GATE Mechanical: Heat Transfer, previous-year questions solved, part 2

Part 2 of 2 of the Heat Transfer hub: 19 more official GATE ME questions on convection: free, forced and internal flow, radiation and heat exchangers, each solved step by step and checked against the official answer key. Part 1 covers steady conduction and heat generation and fins and transient (lumped) conduction.

Questions from official GATE ME papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 16 Nov 2026 · 19 of 29 questions on this page

GATE 2022 · ME Set-1 · Q.25MCQ · 1 markConvection: free, forced and internal flow

In the natural convection momentum equation, what does the term gβ(T − T∞) represent?

In the following two-dimensional momentum equation for natural convection over a surface immersed in a quiescent fluid at temperature ( is the gravitational acceleration, is the volumetric thermal expansion coefficient, is the kinematic viscosity, and are the velocities in and directions, respectively, and is the temperature)the term represents
  1. (A)Ratio of inertial force to viscous force.
  2. (B)Ratio of buoyancy force to viscous force.
  3. (C)Viscous force per unit mass.
  4. (D)Buoyancy force per unit mass.

Answer: (D) Official key: D

Every term in this equation has units of acceleration (m/s2), that is, force per unit mass. The left side is inertia, is the viscous force, and comes from the density difference acting under gravity: the buoyancy force per unit mass.

(A) and (B) are ratios, which are dimensionless groups (Reynolds and Grashof numbers), not terms of a dimensional equation.

Where this shows up in industry

This Boussinesq buoyancy term is what drives natural convection in electronics enclosures, transformer oil, room air and solar water heaters. CFD codes switch it on as a 'gravity + Boussinesq' setting; forget it and a fan-less enclosure shows no airflow at all.

GATE 2026 · ME · Q.27MCQ · 1 markConvection: free, forced and internal flow

Fluid rises near one vertical plate and falls near the other. How do T₁, T₂ and T₃ compare?

A quiescent fluid at temperature is confined between two vertical parallel plates. While plate 1 is kept at temperature and plate 2 is maintained at temperature , a velocity profile between the plates, as shown in the figure below, is generated due to heat transfer. Which one of the following options shows the correct relations among , , and ?
Fluid between two vertical plates: the velocity profile is upward near plate 1 and downward near plate 2, with gravity acting downPlate 1 at T₁Plate 2 at T₂gravityquiescent fluid at T₃
  1. (A) and
  2. (B) and
  3. (C) and
  4. (D) and

Answer: (A) Official key: A

The only thing moving the fluid is buoyancy. Near plate 1 the fluid moves up, so it is lighter than the bulk: it has been heated, and . Near plate 2 it moves down, so it is heavier: it has been cooled, and .

Together: , option (A).

Where this shows up in industry

This loop of rising and falling fluid is how double-glazed windows lose heat across the gas gap, and how passive cooling works in electronics racks and solar chimneys. Window makers size the gap to keep this circulation weak.

GATE 2025 · ME · Q.15MCQ · 1 markConvection: free, forced and internal flow

A ball of ice at −7 °C sits in still air at 30 °C. Which way does the air flow?

Let a spherical block of ice at –7 °C be exposed to atmospheric air at 30 °C with the gravitational direction as shown in the figure below. What will be the overall direction of air flow in this situation?
Spherical ice block at −7 °C surrounded by air at 30 °C, with gravity acting downward; arrows mark upward, downward and sideward directions−7 °CIce blockAir 30 °CAir 30 °CGravityUpwardDownwardSideward
  1. (A)Upward
  2. (B)Downward
  3. (C)NO motion
  4. (D)Sideward

Answer: (B) Official key: B

Air touching the ice is cooled from 30 °C towards −7 °C. Cooler air is denser, so it is heavier than the surrounding air and sinks. Warm air moves in from the sides and top to replace it. The overall flow is downward, a cold plume falling from the bottom of the sphere.

It is the mirror image of the rising plume above a hot body.

Where this shows up in industry

You can feel this falling cold air below an open freezer or an AC indoor unit. Cold-room and display-fridge designers place evaporators high for this reason, so the cold air falls through the products.

GATE 2022 · ME Set-2 · Q.25MCQ · 1 markConvection: free, forced and internal flow

Which non-dimensional term is an estimate of the Nusselt number?

Which of the following non-dimensional terms is an estimate of Nusselt number?
  1. (A)Ratio of internal thermal resistance of a solid to the boundary layer thermal resistance
  2. (B)Ratio of the rate at which internal energy is advected to the rate of conduction heat transfer
  3. (C)Non-dimensional temperature gradient
  4. (D)Non-dimensional velocity gradient multiplied by Prandtl number

Answer: (C) Official key: C

At the wall, all the heat passes by conduction through the still fluid layer: . Making and dimensionless (, ) gives : the non-dimensional temperature gradient at the surface.

(A) is the Biot number (it uses the solid's conductivity), (B) is the Péclet number ().

Where this shows up in industry

CFD codes compute exactly this way: from the temperature gradient in the first cell next to the wall. That's why thermal simulations need a fine mesh at the wall; a coarse first cell gives a wrong gradient and a wrong Nusselt number.

GATE 2024 · ME · Q.18MCQ · 1 markConvection: free, forced and internal flow

The free-stream velocity over a flat plate doubles in laminar flow. By what factor does the Nusselt number change?

Consider incompressible laminar flow over a flat plate with freestream velocity of . The Nusselt number corresponding to this flow velocity is . If the freestream velocity is doubled, the Nusselt number changes to . Choose the correct option for .
  1. (A)
  2. (B)2
  3. (C)1.26
  4. (D)1

Answer: (A) Official key: A

  1. Laminar flat plate (Blasius / Pohlhausen): (the average Nu has 0.664, same exponents).
  2. and Pr doesn't change, so .
  3. .

uses the Prandtl exponent by mistake. In turbulent flow () the ratio would be about 1.74.

Where this shows up in industry

Doubling fan speed on a heat sink in laminar flow buys only about 41% more heat transfer while fan power rises roughly eightfold. That's why electronics cooling designers usually add fin area before they add airflow.

GATE 2023 · ME · Q.21MCQ · 1 markConvection: free, forced and internal flow

Fully developed laminar flow in an isothermal tube: does the Nusselt number depend on Re or Pr?

Consider incompressible laminar flow of a constant property Newtonian fluid in an isothermal circular tube. The flow is steady with fully-developed temperature and velocity profiles. The Nusselt number for this flow depends on
  1. (A)neither the Reynolds number nor the Prandtl number
  2. (B)both the Reynolds and Prandtl numbers
  3. (C)the Reynolds number but not the Prandtl number
  4. (D)the Prandtl number but not the Reynolds number

Answer: (A) Official key: A

  1. Fully developed laminar flow has the parabolic velocity profile whatever the Reynolds number. Thermally fully developed means the shape of no longer changes along the tube.
  2. Putting both into the energy equation, with scaled by , leaves with and . is the eigenvalue of this equation; Re and Pr do not appear.
  3. Solving it numerically gives , the textbook 3.66 for a constant wall temperature (4.36 for a constant heat flux). A constant: neither Re nor Pr, option (A).

Re and Pr do matter in the thermal entry region (through the Graetz number) and in turbulent flow (), which is where option (B) comes from.

Where this shows up in industry

Cold plates for electronics, battery cooling channels and compact heat exchangers often run laminar in small passages, and designers use Nu = 3.66 or 4.36 (adjusted for channel shape) directly. Since , pumping faster does not raise once the flow is fully developed; smaller channels do.

GATE 2025 · ME · Q.51NAT · 2 marksConvection: free, forced and internal flow

How long must a tube with 2000 W/m² heat flux be to heat 0.01 kg/s of water from 293 K to 353 K?

Water enters a tube of diameter, with mass flow rate of 0.01 kg s−1 as shown in the figure below. The inlet mean temperature is and the uniform heat flux at the surface of the tube is 2000 W m−2. For the exit mean temperature of , the length of the tube, is ________m (rounded off to 1 decimal place).
Use the specific heat of water as 4181 J kg−1 K−1.
Water at 0.01 kg/s enters a 60 mm tube at 293 K and leaves at 353 K; a uniform heat flux of 2000 W per square metre acts over the tube length L2000 W m⁻²Water0.01 kg s⁻¹293 K353 KD = 60 mmL

Answer: 6.7 m Official key: 6.5 to 6.8

  1. Heat picked up by the water: .
  2. With a uniform flux that heat enters through the wall area : .
  3. .

No convection coefficient is needed: with a fixed flux, the energy balance alone sets the length. would only be needed to find the wall temperature.

Where this shows up in industry

Solar water-heater tubes, electric heaters and boiler tubes are sized from this energy balance first. Then the wall temperature is checked against the limit (boiling, scaling or the material rating) using a Nusselt-number correlation, as in the next question.

GATE 2022 · ME Set-2 · Q.65NAT · 2 marksConvection: free, forced and internal flow

A 40 m pipe carries 1 kg/s under 15 kW/m² heat flux. What is the wall temperature at the exit?

Consider a hydrodynamically and thermally fully-developed, steady fluid flow of 1 kg/s in a uniformly heated pipe with diameter of 0.1 m and length of 40 m. A constant heat flux of magnitude 15000 W/m2 is imposed on the outer surface of the pipe. The bulk-mean temperature of the fluid at the entrance to the pipe is 200 °C. The Reynolds number () of the flow is 85000, and the Prandtl number () of the fluid is 5. The thermal conductivity and the specific heat of the fluid are 0.08 W·m−1·K−1 and 2600 J·kg−1·K−1, respectively. The correlation is applicable, where the Nusselt Number () is defined on the basis of the pipe diameter. The pipe surface temperature at the exit is ________ °C (round off to the nearest integer).

Answer: 321 °C Official key: 317 to 324

  1. Heat added: .
  2. Exit bulk temperature: .
  3. Dittus-Boelter: , so .
  4. Wall minus bulk: , so .

With constant heat flux and fully developed flow, the wall-to-fluid difference is the same all along the pipe, so the wall is hottest at the exit.

Where this shows up in industry

Engineers check boiler tubes, nuclear fuel channels and electric heaters for exactly this: the exit wall temperature is the highest and decides whether the fluid boils, cokes or degrades. Dittus-Boelter is the quick hand check; CFD or the Gnielinski correlation is used when ±25% isn't good enough.

GATE 2022 · ME Set-1 · Q.35NAT · 1 markRadiation

A cast-iron plate absorbs 600 W/m² of sunlight and has a low-temperature absorptivity of 0.21. How hot does it get?

A flat plate made of cast iron is exposed to a solar flux of 600 W/m2 at an ambient temperature of 25 °C. Assume that the entire solar flux is absorbed by the plate. Cast iron has a low temperature absorptivity of 0.21. Use Stefan-Boltzmann constant = W/m2-K4. Neglect all other modes of heat transfer except radiation.
Under the aforementioned conditions, the radiation equilibrium temperature of the plate is __________ °C (round off to the nearest integer).

Answer: 218 °C Official key: 210 to 225

  1. At low (infrared) wavelengths Kirchhoff's law gives emissivity = absorptivity = 0.21. That value applies to what the plate emits and to the infrared it absorbs from the 25 °C surroundings.
  2. Energy balance: .
  3. , so .

Ignoring the radiation coming back from the surroundings gives 201 °C, outside the key range.

Where this shows up in industry

This is the idea behind selective coatings on solar water heaters: absorb almost all the sunlight but emit little infrared, so the absorber runs hot. Black chrome and sputtered cermet coatings do this, with solar absorptivity above 0.9 and infrared emissivity near 0.1.

GATE 2022 · ME Set-2 · Q.35NAT · 1 markRadiation

A surface's emissivity peaks at 6000 Å. At what temperature is its total emissivity highest?

Wien's law is stated as follows: , where is 2898 µm·K and is the wavelength at which the emissive power of a black body is maximum for a given temperature . The spectral hemispherical emissivity () of a surface is shown in the figure below (). The temperature at which the total hemispherical emissivity will be highest is __________ K (round off to the nearest integer).
Spectral emissivity of a surface plotted against wavelength: a single peak at 6000 Å, falling off towards 5000 Å and 7000 Åελλ (Å)500060007000

Answer: 4830 K Official key: 4825 to 4835

  1. Total emissivity is the spectral emissivity averaged over the blackbody spectrum at . It is largest when most of the blackbody energy falls where is high, that is, when the blackbody peak sits on the emissivity peak.
  2. Emissivity peak: .
  3. .
Where this shows up in industry

The same idea guides the choice of pyrometers and infrared cameras: they are built for the wavelength band where the target emits most strongly. For the sun (about 5800 K) that peak is near 0.5 µm, which is why solar absorber coatings are tuned for the visible band.

GATE 2024 · ME · Q.50NAT · 2 marksRadiation

A 6 m hemispherical furnace dome at 1200 K radiates to a black base at 300 K. What is the heat transfer rate?

Consider a hemispherical furnace of diameter with a flat base. The dome of the furnace has an emissivity of 0.7 and the flat base is a blackbody. The base and the dome are maintained at uniform temperature of 300 K and 1200 K, respectively. Under steady state conditions, the rate of radiation heat transfer from the dome to the base is ________kW (rounded off to the nearest integer).
Use Stefan-Boltzmann constant = W/(m2 K4)

Answer: 2727 kW Official key: 2720 to 2740

  1. Areas: base ; dome ().
  2. The flat base sees only the dome: .
  3. Two-surface enclosure, base black (no surface resistance): .
  4. .
Where this shows up in industry

Furnace and kiln designers use this resistance network to size burners and to predict how fast the load (here the base) heats. Above about 800 °C radiation carries most of the heat in a furnace, so emissivity of the refractory lining matters a lot.

GATE 2025 · ME · Q.48NAT · 2 marksRadiation

In a black cylindrical furnace, how much heat does the 800 K bottom radiate to the 500 K curved wall?

Consider a cylindrical furnace of 5 m diameter and 5 m length with bottom, top and curved surfaces maintained at uniform temperatures of 800 K, 1500 K and 500 K, respectively. The view factor between the bottom and top surfaces, is 0.2. The magnitude of net radiation heat transfer rate between the bottom surface and the curved surface is _____________ kW (rounded off to 1 decimal place).
All surfaces of the furnace can be assumed as black.
The Stefan-Boltzmann constant, W m−2 K−4.

Answer: 309.1 kW Official key: 308 to 310

  1. Summation rule for the flat bottom (it can't see itself): .
  2. Bottom area .
  3. Black surfaces exchange directly: .

The top at 1500 K doesn't enter this answer: with black surfaces each pair exchanges heat independently of the others.

Where this shows up in industry

View factors and the summation rule are the core of radiation modelling in furnaces, spacecraft and building daylighting. CFD radiation models (surface-to-surface, discrete ordinates) compute thousands of these factors, and engineers check the results against a hand calculation like this one.

GATE 2023 · ME · Q.43MCQ · 2 marksRadiation

A rod inside a cubic enclosure: what is the view factor of the cube's inner surface to itself?

A cylindrical rod of length and diameter is placed inside a cubic enclosure of side length . denotes the inner surface of the cube. The view-factor is
  1. (A)0
  2. (B)1
  3. (C)
  4. (D)

Answer: (D) Official key: D

  1. The rod is convex, so all radiation leaving it lands on the cube: .
  2. Reciprocity: . The rod's area is its curved surface plus two end discs, , and . So .
  3. Summation for (it sees only the rod and itself): : option (D).

Option (C) is , one step short. Zero (A) would be right for a flat or convex surface; the inside of a box is concave and sees itself.

Where this shows up in industry

Surface-to-surface radiation models in CFD and thermal FEA compute thousands of view factors and then enforce exactly these two rules, summation and reciprocity, to clean up numerical error. A heater rod in an oven or a thermocouple in a furnace is this same rod-in-enclosure problem.

GATE 2026 · ME · Q.54NAT · 2 marksRadiation

A hot plate radiates to a room and to an insulated plate at right angles. What is the total radiation resistance?

Two rectangular surfaces both having 1 m2 area are placed perpendicular to each other with a common edge. One surface is hot, having a temperature of 1000 K and emissivity of 0.4, while the other is insulated and in radiant balance with a large surrounding room at 300 K. If the fraction of radiation leaving the hot surface which reaches the cold surface is 0.2, then the equivalent overall resistance for the radiation heat loss from the hot surface is _______ m−2 (rounded off to 2 decimal places).

Answer: 2.54 m⁻² Official key: 2.50 to 2.60

  1. Surfaces: 1 hot (), 2 insulated (reradiating: it sends back everything it receives), 3 the large room (acts black). , so . Equal areas give and .
  2. Surface resistance of 1: .
  3. From to the room there are two parallel paths: direct, ; and through surface 2, . In parallel: .
  4. Total: .

The 1000 K and 300 K temperatures are not needed for the resistance, only for the heat loss itself ().

Where this shows up in industry

Insulated refractory walls in furnaces act as reradiating surfaces: they don't absorb net heat but bounce it back towards the load. Furnace designers add them deliberately to make heating more even.

GATE 2022 · ME Set-1 · Q.65NAT · 2 marksHeat exchangers

Blood is cooled from 37 °C to 25 °C by water warming from 4 °C to 18 °C. What is the exchanger's effectiveness?

During open-heart surgery, a patient's blood is cooled down to 25 °C from 37 °C using a concentric tube counter-flow heat exchanger. Water enters the heat exchanger at 4 °C and leaves at 18 °C. Blood flow rate during the surgery is 5 L/minute.
Use the following fluid properties:
FluidDensity (kg/m3)Specific heat (J/kg-K)
Blood10503740
Water10004200
Effectiveness of the heat exchanger is _________ (round off to 2 decimal places).

Answer: 0.42 Official key: 0.40 to 0.44

  1. Blood: , . .
  2. Water: . This is the smaller capacity rate, so .
  3. .

The water flow rate isn't given and isn't needed: the water's temperature rise over the maximum possible difference gives directly, because water is the fluid. Using the blood's () is the trap.

Where this shows up in industry

Heart-lung machines really do include a heat exchanger like this to cool and later rewarm the patient's blood. Its limits are unusual: perfusion guidelines cap the water-to-blood temperature difference (about 10 °C), because large gradients can release dissolved gas from the blood as bubbles.

GATE 2023 · ME · Q.35NAT · 1 markHeat exchangers

Counter-flow exchanger, effectiveness 0.5, C = 1000 and 400 W/K, inlets 300 K and 350 K: what is the heat transfer rate?

Consider a counter-flow heat exchanger with the inlet temperatures of two fluids (1 and 2) being K and K. The heat capacity rates of the two fluids are W/K and W/K, and the effectiveness of the heat exchanger is 0.5. The actual heat transfer rate is _____ kW.
(Answer in integer)

Answer: 10 kW Official key: 9.999 to 10.001

  1. The largest possible heat rate is limited by the fluid with the smaller capacity rate: (here the hot fluid). .
  2. .
  3. Check: fluid 2 leaves at and fluid 1 at . For a counter-flow unit with this needs .

Trap: using gives 25 kW, which would cool fluid 2 by 62.5 K, below the 300 K inlet of fluid 1: impossible.

Where this shows up in industry

The effectiveness-NTU method rates an exchanger when only the inlet temperatures are known, for example checking an existing oil cooler or radiator at a new operating point. Exchanger rating software works the same way: the size gives NTU, NTU gives the effectiveness, and that gives the duty.

GATE 2022 · ME Set-2 · Q.64NAT · 2 marksHeat exchangers

150 kg/s of steam condenses at 200 °C, heating a fluid entering at 100 °C. With ε = 0.9, what is the fluid flow rate?

Saturated vapor at 200 °C condenses to saturated liquid at the rate of 150 kg/s on the shell side of a heat exchanger (enthalpy of condensation ). A fluid with enters at 100 °C on the tube side. If the effectiveness of the heat exchanger is 0.9, then the mass flow rate of the fluid in the tube side is ________ kg/s (in integer).

Answer: 1000 kg/s Official key: 1000 to 1000

  1. A condensing fluid stays at 200 °C, so its capacity rate is effectively infinite and the tube fluid is .
  2. , so and the tube fluid warms by 90 K.
  3. Heat released: , so .
Where this shows up in industry

Feedwater heaters in power plants work like this: steam bled from the turbine condenses on the shell side and preheats the boiler feedwater in the tubes. With one fluid changing phase, holds for any flow arrangement, which simplifies their design.

GATE 2024 · ME · Q.49NAT · 2 marksHeat exchangers

A condenser with 20,000 tubes at 1 kg/s each condenses 430 kg/s of steam at 50 °C. What is its effectiveness?

A condenser is used as a heat exchanger in a large steam power plant in which steam is condensed to liquid water. The condenser is a shell and tube heat exchanger which consists of 1 shell and 20,000 tubes. Water flows through each of the tubes at a rate of 1 kg/s with an inlet temperature of 30 °C. The steam in the condenser shell condenses at the rate of 430 kg/s at a temperature of 50 °C. If the heat of vaporization is 2.326 MJ/kg and specific heat of water is 4 kJ/(kg.K), the effectiveness of the heat exchanger is ________ (rounded off to 3 decimal places).

Answer: 0.625 Official key: 0.590 to 0.633

  1. Heat released by the steam: .
  2. Cooling water: , so it warms by , leaving at 42.50 °C.
  3. The steam is at constant temperature, so the water is : .
Where this shows up in industry

Roughly 1,000 MW goes into the cooling water here, typical for a plant of about 500 MW electrical output. Condenser performance sets the turbine back-pressure: a fouled condenser raises it and cuts the turbine's output.

GATE 2026 · ME · Q.55NAT · 2 marksHeat exchangers

A 1 m double-pipe exchanger: inner fluid 20 to 30 °C, outer fluid 60 to 40 °C. What is the heat transfer rate?

Convective heat transfer coefficients for Fluid 1 and Fluid 2 in a heat exchanger, as shown in the figure below, are 50 W/(m2K) and 80 W/(m2K), respectively. The inner tube is made of a material which has a thermal conductivity 386 W/(mK) for the given range of temperatures in the heat exchanger. The length of the heat exchanging surface, the inside radius of the inner tube, and thickness of the inner tube are 1 m, 10 mm, and 1 mm, respectively. Considering no heat exchange between the outer tube and the surrounding, the heat transfer rate for the heat exchanger is ________ W (rounded off to 1 decimal place).
Double-pipe heat exchanger: fluid 2 flows left to right through the inner tube from 20 °C to 30 °C; fluid 1 enters the annulus at the right at 60 °C and leaves at the left at 40 °CInlet of Fluid 2at 20 °CExit of Fluid 2at 30 °CExit of Fluid 1 at 40 °CInlet of Fluid 1 at 60 °CFluid 1 (annulus), h = 50 W/m²·KFluid 2 (inner tube), h = 80 W/m²·K

Answer: 50.5 W Official key: 49.5 to 51.5

  1. From the figure the flows are opposite (counterflow): fluid 2 (inside, ) goes 20 → 30 °C, fluid 1 (annulus, ) goes 60 → 40 °C.
  2. End temperature differences: and , so .
  3. Resistances per metre: inside ; wall ; outside .
  4. .

The copper wall () adds less than 0.01% of the resistance; the two convection films control everything.

Where this shows up in industry

This is why heat-exchanger designers attack the weaker film first: fins on the gas side of a car radiator or an AC coil, or turbulators inside tubes. Making the wall thinner or more conductive does almost nothing once it is metal.

From GATE prep to a Thermal and CFD career

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.