GATE Civil: Concrete Structures (limit state design, RC beams, shear, slabs, columns, prestressed concrete), previous-year questions solved, part 2
Part 2 of 2 of the Concrete Structures (RCC and PSC) hub: 13 more official GATE CE questions on shear, torsion, bond and development length, slabs and columns and prestressed concrete (not in the 2027 syllabus), each solved step by step and checked against the official answer key. Part 1 covers limit state and working stress concepts and flexure: singly and doubly reinforced beams.
Questions from the ten official GATE CE papers, sessions CE1 and CE2 of GATE 2022 (IIT Kharagpur), 2023 (IIT Kanpur), 2024 (IISc Bengaluru), 2025 (IIT Roorkee) and 2026 (IIT Guwahati); solutions by Skill-Lync. · Updated 17 Nov 2026 · 13 of 25 questions on this page
Spacing of 2-legged 10 mm Fe415 stirrups for an M30 beam (300 x 580) carrying 440 kN factored shear
A reinforced concrete beam with rectangular cross section (width = 300 mm, effective depth = 580 mm) is made of M30 grade concrete. It has 1% longitudinal tension reinforcement of Fe 415 grade steel. The design shear strength for this beam is 0.66 N/mm2. The beam has to resist a factored shear force of 440 kN. The spacing of two-legged, 10 mm diameter vertical stirrups of Fe 415 grade steel is __________mm. (round off to the nearest integer)
Answer: Official key: 100 to 102
- Nominal shear stress: . This exceeds but is below for M30 (IS 456 Table 20), so the section is fine and stirrups are needed.
- Concrete share: , so .
- Two legs of 10 mm: .
- IS 456 Cl. 40.4(a): , so mm.
- Maximum spacing (Cl. 26.5.1.5) is mm, so strength governs. Spacing = 101 mm
Trap: dropping the 0.87 partial safety factor gives 116 mm, and designing the stirrups for the full 440 kN (ignoring ) gives 75 mm; both fall outside the key.
On site this becomes 10 mm 2-legged stirrups at 100 mm c/c near the supports, relaxed further along the span where shear drops; ETABS and STAAD.Pro RC design reports print exactly this and check for every beam segment.
Shear design of RCC beams: which statements on shear failure and IS 456 nominal shear stress are true?
With regard to the shear design of RCC beams, which of the following statements is/are TRUE?
- (A)Excessive shear reinforcement can lead to compression failure in concrete
- (B)Beams without shear reinforcement, even if adequately designed for flexure, can have brittle failure
- (C)The main (longitudinal) reinforcement plays no role in the shear resistance of beam
- (D)As per IS456:2000, the nominal shear stress in the beams of varying depth depends on both the design shear force as well as the design bending moment
Answer: (A), (B) and (D) Official key: A, B, D
- (A) True. Stirrups cannot raise shear capacity without limit: the inclined concrete struts between diagonal cracks crush first (web crushing). That is why IS 456 Cl. 40.2.3 caps at even with shear steel (Table 20: for M20).
- (B) True. Without stirrups a beam strong in bending can fail by diagonal tension, suddenly and with little warning; Cl. 26.5.1.6 demands minimum shear reinforcement for this reason.
- (C) False. Longitudinal bars give dowel action and keep cracks narrow for aggregate interlock, so in Table 19 rises with : for M20, at but at .
- (D) True. Cl. 40.1.1: for varying depth , so the moment enters through the inclined compression or tension force.
- Answer: (A), (B) and (D)
Trap: ticking (C). Treating the tension bars as irrelevant to shear makes students forget why is read off with , and why curtailing bars near supports needs extra shear checks (Cl. 26.2.3.2).
Beam design reports from ETABS or RCDC list , and for every member; when exceeds the only fix is a bigger section, and haunched beams and tapered cantilevers are checked with the varying-depth formula of Cl. 40.1.1.
RC beam 250 x 500, design shear strength 0.3 MPa: what pure torsion can it resist as per IS 456?
Answer: Official key: 5.7 to 6.0
- IS 456 Cl. 41.3.1 converts torsion into an equivalent shear: . Under pure torsion , so .
- Equivalent nominal shear stress . The concrete alone carries it while (Cl. 41.3.3); beyond that, closed stirrups and longitudinal torsion steel are needed.
- Set : , so .
- That is , inside the key 5.7 to 6.0.
Trap: dividing by the depth instead of the width (writing ) gives , double the capacity. The code uses the width because a narrow web is what torsion cracks first.
Spandrel and edge beams carrying a cantilever slab or canopy are the usual torsion members. RCDC and ETABS report the equivalent shear and equivalent moment of IS 456 Cl. 41.3 and 41.4 for every beam, and a beam whose exceeds gets closed stirrups and side-face bars.
2-legged 10 mm Fe415 stirrups at 100 mm, d = 500 mm: what shear do the vertical stirrups resist (IS 456)?
As per IS 456:2000, the maximum shear resisted by the vertical stirrups (in kN), as per limit state design, is ___________ (round off to one decimal place).
Answer: Official key: 283.0 to 284.0
- IS 456 Cl. 40.4(a), vertical stirrups: .
- Two legs of 10 mm: .
- , so the stirrups resist .
- The 3 bars of 20 mm only set of the concrete (Table 19), which is not asked here. The note on diagonal compression means the cap (Table 20) need not be checked.
Traps: counting one leg gives 141.8 kN; leaving out the 0.87 (that is, with ) gives 325.9 kN. Both are outside the key.
Near supports, where shear peaks, designers tighten stirrup spacing to 100 mm or less exactly for this reason; the provided must cover . Beam schedules from ETABS/RCDC list the stirrup diameter, legs and spacing per zone, and site engineers check the spacing at the support before the pour.
Slab with 250 mm effective depth and 0.2% main steel: spacing of 8 mm bars
A slab panel with an effective depth of 250 mm is reinforced with 0.2% main reinforcement using 8 mm diameter steel bars. The uniform center-to-center spacing (in mm) at which the 8 mm diameter bars are placed in the slab panel is ________ (rounded off to the nearest integer).
Answer: (100.5 mm) Official key: 99 to 102
- Slabs are designed per metre width, . With the effective depth given, the steel ratio is on : .
- One 8 mm bar: .
- Spacing: .
- Check IS 456 Cl. 26.3.3(b)(1): main bars at most apart, so 100 mm is fine.
Answer: (on site, 8 mm bars at 100 mm c/c).
Trap: reaching for the IS 456 Cl. 26.5.2.1 minimum of 0.12% gives . The question fixes the steel at 0.2%, so the code minimum is irrelevant here.
This is the line every slab schedule ends on: required Ast per metre converted to "T8 @ 100 c/c". Detailers round down to a 25 mm module so bar benders and site engineers can mark and check spacing with a tape.
Rankine-Grashoff method: ratio of design moments Mux/Muy in a simply supported two-way slab
A simply supported, uniformly loaded, two-way slab panel is torsionally unrestrained. The effective span lengths along the short span (x) and long span (y) directions of the panel are and , respectively. The design moments for the reinforcements along the x and y directions are and , respectively. By using Rankine-Grashoff method, the ratio is proportional to
- (A)
- (B)
- (C)
- (D)
Answer: (D) Official key: D
- Rankine-Grashoff splits the load into carried by a short-span strip and by a long-span strip, so that both strips deflect equally at the centre.
- Equal deflection of two simply supported strips: , so .
- Moments: and .
- .
Answer: (D) . The short span carries the larger moment.
Trap: (C) inverts the ratio, and stopping at the load share gives the fourth power. These are the strip ideas behind the IS 456 Annex D-2 / Table 27 coefficients for torsionally unrestrained slabs.
For simply supported slabs with free corners, designers read the alpha-x and alpha-y coefficients from IS 456 Table 27, which follow this strip split; the bigger short-span moment is why short-span bars go in the outer layer of the slab mat.
Column with neutral axis at 1.1D (outside the section): maximum compressive strain in concrete
A concrete column section of size 300 mm 500 mm as shown in the figure is subjected to both axial compression and bending along the major axis. The depth of the neutral axis () is 1.1 times the depth of the column, as shown.
(Figure NOT to scale)
The maximum compressive strain () at highly compressive extreme fiber in concrete, where there is no tension in the section, is ________ (rounded off to 2 decimal places).
Answer: Official key: 3.20 to 3.40
- The neutral axis is outside the section (), so the whole section is in compression and the 0.0035 limit no longer applies.
- IS 456 Cl. 39.1(b): the strain at the highly compressed fibre is (strain at the least compressed fibre). Equivalently, every strain line passes through at from the highly compressed fibre.
- . Similar triangles from the neutral axis: .
- . Check: bottom strain and .
Answer: .
Trap: writing (the flexure limit, valid only while ) or (pure axial compression, ). With the answer lies between them.
This strain rule is how every P-M interaction curve is generated for column design: ETABS, SP 16 charts and in-house spreadsheets sweep xu past D using the 3D/7 pivot to get the high-axial-load part of the curve that governs heavily loaded ground-floor columns.
Two-way slab with continuous edges (IS 456): what decides the longitudinal steel in the edge strip?
- (A)the calculated minimum bending moment
- (B)the area of longitudinal steel provided in the middle strip in the shorter span
- (C)the area of longitudinal steel provided in the middle strip in the longer span
- (D)the prescribed minimum cross-sectional area of longitudinal steel for slabs
Answer: (D) Official key: D
- IS 456 Annex D treats a restrained two-way slab by dividing it in each direction into a middle strip (the central three-quarters of the width) and two edge strips (one-eighth of the width each), Cl. D-1.2.
- The Table 26 coefficients give and , and Cl. D-1.3 says these moments apply only to the middle strips. No bending moment is calculated for an edge strip, so (A) has nothing to be based on.
- Cl. D-1.7: reinforcement in the edge strip, parallel to that edge, shall comply with the minimum given in Section 3, i.e. Cl. 26.5.2.1: of the gross area for HYSD bars ( for mild steel). Corner torsion steel (Cl. D-1.8 to D-1.10) is added on top of that.
- So the edge-strip steel is the prescribed minimum area of steel for slabs, option (D).
Trap: options (B) and (C) suggest the edge strip copies the middle-strip steel. The middle-strip steel only enters the corner torsion mesh (three-quarters of the short-span mid-span steel at a corner with both edges discontinuous), never the edge-strip bars themselves.
Slab detailing drawings show this directly: the middle strips get the designed bars at the designed spacing, while the outer one-eighth bands carry nominal 0.12% steel plus the top and bottom corner mesh. Slab design spreadsheets and RCDC-type tools follow the same middle/edge strip split.
Slab bars changed from 10 mm at 150 mm c/c to 12 mm bars: what spacing resists the same design moment?
Answer: Official key: 214 to 218
- A slab is designed per metre width. Bars of diameter at spacing give per metre.
- Same design moment, same steel grade and (practically) the same effective depth means the same lever arm, so the required does not change: .
- Keep constant: .
- Detailing check, IS 456 Cl. 26.3.3(b)(1): main bars in a slab must be spaced at most or 300 mm, whichever is less; 216 mm is below 300 mm. Answer: .
Trap: scaling the spacing linearly with the diameter, . Bar area goes with , so a 20 % larger bar carries 44 % more steel and can be spaced 44 % wider.
On site this is a routine bar substitution: when 10 mm bars run out, the contractor asks the design office to approve, say, 12 mm bars at a wider spacing, and the engineer revises the bar bending schedule after checking the maximum spacing and crack-width limits.
Average elastic shortening loss when three post-tensioned tendons are stressed one after another
A post-tensioned concrete member of span 15 m and cross-section of 450 mm 450 mm is prestressed with three steel tendons, each of cross-sectional area 200 mm2. The tendons are tensioned one after another to a stress of 1500 MPa. All the tendons are straight and located at 125 mm from the bottom of the member. Assume the prestress to be the same in all tendons and the modular ratio to be 6. The average loss of prestress, due to elastic deformation of concrete, considering all three tendons is
- (A)14.16 MPa
- (B)7.08 MPa
- (C)28.32 MPa
- (D)42.48 MPa
Answer: (A) 14.16 MPa Official key: A
- Force in one tendon: . Section: , , eccentricity mm.
- Concrete stress at tendon level caused by one tendon: .
- Each later tendon shortens the concrete and drops an already-anchored tendon by MPa. In post-tensioning the tendon being stressed suffers no loss (the jack makes up for it).
- Tendon 1 loses MPa, tendon 2 loses 14.16 MPa, tendon 3 loses 0.
- Average: MPa. Answer: (A) 14.16 MPa
Trap: (C) 28.31 MPa is the loss of the first tendon only, and (D) 42.47 MPa is the total of the three losses without dividing by 3. Leaving out the term (tendons below the centroid) gives 8.89 MPa, which matches no option.
PT designers specify the stressing sequence on the drawings, and software such as ADAPT-PT or RAM Concept computes the elastic shortening of earlier tendons this way; on long girders the first tendons are often re-stressed to recover the loss.
Inverted T beam prestressed at the bottom kern: additional cracking moment over a plain beam
An inverted T-shaped concrete beam (B1) in the figure, with centroidal axis , is subjected to an effective prestressing force of 1000 kN acting at the bottom kern point of the beam cross-section. Also consider an identical concrete beam (B2) with the same grade of concrete but without any prestressing force.
(Figure NOT to scale)
The additional cracking moment (in kN.m) that can be carried by beam B1 in comparison to beam B2 is ________ (rounded off to the nearest integer).
Answer: Official key: 299 to 301
- Kern distances: (bottom kern, below the centroid) and (top kern, above it), with .
- From the figure and , so . With : .
- Prestress at the bottom kern () gives zero stress at the top and a bottom precompression .
- Both beams crack when the bottom tension reaches the same modulus of rupture, so B1 carries extra moment .
- .
Answer: .
Trap: taking only the eccentric moment . The axial part also precompresses the bottom fibre; it is worth here.
Precast inverted-T ledger beams carry hollow-core planks on their flanges; the prestressing designer checks the cracking moment as P(kt + e) plus fcrZb for the IS 1343 Type 1/Type 2 limits and for the minimum-steel rule that the ultimate moment must exceed the cracking moment.
Which methods check prestressed concrete flexural stresses at transfer and at service?
- (A)Limiting zone for prestressing
- (B)Magnel’s graph
- (C)Hoyer effect
- (D)Load balancing method
Answer: (A) and (B) Official key: A;B
- Four stress conditions govern a prestressed beam: top and bottom fibre stresses at transfer (initial prestress plus self-weight) and at service (effective prestress plus full load) must stay within the IS 1343 permissible compression and tension.
- (A) Limiting zone (Guyon): writing those four conditions for the cable eccentricity gives an upper and a lower limit for at every section. A cable inside that zone satisfies all four limits. Correct.
- (B) Magnel's graph: each condition, for example , is a straight line in versus . The region between the four lines gives every safe pair . Correct.
- (C) Hoyer effect: after release a pretensioned wire swells back at the beam end (Poisson effect) and wedges into the concrete. It explains bond and transmission length, not flexural stresses. Wrong.
- (D) Load balancing (T. Y. Lin) picks the prestress so the cable's upward force balances a chosen load. It is an analysis idea, not a check of the transfer and service stress limits. Wrong.
Answer: (A) and (B). Trap: ticking (D) because load balancing also gives stresses. It only gives them under the unbalanced load, so it does not check both stages.
Magnel diagrams are still how bridge engineers size the prestress and eccentricity of precast pretensioned I-girders before running the full stage-wise stress check in MIDAS Civil or RM Bridge; the limiting zone is then used to set the tendon profile along the span.
Prestressed beam 250 × 600 mm with four 14 mm tendons at 700 MPa: maximum moment with no tension at soffit
A 250 mm wide × 600 mm deep rectangular concrete beam is prestressed by means of 4 high-tensile tendons, each of 14 mm diameter. The centre of the tendons is 200 mm from the soffit of the beam. The effective stress in each tendon is 700 N/mm2.
The maximum bending moment (in kN-m), that can be applied to the section without causing tension at the soffit of the beam due to prestressing only, is ______ (rounded off to one decimal place).
Use
Answer: Official key: 85.50 to 87.60
- Tendon area ; prestress .
- Section: , , eccentricity .
- Prestress at the soffit (compression): .
- A sagging moment from the external load adds tension at the soffit and so eats into that stored compression. The largest moment the beam can take before the soffit goes into tension is the one that brings it exactly to zero stress: , i.e. .
Shortcut: , the prestress times its distance from the upper kern point, . Trap: forgetting the axial term gives , half the answer.
This decompression moment is what makes a member a Type 1 (no tension) member under IS 1343. Designers of precast pretensioned beams and hollow-core slabs compare it with the service moment, and it is the first number checked when a precast supplier's design is reviewed.