation method (its Manual tables), which typically gives a higher capacity for the same weld.
How do you check a weld in bending?
When a bracket is welded to a column face and the load acts away from that face, the welds carry a bending moment P × e about a horizontal axis plus the vertical shear P. The bending stress is largest at the top of the weld; the shear is spread over the total length. IS 800:2007 combines them as an equivalent stress (Iu = d³/6 is for two vertical weld lines; the table above has the box):
Clause 10.5.10.1.2 waives this check when fa + q ≤ fwd. Machine design textbooks and the AISC elastic method instead add the two stresses as vectors, √(fa² + q²), and compare with the allowable shear. The calculator shows both.
Worked example 3: bracket on a column with two vertical welds
Two vertical 8 mm shop fillet welds, each d = 250 mm, carry a factored 100 kN at e = 200 mm from the column face. Iu = d³/6 = 26,04,167 mm³, throat 5.6 mm.
fa + q = 207.1 > 189.4, so the combined check is needed:
Pass at 96%. The vector resultant is 175.1 N/mm². Bending dominates: doubling the weld depth to 500 mm would cut fa by 4 times, while a bigger weld size only helps linearly.
How strong is a butt weld?
A complete penetration butt weld is as strong as the plate. IS 800:2007 (clause 10.5.7.1.2) treats it as parent metal with a thickness equal to the throat. The throat is the thinner plate's thickness (clause 10.5.3.3). So check tension against fy/γm0 and shear against fy/(√3 γm0), with γm0 = 1.10.
For a 10 mm E250 plate that is 227.3 N/mm² in tension and 131.2 N/mm² in shear. A partial penetration weld counts only the weld metal common to both parts, without the reinforcement (the cap).
Weld strength calculation in Excel
The same calculations come as an Excel workbook. It has four sheets: fillet direct load, butt weld, eccentric in plane, and bending. Inputs are in yellow cells, formulas are visible, and each line cites its IS 800 clause. The defaults are the three worked examples above, so you can check it against this page before using it. We recalculated every result cell in LibreOffice and compared it with our verifier.
What this calculator does not cover
- Fatigue. Welds under repeated loads (cranes, vehicle frames, rotating machines) usually fail by fatigue at the toe far below these static strengths. Use the detail categories of IS 800 section 13 or IIW / EN 1993-1-9.
- The parts being joined. The plate, gusset or column flange next to the weld must be checked too (block shear, yielding, local bending).
- The instantaneous centre method (AISC) for eccentric groups: it gives higher capacities than the elastic method used here.
- Weld quality. Undercut, porosity and lack of fusion reduce strength. The codes assume welds made and inspected to IS 816 / AWS D1.1.
Use the results to size and check welds while learning or in early design. Have connection designs that someone relies on reviewed against the governing code by a qualified engineer.
Skill-Lync's courses teach weld and connection design on real structures and fixtures, the way design interviews ask it.
- Structural Steel Connection Design (11 weeks: welded and bolted connections to code)
- Post Graduate Program in Steel Structure Design
- BIW Fixture Design using CATIA V5 (12 weeks: weld fixtures for car bodies)
- Post Graduate Program in CAD (mechanical design)
Frequently asked questions
How do you calculate the strength of a fillet weld?
Multiply the throat thickness by the effective length to get the throat area, then multiply by the design shear strength. Throat = 0.7 × leg size for a normal 90° fillet. Under IS 800:2007 the strength is fu/(√3 × 1.25) for shop welds, 189.4 N/mm² for E250 steel and EX40XX electrodes. Strength (N) = 0.7 × s × length × 189.4.
What is the throat thickness of a fillet weld?
The throat is the shortest distance from the root to the face of the weld, where it fails in shear. For an equal-leg fillet between faces at 60° to 90°, IS 800:2007 Table 22 takes it as 0.70 × leg size. AISC uses 0.707 × leg, from the 45° geometry. For faces up to 120° apart, K falls to 0.65, 0.60, 0.55 and 0.50.
What is the design strength of a fillet weld as per IS 800?
IS 800:2007 clause 10.5.7.1.1 gives fwd = fu/(√3 γmw), with fu the smaller of weld and parent metal strength and γmw = 1.25 for shop welds or 1.50 for site welds. For E250 steel (fu 410 N/mm²) that is 189.4 N/mm² in the shop and 157.8 N/mm² on site.
Why is 2 × weld size subtracted from the fillet weld length?
The start and end of a weld run are not full size: craters and the arc start leave a short length with a reduced throat. IS 800:2007 clause 10.5.4.1 therefore counts only the full-size length, so the drawn length must be the design length plus twice the weld size, and never less than four times the size.
How do you calculate weld stress under eccentric loading?
Split the load into a direct force through the weld group centroid and a moment P × e. The direct force gives a uniform shear P/(throat × total length). The moment gives a shear P·e·r/(throat × Ju) at distance r, at right angles to r. Add the two as vectors at the corner farthest from the centroid on the load side.
What is the minimum size of fillet weld as per IS 800?
IS 800:2007 Table 21 sets it by the thicker part joined: 3 mm up to 10 mm, 5 mm over 10 to 20 mm, 6 mm over 20 to 32 mm and 10 mm over 32 to 50 mm (8 mm for the first run). If that exceeds the thinner part, the thinner part's thickness governs, with preheating. No fillet weld may be under 3 mm.
Is a transverse fillet weld stronger than a parallel fillet weld?
Yes, tests show about 1.5 times. AISC 360-16 allows it through the factor (1 + 0.5 sin^1.5 θ), which is 1.5 for a load at 90° to the weld. IS 800:2007 does not: it uses the same fwd for both, which is conservative. Many machine design textbooks check transverse welds in tension and parallel welds in shear, both on 0.707 × leg.
Can I download this weld strength calculator in Excel?
Yes. The Excel workbook has the same four calculations (fillet direct load, butt weld, eccentric in-plane, bending), live formulas you can read and edit, and the worked examples on this page as default inputs. It is free; fill in the short form on this page and the download link appears immediately.
Related on Skill-Lync
- All free design and quality tools
- Student project: weld strength calculation using an Excel sheet
- Weldments in SOLIDWORKS
- Types of steel structural connections
- DFM checklist with sheet metal, moulding and CNC rule calculators
- Tolerance stack-up calculator
Sources
- IS 800:2007, General Construction in Steel: Code of Practice (BIS), clause 10.5 (welds: 10.5.2 size and Table 21, 10.5.3 throat and Table 22, 10.5.4 effective length, 10.5.7 design stresses, 10.5.7.3 long joints, 10.5.8 edges, 10.5.9-10.5.10 stresses and combination) and Table 5 (γmw); Table 1 for IS 814 electrodes and IS 2062 steels. Read in the code text, 16 Nov 2026.
- AISC 360-16, Specification for Structural Steel Buildings, section J2 (effective throat, Table J2.4 minimum sizes, J2.4 directional strength, Table J2.5 φ and Ω).
- Shigley's Mechanical Engineering Design, tables of torsional and bending properties of fillet welds (unit-throat method).
- Worked examples and all their numbers: Skill-Lync, recomputed by scripts/verify/weld.py (pure Python; 100 weld-group property cases checked by numeric integration and 240 load cases confirming the critical corner) and cross-checked against this page's calculator code at build time. Example loads are illustrative.