Pitot tube calculator (velocity, Mach number, airspeed, duct flow)
A pitot-static tube reads total minus static pressure, Δp. At low speed the velocity is V = √(2Δp/ρ): 500 Pa in sea-level air is 28.57 m/s. Type your reading in Pa, mmH₂O, inH₂O or as a manometer height, switch to the compressible or supersonic (Rayleigh) formula above Mach 0.3, convert IAS to TAS for an aircraft, or average a duct traverse into a flow rate. Free, no sign-up, runs in your browser.
Bernoulli · isentropic flow · Rayleigh pitot formula · US Standard Atmosphere 1976 · US EPA Methods 1 and 2 · checked against an independent solution (810 checks at build) · Updated 23 Nov 2026
What speed does my pitot-static reading mean (or what reading should a speed give)?
C = 1 for a standard (Prandtl, hemispherical-tip) pitot-static tube; US EPA Method 2 assigns a standard pitot tube a baseline 0.99. An S-type (reverse) probe must be calibrated: use its own C.
What are the Mach number and speed from a pitot-static reading at high speed, subsonic or supersonic?
Above Mach 1 the probe reads p₀₂, the total pressure behind the normal shock that stands in front of its tip. The static pressure must be the free-stream p₁ (from a wall tap or a probe ahead of the shock, not side holes behind it).
What are my aircraft's calibrated, equivalent and true airspeed and Mach number?
IAS is taken as CAS (no instrument or position error); use your aircraft's IAS to CAS table first. OAT is the static (outside) air temperature. Standard atmosphere from −610 to 20,000 m (65,600 ft).
What is the average velocity and flow rate in my duct from a pitot traverse?
| Point | From wall (% D) | From wall (mm) | Δp (Pa) | V (m/s) |
|---|
For each inlet velocity and gauge pressure, what total and static pressures should Fluent give, and what is the velocity error?
| Case | V in | p out (g) | p total tap | p static tap | abs total | M real air |
|---|
Back-calculate from your two Fluent report values
Defaults: the case 3 values of a public report (constant density, operating pressure 0).
Type what your report says for one case, leave blank what it does not. Each check gives a verdict and the number behind it.
How does a pitot tube measure velocity?
A pitot tube points its open tip into the flow. The fluid that meets the tip is brought to rest, so the tube fills to the stagnation (total) pressure p₀. A pitot-static, or Prandtl, tube adds a ring of small holes on its side, at right angles to the flow, which read the static pressure p. NASA Glenn's beginner's guide describes the aircraft version as "around 10 inches (25 centimeters) long with a 1/2-inch (1 centimeter) diameter", with "several small holes" around the outside and a centre hole down the axis. A manometer or pressure transducer across the two gives Δp = p₀ − p, the dynamic pressure, and Bernoulli's equation turns it into a speed:
Worked example (tab 1 default): a reading of 500 Pa in air at 101.325 kPa and 15 °C.
Use the density of the fluid that flows, at its own pressure and temperature, and keep units SI: Δp in Pa, ρ in kg/m³, V in m/s. The probe coefficient C is 1 for a standard hemispherical-tip pitot-static tube; Dwyer's bulletin H-11 for its ASHRAE-tip tubes says "test confirmed unity coefficient", and US EPA Method 2 assigns a standard pitot tube "a baseline coefficient value of 0.99". The S-type probes used in stacks are different and need their own calibrated C.
A manometer gives a height, not a pressure. A vertical U-tube with water reads 1 mm per 9.81 Pa; an inclined tube spreads the same height along a longer scale, which is why low-speed air is read on an inclined gauge:
HVAC charts work in feet per minute and inches of water. Dwyer bulletin H-11 gives the relation for air of density D (lb/ft³), with its standard air "dry air at 70°F., 29.9˝ Barometric Pressure and a resulting density of .075#/cu. ft.":
The often-quoted 4005√(Δp in inH₂O) is the same relation rounded. Working it in SI with the conventional inch of water (249.0889 Pa, NIST) and 0.075 lb/ft³ = 1.2014 kg/m³ gives 4,009; the three constants agree within 0.15%. Tab 1 prints the HVAC line whenever the fluid is air.
When does compressibility matter, and what is the compressible pitot formula?
Bernoulli's incompressible form holds when "the flow speed is much less than the speed of sound" (NASA Glenn). For a gas at higher speed, the stagnation pressure follows the isentropic relation (NASA Glenn, isentropic flow, eq 6), which gives the Mach number from the ratio of the two readings:
Worked example (tab 2 default): p₀ = 133 kPa and p = 101.325 kPa, static temperature 288.15 K.
The incompressible formula with the same Δp gives 227.4 m/s, 5.13% too high. How much it over-reads depends only on M (for γ = 1.4). Our numbers, from the two formulas above:
| M | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 |
|---|---|---|---|---|---|---|---|---|---|---|
| Speed over-read (%) | 0.13 | 0.50 | 1.13 | 2.01 | 3.15 | 4.56 | 6.23 | 8.19 | 10.42 | 12.94 |
| Density rise at the tip (%) | 0.5 | 2.0 | 4.6 | 8.2 | 13.0 | 19.0 | 26.3 | 35.1 | 45.6 | 57.7 |
The usual "Mach 0.3" rule checks out in this form: at M = 0.3 the air at the tip is 4.6% denser than the free stream, but the speed from the incompressible formula is only 1.13% high, because the speed goes with the square root of Δp. Below M 0.3 the error is under about 1%; at M 0.7 it is over 6%.
What happens above Mach 1? The Rayleigh pitot tube formula
In supersonic flow the probe cannot slow the air down smoothly. NASA Glenn's pitot page says that at supersonic speed "we've violated the assumptions of Bernoulli's equation" and "a shock wave appears that will change the total pressure". The shock in front of the tip is normal to the flow on the axis, so the tube reads p₀₂, the total pressure behind a normal shock. Multiplying the normal-shock total-pressure ratio (NASA Glenn, normal shock wave equations) by the isentropic ratio for the free stream gives the Rayleigh pitot formula:
The page computes it two ways, as this closed form and from the normal shock routine of the nozzle calculator, and the build checks that they agree to 10⁻⁹. It has no explicit inverse in M₁, so tab 2 finds M₁ by bisection (the ratio increases with M₁) and polishes it with Newton steps. At M₁ = 1 it equals the isentropic value 1.8929; above that the isentropic curve would read high, which the dashed line in the chart shows. Worked example: a wind tunnel run with p₀₂ = 450 kPa, p₁ = 50 kPa and a total temperature of 400 K.
Behind the shock the flow is subsonic (M₂ = 0.506) and has lost 52.9% of its total pressure. Total temperature does not change across a shock, so the T₀ → T step uses the free-stream M₁ either way. Using the incompressible formula here would give 889 m/s, 31% too high.
Indicated, calibrated, equivalent and true airspeed
An airspeed indicator is a pitot-static gauge with a fixed scale. "Airspeed indicators are calibrated on the assumption that they are operating at sea level in the International Standard Atmosphere where the air density is 1.225 kg/m3" (Wikipedia, International Standard Atmosphere). Calibrated airspeed (CAS) is "indicated airspeed corrected for instrument and position error"; it is the speed that would give the measured impact pressure qc at sea level. True airspeed (TAS) uses the actual static pressure and temperature, and equivalent airspeed (EAS) is the sea-level speed with the same dynamic pressure (Wikipedia, Calibrated airspeed and Equivalent airspeed pages):
a₀ = 340.29 m/s and p₀ = 101,325 Pa are the sea-level standard values. Tab 3 uses the subsonic forms below M 1 and the Rayleigh formula above it. The atmosphere is the 1976 US Standard (ICAO) troposphere, with the constants on the Wikipedia Barometric formula page (R* = 8.31432, M = 28.9644 kg/kmol, g₀ = 9.80665 m/s², lapse 6.5 K/km), and the isothermal layer from 11 to 20 km:
Worked example (tab 3 default): a trainer at 5,000 ft pressure altitude, ISA, indicating 100 kn (taken as CAS).
TAS is 7.7% above CAS at 5,000 ft, close to the rule of thumb that the indicator reads "about 2% less than TAS per 1,000 feet" (Wikipedia, True airspeed). On a day 15 °C warmer than ISA the TAS rises to 110.5 kn at the same CAS. The same page's example, 100 kn IAS at 15,000 ft is "actually flying at 126 knots", agrees with the exact ISA answer here, 125.8 kn. At these speeds EAS is within 0.1 kn of CAS; the gap grows at high altitude and Mach number.
How do you measure the flow rate in a duct with a pitot tube?
The velocity is not uniform across a duct, so one reading is not enough. A traverse takes readings at the centres of equal areas. For a round duct, US EPA Method 1 (40 CFR Part 60, Appendix A-1) places the points on two perpendicular diameters at the distances of its Table 1-2, which are the centroids of equal-area rings:
For 12 points this gives 2.1, 6.7, 11.8, 17.7, 25.0, 35.6, 64.4, 75.0, 82.3, 88.2, 93.3, 97.9% of D from the wall, the Table 1-2 column to the printed 0.1%. The verifier checks all six columns (2 to 12 points). Method 1 also keeps every point at least 2.5 cm from the wall in ducts over 0.61 m (1.3 cm in smaller ones); tab 4 moves points that fall closer and says so. For a rectangular duct it divides the section "into as many equal rectangular elemental areas as traverse points" and reads at the centroid of each.
Then turn every reading into a velocity and average the velocities. Dwyer's bulletin says to "calculate the velocities and average the readings". The reason: the velocity goes with the square root of Δp, and the average of square roots is smaller than the square root of the average. For the default profile (12 points across a 400 mm duct) the mean of the velocities is 17.14 m/s; the velocity from the mean Δp would be 17.28 m/s, 0.85% high. The more uneven the profile, the bigger the gap.
A short cut: Dwyer says that if a traverse is not possible, take the centre velocity and "multiply by a factor of .9 for the approximate average velocity", within ±5%. The default profile's mean is 0.903 of its peak. The same bulletin asks for straight duct "a minimum of 8 1/2 diameters in length upstream and 1 1/2 diameters downstream" of the probe for ±2% work.
The Fluent pitot tube challenge, solved
Skill-Lync's "Week 3 - Pitot tube" challenge (PG Program in CFD) gives a pitot-static tube mesh in a box, asks for a steady laminar run with a velocity inlet and pressure outlet, and asks you to "calculate the total and static pressures and find the error in percentage for velocity" for three inlet velocity and gauge pressure pairs: (240 m/s, −2,817 Pa), (100 m/s, 33,287 Pa) and (62 m/s, 65,780 Pa). Tab 5 does it. What decides the answer:
- Density. Fluent's default air has a constant density of 1.225 kg/m³. With constant density the flow is incompressible by construction, so Bernoulli with that same density is exactly what the solver should reproduce. If you change the density (some reports set 0.86 kg/m³), the formula must use the new value.
- Gauge vs absolute. With the operating pressure at 101,325 Pa, the boundary values are gauge, and the absolute static pressure of case 1 is 98,508 Pa. With the operating pressure at 0, the same −2,817 Pa becomes an absolute pressure below vacuum. A constant-density run does not notice, because only pressure differences move the flow; an ideal-gas run would compute ρ = p/RT < 0. Keep 101,325 Pa. (14 of the 50 public reports set it to 0.)
- Mach number. 240 m/s in air at 288.15 K is M = 0.705. The constant-density run has no compressibility, so the comparison is fair. A real probe in real air at that speed would read Δp = 38,779 Pa instead of 34,299 Pa, and the incompressible formula would over-read the speed by 6.33%.
Case 1 by hand, at Fluent's default density:
Expected total-tap values (gauge), ρ = 1.225: 32,463 Pa, 39,412 Pa, 68,134 Pa; with ρ = 0.86: 21,951 Pa, 37,587 Pa, 67,433 Pa. The static tap should read close to the outlet pressure. The error then is:
Writing Vcalc/Vinlet × 100 (for example 102.7) is a ratio, not an error: the error is 2.7%. As an example, a public report's case 3 values (68,199.465 and 65,714.526 Pa, density 1.225) give 63.69 m/s, an error of 2.73%. The few percent left over come from the probe and the mesh, not from compressibility: with constant density there is none, even at 240 m/s, and the reports' own tap pressures bear this out (corpus below).
One curiosity: 65,780 Pa is the standard-atmosphere pressure at 3,498 m, where the density is 0.863 kg/m³, and 33,287 Pa is the pressure at 8,461 m. That may be where the 0.86 kg/m³ that 13 of the 50 public reports use comes from. But −2,817 Pa cannot be an absolute pressure, so the table only makes sense as gauge values with the default operating pressure.
What 50 reports wrote
We read the 50 public reports titled "Week 3 - Pitot tube" (one is titled "Simulation of flow through Pitot tube") as of 23 Nov 2026, n = 50. 2 of them have little or no text to read (pictures only). Counts are of what the text shows, out of the reports shown as "of". Rows with 8 or 9 reports are marked: with n = 50 they are indications, not findings. The links are examples of reports that say it.
- 35 / 50State a % error for velocity. Largest stated error per report: under 1% (9), 1-2% (9), 2-5% (2), 5-10% (13), 10% or more (2). Only 6 write down how the error is defined. report 1report 2report 3
- 30 / 50Use incompressible Bernoulli, V = sqrt(2(p0 - p)/rho). Every report that turns the two tap pressures into a speed uses V = sqrt(2(p0 - p)/rho). None computes a Mach number or uses the compressible (isentropic) pitot relation, including for the 240 m/s case. report 1report 2report 3
- 25 / 50Back-calculate a velocity from the two tap pressures. Median back-calculated speeds: 239.3, 100.3 and 62.3 m/s for the 240, 100 and 62 m/s inlets; 60 of 75 values are within 3% of the inlet speed. report 1report 2report 3
- 22 / 50Mention compressibility or Mach number at all. 18 of these repeat that the formula holds only for incompressible / low-Mach flow; only 2 connect that to the 240 m/s case (one switches to a density-based solver for it). report 1report 2report 3
- 21 / 50State the air density used. Two camps: 0.86-0.8636 kg/m3 (13 reports) and the 1.225 kg/m3 sea-level default (7); one uses 1.125. In the 10 reports that write out the full substitution, 9 have a tap pressure difference within 0-4% of 1/2 rho V^2 for the density they used: the Fluent runs are constant-density (incompressible), including at 240 m/s. report 1report 2report 3
- 15 / 50State the Fluent operating pressure (0 or 101325 Pa). 14 set the Fluent operating pressure to 0 Pa (so the reported pressures are absolute); 1 keeps 1 atm. The rest do not say. report 1report 2report 3
Public reports titled "Week 3 - Pitot tube" (one titled "Simulation of flow through Pitot tube"). Counted from report text only (images not read). Pasted challenge text and headings removed first (lines found in 20% or more of reports). Image-only = under 500 characters of own text. Rows need 8 or more reports (n is small); rows under 10 are marked smallN.
These are first-party counts, a starting point rather than a measure of student ability. Tab 6 checks each of these numbers for your own report.
How we checked the calculator
An independent Python script, scripts/verify/pitot.py, rebuilds every number with its own code, and this page refuses to build if the browser code differs from it in any of 810 numbers (127 further assertions run inside the script). It computes the Rayleigh formula from the NASA normal-shock total-pressure ratio times the isentropic ratio, compares it with the closed form and with the supersonic calibrated-airspeed formula printed on Wikipedia (solved by its own iteration), and finds M from a pressure ratio by plain bisection; checks the standard atmosphere against the printed values (101,325 Pa and 1.225 kg/m³ at sea level, 22,632.1 Pa, 216.65 K and 0.3639 kg/m³ at 11 km); checks that CAS = EAS = TAS at sea level; checks the equal-area positions against all six columns of EPA Table 1-2; compares the HVAC constant with Dwyer's 1096.2√(Pv/D); and recomputes the three challenge cases and the report checker's verdicts. Two deliberate bugs (the isentropic exponent γ/(γ−1) changed to (γ−1)/γ, and the Rayleigh exponent γ/(γ−1) changed to 1/(γ−1)) each make the build fail.
What this calculator does not cover
- Probe errors. Yaw, blockage, wall proximity, turbulence and low Reynolds number at the tip change the reading. NASA Glenn notes that at very low speed "the difference in pressures is very small and hard to accurately measure". The coefficient C is the only correction here.
- Air only for the gas tabs. Tab 2 takes any γ and R; tabs 3 to 6 assume dry air (γ = 1.4, R = 287.05 J/kg·K). Humidity is ignored.
- Atmosphere. Standard atmosphere to 20 km. IAS is taken as CAS: position and instrument errors come from the aircraft's own table.
- Traverses. Equal-area points from EPA Method 1; log-Tchebycheff positions are not given because we could not read a free source for them. No correction for swirl or for points near disturbances.
- The Fluent case. Expected tap values are ideal (inviscid, probe without blockage); the CFD will differ by a few percent through the probe and mesh.
The pitot tube challenge is part of Skill-Lync's PG Program in CFD, where Bernoulli, compressible flow and Fluent post-processing lead to external aerodynamics and nozzle projects.
Frequently asked questions
How does a pitot tube work?
The tube points into the flow. The open tip brings the fluid to rest, so it reads the stagnation (total) pressure. Holes on the side, at right angles to the flow, read the static pressure. The difference is the dynamic pressure, ½ρV², which a manometer or transducer measures and Bernoulli turns into a speed.
What is the pitot tube velocity formula?
For a liquid, or a gas below about Mach 0.3, V = C√(2Δp/ρ), where Δp is total minus static pressure in pascals, ρ is the fluid density in kg/m³ and C is the probe coefficient, about 1 for a standard Prandtl tube. At higher speeds use the compressible relation in tab 2.
What is the difference between a pitot tube and a pitot-static tube?
A plain pitot tube has only the open tip and reads total pressure; the static pressure must come from a separate wall tapping. A pitot-static, or Prandtl, tube adds a ring of side holes on the same body, so one probe gives both pressures and their difference directly. Aircraft and ducts mostly use the combined probe.
What are stagnation, static and dynamic pressure?
Static pressure is what the moving fluid exerts on a surface parallel to the flow. Stagnation, or total, pressure is what it reaches when brought to rest without losses. Dynamic pressure is the difference, ½ρV² for incompressible flow. A pitot-static tube reads the first two; the speed follows from the third.
When is compressibility important for a pitot tube?
Incompressible Bernoulli over-reads the true speed by 0.5% at Mach 0.2, 1.1% at Mach 0.3, 3.2% at Mach 0.5 and 6.2% at Mach 0.7, computed from the isentropic relation. Above about Mach 0.3 use the compressible formula; above Mach 1 a shock stands in front of the probe and the Rayleigh formula applies.
What is the Rayleigh pitot tube formula?
In supersonic flow a normal shock forms just ahead of the pitot tip, so the tube reads the total pressure behind the shock, p₀₂. The Rayleigh pitot formula relates p₀₂ to the free-stream static pressure p₁ through the free-stream Mach number. It has no explicit inverse, so tab 2 finds M₁ by root finding.
What is the difference between IAS, CAS, EAS and TAS?
IAS is what the airspeed indicator shows. CAS is IAS corrected for instrument and position error. Both assume sea-level standard air. EAS also removes the compressibility effect at altitude, and TAS is the actual speed through the air, higher than CAS at altitude because the air is thinner: about 7.7% at 5,000 ft.
Why do pitot tubes ice up, and what happens?
A pitot tube that collects ice can no longer bring the air to rest at its tip, so the pressures at the transducer are not the true total and static values and the indicated speed is wrong. NASA Glenn notes that airliner probes had icing problems and that the fix was to heat the probes.
How do you measure duct airflow with a pitot tube?
Traverse the duct: take readings at the centres of equal areas, 2 to 12 points on each of two diameters for a round duct (US EPA Method 1 Table 1-2). Turn each reading into a velocity, average the velocities, not the pressures, and multiply by the duct area for the volume flow.
Which units are used for pitot tube readings?
Pascals in SI, often kPa or mbar. Manometers read millimetres or inches of water: 1 mmH₂O = 9.80665 Pa and 1 inH₂O = 249.09 Pa (conventional, NIST). HVAC charts use V in ft/min = 1096.2√(Pv/D) with Pv in inH₂O and D in lb/ft³, about 4,003√Pv for 0.075 lb/ft³ air.
Related on Skill-Lync
- Converging-diverging nozzle calculator (isentropic ratios and the normal shock this page reuses)
- Oblique shock and Prandtl-Meyer calculator (shocks at an angle and expansion fans)
- NACA airfoil calculator (lift and Cp; the free-stream speed this page measures)
- Drag force calculator (drag from the same dynamic pressure, ½ρV²)
- Flow bench calculator (inches of water to flow through an engine port)
- Pipe flow calculator (laminar pipe velocity profile and pressure drop)
- CFD courses compared
- All free engineering tools
Sources
- NASA Glenn Research Center, Beginner's Guide to Aeronautics: Pitot-Static Tube (Speedometer); Bernoulli's Equation; Isentropic Flow Equations (eq 6 to 8); Normal Shock Wave Equations; Earth Atmosphere Model.
- US Standard Atmosphere 1976 / ICAO constants and layer values as tabulated on Wikipedia, Barometric formula and International Standard Atmosphere.
- Wikipedia, Calibrated airspeed (subsonic and supersonic CAS formulas, a₀, p₀), Equivalent airspeed, True airspeed (2% per 1,000 ft, 15,000 ft example).
- US EPA, Method 1 (40 CFR 60 Appendix A-1): Table 1-2 traverse point locations, wall clearance, rectangular stacks. Method 2: standard pitot tube coefficient 0.99.
- Dwyer Instruments, Bulletin H-11, Series 160 Stainless Steel Pitot Tubes (2005): 1096.2√(Pv/D), standard air, traverse and 0.9 centre factor, straight runs.
- NIST Special Publication 811, Appendix B.8 (inch and millimetre of water, ft/min, lb/ft³, knot).
- Skill-Lync, the 50 public reports titled "Week 3 - Pitot tube", read 23 Nov 2026.