Tekla Structural Designer projects and load calculations

13 Tekla Structural Designer (TSD) projects that Skill-Lync learners have actually done, 980 public reports in all: an industrial steel building from grids to design, an RC building with IS 1893 seismic loads and piles, a 10 t crane shed and an RC office. Each has the challenge inputs, real reports and a way to take it further.

As of 20 Nov 2026: 980 of 1,41,067 public learner reports match one of these ideas · Counts are reports, not unique students

How to pick one

  1. Do every load by hand once. The wind, dead and seismic challenges ask for a manual calculation before the wizard. Keep that sheet: when the software and your hand numbers differ, finding out why is the most useful hour of the course.
  2. Check the model before the design. Validate the model, then compare the total vertical reaction with your hand take-down of dead and imposed load. If they disagree by more than a few percent, a load is missing or applied twice, and no design result after that can be trusted.
  3. Finish with drawings and a report. Both course projects end in member reports and drawings (plans and beam reinforcement). That is what a design office looks at in a portfolio, not screenshots of a 3D model.

Industrial steel building, week by week

One steel building carried from grid lines to a checked design: pedestals, columns, beams and bracing, dead, live and wind loads, analysis and design.

Plan the structural layout and set up grids from architectural drawings

BeginnerTekla Structural Designer101 reports

Week 1 is the workspace: the project workspace, scene content, two scene views, the loading drop list and the properties window. Then you read the architect's plan and section, decide where columns and beams can go, and set construction levels and grid lines for the steel building you keep for the next five challenges.

Make it a final-year project: Before touching the software, sketch the column grid by hand and mark which bays are braced and which are moment frames. Compare your sketch with the final model at the end.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Model concrete pedestals and steel columns

BeginnerTekla Structural Designer96 reports

Create property sets for the concrete pedestals that the steel columns stand on (one report uses two sizes, 400 × 800 mm and 600 × 400 mm) and for the steel columns, then place them on the grid from base level to the right floor. Interior columns stop at different levels, so the construction levels have to be right first.

Make it a final-year project: Work out the base plate and anchor bolts for one pedestal by hand to IS 800, so you know what the pedestal size has to accommodate.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Model floor beams, roof rafters and bracing

IntermediateTekla Structural Designer87 reports

Model the first-floor beams, then rafters at roof level with moment-frame action in one direction and bracing in the other, placed where the design intent allows. This is the challenge where the stability system of the building is decided.

Make it a final-year project: Run the same building once with the bracing removed and every frame made a moment frame, and compare sway and steel weight.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Calculate dead and live loads and apply them in TSD

BeginnerTekla Structural Designer, IS 87583 reports

The sheet gives 50 mm floor finishes, 150 mm brick walls, roofing load from the purlin size and a 0.3 kN/m² ceiling load. You work out the loads by hand (50 mm finishes at 24 kN/m³ is 1.2 kN/m²; a 150 mm wall 5.2 m high at 20 kN/m³ is 15.6 kN/m), take imposed loads from IS 875 (Part 2), and apply them as area and line loads with load cases and combinations.

Make it a final-year project: Do a hand take-down of one interior column from roof to base and compare it with the TSD reaction.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Wind load by hand to IS 875 (Part 3), then with the wind wizard

IntermediateTekla Structural Designer, IS 875 (Part 3)80 reports

Basic wind speed 39 m/s and terrain category 2. You compute the design wind speed and pressure by hand, pick external and internal pressure coefficients for walls and roof in each wind direction, apply the net pressures to the model, and then generate the same loads on a separate copy with TSD's wind wizard.

Make it a final-year project: Put your hand calculation and the wizard's pressures side by side for one frame and explain every difference (k2 at eaves height, Kd, Ka, Kc and the 0.7 pz floor).

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Analyse and design the steel building

IntermediateTekla Structural Designer, IS 80075 reports

Run the analysis, read the bending moment, shear force and deflection diagrams for the members, then run the steel design and fix the members that fail by changing sections or restraints.

Make it a final-year project: Check one rafter and one column by hand to IS 800 (bending, shear, axial and their interaction) and compare utilisation with TSD.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

RC residential building

The same workflow on a concrete frame: covers, loads, IS 1893 seismic loads, column and beam design, slabs and piles.

Set up and model an RC residential building

BeginnerTekla Structural Designer, IS 45671 reports

Set the cover rules first: column 50 mm in contact with the ground and 40 mm above it, beam and slab 30 mm and 25 mm, pile cap 75 mm, foundation 50 mm. Then model the grids, levels, columns, beams and slabs from the given drawings.

Make it a final-year project: Check the given covers against the exposure conditions in IS 456 Table 16 and say which ones you would change for a coastal site.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Dead, live and wind loads on the RC building

BeginnerTekla Structural Designer, IS 87568 reports

The same load set as the steel building (50 mm finishes, 150 mm brick walls, roofing and a 0.3 kN/m² ceiling load), this time on a concrete frame, with imposed loads from IS 875 (Part 2) and wind from Part 3, set up as load cases and generated combinations.

Make it a final-year project: Compare the wind base shear with the seismic base shear from the next challenge and say which one governs this building.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Generate seismic loads to IS 1893 (zone II) and run the analysis

IntermediateTekla Structural Designer, IS 189367 reports

Use the seismic wizard for zone II and choose the rest yourself: importance factor, soil type, damping, response reduction factor and irregularities. Then run the analysis and explain what the results show.

Make it a final-year project: Work out the design base shear by hand (Ah × seismic weight) and check it against the wizard; then move the building to zone IV and see which members fail.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Design RC columns and beams from the analysis

IntermediateTekla Structural Designer, IS 45658 reports

Run the concrete design for the columns and beams, read the required steel, and change bar sizes and spacing until every member passes.

Make it a final-year project: Design one beam and one column by hand to IS 456 and draw them with IS 13920 ductile detailing.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Design the slabs and the pile foundations

IntermediateTekla Structural Designer, IS 45662 reports

Check every slab panel, add secondary beams where the span is too long for the depth, and settle on one depth and bar layout for easy construction (one report ends with 150 mm slabs and 10 mm bars at 175 mm). Then design the foundations from the column loads and soil type, here piles and pile caps.

Make it a final-year project: Compare piles with isolated footings for the same column loads, assuming a soil bearing capacity, and say when piles become necessary.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Course projects

Two complete buildings: a steel shed with a 10 t crane and an RC office.

Course Project 1: a steel building with a 10 t overhead crane

AdvancedTekla Structural Designer, IS 800, IS 87568 reports

A portal-frame building of about 38 m span with frames at 6 m (16 grid lines), concrete pedestals, an intermediate floor, crane brackets on the columns and a 10 t crane. Provide bracing and moment connections for stability, take dead, live, equipment and wind loads (150 mm brick walls, 1.5 kN/m² wall and roof cladding, 39 m/s wind), and deliver member reports and plan drawings.

Make it a final-year project: Add the crane load cases by hand from IS 875 (Part 2) clause 6.3 and check the gantry girder and bracket separately.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Course Project 2: an RC office building to IS codes

AdvancedTekla Structural Designer, IS 456, IS 189364 reports

Develop the general arrangement from the architect's plan and elevation, then analyse and design the building for dead, live, wind and seismic loads (one report uses 230 × 500 mm M30 beams with 30 mm cover and 40 mm for columns). Deliver member reports, structural plans and beam reinforcement drawings.

Make it a final-year project: Model the same office in ETABS and compare periods, base shear and steel quantities between the two programs.

Learn it in Analysis and Design of RCC & Steel Structures using Tekla Structural Designer

Before you start

All reports here come from one Skill-Lync course, Analysis and Design of RCC and Steel Structures using Tekla Structural Designer. Its challenges have stayed almost the same between batches, so the inputs quoted come from what several learners copied from the sheets.

Many reports in this course repeat each other word for word. We counted every public report, but picked examples by hand: reports with their own work, not copies of another report or of vendor documentation.

Reports are learner submissions from 2021 to 2025. Several contain mistakes (see the wind load FAQ), and many are screenshots of TSD output. Read them as examples of the work, not as answers.

Questions students ask

How do you calculate wind load on an industrial building to IS 875 (Part 3)?

Design wind speed Vz = Vb × k1 × k2 × k3 × k4 (clause 6.3), then pz = 0.6 Vz² in N/m² (clause 7.2), then pd = Kd × Ka × Kc × pz, but not less than 0.7 pz. For the challenge's 39 m/s, terrain category 2 and a 14 m eaves height on an inland site such as Pune: k1 = 1.0, k2 = 1.04 (between 1.00 at 10 m and 1.05 at 15 m), k3 = 1.0 and k4 = 1.0, so Vz = 40.6 m/s and pz = 987 N/m². For a main frame (Kd 0.9, Ka 0.8 for 100 m² or more, Kc 0.9) the product gives 640 N/m², below the 0.7 pz floor, so pd = 691 N/m², about 0.69 kN/m². Multiply by Cpe − Cpi for each face to get the net pressure.

What mistakes show up most in the TSD wind load reports?

Two, both in reports linked here. Using k4 = 1.15 without checking the site: clause 6.3.4 applies it to industrial structures only within about 60 km of the east coast and the Gujarat coast; elsewhere k4 = 1.0, and 1.15 raises the pressure by 32% (1.15²). And multiplying by k2 a second time after the pressure is worked out, when pz already includes it. Also note the internal pressure coefficient depends on the openings: ±0.2 below 5% of the wall area, ±0.5 for 5 to 20%, ±0.7 above 20%.

How do you get the seismic base shear for the zone II building?

IS 1893 (Part 1):2016 clause 6.4.2 gives Ah = (Z/2) × (I/R) × (Sa/g). Zone II has Z = 0.10. An RC residential building with a special moment resisting frame has R = 5 and, unless more than 200 people occupy it, I = 1.0. On the flat part of the spectrum (Sa/g = 2.5) that gives Ah = 0.05 × 0.2 × 2.5 = 0.025, so the base shear is 2.5% of the seismic weight. The seismic weight is the full dead load plus 25% of imposed loads up to 3 kN/m² (50% above that).

What crane loads go on the 10 t crane building?

IS 875 (Part 2) clause 6.3: for electric overhead cranes add 25% to the maximum static wheel loads on the crane girders; a horizontal surge across the rails of 5% of the weight of the crab plus the load lifted (10% for cranes with a rigid mast); and a longitudinal force along the rails of 5% of the static wheel loads. A 10 t crane lifts 98.1 kN; with a 35 kN crab, as one report assumes, the surge is 0.05 × 133.1 = 6.7 kN on one rail, shared by that rail's wheels.

Tekla Structural Designer or ETABS: which should I learn?

TSD handles steel and concrete in one model and is strong on steel buildings, portal frames, connections handed to Tekla Structures and automatic member design. ETABS is the common choice for multi-storey concrete buildings and shear walls in Indian design offices. If you are aiming at industrial and steel work, TSD (or STAAD.Pro) is the better fit; for high-rise residential and commercial, start with ETABS. Our ETABS project page has 13 challenges of that kind.

Turn a project into a job-ready portfolio

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.