Flow bench calculator: CFM at 28 inH₂O, L/D, curtain area and valve Cd

A flow bench measures a port at a small, fixed pressure drop, usually 28 inches of water (6.974 kPa). Flow scales with √Δp between bench pressures, so 183 CFM at 10 inH₂O is 306.2 CFM at 28. Type a valve and a lift for the curtain area, L/D and minimum flow area. Type a bench reading for the discharge coefficient and the flow at another test pressure. Free, runs in your browser.

The third tab takes a CFD lift sweep run at 2 atm back to what the same port flows at 28 inH₂O. The fourth checks a report on the flow bench challenge from Skill-Lync's Flow Simulation using SolidWorks course. Skill-Lync read all 177 public flow bench reports to build it.

Heywood (1988) valve area as printed in Sci Rep 2025 · NASA Glenn choked flow · NIST SP 811 · SuperFlow · checked against a separate solution (2,144 checks at build) · Updated 23 Nov 2026

D is the outer diameter of the valve head (the seat face starts there); the inner seat diameter sets the seat width w = (D − Dᵢ)/2. The seat angle is measured from the valve head face: 45° is the usual cut. Defaults are a 40 mm intake valve.

L/D0.2510 mm on a 40 mm valve
Curtain area1,257 mm²π·D·L
Minimum flow area869 mm²stage 3 (port minus stem)
QuantityValueAlso
L/D0.25L/Dᵢ 0.2778 on the inner seat
Curtain area πDL1,257 mm²1.445 × the port
Minimum flow area869 mm²stage 3 (port minus stem)
Port minus stem869 mm²port alone 908 mm²
Seat width w, mean seat D_m2 mm38 mm
Stage 1 ends at4 mmL/D 0.1
Port limits from9.003 mmL/D 0.2251
Curtain = port at6.919 mmL/D 0.173
  • The port takes over at L/D 0.2251: above it, more lift adds no flow area. Curtain area passes the port earlier (L/D 0.173) because it ignores the seat angle.
Valve flow area against L/D: curtain area πDL, the three-stage minimum flow area and the port area; curtain equals port at L/D 0.1730.00.10.20.30.4050010001500port minus stem 869.4 mm²stage 1|2, L/D 0.1port limits, L/D 0.2251curtain = port at L/D 0.173lift / valve diameter, L/Dflow area, mm²— minimum flow area— curtain π·D·L

What is a flow bench, and why 28 inches of water?

A flow bench pulls air through a cylinder head port at a fixed, small pressure difference and measures the flow, one valve lift at a time. The pressure is read on a water manometer, so it is quoted in inches of water: 1 inH₂O is 249.1 Pa, about 0.03613 psi. Most tests run at 10 or 28 inH₂O, 2.5 to 7 kPa. SuperFlow rates its small SF-260 for 10 inH₂O and its larger SF-750 for 28.

28 inH₂O (6974 Pa) is a convention. A running engine sees far larger and changing pressure differences; the bench holds one steady value so two ports can be compared. A number measured at another pressure has to be converted before it is compared with anyone else's.

How do you convert flow bench CFM between test pressures?

At bench pressures the air hardly compresses, so velocity, and with it the volume flow, follows the square root of the pressure drop:

183 CFM at 10 inH₂O becomes 183 × √2.8 = 306.2 CFM at 28. Century Performance's chart prints 1.670 and 305.6 CFM for the same case. The rule keeps the discharge coefficient constant and ignores compressibility. Skill-Lync's calculator also works the isentropic answer at the same Cd; the two part as Δp grows (180 CFM at 28 inH₂O through the default curtain):

New test pressure√Δp ruleIsentropic, same Cd√Δp is off by
10 inH₂O107.6 CFM110.3 CFM-2.5%
25 inH₂O170.1 CFM170.8 CFM-0.4%
10 kPa215.5 CFM211.8 CFM+1.8%
25 kPa340.8 CFM303.8 CFM+12.2%
50 kPa481.9 CFM345.2 CFM (choked)+39.6%
60 kPa527.9 CFM345.2 CFM (choked)+53.0%

Between 10 and 28 inH₂O the two agree within about 2.5%. At 50 kPa the square-root rule is 39.6% high, and past about 48 kPa from 1 atm the gap chokes and flow stops rising at all.

What is the valve curtain area, and what does L/D mean?

The curtain is the side of the cylinder that the lifted valve uncovers. Lift is quoted as a fraction of the valve diameter so different valves share one chart:

Engines open to about L/D 0.35, and benches read at 0.05, 0.1 up to 0.3. The curtain grows with lift, the port does not, so they cross where

which is L/D 0.25 for a port as wide as the valve with no stem. The default 34 mm port and 7 mm stem on a 40 mm valve cross at L/D 0.173.

The curtain is not the smallest gap the air sees. Heywood's Internal Combustion Engine Fundamentals (1988) splits the minimum area into three lift stages; we took them from the open-access paper by Chandrakar, Penmatsa and Mittal (IIT Madras, Sci Rep 2025), not from the book. With seat width w and seat angle β:

Skill-Lync's verifier rebuilt each stage from coordinates of the seat and valve. Two printed details did not survive that check: the stage-3 limit needs the square shown above, and D_m must be D − w (the paper prints D − 2w, which leaves a jump between stages 1 and 2). For a small port the port can take over while still in stage 1; the calculator handles that too.

What is the discharge coefficient of a valve?

The flow you measure divided by the flow an ideal, loss-free opening of the reference area would pass at the same pressures:

The ideal flow has two common forms. Bernoulli at the upstream density, and the isentropic nozzle flow:

At 28 inH₂O and 20 °C the Bernoulli form is 3.9% higher (at 10 inH₂O, 1.3%), so a Cd changes by that much depending on which you use. The reference area matters more. It can be the curtain, the seat, the head or the port throat, and each gives a different Cd; none is the true minimum area. On the curtain a valve sits around 0.6, falling slowly with lift as the jet separates from the seat. The default bench reading, 180 CFM through the 10 mm curtain of a 40 mm valve, is Cd 0.6526.

Why is a 2 bar CFD run not a flow bench number?

Because the valve is choked. Air reaches the speed of sound in the narrowest gap once the downstream pressure falls to 0.528 of the upstream total pressure (γ = 1.4). From there the flow depends only on p₀, T₀ and the area:

2 atm into 1 atm is a ratio of 0.5, below 0.528. 101,325 Pa into 51,325 Pa (0.507) is choked too. 151,325 into 101,325 (0.67) is not, but its 50 kPa drop is 7.169 times a 28-inch bench. Lowering the outlet of a choked run adds nothing, so its mass flow cannot be scaled to the bench with √Δp.

What carries over is the discharge coefficient, if it stays roughly constant with pressure (the bench literature only says it "may change somewhat"). For the default report, Cd on the curtain runs from 0.4056 at 1 mm to 0.7303 at 8 mm. At 28 inH₂O that port would flow 12.59 to 181.3 CFM. Scaling the CFD flow by √Δp instead gives 91.2 CFM at full lift, 49.7% low.

To make the CFD run the bench test, set the port inlet to 101,325 Pa total and the cylinder lid to 94,351 Pa static (1 atm minus 28 inH₂O). The converging-diverging nozzle calculator covers the same choking in a nozzle.

What did 177 flow bench reports set up?

Skill-Lync read every public report on the flow bench challenge on 23 Nov 2026 (n = 177) and recorded what each says in its text, with the line quoted (900 quotes, each checked against the report). Text in screenshots is not counted: 54 reports give no pressure or velocity in their text, so every count is a floor. The pressures are as written, read as absolute (the reports' own default initial condition is 101,325 Pa):

Set-up across the valveWhat it meansReportsExamples
Choked: p_out/p₀ ≤ 0.528Mach 1 in the valve gap; more outlet suction adds no flow781, 2
Compressible, not choked: Δp above 7 kPaFaster than a bench; √Δp scaling is off221, 2
Flow bench range: Δp up to 7 kPaWhat a bench does (10 to 28 inH₂O)21, 2
Outlet at or above the inletNothing should flow in71, 2
Velocity inlet instead of pressuresFixes the flow, so the sweep measures nothing71, 2
Inlet pressure onlyOutlet value not in the text71, 2
No pressure or velocity in the textSet-up only in screenshots, or not given541, 2

The pressure pairs used most often (Mach is the ideal jet at 293 K):

Inlet → outlet (Pa)p_out/p₀× a 28″ benchIdeal MachRegimeReportsExample
401,325 → 101,3250.2525431choked14report
172,369 → 101,3250.5878100.9053compressible10report
200,000 → 100,0000.5141choked8report
202,650 → 101,3250.5151choked7report
405,300 → 101,3250.25441choked6report
101,325 → 51,3250.506571choked4report
501,325 → 101,3250.2021571choked4report
100,000 → 50,0000.571choked3report
202,650 → 50,6620.25221choked3report
  • 78 of the 109 reports that state both pressures run a choked valve, most often 401,325 into 101,325 Pa (1 atm plus 3 bar, ratio 0.25). Only 2 stay within a bench's 7 kPa, and one of those (11,000 into 10,000 Pa) is at a near-vacuum.
  • 6 of the 9 that mention inches of water or a 28-inch test then set a choked run (1, 2). One quotes the 2.5 to 7 kPa bench range and then puts 3.5 kPa absolute on the outlet (report), a 98 kPa drop.
  • Pressures the wrong way round: 5 put 200,000 Pa on the cylinder lid against 101,325 Pa at the port (1, 2), and 2 type the same value on both lids.
  • Velocity inlets: 7 fix an inlet velocity (2 to 2,000 m/s) instead of a pressure difference, which sets the flow before the valve has a say.
  • Lifts: 162 state their lifts; 120 sweep from about 1 mm to 6 to 12 mm, and the median top lift is 8 mm.
  • Mass flow: 65 print their mass flows in text, 54 in kg/s and 11 with no unit. 35 print them negative, and 61 explain the minus sign as mass leaving the domain, which is right: it is only a direction.
  • Lift curves that dip: of 49 with a lift table in text, 6 have a flow that falls by 2% or more as lift rises (1, 2); 3 of them use a velocity inlet.
  • Grid tests: 163 describe one; 26 give the goal on each grid in text. One picks the finest grid after a 17.25% jump in its goal (report).
  • Bench units: 11 mention cubic feet per minute and 18 a discharge or flow coefficient, in copied theory; none gives a CFM figure, and 1 compares its own flow with an ideal orifice. None checks the pressure ratio for choking.
  • Unit labels: 3 write a Pa value as "bar" (175,000 bar) and 1 as "kPa".

Can CFD replace a flow bench?

It can stand in for one test if it copies the test: atmosphere at the port, 28 inH₂O less in the cylinder, the real valve and seat, and a mesh whose mass flow no longer moves between the two finest grids. Then the CFD flow and the bench flow are the same quantity and the Cd is comparable. It still needs a bench to show it is right. Neither the bench nor steady CFD sees the pulsing flow, fuel or hot exhaust of a running engine.

What this calculator does not cover

  • A Cd that changes with pressure. Converting a CFD result to the bench assumes the discharge coefficient is the same at both pressures. Reynolds number and, at 2 bar, shock structure in the jet can change it.
  • Swirl and tumble. Benches measure them with extra instruments; this page does flow only.
  • Exhaust ports, which run hot and often choked in a real engine.
  • Standard-condition corrections that bench software applies (SCFM). Here CFM is volume at the air density you type.
  • hp-per-CFM rules of thumb. We found no source we could read that states one, so there is none here.
Learn CFD on a real port

Meshing a port is the easy part. Setting the bench's pressures, proving the grid with a number and turning mass flow into a Cd is what CFD teams look for. The flow bench is a project in Skill-Lync's Flow Simulation using SolidWorks course.

Frequently asked questions

What is a flow bench?

A rig that pulls or pushes air through an engine part, usually a cylinder head port with its valve held open, at a fixed small pressure difference and measures the flow. Most tests run at 10 or 28 inches of water (2.5 to 7 kPa). Results are given in CFM against valve lift, so ports can be compared.

Why do flow benches test at 28 inches of water?

It is a convention, not physics: 28 inH₂O (6.974 kPa, about 1 psi) is the standard most published head-flow numbers use, and SuperFlow rates its larger benches up to it. Smaller benches run at 10 inH₂O. Any pressure works if you convert the result before comparing.

How do you convert CFM between test pressures?

Multiply by the square root of the pressure ratio: Q₂ = Q₁ √(Δp₂/Δp₁). 183 CFM at 10 inH₂O is 183 × √2.8 = 306.2 CFM at 28. The rule assumes incompressible flow and a constant discharge coefficient, so it holds across bench pressures and drifts past about 10 kPa.

What is the valve curtain area formula?

Curtain area is the side of the cylinder the open valve uncovers: A = π × D × L, with D the valve head diameter and L the lift. A 40 mm valve at 10 mm lift has 1,257 mm². The real minimum area is smaller: the seat angle and, at high lift, the port set it.

What is L/D in port flow?

Lift divided by valve diameter, usually the head diameter. It lets valves of different sizes share one chart. Engines open to about L/D 0.35 at most, and benches read flow at 0.05, 0.1 up to 0.3. Near L/D 0.25 the curtain area equals the port area, so the port starts to limit flow.

What is the discharge coefficient of a valve?

The measured mass flow divided by the ideal flow through a reference area at the same pressures. On the curtain area a valve sits around 0.6, falling slowly with lift. The number depends on which area you pick (curtain, seat, port), so always say which one you used.

Can CFD replace a flow bench?

It can predict a bench test if you give it the bench's conditions: atmosphere at the port and 28 inH₂O less at the cylinder, a converged mesh and the real geometry. It cannot prove itself; a bench measurement checks it. Running 2 bar instead tests a choked valve, not the bench.

Related on Skill-Lync

Sources

  • Chandrakar, Penmatsa and Mittal, "Thermodynamics based modeling of various in-cylinder processes and spark ignition engine cycle with a focus on sub-models assessment", Scientific Reports 15 (2025), open access: the three-stage valve flow area (after Heywood, 1988), the isentropic mass flow and Cd as actual over isentropic flow. Heywood's book itself was not read.
  • NASA Glenn Research Center, Mass Flow Choking: mass flow against Mach number and the choked flow at M = 1.
  • Wikipedia, Air flow bench: 10 and 28 inH₂O (2.5 to 7 kPa), L/D up to 0.35, reference areas for the flow coefficient, V = √(2H/d), bench limitations.
  • SuperFlow Flowbenches brochure (Carlson Company): SF-260 rated to 10 inH₂O, SF-750 to 28 inH₂O. Century Performance, Airflow Conversion Chart: 183 CFM at 10″ = 305.6 CFM at 28″. Banks Power: 1 inH₂O ≈ 0.036 psi.
  • Colorado State University (A. Allan), Intake Flow: A = πDL and a representative Cd of 0.6; Geometric Properties: attached jet at low lift, free jet at high lift.
  • NIST SP 811, Appendix B.9: inch of water (conventional) 249.0889 Pa, ft³/min 4.719474 × 10⁻⁴ m³/s, psi 6,894.757 Pa. Air: γ = 1.4, R = 287.05 J/(kg·K).
  • Skill-Lync, all 177 public flow bench reports, read 23 Nov 2026; 900 quoted lines, each checked against the report text. scripts/verify/flow_bench.py recomputes every case another way (valve areas from seat coordinates, stage limits by bisection, mass flow from NASA's Mach-number form, unit sizes typed from NIST, the Century and Wikipedia figures), 112 cases; the page checks itself against it at build time (2,144 checks).
Free counselling

From a flow bench to a CFD job.

Knowing why a 2 bar run is choked, or what Cd your port really has, is the kind of answer CFD teams look for. A Skill-Lync counsellor can map the SolidWorks, CFD or IC engine course that fits the role you want.

Talk to a CFD course counsellor

Free. We call you back, usually the same day.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.