Structural dynamics calculator (SDOF period, damping, spectrum)

Turn the five questions of the "Structural dynamics" challenge into numbers you can see. Find the natural period and frequency of a one-storey frame, plot free vibration in all four damping cases with the three forces of the equation of motion, compare a static load with a step, pulse or harmonic one, trace elastic, plastic and hysteretic force-displacement loops, and build a response spectrum from a ground motion with the IS 1893 design spectrum on top. Free, no sign-up, runs in your browser.

IS 1893 (Part 1):2016 cl 3.2, 3.4, 3.18, 6.4.2, 7.2.4 · IS 456:2000 cl 6.2.3.1 · Newmark average acceleration · checked against an independent solution (1,329 checks at build) · Updated 23 Nov 2026

Q4. Provide the relationship between natural period (Tn) and natural frequency (f), with their definitions.

Natural periodTn = 0.2308 s230.77 ms
Natural frequencyfn = 4.33 Hzcycles per second
Circular frequencyωn = 27.23 rad/s= 2π fn

    What is structural dynamics, and what is the single degree of freedom model?

    Structural dynamics is the analysis of structures under loads that change quickly: earthquake, wind gusts, machines, blasts, moving vehicles. When the load changes quickly, the structure's own motion matters, so two forces appear that static analysis ignores: inertia (mass times acceleration) and damping (energy loss). The simplest model keeps one number for each: a mass m on a spring of stiffness k with a damper c, free to move in one direction. A one-storey frame with a stiff slab is exactly that, and so, to a first approximation, is a water tank on a shaft.

    Skill-Lync's "Structural dynamics" challenge, part of the ETABS, high-rise building design and seismic analysis courses, asks five questions about this model. The tabs above answer them in order, with your own numbers.

    What is the relationship between natural period and natural frequency?

    IS 1893:2016 cl 3.18 defines the natural period as "the time taken (in second) by the structure to complete one cycle of oscillation in its natural mode". The frequency is how many cycles fit in one second, so the two are reciprocals. The circular frequency counts radians instead of cycles: one cycle is 2π radians.

    The unit decides which one you hold. If k and m give 27.2, that is rad/s and it is ωn. Divide by 2π for hertz. Corpus note: 40 of 249 public reports define frequency as cycles per second and then give the unit as radians per second. Tab 6 catches it.

    Three routes get ωn in tab 1. With a mass and a lateral stiffness, use the first line. For a one-storey frame, the stiffness comes from the columns. For an existing structure you can weigh or load, the static deflection under its own weight gives it directly (Gavin, Duke CEE 541: Dst = mg/k = g/ωn²).

    The concrete modulus is Ec = 5000√fck N/mm², "the short term static modulus of elasticity", with measured values that "may differ by ± 20 percent" (IS 456:2000 cl 6.2.3.1). A ±20% error in E is ±10% in the period. The steel modulus is 200 kN/mm² (cl 5.6.3).

    Worked example: the one-storey RC frame preset

    Four 300 × 300 mm columns of M25 concrete, 3.5 m high, fixed at the base, under a rigid slab. We assume the slab, beams, finishes and half the column height weigh 250 kN together: a round number for the example, not a code value. Edit it for your own frame.

    The frame has Tn = 0.231 s and fn = 4.33 Hz. With pinned bases the stiffness falls to a quarter (4,723 kN/m) and the period doubles. Damping at ζ = 5% makes the damped period TD = 0.2311 s, 0.13% longer than Tn:

    Below ζ = 20% the damped and undamped periods differ by less than about 2%, so for buildings, which are in the 2 to 10% range, Tn is what people mean. The IS 1893 empirical period for an RC frame of the same height is Ta = 0.075h0.75 = 0.192 s (cl 7.6.2). Ta is a code estimate for multi-storey frames, so comparing it with a one-storey frame is only a sanity check, which is how tab 1 uses it.

    What do mass, stiffness and damping do in the equation of motion?

    Newton's second law for the mass says the three internal forces balance the load: the inertia force fI = mü resists acceleration, the damping force fD = cu̇ resists velocity, and the spring force fS = ku resists displacement. Gavin's Duke notes call the damping model "a linear viscous approximation for the truly" complicated energy loss in real structures, and note that "damping forces are generally much smaller than inertial and elastic forces". In tab 2 the second chart draws the three forces against time. At every instant they add to p(t), which is zero in free vibration.

    IS 1893:2016 cl 3.2 defines critical damping as "the damping beyond which the free vibration motion will not be oscillatory", and cl 3.3 describes damping as the effect of "internal friction, inelasticity of materials, slipping, sliding, etc" that reduces the amplitude, "expressed as a fraction of critical damping". The four cases come from the roots of the characteristic equation:

    Only the underdamped case oscillates. Critical and overdamped systems creep back to zero without crossing it more than once. Real buildings are all underdamped, with ζ of a few percent. Corpus note: 67 of 242 reports quote a damping ratio value; 13 give 5%.

    How do you get the damping ratio from a free-vibration test?

    Pluck the structure and record the decay. The amplitude falls by the same factor every cycle, whatever the frequency. The natural log of that factor is the logarithmic decrement. Measure it over j cycles for less scatter.

    The approximation ζ ≈ δ/2π "is accurate to within 3% for ζ < 0.2 and is accurate to within 1.5% for ζ < 0.1" (Gavin). Tab 2 prints both, and the number of cycles in which the amplitude halves: with the default 10 and 7.3 over 5 cycles, δ = 0.0629, ζ = 0.0100 and the amplitude halves in 11.0 cycles.

    What is a typical value? IS 1893:2016 cl 7.2.4 fixes 5% of critical damping for the design spectrum of every building, "irrespective of the material of construction", reasoning that "buildings experience inelastic deformations under design level earthquake effects, resulting in much higher energy dissipation than that due to initial structural damping". It is a design value, not a measurement. A US Department of Energy standard for nuclear facilities (DOE-STD-1020-2002, Table 2-2) lists 4, 7 and 10% for reinforced concrete structures at its three response levels and 2, 4 and 7% for welded metal ones; that is a published example for another purpose, not an Indian code value. For a real structure, measure it.

    When does a dynamic load need dynamic analysis?

    Apply the same peak load P0 to the same oscillator in four ways and divide the peak displacement by the static one, ust = P0/k. That ratio is the dynamic amplification factor Rd: "the factor by which a static displacement response is amplified due to the fact that the external forcing is dynamic" (Gavin).

    A step (a load applied suddenly and left on) gives Rd = 2 with no damping and 1.854 with ζ = 5%. A pulse depends on how long it lasts compared with Tn. A rectangular pulse longer than half a period reaches the full step value; a shorter one gives 2 sin(πtd/Tn), and for a very short one the peak is far below the static value: a sharp kick moves a heavy, soft structure only a little. A half-sine pulse has a closed form too:

    The harmonic load is the resonance case. Slow loading (r well below 1) gives Rd close to 1, so the response is about static, and static analysis is fine. At r = 1 the factor is 1/(2ζ), which is 10.0 at ζ = 5% and unbounded with no damping. Far above resonance the structure barely moves. That is the whole case for dynamic analysis: depending on duration or frequency, the peak can be a fraction of the static answer or many times it. The derivations are ours and the page checks them against numerical integration; see how we checked it below.

    What is the difference between elastic, inelastic and plastic behaviour?

    Elastic: the structure returns to its original shape when the load is removed (after elastic loading "the piece returns to its original size"). Plastic: the material has been taken past the yield point and a deformation stays when the load is removed ("the ability of a solid material to undergo permanent deformation"; the transition is "known as yielding"; Wikipedia, Plasticity). Corpus note: 40 of 246 public reports write that plastic behaviour begins when the material has "completely lost its ductility". It is the opposite: plastic flow is what a ductile material does; a material that has lost ductility is brittle and breaks. 31 of the same reports paste that inelastic material shows "no elongation or deflection" and ruptures suddenly, which describes a brittle fracture, not inelastic behaviour.

    Inelastic is the wider word: any behaviour where the force is not a single-valued function of displacement. Yielding of steel is one way to get it; cracking and crushing of concrete, slip and friction are others (our reading of how the term is used; sources.md). Plastic yielding is therefore a kind of inelastic behaviour, and engineers often use the two words for the same thing in earthquake design.

    Nonlinear elastic means the force-displacement curve bends but unloading retraces the same curve, so there is no permanent deformation and no energy loss (tab 4, second loop: zero area). Nonlinear inelastic means it bends and unloading takes a different path, so loading and unloading enclose an area. That area, the integral of f du over a cycle, is the energy dissipated in one cycle. The tool draws it two ways: a bilinear elastoplastic loop, with a yield point and a post-yield slope αk, and a smooth loop from a Ramberg-Osgood backbone with the Masing rule (the unloading branch has the shape of the first loading, scaled by 2; sources.md).

    At μ = um/uy = 4 an elastic-perfectly-plastic loop (α = 0) dissipates 4Fy(um − uy) = 12.0 Fyuy per cycle and unloads to a residual displacement of 3.0 uy. The page computes the area by numerical integration (12.000) and the closed form agrees. The ductility μ is defined here as um/uy; a ductile structure can dissipate energy in many such loops, which is why IS 1893 divides the elastic design force by the response reduction factor R (cl 7.2.6).

    What is a response spectrum, and how is it built?

    IS 1893:2016 cl 3.4 says a design acceleration spectrum "refers to an average smoothened graph of maximum acceleration as a function of natural frequency or natural period of oscillation for a specified damping ratio for the expected earthquake excitations at the base of a single degree of freedom system". University of Iowa lecture notes: "A response spectrum is a plot of maximum response of a single degree of freedom system subject to a specific input ... versus period of vibration". So: one input, one damping, one point per natural period, and the point is a peak.

    To build one, solve the equation of motion of the oscillator under the ground acceleration and keep the peak. Tab 5 does this for 120 periods between 0.02 and 4 s with the Newmark average acceleration method, which Gavin describes as "implicit and unconditionally stable" with the acceleration "presumed to be constant" in each step; the arXiv survey of SDOF methods (2509.15474, eq 105-107) gives the same update equations. The page solves them for the new acceleration:

    We take Δt no larger than Tn/20 (the record is interpolated linearly and sub-stepped when its own time step is larger) and add 1.5 periods of free vibration after the record, so a short pulse's peak is not missed. Then:

    V and A are "pseudo" because they are not the true peak velocity and acceleration but ωnD and ωn²D, which are what the force in the spring is proportional to. The default half-sine pulse of 0.3 g and 0.5 s gives, for the oscillator of Tn = 0.5 s at ζ = 5%, D = 30.2 mm and A = 0.49 g. The record's spectrum peaks at A = 0.49 g near Tn = 0.62 s.

    The dashed curve in the chart is the IS 1893:2016 design spectrum shape Sa/g (5% damping, soil type I, II or III), imported from the same code the seismic base shear calculator uses. They are different things. One is the response of one record: jagged, scaled to that ground motion. The other is a smoothed, code-defined curve that stands for many possible earthquakes, to be scaled by the zone factor Z, importance I and response reduction R. Overlaying them shows how a single record sits against the code, nothing more. For building response by modes from the code curve, see the response spectrum analysis calculator, which is the multi-degree-of-freedom step after this one.

    What 255 reports wrote

    We read the 255 public reports titled "Structural dynamics" as of 23 Nov 2026, n = 255. 2 of them have no text to read (pictures only); counts are out of the reports with text for that question, shown as count / of. The counts are of what the text shows. The question wording is stripped first, since most reports paste it. The two links under each row are examples of reports that say it.

    Q1 Static and dynamic analysis

    • 119 / 249Say static analysis ignores inertia (and damping) forces. Correct: slow loading makes inertia negligible. report 1report 2
    • 112 / 249Define static loading as not varying with time. Correct, and the usual first difference. report 1report 2
    • 71 / 249Name earthquake or wind as a dynamic load. Correct, and the example most reports reach for. report 1report 2
    • 56 / 249Say a dynamic analysis solves mass and damping matrices on top of the stiffness matrix. Correct: M and C enter only when motion matters. report 1report 2

    Q2 Elastic, inelastic, plastic, non-linear inelastic

    • 196 / 246Write fs = ku for the linear elastic case. Correct: lateral force proportional to deformation, k the lateral stiffness. report 1report 2
    • 157 / 246Say deformation stays after the load is removed (permanent or irreversible). Correct for inelastic and plastic behaviour. report 1report 2
    • 121 / 246Mention the yield point or yielding. Correct. report 1report 2
    • 83 / 246Say the inelastic force depends on the history of deformation (loading and unloading differ). Correct: the key idea of hysteretic behaviour. report 1report 2
    • 40 / 246Write that plastic behaviour occurs when the material has "completely lost its ductility". A slip: plastic flow is what ductile material does. Losing ductility is brittleness. report 1report 2
    • 31 / 246Paste the line that inelastic material shows "no elongation or deflection" and ruptures suddenly. A slip: that describes brittle fracture, not inelastic behaviour. Inelastic means permanent deformation. report 1report 2

    Q3 Mass, stiffness and damping in the equation of motion

    • 197 / 246Write the damping force as proportional to velocity, fd = c u-dot. Correct: the viscous damper model. report 1report 2
    • 130 / 246Write the full equation of motion, m u-ddot + c u-dot + k u = p(t). Correct (garbled in some copies; counts any m..+c..+k.. form). report 1report 2
    • 114 / 246Write the inertia force as mass times acceleration, fi = m u-double-dot. Correct. report 1report 2
    • 19 / 246List sources of damping (steel connection friction, microcracks, non-structural elements). Correct. report 1report 2

    Q4 Natural period and natural frequency

    • 197 / 249State that frequency is the reciprocal of period, f = 1/Tn. Correct. report 1report 2
    • 153 / 249Give the unit of frequency as hertz (or Hz). Correct. report 1report 2
    • 129 / 249Write Tn = 2π / ωn. Correct. report 1report 2
    • 40 / 249Define natural frequency as cycles in one second but give its unit as radians per second. A slip: cycles per second is hertz. Radians per second belongs to the circular frequency ωn = 2πf. report 1report 2
    • 40 / 249Say stiffer means shorter period and higher frequency (heavier means the opposite). Correct. report 1report 2
    • 31 / 249Write ωn = √(k/m). Correct. report 1report 2
    • 22 / 249Write the period as T = 2π√(k/m). A slip: the root is of m/k. As written it gives a period that falls as the structure gets heavier. report 1report 2
    • 16 / 249Cite IS 1893 for the approximate period of a multi-storey building. Pointer only: none of these reports gives the empirical formula itself. report 1report 2

    Q5 Response spectrum

    • 149 / 242Tie the spectrum to design use (equivalent static force, base shear, building codes). Correct. report 1report 2
    • 145 / 242Say each spectrum is drawn for a fixed damping ratio (several curves for several ratios). Correct. report 1report 2
    • 135 / 242Define the response spectrum as peak response plotted against natural period. Correct. report 1report 2
    • 80 / 242Name three spectra: deformation, pseudo-velocity and pseudo-acceleration. Correct. report 1report 2
    • 70 / 242Write the pseudo-acceleration link A = ωn² D. Correct. report 1report 2

    What stands out: the definitions are mostly right and almost nothing is computed. 197 of 249 state f = 1/Tn, yet only 31 write ωn = √(k/m) and 22 write the period as 2π√(k/m), with the root upside down, which gives a period that gets shorter as the structure gets heavier. Few name a method for finding a response spectrum (Newmark, Duhamel) at all, so tab 5 is the part of the challenge the reports skip. Only 17 cite IS 1893.

    The figures are first-party counts, a starting point rather than a measure of student ability: most reports are copied definitions, which is why the counts mean "wrote it" and not "understood it". Tab 6 checks the four slips that reach 10 or more reports.

    How we checked the calculator

    An independent Python script, scripts/verify/sdof.py, rebuilds every number with its own code, and this page refuses to build if the browser code differs from it in any of 1,329 numbers (453 further assertions run inside the script). It solves free vibration with complex characteristic roots and checks all four damping cases against RK4 integration, including forces that sum to zero and the energy balance; computes the step, rectangular and half-sine shock spectra with closed forms and RK4; checks the harmonic response, amplification and phase against numerical integration; runs the bilinear loop through a classical return mapping with back stress and compares it with the closed-form loop area and residual displacement; solves Ramberg-Osgood by bisection and compares the Masing loop area with its closed form; runs the response spectrum with Newmark in the effective-stiffness form and a second integrator (RK4 on the same record), with the pulse spectra checked against D = RdA/ω² to 3%; and re-types the IS 1893 spectrum shape from the table. The preset frame is also worked by hand above and asserted. Two deliberate bugs (the concrete modulus changed from 5000 to 4700, and the Newmark γ from 0.5 to 0.55) each make the build fail.

    What this calculator does not cover

    • One degree of freedom. A multi-storey building has one mode per storey. Use the response spectrum analysis calculator for modes, participation and SRSS/CQC.
    • Viscous damping. Real damping is not exactly viscous; the model is an approximation, as Gavin notes.
    • The frame route. Rigid slab, columns bending in double curvature (fixed) or pinned at the base. Real beams are flexible, and cracked concrete is softer than the gross section: Ec = 5000√fck is itself ±20%.
    • Hysteresis. Constant-amplitude cycles; no stiffness degradation, pinching or strength loss. The smooth loop is the Masing rule and is not valid for variable-amplitude histories.
    • Records. No built-in earthquake record: we could not confirm the licence of a public copy, so paste your own. The cap is 6,000 points. A response spectrum of a real record is jagged; do not read it as a design spectrum.
    Learn structural dynamics

    The Structural dynamics challenge is part of Skill-Lync's ETABS, high-rise building design and seismic analysis courses, where these ideas turn into modal analysis, response spectrum analysis and foundation design.

    Frequently asked questions

    What is the natural period of a structure?

    The natural period Tn is the time one free oscillation takes when nothing drives it. For a single degree of freedom system Tn = 2π√(m/k), in seconds. IS 1893:2016 cl 3.18 defines it as the time to complete one cycle of oscillation in its natural mode. Stiffer or lighter structures have shorter periods.

    What is the difference between natural period and natural frequency?

    They are reciprocals. The period Tn is seconds per cycle and the frequency fn is cycles per second, in hertz: fn = 1/Tn. The circular frequency ωn = 2πfn is in radians per second and equals √(k/m). Giving ωn as the frequency is off by 2π, so check the unit.

    How do you calculate the natural frequency of a building?

    For a one-storey frame, add the column lateral stiffnesses (12EI/h³ each for a fixed base, 3EI/h³ for a pinned base), divide by the mass W/g, take the root for ωn and divide by 2π. For a multi-storey building use modal analysis, or the IS 1893 empirical Ta as a first estimate.

    What is the damping ratio and what is a typical value for RC buildings?

    The damping ratio ζ is the damping coefficient over its critical value, ζ = c/(2√(km)). IS 1893:2016 cl 7.2.4 fixes 5% for design spectra whatever the material. A US DOE standard (DOE-STD-1020) lists 4% to 10% for reinforced concrete depending on stress level. Measure ζ from a free-vibration test where you can.

    What is the dynamic amplification factor?

    It is the peak dynamic displacement divided by the static displacement under the same load, Rd = u_max/u_st. For a harmonic load at frequency ratio r it is 1/√((1−r²)² + (2ζr)²), which reaches 1/(2ζ) at r = 1. For a suddenly applied constant load it is 2 with no damping.

    Why does a suddenly applied load double the deflection?

    The load acts at full size from the first instant, while the structure is still at rest. It does work all the way to the static position, arrives there moving, and overshoots by the same distance. With no damping the peak is 2 u_st; with damping ζ it is 1 + e^(−ζπ/√(1−ζ²)).

    What is a response spectrum?

    A response spectrum is a plot of the maximum response (displacement, pseudo-velocity or pseudo-acceleration) of single degree of freedom oscillators of different natural periods, all with the same damping, to one ground motion. Period is on the horizontal axis. IS 1893 smooths such curves into its design spectrum.

    How is a response spectrum generated?

    Take one ground acceleration record. For each period Tn from 0.02 to 4 s, integrate ü + 2ζωn u̇ + ωn² u = −ag(t), for example with the Newmark average acceleration method, and keep the peak |u| = D. Then V = ωnD and A = ωn²D. Plot them against Tn, as tab 5 does.

    What is the difference between static and dynamic analysis?

    Static analysis applies loads that do not change with time, or change so slowly that inertia and damping forces are negligible, so only stiffness matters. Dynamic analysis adds mass and damping because the load changes quickly compared with the natural period. The dynamic peak can be above or below the static value.

    What is ductility?

    Ductility is the ability to deform beyond yield without losing strength. This tool uses displacement ductility μ = um/uy, the peak displacement over the yield displacement. A ductile structure dissipates energy in hysteresis loops, which is why IS 1893 divides the elastic design force by a response reduction factor R.

    Related on Skill-Lync

    Sources

    • Bureau of Indian Standards, IS 1893 (Part 1):2016 Criteria for Earthquake Resistant Design of Structures, cl 3.2, 3.3, 3.4, 3.18, 6.4.2, 7.2.4, 7.2.6, 7.6.2. The 2025 revision was withdrawn.
    • Bureau of Indian Standards, IS 456:2000, cl 5.6.3 and 6.2.3.1 (Ec = 5000√fck, ±20%).
    • H. P. Gavin, Dynamics of Simple Oscillators, CEE 541 Structural Dynamics, Duke University (2026): critical damping, static deflection, logarithmic decrement, dynamic amplification factor.
    • H. P. Gavin, Numerical Integration for Structural Dynamics, CEE 541, Duke University (2025): Newmark-β method.
    • Numerical Discretization Methods for Seismic Response Analysis of SDOF Systems: A Unified Perspective, arXiv 2509.15474, eq 105-107.
    • S. Xiao, Lecture 17: Response Spectra, 058:153 Fundamental of Vibration, University of Iowa.
    • M. Kalina, T. Schneider, H. Waisman, M. Kästner, Phase-field models for ductile fatigue fracture, arXiv 2411.05015, s.4.3 (Ramberg-Osgood curve; Masing rule).
    • US Department of Energy, DOE-STD-1020-2002, Table 2-2 Specified Damping Values; Wikipedia, Plasticity (physics) (definitions of elastic and plastic).
    • Skill-Lync, the 255 public reports titled "Structural dynamics", read 23 Nov 2026.
    Free counselling

    From a dynamics challenge to a structural design job.

    Structural dynamics, ETABS and IS 1893 are what building design consultancies test for. A Skill-Lync counsellor can map the course that fits the role you want.

    Talk to a structural design course counsellor

    Free. We call you back, usually the same day.

    By submitting you agree to our Terms and Privacy Policy.

    Talk to a career counsellor

    Talk to a career counsellor

    Free 20-minute call. We'll map the right course to where you want to work.

    By submitting you agree to our Terms and Privacy Policy.