GATE Civil: Environmental Engineering (water quality, BOD, water and wastewater treatment, sludge, air pollution, solid waste), previous-year questions solved

Every environmental engineering question from the ten official GATE Civil papers of 2022-2026: 69 questions (25 NAT, 25 MCQ, 19 MSQ) on water quality and BOD, water supply and treatment, wastewater and sludge, air pollution and solid waste, each solved step by step and checked by a script against the official key. GATE 2027 adds tertiary treatment, sludge treatment and landfill basics to the syllabus.

Questions from the ten official GATE CE papers, sessions CE1 and CE2 of GATE 2022 (IIT Kharagpur), 2023 (IIT Kanpur), 2024 (IISc Bengaluru), 2025 (IIT Roorkee) and 2026 (IIT Guwahati); solutions by Skill-Lync. · Updated 17 Nov 2026 · 31 of 69 questions on this page

GATE 2022 · CE1 · Q.22MCQ · 1 markWater quality, BOD and stream pollution

How many milligram equivalents per litre is a total hardness of 500 mg/L as CaCO3?

The total hardness in raw water is 500 milligram per liter as CaCO3. The total hardness of this raw water, expressed in milligram equivalent per liter, is

(Consider the atomic weights of Ca, C, and O as 40 g/mol, 12 g/mol, and 16 g/mol, respectively.)

  1. (A)10
  2. (B)100
  3. (C)1
  4. (D)5

Answer: (A) 10 meq/L Official key: A

  1. Molar mass of CaCO3 g/mol.
  2. Its valence (charge of Ca2+) is 2, so the equivalent weight is mg per meq.
  3. Hardness in meq/L , so (A) 10 meq/L.
  4. Conversion rule worth remembering: 1 meq/L of hardness = 50 mg/L as CaCO3, whatever ions cause it.

Trap: dividing by the molar mass (100) gives 5, option (D); that is millimoles per litre, not milliequivalents. A divalent ion carries two equivalents per mole.

Where this shows up in industry

IS 10500:2012 sets an acceptable limit of 200 mg/L and a permissible limit of 600 mg/L of total hardness as CaCO3 for drinking water, so this raw water would need softening or blending.

GATE 2022 · CE1 · Q.26MSQ · 1 markWater quality, BOD and stream pollution

COD and BOD5 of wastewater from a wood pulping industry: which relations hold

For wastewater coming from a wood pulping industry, Chemical Oxygen Demand (COD) and 5-day Biochemical Oxygen Demand (BOD5) were determined. For this wastewater, which of the following statement(s) is/are correct?

  1. (A)COD > BOD5
  2. (B)COD ≠ BOD5
  3. (C)COD < BOD5
  4. (D)COD = BOD5

Answer: (A, B) Official key: A, B

  1. COD oxidises almost all organic matter chemically (boiling dichromate), biodegradable or not. BOD measures only what microbes oxidise, and BOD5 only the part exerted in 5 days.
  2. So for any wastewater, COD is at least the ultimate BOD, which in turn exceeds BOD5. Pulping wastewater carries lignin and fibre that bacteria barely break down, so the gap is large.
  3. Example: COD 1000 mg/L with 30 percent biodegradable organics and per day gives ultimate BOD 300 mg/L and BOD5 205 mg/L.
  4. COD > BOD5 is true (A), and therefore COD ≠ BOD5 is also true (B). (C) and (D) are false. Answer: (A) and (B).

Trap: ticking only (A). Statement (B) is weaker but still correct, and an MSQ needs every true option.

Where this shows up in industry

A low BOD5 to COD ratio, typical of pulp and paper effluent, tells the designer that biological treatment alone will not meet the CPCB general discharge standards of 30 mg/L BOD and 250 mg/L COD.

GATE 2022 · CE1 · Q.42MCQ · 2 marksWater quality, BOD and stream pollution

Henry's law constant 1.3 mmol per litre-atm, oxygen partial pressure 0.21 atm: saturation DO in mg/L

Henry’s law constant for transferring O2 from air into water, at room temperature, is 1.3 mmol/(liter-atm). Given that the partial pressure of O2 in the atmosphere is 0.21 atm, the concentration of dissolved oxygen (mg/liter) in water in equilibrium with the atmosphere at room temperature is

(Consider the molecular weight of O2 as 32 g/mol)

  1. (A)8.7
  2. (B)0.8
  3. (C)198.1
  4. (D)0.2

Answer: (A) 8.7 mg/L Official key: A

  1. Henry's law with the constant in concentration per pressure: .
  2. mmol/L of dissolved O2.
  3. Convert to mass: mg/L, so (A) 8.7 mg/L.
  4. Sense check: saturation DO in fresh water is about 9 mg/L at 20 to 25 C, so the answer is in the expected band.

Trap: reading the units backwards and dividing, , gives 198.1 mg/L, option (C). Look at the units of : mmol per litre per atm, so multiply by atm.

Where this shows up in industry

This saturation value is the ceiling against which river oxygen is judged; CPCB's primary water quality criteria for outdoor bathing ask for at least 5 mg/L of dissolved oxygen.

GATE 2022 · CE1 · Q.43MCQ · 2 marksWater quality, BOD and stream pollution

Ca 100 mg/L, Mg 36 mg/L, HCO3 122 mg/L: total and temporary hardness as CaCO3

In a water sample, the concentrations of Ca2+, Mg2+ and HCO3- are 100 mg/L, 36 mg/L and 122 mg/L, respectively. The atomic masses of various elements are: Ca = 40, Mg = 24, H = 1, C = 12, O = 16.

The total hardness and the temporary hardness in the water sample (in mg/L as CaCO3) will be

  1. (A)400 and 100, respectively.
  2. (B)400 and 300, respectively.
  3. (C)500 and 100, respectively.
  4. (D)800 and 200, respectively.

Answer: (A) 400 and 100 mg/L as CaCO3 Official key: A

  1. Convert each ion to CaCO3 with (mg/L) 50 / (its equivalent weight). Equivalent weights: Ca 40/2 = 20, Mg 24/2 = 12, HCO3- 61/1 = 61.
  2. Ca: ; Mg: . Total hardness mg/L as CaCO3.
  3. Alkalinity from bicarbonate: mg/L as CaCO3.
  4. Temporary (carbonate) hardness is the smaller of total hardness and alkalinity: mg/L. The remaining 300 mg/L is permanent hardness.
  5. Answer: (A) 400 and 100.

Trap: using 100 instead of 50 in the conversion doubles everything and gives 800 and 200, option (D). And (B) swaps in the permanent hardness, 300, for the temporary one.

Where this shows up in industry

This split decides the softening chemistry: lime alone removes carbonate hardness, while the permanent part needs soda ash as well, which is how lime-soda softening doses are worked out.

GATE 2022 · CE1 · Q.59NAT · 2 marksWater quality, BOD and stream pollution

Wastewater with 34 mg NH3/L and 6.2 mg NO3/L: total nitrogen in mg N/L

A wastewater sample contains two nitrogen species, namely ammonia and nitrate. Consider the atomic weight of N, H, and O as 14 g/mol, 1 g/mol, and 16 g/mol, respectively. In this wastewater, the concentration of ammonia is 34 mg NH3/liter and that of nitrate is 6.2 mg NO3-/liter. The total nitrogen concentration in this wastewater is _______ milligram nitrogen per liter. (round off to one decimal place)

Answer: mg N/L Official key: 29.0 to 30.0

  1. Express each species as nitrogen by multiplying by the mass fraction of N in it.
  2. Ammonia, NH3 = 17 g/mol: mg N/L.
  3. Nitrate, NO3- = 62 g/mol: mg N/L.
  4. Total nitrogen 29.4 mg N/L (key 29.0 to 30.0).

Trap: adding the raw concentrations, , or converting only the ammonia and adding 6.2 (34.2) both fall outside the key. Concentrations of different species can only be added once they are on a common basis.

Where this shows up in industry

Mixing bases causes real errors: IS 10500:2012 limits nitrate in drinking water to 45 mg/L as NO3, which is only about 10 mg/L as nitrogen.

GATE 2022 · CE1 · Q.60NAT · 2 marksWater quality, BOD and stream pollution

2 percent sewage dilution, 10 mg/L DO depletion in 3 days at 27 C, k 0.23 per day: ultimate BOD

A 2 % sewage sample (in distilled water) was incubated for 3 days at 27 °C temperature. After incubation, a dissolved oxygen depletion of 10 mg/L was recorded. The biochemical oxygen demand (BOD) rate constant at 27 °C was found to be 0.23 day-1 (at base e).

The ultimate BOD (in mg/L) of the sewage will be_____________. (round off to the nearest integer)

Answer: mg/L Official key: 1000 to 1005

  1. A 2 percent sample means a dilution fraction , so the BOD of the sewage itself is mg/L.
  2. First-order BOD: with per day (base e) and days.
  3. .
  4. mg/L, so 1003 mg/L (key 1000 to 1005). About half the ultimate demand is exerted in the first 3 days.

Trap: forgetting the dilution gives 20 mg/L, and using base 10, , gives 628 mg/L; both are outside the key. The question says base e for a reason.

Where this shows up in industry

Indian practice runs exactly this test: BOD is reported as the 3-day value at 27 C (IS 3025 Part 44), and the CPCB general standard for discharge into inland surface water is 30 mg/L on that basis.

GATE 2022 · CE2 · Q.42MCQ · 2 marksWater quality, BOD and stream pollution

100 mg of HNO3, a strong acid, made up to 1 litre: final pH

A 100 mg of HNO3 (strong acid) is added to water, bringing the final volume to 1.0 liter. Consider the atomic weights of H, N, and O, as 1 g/mol, 14 g/mol, and 16 g/mol, respectively. The final pH of this water is

(Ignore the dissociation of water.)

  1. (A)2.8
  2. (B)6.5
  3. (C)3.8
  4. (D)8.5

Answer: (A) 2.8 Official key: A

  1. Molar mass of HNO3 g/mol.
  2. Moles in 1 L: mmol, i.e. mol/L.
  3. A strong acid dissociates completely, so M.
  4. , so (A) 2.8.

Trap: taking the natural logarithm instead of log base 10 gives 6.45, which rounds to option (B); and (B) and (D) are just the 6.5 and 8.5 limits of drinking water pH, put there to catch guessers.

Where this shows up in industry

IS 10500:2012 requires drinking water pH between 6.5 and 8.5, so even 100 mg/L of a strong acid makes water unfit; alkalinity in natural water normally buffers small acid inputs like this.

GATE 2023 · CE1 · Q.27MSQ · 1 markWater quality, BOD and stream pollution

Waterborne diseases caused by viral pathogens: polio, cholera, infectious hepatitis, typhoid

Identify the waterborne diseases caused by viral pathogens:

  1. (A)Acute anterior poliomyelitis
  2. (B)Cholera
  3. (C)Infectious hepatitis
  4. (D)Typhoid fever

Answer: (A) and (C) Official key: A;C

  1. Sort each disease by the organism that causes it.
  2. Acute anterior poliomyelitis is caused by the poliovirus, an enterovirus spread by the faecal-oral route, including through contaminated water: viral.
  3. Cholera is caused by the bacterium Vibrio cholerae: bacterial.
  4. Infectious hepatitis (hepatitis A, and in Indian outbreaks often hepatitis E) is caused by viruses shed in faeces and carried by sewage-contaminated water: viral.
  5. Typhoid fever is caused by the bacterium Salmonella Typhi: bacterial.
  6. Answer: (A) and (C).

Trap: ticking cholera because it is the classic waterborne epidemic. It is waterborne, but bacterial; the question asks for viral pathogens only.

Where this shows up in industry

Viruses are smaller and more resistant to chlorine than most bacteria, which is why IS 10500:2012 asks for a free chlorine residual of at least 0.2 mg/L at the tap and why coliform counts are only an indicator, not proof of virus-free water.

GATE 2023 · CE2 · Q.48MSQ · 2 marksWater quality, BOD and stream pollution

Water and wastewater statements: particle shielding, ammonia and chlorine demand, phosphorus, hardness and TDS

In the context of water and wastewater treatments, the correct statements are:

  1. (A)particulate matter may shield microorganisms during disinfection
  2. (B)ammonia decreases chlorine demand
  3. (C)phosphorous stimulates algal and aquatic growth
  4. (D)calcium and magnesium increase hardness and total dissolved solids

Answer: (A) and (C) and (D) Official key: A;C;D

  1. (A) True. Microorganisms embedded in or attached to particles are protected from the disinfectant, which is why turbidity is removed before chlorination or UV.
  2. (B) False. Chlorine reacts with ammonia to form chloramines and then destroys them; breakpoint takes about mg of Cl2 per mg of NH3-N. So 0.5 mg/L of ammonia nitrogen adds about mg/L to the chlorine demand: ammonia increases it.
  3. (C) True. Phosphorus is usually the limiting nutrient in fresh water; discharging it causes algal blooms and eutrophication.
  4. (D) True. Hardness is the sum of divalent cations, mainly Ca2+ and Mg2+, and being dissolved they also add to total dissolved solids.
  5. Answer: (A), (C) and (D).

Trap: thinking ammonia 'protects' chlorine because chloramines last longer. They persist, but forming them uses up chlorine, so demand goes up.

Where this shows up in industry

IS 10500:2012 sets total hardness at 200 mg/L as CaCO3 acceptable and 600 mg/L permissible without an alternative source, and TDS at 500 and 2000 mg/L; both are routinely high in groundwater across Rajasthan and other hard-rock regions.

GATE 2023 · CE2 · Q.64NAT · 2 marksWater quality, BOD and stream pollution

Biomass C5H7O2N oxidised with k = 0.23 per day: ratio of BOD5 to total organic carbon

The theoretical aerobic oxidation of biomass (C5H7O2N) is given below:

C5H7O2N + 5O2 → 5CO2 + NH3 + 2H2O

The biochemical oxidation of biomass is assumed as a first-order reaction with a rate constant of 0.23/d at 20°C (logarithm to base e). Neglecting the second-stage oxygen demand from its biochemical oxidation, the ratio of BOD5 at 20°C to total organic carbon (TOC) of biomass is ________ (round off to two decimal places).

[Consider the atomic weights of C, H, O and N as 12 g/mol, 1 g/mol, 16 g/mol and 14 g/mol, respectively]

Answer: 1.82 Official key: 1.80 to 2.00

  1. Per mole of biomass ( g), the first-stage (carbonaceous) oxygen demand is 5 mol of O2: ultimate BOD g. The NH3 released would need more oxygen for nitrification, but that second stage is excluded.
  2. First order: g.
  3. Organic carbon per mole: g.
  4. , so 1.82 (key 1.80 to 2.00).

Trap: using the ultimate BOD instead of BOD5 gives , and treating 0.23/d as a base-10 constant gives ; the question says natural logarithm.

Where this shows up in industry

Online TOC analysers give a result in minutes against five days for a BOD test, so treatment plants build a site-specific BOD-to-TOC correlation like this ratio and use TOC for day-to-day process control.

GATE 2023 · CE2 · Q.65NAT · 2 marksWater quality, BOD and stream pollution

Seven river segments with complete mixing and a withdrawal: steady concentration of a conservative pollutant in R7

A system of seven river segments is shown in the schematic diagram. The 's, 's, and 's ( to 7) are the river segments, their corresponding flow rates, and concentrations of a conservative pollutant, respectively. Assume complete mixing at the intersections, no additional water loss or gain in the system, and steady state condition. Given: m3/s; m3/s; m3/s; m3/s; kg/m3; kg/m3; kg/m3. What is the steady state concentration (in kg/m3, rounded off to two decimal place) of the pollutant in the river segment 7? ________

Seven river segments: R1 and R2 join into R3, R4 is drawn off, R6 joins, R7 leavesR1R2R3R4R5R6R7R4 leaves the junction (withdrawal); R6 joins it

Answer: 10.68 kg/m3 Official key: 10.58 to 10.78

  1. A conservative pollutant is not created or destroyed, so at each junction flow and mass flux both balance: .
  2. Junction 1 (R1 + R2 into R3): , .
  3. Junction 2: R4 is drawn off (its arrow leaves the junction). A withdrawal takes the same mixed concentration, so and .
  4. Junction 3 (R5 + R6 into R7): , , so 10.68 kg/m3 (key 10.58 to 10.78).

Trap: averaging the three given concentrations gives , and treating R4 as an inflow of clean water gives ; both miss the key. Ignoring the withdrawal altogether gives , which happens to fall inside the wide key, but the balance above is the correct one.

Where this shows up in industry

River water quality models such as QUAL2K, used for pollution load allocation and in CPCB-style river action plans, are chains of exactly these mass balances at every confluence, outfall and abstraction point, with decay terms added for non-conservative pollutants like BOD.

GATE 2025 · CE1 · Q.44MSQ · 2 marksWater quality, BOD and stream pollution

MgCl2 and CaSO4 dissolved to give TDS 500 mg/l and total hardness 400 mg/l as CaCO3: amounts added

MgCl2 and CaSO4 salts are added to 1 litre of distilled deionized water and mixed until completely dissolved. Total Dissolved Solids (TDS) concentration is 500 mg/l, and Total Hardness (TH) is 400 mg/l (as CaCO3). The amounts of MgCl2 and CaSO4 added are calculated (rounded off to the nearest integer). Which of the following options is/are true:

Atomic weights: Ca(40), Mg(24), S(32), O(16), Cl(35.5), C(12)

  1. (A)Amount of MgCl2 added is 143 mg
  2. (B)Amount of CaSO4 added is 357 mg
  3. (C)Amount of MgCl2 added is 103 mg
  4. (D)Amount of CaSO4 added is 397 mg

Answer: (C) and (D) Official key: C;D

  1. Let mg of (molar mass 95) and mg of (molar mass 136) be added. All of it dissolves, so TDS gives .
  2. Both are divalent salts, so one mole of either gives one mole of hardness, worth 100 mg as : .
  3. Substitute : , so mg and mg.
  4. The closest options are 103 mg and 397 mg; check: they give TH = mg/l. Answer: (C) and (D), the official key.

Trap: the other pair, 143 mg and 357 mg, also adds up to 500 mg but gives mg/l; always check both conditions, not just the TDS total.

Where this shows up in industry

IS 10500:2012 sets acceptable limits of 500 mg/l for TDS and 200 mg/l as CaCO3 for total hardness in drinking water, with higher permissible limits only where no alternative source exists; water like this sample would need softening.

GATE 2025 · CE2 · Q.49MSQ · 2 marksWater quality, BOD and stream pollution

Compound CaHbOcNd, molecular weight 187, 935 mg/l with TOC 360, COD 600, TKN 140 mg/l: find a, b, c, d

A compound has a general formula CaHbOcNd and molecular weight 187. A 935 mg/l solution of the compound is prepared in distilled deionized water. The Total Organic Carbon (TOC) is measured as 360 mg/l (as C). The Chemical Oxygen Demand (COD) and the Total Kjeldahl Nitrogen (TKN) are determined as 600 mg/l (as O2) and 140 mg/l (as N), respectively (as per the chemical equation given below). Which of the following options is/are CORRECT?

Atomic weight: C(12), H(1), O(16), N(14)

  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (A) and (B) and (C) Official key: A;B;C

  1. Moles of compound: mmol/l.
  2. TOC: mmol C per litre, so . TKN: mmol N, so .
  3. COD: mmol , i.e. mol per mol, so , giving .
  4. Molecular weight: , so .
  5. Subtract: , , . The compound is .
  6. Answer: (A), (B) and (C); (D) is false since .

Trap: forcing makes the same two equations give , not a whole number, so (D) cannot be right.

Where this shows up in industry

Plants track COD, TOC and TKN together: the COD to TOC ratio shows how oxidised the organic load is, and TKN sets the nitrification oxygen demand when an aeration tank is sized for ammonia removal under the CPCB discharge standards.

GATE 2025 · CE2 · Q.61NAT · 2 marksWater quality, BOD and stream pollution

Ion analysis with Ca, Mg, Fe, Na, K, CO3, HCO3 and Cl as CaCO3: non-carbonate hardness

The analyses results of a water sample are given below. The non-carbonate hardness of the water (in mg/L) as CaCO3 is ______ (in integer).

Ca2+ = 150 mg/L as CaCO3
Mg2+ = 40 mg/L as CaCO3
Fe2+ = 10 mg/L as CaCO3
Na+ = 50 mg/L as CaCO3
K+ = 10 mg/L as CaCO3
CO32- = 120 mg/L as CaCO3
HCO3- = 30 mg/L as CaCO3
Cl- = 50 mg/L as CaCO3; Other anions were not analysed.

Answer: as CaCO3 Official key: 50 to 50

  1. Hardness is caused by divalent metal cations: , and also . Total hardness mg/L as . and are not hardness.
  2. Alkalinity (here carbonate plus bicarbonate) mg/L as .
  3. Carbonate hardness is the smaller of TH and alkalinity: mg/L.
  4. Non-carbonate hardness mg/L as (key 50).

Trap: leaving out gives mg/L. The ion balance does not close because some anions were not analysed, so do not try to get NCH from the chloride alone.

Where this shows up in industry

Lime-soda softening doses follow this split: lime removes carbonate hardness, while non-carbonate hardness needs soda ash as well; IS 10500:2012 sets 200 mg/l as CaCO3 as the acceptable limit for total hardness.

GATE 2026 · CE1 · Q.44MCQ · 2 marksWater quality, BOD and stream pollution

City sewage 90 MLD at BOD5 300 mg/l, standard 0.08 kg BOD5 per person per day: population equivalent

The average sewage from a city is 90 million litres per day and the average 5-day Biochemical Oxygen Demand (BOD5) is 300 mg/l. Average standard BOD5 of the domestic sewage is 0.08 kg/day/person. The population equivalent of the city is

  1. (A)337500
  2. (B)216000
  3. (C)270000
  4. (D)168750

Answer: (A) 337500 Official key: A

  1. Daily BOD5 load: mg/day kg/day.
  2. Population equivalent is the number of people whose standard per-capita BOD adds up to this load: .
  3. , answer (A).

Trap: rounding the per-capita BOD up to 0.1 kg/day gives , option (C); use the 0.08 kg/day/person the question gives, and watch the mg to kg conversion ( mg per kg).

Where this shows up in industry

Population equivalent lets an engineer express an industrial or city-wide organic load as a number of residents, so trade effluents can be added to the design population when a sewage treatment plant is sized or charged for.

GATE 2026 · CE2 · Q.42MCQ · 2 marksWater quality, BOD and stream pollution

2.4 ml of raw sewage diluted to 240 ml, DO 8 mg/l initially and 6 mg/l after 5 days: BOD5

The 2.4 ml of raw sewage is diluted to 240 ml. The Dissolved Oxygen (DO) of the diluted sample at the beginning of Biochemical Oxygen Demand (BOD) test was 8 mg/l and it was 6 mg/l after 5-day incubation at 20 °C.

The BOD5 (in mg/l) of the raw sewage is

  1. (A)200
  2. (B)100
  3. (C)250
  4. (D)150

Answer: (A) 200 Official key: A

  1. The oxygen used in the bottle is mg/l of diluted sample.
  2. Only a fraction of the bottle is sewage: .
  3. mg/l, answer (A).
  4. The reading is a valid one: the bottle used at least 2 mg/l of oxygen and kept at least 1 mg/l, the usual acceptance limits for a dilution BOD test.

Trap: dividing the final DO instead of the depletion by gives mg/l, not an option; the BOD is the oxygen consumed, so both DO readings are needed.

Where this shows up in industry

The 5-day, 20 degree C dilution BOD test is the basis of Indian discharge standards for sewage treatment plants, which set the BOD a plant's treated effluent may carry into a river or onto land.

GATE 2022 · CE1 · Q.27MSQ · 1 markWater supply and treatment

Which processes can convert salt water into fresh water?

Which of the following process(es) can be used for conversion of salt water into fresh water?

  1. (A)Microfiltration
  2. (B)Electrodialysis
  3. (C)Ultrafiltration
  4. (D)Reverse osmosis

Answer: (B, D) Official key: B, D

  1. Desalting means removing dissolved ions such as Na+ and Cl-, which are well under 1 nm across.
  2. Microfiltration (pores about 0.1 micron) and ultrafiltration (about 0.01 micron) strain out suspended solids, bacteria and large molecules, but dissolved salts pass straight through. (A) and (C) are false.
  3. Electrodialysis drives ions through alternating cation- and anion-exchange membranes with an electric field, leaving desalted water between them: (B) true.
  4. Reverse osmosis pushes water through a dense membrane against the osmotic pressure, about 30 bar for 35 g/L of NaCl, and holds the salt back: (D) true.
  5. Answer: (B) and (D).

Trap: ticking ultrafiltration because it is a fine membrane. Fine is not fine enough: only RO and nanofiltration membranes, or ion-exchange processes, reject ions.

Where this shows up in industry

Chennai's seawater desalination plants at Minjur and Nemmeli use reverse osmosis, while electrodialysis is used more for brackish groundwater, where the lower salt load keeps the electrical cost down.

GATE 2022 · CE1 · Q.61NAT · 2 marksWater supply and treatment

Basin 3 m deep, 5 m wide, 40 m long, 500 m3/h: removal fraction of particles settling at 1.0 m/h

A water treatment plant has a sedimentation basin of depth 3 m, width 5 m, and length 40 m. The water inflow rate is 500 m3/h. The removal fraction of particles having a settling velocity of 1.0 m/h is_______. (round off to one decimal place)

(Consider the particle density as 2650 kg/m3 and liquid density as 991 kg/m3)

Answer: Official key: 0.38 to 0.42

  1. In an ideal settling basin, a particle is fully removed if its settling velocity reaches the surface overflow rate .
  2. m/h.
  3. Slower particles are removed in proportion: fraction .
  4. Check with detention time: h, in which a particle sinks 1.2 m of the 3 m depth, again . Answer: 0.4 (key 0.38 to 0.42).
  5. The densities are not needed: the settling velocity is already given.

Trap: dividing the flow by the cross-section (5 x 3 m) gives a horizontal velocity, not the overflow rate, and a removal of 0.03; inverting the ratio gives 2.5, which is not a fraction at all.

Where this shows up in industry

Because removal depends on surface area and not depth, tube settlers and lamella plates are added to existing clarifiers to multiply the settling area and raise their capacity without new tanks.

GATE 2023 · CE1 · Q.45MCQ · 2 marksWater supply and treatment

Match reverse osmosis, trickling filter, coagulation and adsorption with their characteristic phenomena

In the following table, identify the correct set of associations between the entries in Column-1 and Column-2.

Column-1Column-2
P: Reverse OsmosisI: Ponding
Q: Trickling FilterII: Freundlich Isotherm
R: CoagulationIII: Concentration Polarization
S: AdsorptionIV: Charge Neutralization

Choose one option.

  1. (A)P-II, Q-I, S-III
  2. (B)Q-III, R-II, S-IV
  3. (C)P-IV, R-I, S-II
  4. (D)P-III, Q-I, R-IV

Answer: (D) P-III, Q-I, R-IV Official key: D

  1. Reverse osmosis: water passes the membrane and the rejected salts pile up in a thin layer at its surface. That layer of higher concentration raises the osmotic pressure to overcome and cuts the flux: concentration polarization, P-III.
  2. Trickling filter: excess biological slime growth, or debris, clogs the voids in the filter media and wastewater collects on the surface: ponding, Q-I.
  3. Coagulation: colloids carry a negative surface charge that keeps them apart; added Al3+ or Fe3+ species neutralise it so particles can collide and stick: charge neutralization, R-IV.
  4. Adsorption: the equilibrium between adsorbed and dissolved solute is described by isotherms such as Freundlich and Langmuir: S-II.
  5. Only option (D) lists three pairs that are all correct.

Trap: (A) pairs RO with the Freundlich isotherm because both deal with dissolved solutes, but an isotherm describes adsorption on a surface, not rejection by a membrane.

Where this shows up in industry

RO plants, including the large seawater desalination plants near Chennai, run cross-flow past the membranes and limit recovery per stage precisely to keep concentration polarization and the scaling it causes under control.

GATE 2023 · CE1 · Q.63NAT · 2 marksWater supply and treatment

Flocculator of 2800 m3 at G = 100 per s: decrease in G when the water cools from 15 C to 5 C at the same power

A flocculator tank has a volume of 2800 m3. The temperature of water in the tank is 15°C, and the average velocity gradient maintained in the tank is 100/s. The temperature of water is reduced to 5°C, but all other operating conditions including the power input are maintained as the same. The decrease in the average velocity gradient (in %) due to the reduction in water temperature is ________ (round off to nearest integer).

[Consider dynamic viscosity of water at 15°C and 5°C as 1.139×10-3 N-s/m2 and 1.518×10-3 N-s/m2, respectively]

Answer: 13 % Official key: 12 to 15

  1. Camp-Stein velocity gradient: .
  2. Power at 15 C: W.
  3. Same and at 5 C: . Equivalently .
  4. Decrease %, so 13 % (key 12 to 15). The tank volume cancels out.

Trap: forgetting the square root and using the viscosity ratio directly gives %; dividing the change by the new instead of the original gives %; both are outside the key.

Where this shows up in industry

Because cold water is more viscous, the same paddle power gives gentler mixing in winter; designers therefore check flocculators at the lowest expected water temperature and specify G and the product Gt, as in the CPHEEO manual, rather than just paddle speed.

GATE 2023 · CE2 · Q.29MSQ · 1 markWater supply and treatment

Which of hydroxyl radical, ozone, hypochlorite ion and chloride ion is not an active disinfectant

Which of the following is/are NOT active disinfectant(s) in water treatment?

  1. (A)•OH (hydroxyl radical)
  2. (B)O3 (ozone)
  3. (C)OCl− (hypochlorite ion)
  4. (D)Cl− (chloride ion)

Answer: (D) Official key: D

  1. Chemical disinfectants kill microorganisms by oxidising cell walls, enzymes and nucleic acids, so an active disinfectant must be a strong oxidant.
  2. (A) The hydroxyl radical is the strongest oxidant used in water treatment; it is the working species of advanced oxidation (ozone with hydrogen peroxide or UV): active.
  3. (B) Ozone is a powerful disinfectant, effective even against viruses and cysts: active.
  4. (C) The hypochlorite ion is part of free available chlorine (with HOCl). It is a weaker disinfectant than HOCl, which is why chlorination works better at lower pH, but it is still active.
  5. (D) The chloride ion is chlorine already fully reduced, the end product after chlorine has done its work. It has no oxidising power: not a disinfectant.
  6. Answer: (D).

Trap: ticking (C) because hypochlorite is 'the weak form' of free chlorine. Weaker than HOCl is still an active disinfectant.

Where this shows up in industry

Chloride in drinking water is limited only for taste and corrosion, at 250 mg/L acceptable in IS 10500:2012, whereas disinfection is checked by the free chlorine residual of HOCl plus OCl-, at least 0.2 mg/L at the consumer end.

GATE 2024 · CE1 · Q.61NAT · 2 marksWater supply and treatment

25 MLD plant, natural alkalinity 4 mg/L, alum needs 450 kg/day of calcium bicarbonate: quick lime per day

A water treatment plant treats 25 MLD water with a natural alkalinity of 4.0 mg/L (as CaCO3). It is estimated that, during coagulation of this water, 450 kg/day of calcium bicarbonate (Ca(HCO3)2) is required based on the alum dosage.

Consider the atomic weights as: Ca-40, H-1, C-12, O-16.

The quantity of pure quick lime, CaO (in kg) required for this process per day is___________ (rounded off to 2 decimal places).

Answer: Official key: 99 to 100 OR 154 to 156

  1. Molar mass of Ca(HCO3)2 . One mole supplies the same alkalinity as one mole of CaCO3 (100 g).
  2. Alkalinity the alum needs, as CaCO3: kg/day.
  3. Natural alkalinity already present: kg/day as CaCO3 (1 MLD at 1 mg/L is 1 kg/day).
  4. Shortfall: kg/day as CaCO3. One mole of CaO (56 g) gives one mole of Ca(OH)2 with the alkalinity of 100 g CaCO3, so CaO kg/day: 99.56 kg (key 99 to 100).
  5. The key also accepts 154 to 156: ignoring the natural alkalinity, kg.

Trap: reading 4 mg/L as calcium bicarbonate instead of CaCO3 gives kg, inside neither range; always convert to CaCO3 before subtracting.

Where this shows up in industry

Alum hydrolysis consumes alkalinity, so plants treating soft, low-alkalinity raw water dose lime ahead of or with alum to keep the pH in the coagulation range; the doses of both are set from jar tests rather than from theory alone.

GATE 2024 · CE2 · Q.42MCQ · 2 marksWater supply and treatment

Anthracite (G 1.5), silica sand 0.20 mm (G 2.6), ilmenite (G 4.2): diameters that keep three layers after backwash

A hypothetical multimedia filter, consisting of anthracite particles (specific gravity: 1.50), silica sand (specific gravity: 2.60), and ilmenite sand (specific gravity: 4.20), is to be designed for treating water/wastewater. After backwashing, the particles should settle forming three layers: coarse anthracite particles at the top of the bed, silica sand in the middle, and small ilmenite sand particles at the bottom of the bed.

Assume
(i) Slow discrete settling (Stoke's law is applicable)
(ii) All particles are spherical
(iii) Diameter of silica sand particles is 0.20 mm

The CORRECT option fulfilling the diameter requirements for this filter media is

  1. (A)diameter of anthracite particles is slightly less than 0.35 mm and diameter of ilmenite particles is slightly greater than 0.141 mm.
  2. (B)diameter of anthracite particles is slightly greater than 0.35 mm and diameter of ilmenite particles is slightly less than 0.141 mm.
  3. (C)diameter of anthracite particles is slightly less than 0.64 mm and diameter of ilmenite particles is slightly less than 0.10 mm.
  4. (D)diameter of anthracite particles is slightly greater than 0.64 mm and diameter of ilmenite particles is slightly less than 0.10 mm.

Answer: (A) diameter of anthracite particles is slightly less than 0.35 mm and diameter of ilmenite particles is slightly greater than 0.141 mm. Official key: A

  1. Stokes' law: , so at equal settling velocity is the same.
  2. After backwash the slowest settlers end up on top. Anthracite must settle slower than the sand: , so mm. Anthracite slightly below 0.35 mm meets this; a larger grain would sink through the sand.
  3. Ilmenite must settle faster than the sand: , so mm. It must be slightly larger than 0.141 mm, or it would rise into the sand.
  4. Both conditions: option (A). Check at 20 degrees C: the 0.20 mm sand settles at m/s, 0.35 mm anthracite at m/s and 0.15 mm ilmenite at m/s.

Trap: forgetting that velocity goes with and scaling diameter linearly gives mm and mm, the numbers in options (C) and (D).

Where this shows up in industry

Dual media filters with anthracite over sand, and mixed media filters that add garnet or ilmenite below, give a coarse-to-fine bed in the direction of flow, so solids are stored through the depth and filter runs are longer than in a single-medium rapid sand filter.

GATE 2025 · CE1 · Q.21MCQ · 1 markWater supply and treatment

Fecal coliform falls from 10780 to 23 cfu per 100 ml through treatment: log kill

Fecal Coliform (FC) concentration in river water was measured as 10780 cfu/100 ml. The FC concentration after the conventional water treatment, but before chlorination, was measured as 23 cfu/100 ml. The 'Log Kill' (inactivation) of FC due to the conventional water treatment is closest to

  1. (A)4.00
  2. (B)2.50
  3. (C)2.67
  4. (D)3.00

Answer: (C) 2.67 Official key: C

  1. Log kill (log removal) is the base-10 logarithm of the ratio of the counts before and after: .
  2. Ratio: , so only about 1 organism in 469 survives coagulation, settling and filtration.
  3. , closest to 2.67, option (C). In percent that is % removal.

Trap: rounding both counts to powers of ten first ( and ) gives , option (D); and using the natural log gives . Log kill always uses base 10 on the exact counts.

Where this shows up in industry

Treatment performance is credited in logs: the US EPA Surface Water Treatment Rule asks for 3-log Giardia and 4-log virus removal or inactivation, and IS 10500:2012 requires that E. coli is not detectable in any 100 ml sample of treated drinking water.

GATE 2025 · CE1 · Q.31MSQ · 1 markWater supply and treatment

Sedimentation tank at SOR 45 m3/m2/d: smallest inorganic (G 2.65) and organic (G 1.20) particles fully removed

The Surface Overflow Rate (SOR) in a rectangular sedimentation tank is 45 m3/m2/d. Minimum diameters of spherical inorganic and organic particles expected to be completely removed in this tank are calculated. Assume that Stoke's law is applicable. Which of the following options is/are correct:

Specific gravity of inorganic particles = 2.65
Specific gravity of organic particles = 1.20
Acceleration due to gravity (g) = 9.81 m/s2
Kinematic viscosity () = m2/s

  1. (A)Minimum diameter of inorganic particles is 24 µm
  2. (B)Minimum diameter of organic particles is 69 µm
  3. (C)Minimum diameter of inorganic particles is 15 µm
  4. (D)Minimum diameter of organic particles is 55 µm

Answer: (A) and (B) Official key: A;B

  1. In an ideal basin every particle whose settling velocity is at least the SOR is removed completely: m/s.
  2. Stokes' law with kinematic viscosity: , so .
  3. Inorganic, : µm, about 24 µm, (A) true; (C) is false.
  4. Organic, : µm, about 69 µm, (B) true; (D) is false.
  5. Answer: (A) and (B). The lighter organic particle has to be times larger to settle as fast.

Trap: using in place of ignores buoyancy and gives µm and µm, neither of which is an option.

Where this shows up in industry

Surface overflow rate, not depth, is the main design criterion for settling tanks in the CPHEEO manuals; under the ideal-basin theory of Hazen and Camp the removal of discrete particles depends only on the plan area for a given flow.

GATE 2025 · CE1 · Q.32MSQ · 1 markWater supply and treatment

Which pollutants does aeration remove: iron, cadmium, manganese or zinc?

Aeration is employed as a treatment option for the removal of several pollutants from contaminated water.

Identify the pollutant(s), where aeration is employed as a part of their removal:

  1. (A)Iron
  2. (B)Cadmium
  3. (C)Manganese
  4. (D)Zinc

Answer: (A) and (C) Official key: A;C

  1. Aeration adds oxygen and strips gases such as , and volatile organics. Its chemical job is oxidation.
  2. Groundwater often carries soluble ferrous iron and manganous manganese. Oxygen converts them to insoluble forms: , and to . The precipitates are then settled and filtered out. So (A) iron and (C) manganese are removed with aeration as one step. Manganese oxidises much more slowly, so plants often raise the pH or add a stronger oxidant as well.
  3. Cadmium and zinc have no higher insoluble oxidation state reachable by air; they are removed by chemical precipitation at high pH, coagulation, ion exchange or membranes. (B) and (D) are false.
  4. Answer: (A) and (C).

Trap: ticking zinc or cadmium because they are 'metals like iron'; aeration works only on metals whose oxidised form is insoluble, which is the case for Fe and Mn.

Where this shows up in industry

Iron removal plants with cascade or tray aerators followed by settling and rapid sand filters are common on borewell supplies in eastern and north-eastern India, where groundwater iron often exceeds the IS 10500:2012 acceptable limit of 1.0 mg/l.

GATE 2025 · CE2 · Q.34NAT · 1 markWater supply and treatment

Free residual chlorine 2 mg/l as Cl2 at pH 8.5, pK 7.5: HOCl concentration in micromoles per litre

Free residual chlorine concentration in water was measured to be 2 mg/l (as Cl2). The pH of water is 8.5. By using the chemical equation given below, the HOCl concentration (in µmoles/l) in water is ________ (round off to one decimal place).

Atomic weight: Cl(35.5)

Answer: Official key: 2.50 to 2.60

  1. Free chlorine = HOCl + OCl-. Expressed as (molar mass 71), and since gives one HOCl per : total µmol/l.
  2. From : .
  3. Fraction as HOCl: .
  4. µmol/l, so µmol/l (key 2.50 to 2.60).

Trap: dividing by 35.5 instead of 71 gives µmol/l, and forgetting the dissociation altogether gives µmol/l; at pH 8.5 most of the chlorine is the weaker .

Where this shows up in industry

HOCl is a far stronger disinfectant than OCl-, which is why chlorination works best below about pH 7.5; IS 10500:2012 asks for at least 0.2 mg/l of free residual chlorine in treated drinking water.

GATE 2026 · CE1 · Q.21MCQ · 1 markWater supply and treatment

Rapid sand filter 0.8 m deep, porosity 40 % in service and 70 % in backwash: expanded depth

A rapid sand filter bed of depth 0.8 m has 40 % porosity during service cycle. It is recommended that during backwash operation, the expanded filter bed should have 70 % porosity. The uniform expanded depth (in m) of the filter bed during backwash is

  1. (A)1.0
  2. (B)1.2
  3. (C)1.4
  4. (D)1.6

Answer: (D) 1.6 Official key: D

  1. Backwash lifts and separates the grains but does not add or remove sand, so the volume of solids per unit plan area stays the same.
  2. Solids volume per m2: m.
  3. Expanded bed: , so m.
  4. Answer (D) 1.6 m, a doubling of the bed depth.

Trap: scaling the depth by the porosity ratio, m, gives (C); it is the solids fraction , not the voids, that must be conserved.

Where this shows up in industry

Plant operators set the backwash rate so the sand fluidises and expands enough to release trapped floc without washing media into the troughs; the height of the wash-water troughs above the sand is fixed from this expanded depth.

GATE 2026 · CE1 · Q.22MCQ · 1 markWater supply and treatment

Which law governs the settling velocity of inorganic particles in a sedimentation tank?

The settling velocity of inorganic particles in the sedimentation tank of a water treatment plant is governed by

  1. (A)Darcy’s law
  2. (B)Stokes’ law
  3. (C)Dupuit’s law
  4. (D)Bernoulli’s law

Answer: (B) Stokes’ law Official key: B

  1. A discrete particle (sand, silt, grit) settling in still water accelerates until its submerged weight equals the fluid drag; that terminal velocity is its settling velocity.
  2. For fine particles the Reynolds number is below about 1 and the drag is viscous, which gives Stokes' law: .
  3. So settling velocity grows with the square of particle size and falls as water temperature drops (higher viscosity).
  4. Darcy's law describes flow through porous media (filter beds, aquifers), Dupuit's equation gives well discharge, and Bernoulli's equation is energy along a streamline. Answer (B).

Trap: (A) Darcy's law also appears in water treatment, for the head loss through a clean filter bed, but it says nothing about a particle falling through water.

Where this shows up in industry

Grit chambers and plain sedimentation tanks are sized from the settling velocity of the smallest particle to be removed: the surface overflow rate of the tank is set equal to that Stokes velocity.

GATE 2026 · CE1 · Q.65NAT · 2 marksWater supply and treatment

Rectangular sedimentation tank for 12 MLD, depth 4 m, detention 6 h, flow velocity 0.003 m/s: width

The maximum demand at a water purification plant has been estimated as 12 million litres per day. For the raw supplies, a rectangular sedimentation tank is to be designed with mechanical sludge removal arrangement. Consider depth of the tank as 4 m, detention period as 6 hours, and velocity of flow as 0.003 m/s.

The width (in m) of the detention tank is ________ (rounded off to two decimal places).

Answer: Official key: 11.00 to 12.00

  1. Flow: l/day m3/day m3/h.
  2. Tank volume = flow x detention time m3.
  3. Length = flow-through velocity x detention time m.
  4. Cross-section m2 (the same as ), and with a depth of 4 m the width is m, so 11.57 m (key 11.00 to 12.00).

Trap: ignoring the given velocity and assuming a length of four times the width from the plan area m2 gives m; forgetting to divide the cross-section by the depth gives m. Both are outside the key.

Where this shows up in industry

Plain sedimentation tanks ahead of filters are checked for detention time, horizontal flow-through velocity and surface loading together; the velocity check keeps settled sludge from being scoured and carried on to the filters.

GATE 2026 · CE2 · Q.63NAT · 2 marksWater supply and treatment

Water analysis with HCO3 1.0 mM and CO3 0.01 mM, pKa of HOCl 7.5: percentage of HOCl in free chlorine

The analysis of major cations and anions in a water sample collected from a city’s water supply is given below. Ions present in minor concentrations are not given.

AnionsCl-SO42-HCO3-CO32-
Concentration (mM)1.50.51.00.01
CationsNa+Ca2+Mg2+K+
Concentration (mM)20.50.250.02

,
,
,
,
,

(in %) present in the total free chlorine in the water is _____ (rounded off to the nearest integer).

Answer: % Official key: 13 to 15

  1. The ion list is balanced (anions meq/l, cations meq/l), so it can be trusted. The strong-acid anions tell nothing about pH; the carbonate pair does.
  2. .
  3. For HOCl: .
  4. HOCl fraction %, so 14 % (key 13 to 15).

Trap: assuming neutral water (pH 7) gives 76 %, and reporting the OCl- share gives 86 %; using the H2CO3/HCO3 pK 6.3 as the pH gives 94 %. All are outside the key.

Where this shows up in industry

Water utilities that chlorinate watch the pH closely: above about pH 8 most free chlorine is hypochlorite ion, a much weaker disinfectant than HOCl, so the same residual needs a longer contact time.

From GATE prep to a water supply and environmental engineering career

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.