ETABS projects and model examples
13 ETABS projects that Skill-Lync's civil engineering learners have actually done, 4,159 public reports in all. They start with earthquake damage, shear wall layouts and modal analysis by hand. Then come ETABS models checked against IS 1893, beam, column and shear wall detailing, and SAFE footings. They end with a G+3 hostel on piles, a tall building and a composite steel building. Each comes with what the challenge asks for, real reports to read, and one way to take it further.
As of 19 Nov 2026: 4,159 of 1,41,067 public learner reports match one of these ideas · Counts are reports, not unique students
How to pick one
- Get the model right before you design anything. The 25-storey challenge gives target periods (4.4 s and 4.2 s, within 2%) so you can tell whether your model is right. Use the same habit on every model: check the periods, the self-weight and the base reactions against a hand estimate before reading any design output.
- Do the hand work too. The earthquake concepts at the top of this page (damage photos, wall layouts, a 5-storey modal analysis by hand) are what an interviewer asks about. ETABS gives you numbers; you have to be able to say whether they make sense.
- Finish with drawings. Design output is not a deliverable. The detailing challenges and Project 2 end in beam, column, wall, pile cap and tie beam drawings, and that is what a design office or a site engineer looks at in a portfolio.
Earthquake concepts before ETABS
Damage photos, shear wall layouts and modal analysis by hand: the reasoning the software will not do for you.
Read earthquake damage: identify cracks and failures in RC members
You get photos of beams, columns and joints damaged in earthquakes and say what failed and why: a flexural hinge from stress reversal, a shear crack, a beam pulled out of a joint, a short-column failure. It is the reason behind every detailing rule you apply later.
Make it a final-year project: Collect photos from one real earthquake report (Bhuj 2001 or Turkey 2023), classify each failure, and name the IS 13920 clause that would have prevented it.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Compare three shear wall layouts for one building
A 20 m x 35 m plan with columns on a 5 m grid gets 250 mm shear walls in three arrangements with the same total wall area. You rank them on lateral and torsional stiffness, eccentricity, the steel needed for the same base moment, slab shrinkage restraint and foundations.
Make it a final-year project: Model all three layouts in ETABS and check whether the software agrees with your ranking on drift and torsion.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Structural dynamics by hand: modal analysis of a 5-storey frame
First the theory set: static versus dynamic analysis and elastic, inelastic and plastic force-displacement behaviour. Then a 5-storey frame with equal floor masses and five given periods (2 s down to about 0.3 s): compute participation factors, effective modal masses, base shear per mode and the SRSS total, and how many modes reach 90% of the mass.
Make it a final-year project: Write the eigenvalue solution yourself (numpy.linalg.eigh) for the same frame and check your periods against the given ones.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
ETABS modelling and seismic analysis
From architectural drawings to a checked model: periods, irregularity, drift and base shear.
Model a G+7 residential building from architectural drawings
Start from the architect's floor plans and a section through the stair and lift core. Decide where columns and shear walls go, set grids and storeys, define sections and materials, apply wall, floor-finish, live and water-tank loads, and run gravity and earthquake cases.
Make it a final-year project: Model the plan twice, once as a bare frame and once with a stair-lift core wall, and compare drift, period and column sizes.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Check a 25-storey model against target periods and IS 1893
A 25-storey frame on a 1.5 m plinth with 3 m storeys (76.5 m), 800 × 800 mm columns, 300 × 400 mm beams, 150 mm slabs, M30 and Fe 415, a 10 kN/m wall load and 3 kN/m² live load. Your model is right only if the first periods come out near 4.4 s (x) and 4.2 s (y), within 2%. Then check torsional and vertical irregularity and storey drift.
Make it a final-year project: Add infill stiffness or shear walls and show how far the period moves towards the code's empirical value.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Course Project 1: compare buildings from G+2 to G+25 under earthquake loads
About ten buildings on the same 4 × 3 bay grid with 4 m spans: G+2, G+5 with columns turned in x and then in y, G+10, and several G+25 versions with columns stepped down the height. You compare periods, mode shapes, base shear and drift, and explain each difference.
Make it a final-year project: Add a G+25 version with a central core wall and plot period and roof drift against height for all of them on one chart.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Design and detailing from ETABS output
Beams, columns, shear walls and footings, ending in drawings a site can build from.
Turn ETABS beam output into a reinforcement drawing
Run the design on a given model, read the required top and bottom steel at each support and mid-span of two continuous beams (one is seven spans long), choose bar sizes and numbers, and draw the longitudinal and shear reinforcement with curtailment and laps.
Make it a final-year project: Recheck one beam by hand (moment capacity and shear) and list every IS 13920 ductility rule your drawing satisfies.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Column reinforcement detailing from ETABS
Pick two columns in a designed model, take the required longitudinal steel and the special confining zones from ETABS, and draw the section and elevation: bar arrangement, ties, lap location and confinement at both ends.
Make it a final-year project: Draw the beam-column joint at one floor in 3D and show that the bars from both beams and the column fit without clashing.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Design and detail an RCC shear wall in ETABS
In a given G+6 model, check the model, run analysis and the wall design, then pull out the longitudinal steel ratio, the boundary element length and the shear steel ratio, and draw the wall's cross-section and elevation.
Make it a final-year project: Change the wall length or thickness and show when the boundary element is no longer needed.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Design an isolated footing and a raft in SAFE
A 400 × 400 mm column carries 2,000 kN factored (1.5 DL + 1.5 LL) on soil with a safe bearing capacity of 150 kN/m². You work out the subgrade modulus, model the footing as a mat in SAFE, then check soil pressure, punching shear and bending and read off the steel.
Make it a final-year project: Size the same footing by hand to IS 456 and compare depth and steel with SAFE; then move it next to a property line and design it as a combined footing.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Course projects and advanced buildings
A complete hostel on piles, a tall building and a composite steel-concrete structure.
Course Project 2: a G+3 hostel on piles in Guwahati (seismic zone V)
A hostel block in two parts on either side of an expansion gap, AAC block walls, type 3 soil, ground floor raised 2 m above site level against flooding, M25 with Fe 500 main bars and Fe 415 ties, on 500 mm piles 10 m long rated at 280 kN. Deliver both ETABS models, pile and pile cap details, tie beams and column reinforcement drawings.
Make it a final-year project: Compare the pile count with a raft on the same soil, and check what the 2 m stilt-like ground storey does to soft-storey and drift checks.
Learn it in Analysis and Design of High Rise Buildings using ETABS and Foundation Design using SAFE for Seismic Loads
Model, analyse and design a tall building
A 30 to 40 hour project: import the architect's floor plan, set up grids and storeys, define wind and seismic load patterns from given parameters, add P-delta, design the members (1,000 × 1,000 mm columns and 750 × 1,000 mm beams appear in reports), and submit the model as .e2k with a full report.
Make it a final-year project: Design the same tower to two codes (IS and ASCE 7, or IS and Eurocode) and explain where the base shear and drift differ.
Learn it in Structural Actions on Tall Buildings using International Codes
Composite steel-concrete building with ComFlor and ETABS
Lay out two framing options for a steel building, pick a metal deck in ComFlor for the span and fire rating, model composite beams and columns in ETABS, and design the beams, studs and columns.
Make it a final-year project: Compare the composite floor with an RCC flat slab for the same span on depth, weight and steel tonnage.
Learn it in Structural Analysis and Design of Composite Structures using ETABS
Before you start
Most reports here come from Skill-Lync's ETABS and SAFE course for high-rise buildings. The tall-building and composite projects come from two follow-on courses. The modal, shear wall layout and damage challenges have no ETABS tag, but most of the learners who did them also did the course's ETABS detailing challenge.
The inputs quoted (storeys, sections, loads, pile data, target periods) come from what several learners copied from each challenge sheet, and the sheets have changed a little between batches. Use them to judge the size of a task, then follow the sheet you are given.
Reports are learner submissions from 2020 to 2025, and many are screenshots of ETABS output with little checking. We left out reports pasted from a chat assistant. Read the rest as examples of the work, not as answers. A wrong model with neat tables is the most common mistake.
Questions students ask
What are good ETABS projects for civil engineering students?
One building taken all the way: model it from architectural drawings, check periods, drift and irregularity under IS 1893, design and detail the beams, columns and shear walls, then design the foundation. Project 2 on this page does exactly that for a G+3 hostel on piles in Guwahati (seismic zone V). If you have time for only one more, the 25-storey model is quick and tells you whether your modelling is right.
Where can I find ETABS model examples?
This page links 4,159 public learner reports across 13 ETABS challenges, each with the challenge's inputs (storeys, sections, grades, loads) so you can rebuild the model yourself. Learners attach their own files to some reports, but rebuilding the model from the inputs teaches far more than opening someone else's .edb file.
Why does ETABS give a period of 4.4 s when the IS 1893 formula gives about 1.9 s?
For the 25-storey frame (76.5 m), IS 1893 clause 7.6.2(a) gives Ta = 0.075 × 76.5^0.75 = 1.94 s for a bare RC frame. ETABS calculates the period of your model, a flexible bare frame on pinned supports, which comes out near 4.4 s. Real buildings are stiffer because of infill walls, so the code uses the empirical value for the base shear. If the response spectrum base shear is lower than that, clause 7.7.3 scales the member forces up to match. Displacements need not be scaled.
What is the storey drift limit in IS 1893?
Clause 7.11.1.1: storey drift under the design base shear with all load factors set to 1.0 must not exceed 0.004 times the storey height. For a 3 m storey that is 12 mm.
How do you get the modulus of subgrade reaction for a SAFE footing?
A common estimate is Bowles' ks = 40 × safety factor × allowable bearing pressure, in kN/m³. It assumes a settlement of about 25 mm, since 1/0.0254 ≈ 40. For the SAFE challenge's 150 kN/m² soil and a safety factor of 3 that is 18,000 kN/m³. Use a value from a soil report when you have one, and check how sensitive the result is.
ETABS or STAAD.Pro: which should I learn?
For multi-storey RCC buildings, ETABS is built around storeys, diaphragms and shear walls, and its partner SAFE designs the slabs and foundations. STAAD.Pro is a general frame program used a lot for industrial steel, pipe racks and towers. Learn one well and model a small frame in the other. Only 38 public Skill-Lync reports use STAAD.Pro, too few for their own list, so they are on the civil project ideas page.