GATE Civil: Foundation Engineering (site investigation, stress distribution, earth pressure, slope stability, shallow foundations, piles), previous-year questions solved
Every foundation engineering question from the ten official GATE Civil papers of 2022-2026 (CE1 and CE2 each year): 43 questions (26 NAT, 14 MCQ, 3 MSQ) on site investigation and in-situ tests, Boussinesq stress distribution, Rankine and Coulomb earth pressure, slope stability, bearing capacity and settlement of footings, and pile capacity and group efficiency, each solved step by step and checked by a script against the official key. The GATE 2027 syllabus adds sheet piles and ground improvement and drops the dynamic pile formulae.
Questions from the ten official GATE CE papers, sessions CE1 and CE2 of GATE 2022 (IIT Kharagpur), 2023 (IIT Kanpur), 2024 (IISc Bengaluru), 2025 (IIT Roorkee) and 2026 (IIT Guwahati); solutions by Skill-Lync. · Updated 17 Nov 2026 · 17 of 43 questions on this page
Static cone penetration test: sleeve friction from tip resistance 1000 kPa and friction ratio 1 %
At a site, Static Cone Penetration Test was carried out. The measured point (tip) resistance was 1000 kPa at a certain depth. The friction ratio () was estimated as 1 % at the same depth.
The value of sleeve (side) friction (in kPa) at that depth was ___________________ . (in integer)
Answer: Official key: 10 to 10
- In a static (Dutch) cone test the cone is pushed at a steady rate; the tip records the point resistance and the friction sleeve just behind it records the local side friction .
- The friction ratio is the sleeve friction as a percentage of the tip resistance at the same depth: .
- .
- Answer: . Read together with , the friction ratio indicates soil type: sands usually give low ratios and clays higher ones.
Trap: forgetting that is a percentage and multiplying by 1 gives 1000 kPa, a sleeve friction equal to the tip resistance, which never happens in a real sounding.
CPT soundings to IS 4968 (Part 3) are logged as and profiles; the friction ratio is used to infer the soil type between boreholes, and feeds directly into CPT-based shaft friction estimates for driven piles.
Inside diameter of a sampler cutting edge for a 50 mm tube and an inside clearance ratio of 1 %
The inside diameter of a sampler tube is 50 mm. The inside diameter of the cutting edge is kept such that the Inside Clearance Ratio (ICR) is 1.0 % to minimize the friction on the sample as the sampler tube enters into the soil.
The inside diameter (in mm) of the cutting edge is _________________. (round off to two decimal places)
Answer: Official key: 49.49 to 49.52
- The cutting edge is swaged slightly inwards so that the sample, once cut, is a little smaller than the tube and slides up without wall friction.
- Inside clearance ratio: , where is the inside diameter of the tube and that of the cutting edge.
- , so mm.
- Answer: (key 49.49 to 49.52). Dividing by instead, mm, rounds to the same value, so the key accepts both; the standard definition divides by .
Trap: making the cutting edge larger than the tube, mm, which is the outside-clearance idea applied to the wrong face. A larger cutting edge would let the sample rub along the full tube wall.
Undisturbed tube samples of soft clay for consolidation and triaxial tests are taken with thin-walled samplers to IS 2132, where the inside clearance (textbooks quote about 1 to 3 %) and the area ratio are what keep sample disturbance low.
SPT N of 28 recorded with a 50% efficient manual hammer: value with a 70% efficient automatic hammer
A standard penetration test (SPT) was carried out at a location by using a manually operated hammer dropping system with 50% efficiency. The recorded SPT value at a particular depth is 28. If an automatic hammer dropping system with 70% efficiency is used at the same location, the recorded SPT value will be ________.
- (A)28
- (B)20
- (C)40
- (D)25
Answer: (B) 20 Official key: B
- The blow count measures the energy needed to drive the sampler 300 mm. Energy delivered per blow is proportional to hammer efficiency, so for the same soil is constant.
- The more efficient hammer drives the sampler further per blow, so fewer blows are needed. The same rule gives the standard energy-corrected value .
- Answer: (B) 20
Trap: (C) 40 is , and multiplying by gives 39.2; both raise when more energy per blow must lower it. (A) treats as a soil constant independent of the equipment.
Indian site investigation reports still record SPT N to IS 2131, often with manually operated hammers; before using N in bearing capacity, settlement or the IS 1893 liquefaction check, engineers normalise it to 60% energy (), and must know which hammer the driller used.
Match Menard, Marchetti, Casagrande, Proctor with pressuremeter, dilatometer, liquid limit, compaction tests
The name of a person in Column 1 is to be matched with the test mentioned in Column 2.
| Column 1 | Column 2 |
|---|---|
| (I) Menard | (P) Dilatometer test |
| (II) Marchetti | (Q) Pressuremeter test |
| (III) Casagrande | (R) Compaction test |
| (IV) Proctor | (S) Liquid limit test |
Option giving the CORRECT match between Column 1 and Column 2 is:
- (A)(I) – (Q); (II) – (P); (III) – (S); (IV) – (R)
- (B)(I) – (R); (II) – (S); (III) – (Q); (IV) – (P)
- (C)(I) – (P); (II) – (Q); (III) – (S); (IV) – (R)
- (D)(I) – (R); (II) – (S); (III) – (P); (IV) – (Q)
Answer: (A) (I) – (Q); (II) – (P); (III) – (S); (IV) – (R) Official key: A
- Louis Ménard developed the pressuremeter (PMT): a cylindrical probe expanded against the borehole wall gives the pressuremeter modulus and limit pressure. So (I) – (Q).
- Silvano Marchetti developed the flat dilatometer (DMT): a steel blade pushed into the ground with a membrane inflated by about 1 mm, giving the material, horizontal-stress and dilatometer-modulus indices. So (II) – (P).
- Arthur Casagrande standardised the percussion cup device for the liquid limit (25 blows to close the groove), the test of IS 2720 (Part 5). So (III) – (S).
- R. R. Proctor introduced the standard compaction test (water content against dry density). So (IV) – (R).
- Answer: (A) (I) – (Q); (II) – (P); (III) – (S); (IV) – (R) (official key: A).
Trap: (C) keeps both laboratory tests right but swaps the two in-situ devices. Remember Ménard with pressure (a pressuremeter expands a cylinder in a borehole) and Marchetti with a blade (the dilatometer is pushed, not placed in a borehole).
Pressuremeter and flat dilatometer tests are specified in Indian site investigation contracts for metro, high-rise and bridge foundations where SPT values alone are unreliable, to get deformation moduli for settlement and laterally loaded pile analysis; the liquid limit and Proctor tests are routine on every borrow-area and subgrade sample.
Inner diameter of a 50.8 mm thin-walled sampling tube for an area ratio of 10 % (undisturbed clay sample)
To obtain undisturbed clay soil sample, an Area Ratio of 10 % needs to be achieved for a thin walled sampling tube. If the outer diameter of the tube is 50.8 mm, the inner diameter (in mm) is __________________ (rounded off to one decimal place).
Answer: Official key: 48.2 to 48.6
- Area ratio (Hvorslev, as used in IS 2132): , the volume of soil displaced by the tube wall as a fraction of the sample area.
- , so and .
- . Check: .
- Answer: (key range 48.2 to 48.6).
Trap: dropping the squares and writing gives , outside the key. The area ratio compares areas, so diameters enter squared. (Putting in the denominator gives 48.2 mm, which the wide key also accepts, but the standard definition divides by .) Thin-walled tubes are made with an area ratio of about 10 % or less so that sample disturbance stays small.
When a soft clay layer is met in a borehole, the driller switches from the split spoon to thin-walled Shelby tubes to IS 2132; the tube's area ratio, inside clearance and cutting-edge taper are checked on site before the undisturbed samples for consolidation and triaxial tests are accepted.
Boussinesq point load of 3000 kN: ratio of vertical stress increase at 1 m and 2 m depth below the load
A concentrated vertical load of 3000 kN is applied on a horizontal ground surface. Points P and Q are at depths 1 m and 2 m below the ground, respectively, along the line of application of the load. Considering the ground to be a linearly elastic, isotropic, semi-infinite medium, the ratio of the increase in vertical stress at P to the increase in vertical stress at Q is ________. (in integer)
Answer: Official key: 4 to 4
- Boussinesq: .
- Both points lie on the load axis, so and .
- At P ( m): kPa. At Q ( m): kPa.
- Ratio . Answer: (key 4 to 4).
Trap: assuming the stress falls linearly with depth gives a ratio of 2. On the axis of a point load the stress falls with the square of depth, so doubling the depth quarters it.
The axial Boussinesq stress is used to check heavy concentrated loads such as crane outrigger pads or transformer plinths placed over buried pipelines and culverts, and is the basis of the Newmark chart used for irregular footing plans.
Maximum depth of the 10 % pressure bulb by Boussinesq below a 2 m square footing carrying 1000 kN
A concentrically loaded isolated square footing of size 2 m × 2 m carries a concentrated vertical load of 1000 kN. Considering Boussinesq’s theory of stress distribution, the maximum depth (in m) of the pressure bulb corresponding to 10 % of the vertical load intensity will be ___________. (round off to two decimal places)
Answer: Official key: 4.35 to 4.39
- Load intensity on the footing: kPa, so the 10 % bulb is the isobar kPa.
- The bulb is deepest on the load axis (). Treating the 1000 kN as a concentrated load, as the question says: .
- , so and m.
- Answer: (key 4.35 to 4.39).
Trap: integrating 250 kPa over the 2 m square gives the 0.1q isobar at 4.17 m, outside the key, so the examiners meant the point-load formula. Taking 10 % of the total load (100 kPa) instead of the intensity gives 2.19 m.
The 10 % pressure bulb is the usual measure of the significant depth below a footing: boreholes for an isolated column footing are taken at least that deep, and settlement of any compressible layer inside it has to be calculated.
Boussinesq point load: locus of the depth at which the vertical stress is maximum for a given radial distance
Consider that a force P is acting on the surface of a half-space (Boussinesq’s problem). The expression for the vertical stress () at any point , within the half-space is given as,
where, r is the radial distance, and is the depth with downward direction taken as positive. At any given r, there is a variation of along , and at a specific , the value of will be maximum. What is the locus of the maximum ?
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- At fixed , maximise . Taking logs, .
- , so , i.e. .
- Locus: , the straight lines through the load point, at from the vertical. A numerical search at several gives .
- Near the surface (the term) and at great depth it decays as , so this stationary point is a maximum.
- Answer: (A)
Trap: (C) comes from setting , differentiating the bracket with respect to instead of . Only the -derivative is asked for, at fixed .
When a heavy column, tower leg or crane outrigger sits near a buried pipeline, culvert or tunnel, engineers use the Boussinesq solution to find the depth at which the stress increase on that structure peaks for a given horizontal offset, and check that depth against its crown level.
Minimum exploration depth below a 2000 kN column: Boussinesq stress down to 10 % of effective overburden
A building is proposed in an area having thick deposit of silty clay. The water table is at the ground surface. The saturated unit weight of soil is 18 kN/m3 and unit weight of water is 10 kN/m3. The maximum vertical load (P) on a column of the proposed building is 2000 kN.
Consider for computation of the minimum depth of soil exploration.
is the effective vertical overburden stress. is the increase in the vertical stress at depth z below load P as per the Boussinesq’s stress theory.
Based on above, the minimum depth (in m) of soil exploration required for the foundation design is ________ (rounded off to two decimal places).
Answer: Official key: 10.00 to 11.20
- Boussinesq point load, directly below the load: .
- Water table at the surface: , so .
- Exploration ends where : , so .
- . Check: and . Answer: (key range 10.00 to 11.20).
Trap: using the saturated unit weight for the overburden () gives , outside the key. The criterion is on effective stress, and with the water table at ground level that is .
Geotechnical consultants use this criterion, stopping where the stress added by the foundation falls to about 10 % of the effective overburden, to fix borehole depths when scoping an IS 1892 investigation for buildings on thick soft deposits, since every stratum the structure stresses significantly must be explored.
Condition on effective vertical and horizontal stress for failure under Rankine's passive earth pressure
Let and denote the effective vertical stress and effective horizontal stress, respectively. Which one of the following conditions must be satisfied for a soil element to reach the failure state under Rankine’s passive earth pressure condition?
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- In the passive state the wall is pushed into the soil, so the soil is compressed laterally while the vertical stress stays at the overburden value .
- The horizontal stress rises from the at-rest value until the Mohr circle touches the failure envelope. At that point it is the major principal stress: with .
- Example: gives , so with kPa the passive kPa, three times .
- So at passive failure . Answer: (A).
Trap: (B) is the active state, where the wall moves away and drops to kPa. (C) is a hydrostatic stress state with zero shear, which can never be a failure state for a frictional soil.
Passive resistance in front of the embedded toe of cantilever sheet piles and diaphragm walls for basements and metro station boxes, and in front of the shear key of a retaining wall, is computed exactly this way, usually with a reduction factor because full passive pressure needs large movement.
Rankine theory: is the failure plane at 45 + phi/2 to the minor principal stress in active, passive or both
As per Rankine’s theory of earth pressure, the inclination of failure planes is with respect to the direction of the minor principal stress.
The above statement is correct for which one of the following options?
- (A)Only the active state and not the passive state
- (B)Only the passive state and not the active state
- (C)Both active as well as passive states
- (D)Neither active nor passive state
Answer: (C) Both active as well as passive states Official key: C
- From the Mohr circle at failure, the failure plane makes with the major principal plane. The major principal plane is perpendicular to , so it contains the direction of : the failure plane is at to the direction, in any state.
- Active: is vertical and horizontal, so the planes are at to the horizontal (the direction).
- Passive: is horizontal and vertical; the planes are at to the horizontal, i.e. to the vertical, which is again the direction.
- Check for : searching all planes for the Mohr-Coulomb condition gives 60.0 degrees from horizontal (active) and 30.0 degrees (passive), i.e. 60.0 and 60.0 degrees to the direction. Answer: (C).
Trap: (A) comes from remembering only “ to the horizontal in active, in passive” and forgetting that the reference direction, , switches from horizontal to vertical.
The active wedge angle sets how far behind a wall the slip surface reaches, so ground anchors and soil nails for deep excavations are given a free length that carries the bond zone beyond this plane before the fixed length begins.
Rankine active earth pressure at the base of a smooth wall with two soil layers and a 20 kPa surcharge
A smooth vertical retaining wall supporting layered soils is shown in figure. According to Rankine’s earth pressure theory, the lateral active earth pressure acting at the base of the wall is ________ kPa (round off to one decimal place).
Answer: Official key: 34.0 to 37.0
- At the base the soil is layer 2, so use its parameters: , .
- Vertical stress at the base: kPa (no water table given, bulk unit weights throughout).
- Rankine with cohesion: kPa.
- Hand check: , the same value.
- kPa
Trap: using layer 1's for the whole height gives 46.1 kPa; forgetting the cohesion term gives 60.9 kPa; leaving out the surcharge gives 27.3 kPa. The pressure is discontinuous at the interface, and each point takes the and of the soil it is in.
Basement walls, bridge abutments and cantilever retaining walls in India often retain a granular fill over a natural clayey layer; the lateral pressure diagram is built layer by layer this way before checking sliding, overturning and the wall's bending reinforcement.
Maximum depth of a vertical trench in clay under 30 kPa surcharge supported by a 12 kN/m3 fluid
A vertical trench is excavated in a clayey soil deposit having a surcharge load of 30 kPa. A fluid of unit weight 12 kN/m3 is poured in the trench to prevent collapse as the excavation proceeds. Assume that the fluid is not seeping through the soil deposit. If the undrained cohesion of the clay deposit is 20 kPa and saturated unit weight is 18 kN/m3, what is the maximum depth of unsupported excavation (in m, rounded off to two decimal places)? ________
Answer: Official key: 3.30 to 3.35
- Undrained clay, , so and Rankine gives kPa. The fluid presses back with .
- As for the classic unsupported cut ( m with no fluid or surcharge), the trench stands while the total active thrust does not exceed the fluid thrust; the negative (tension) part near the top counts.
- gives .
- m. Check: both thrusts equal 66.67 kN/m.
- m
Trap: equating the pressures only at the base, , gives 1.67 m. That is the depth where the net pressure changes sign, not where the whole wall of the trench loses equilibrium.
Bentonite or polymer slurry supports the trench panels of diaphragm walls for metro station boxes and deep basements; contractors check that the slurry head and density keep the fluid thrust above the active thrust of the clay plus any surcharge from adjacent buildings or crane loads.
Force polygon of the passive failure wedge behind a vertical wall with an inclined c-phi backfill
The figure shows a vertical retaining wall with backfill consisting of cohesive-frictional soil and a failure plane developed due to passive earth pressure. The forces acting on the failure wedge are: P as the reaction force between the wall and the soil, R as the reaction force on the failure plane, C as the cohesive force along the failure plane and W as the weight of the failure wedge. Assuming that there is no adhesion between the wall and the wedge, identify the most appropriate force polygon for the wedge.
- (A)
- (B)
- (C)
- (D)
Answer: (C) P inclined downward, C acting down the failure plane Official key: C
- Passive case: the wall pushes the wedge into the backfill, so the wedge moves up along the failure plane and up relative to the wall. Every resisting force on the wedge acts against that motion.
- W acts vertically down. C (cohesion on the failure plane) acts down the plane, towards the wall.
- P: no adhesion means no cohesive shear on the wall, but wall friction remains; it acts downward on the rising wedge, so P is inclined below the normal.
- R is inclined at to the normal of the failure plane, rotated to oppose the upward slip, so it points up and towards the wall at a flat angle.
- Head to tail: P (right and down), W (down), C (down the plane), R (closing, up to the left). Solving a trial wedge ( m, , , kPa) gives kN/m and kN/m, both positive with these directions. Answer: (C)
Trap: (D) has the right P but C pointing up the plane, which is the active case. (A) and (B) tilt P upward, also the active-case direction of wall friction.
Trial-wedge passive resistance is computed this way for the toe of embedded sheet pile and cantilever walls and for shear keys under retaining walls; putting wall friction or cohesion in the active direction makes the passive resistance unconservatively large.
Failure-plane inclinations to the major principal plane in Rankine active and passive states, phi = 30
A vertical smooth rigid retaining wall is supporting horizontal ground with dry cohesionless backfill having a friction angle of . The inclinations of failure planes with respect to the major principal plane for Rankine’s active and passive earth pressure conditions, respectively, are
- (A) and
- (B) and
- (C) and
- (D) and
Answer: (B) and Official key: B
- From the Mohr circle at failure, a failure plane always makes with the major principal plane, whatever the direction of .
- Active state: the wall moves away, drops, so and the major principal plane is horizontal. Failure planes: to it (that is, to the horizontal).
- Passive state: the wall is pushed into the soil, rises above , so and the major principal plane is vertical. Failure planes: to the vertical, which is to the horizontal.
- Measured from the major principal plane, both are . Answer: (B) and .
Trap: (D) and . That is the pair measured from the horizontal; the question measures from the major principal plane, which turns vertical in the passive state.
The active wedge angle tells the designer of a cantilever or gravity retaining wall how far behind the stem the backfill is mobilised, which fixes the width of the free-draining granular zone and whether a nearby road or footing surcharge falls inside the wedge; IS 14458 (Part 1) for retaining walls in hill areas uses the same Rankine and Coulomb framework.
Direction of wall friction when a rough wall moves into the backfill, and how theories treat surcharge
Consider the statements P and Q related to the analysis/design of retaining walls.
P: When a rough retaining wall moves toward the backfill, the wall friction force/resistance mobilizes in upward direction along the wall.
Q: Most of the earth pressure theories calculate the earth pressure due to surcharge by neglecting the actual distribution of stresses due to surcharge.
Which one of the following options is CORRECT?
- (A)Both P and Q are TRUE
- (B)P is TRUE and Q is FALSE
- (C)Both P and Q are FALSE
- (D)P is FALSE and Q is TRUE
Answer: (D) P is FALSE and Q is TRUE Official key: D
- P: a wall moving toward the backfill is the passive case. The wall pushes the soil wedge, which is squeezed out and slides upward along the wall face.
- Friction always opposes relative movement, so the resistance the rough wall mobilises against the rising wedge acts downward along the wall, and the passive thrust is inclined at below the normal. Upward friction belongs to the active case, where the wedge slides down. P is FALSE.
- Q: Rankine and Coulomb treat a uniform surcharge as an extra vertical stress at every depth (adding to the lateral pressure) or as an equivalent height of fill . Neither uses the true spread of stress from the surcharge with depth (Boussinesq type), which is only brought in separately for line and strip loads. Q is TRUE.
- Answer: (D) P is FALSE and Q is TRUE.
Trap: (A). Carrying the active-case picture of upward wall friction over to a wall that is pushed into the soil; in the passive case the direction reverses.
Bridge abutments and return walls in India are designed with Coulomb coefficients that include wall friction, and IRC 6 converts live-load surcharge into an equivalent 1.2 m of earth fill, the same simplified surcharge treatment described in statement Q.
Rankine theory: FALSE failure-plane inclinations to the major principal plane in active and passive states
As per the Rankine’s earth pressure theory, which of the following statements is/are FALSE?
- (A)For the active earth pressure, the inclination of failure plane is with respect to the major principal plane.
- (B)For the active earth pressure, the inclination of failure plane is with respect to the major principal plane.
- (C)For the passive earth pressure, the inclination of failure plane is with respect to the major principal plane.
- (D)For the passive earth pressure, the inclination of failure plane is with respect to the major principal plane.
Answer: (B) and (D) Official key: B;D
- From the Mohr circle at failure, the failure plane always makes with the plane on which the major principal stress acts, whatever the state.
- Active state: the wall moves away, the horizontal stress drops, so and the major principal plane is horizontal. Failure planes are at to the horizontal. (A) is true, so (B) is false.
- Passive state: the wall is pushed into the soil, rises above , so and the major principal plane is vertical. Failure planes are at to the vertical, which is to the horizontal. (C) is true, so (D) is false.
- Answer: (B) and (D) (official key: B;D).
Trap: learning the passive wedge as to the horizontal and forgetting that the horizontal is the minor principal plane in the passive case. That reasoning marks (C) false and (D) true, giving B;C, which does not match the key.
The wedge angle sets how far behind a cantilever or counterfort retaining wall the active zone extends, which decides where drains, surcharge loads and the anchor blocks of tied sheet-pile walls in Indian ports and basements must be placed (anchors go outside the active wedge).