GATE Instrumentation (IN): Electrical Circuits and Machines (network theorems, transients, AC power, coupled inductors, transformers, induction motors), previous-year questions solved, part 2
Part 2 of 4 of the Electrical Circuits and Machines hub: 7 more official GATE IN questions on AC circuits: phasors, power and RMS values, each solved step by step and checked against the official answer key. The other parts cover DC networks, network theorems and two-ports, transients in RC, RL and RLC circuits, resonance, coupled inductors and passive filters and transformers and electrical machines.
Questions from official GATE IN papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 19 Nov 2026 · 7 of 30 questions on this page
Load of R1 in parallel with C1, in series with L1 and R2, driven by 100 V at 50 Hz: power factor
Answer: (leading) Official key: 0.8 to 0.8
- Power factor is the cosine of the angle of the load impedance, . So find the total impedance of the load as a complex number at .
- Reactances: and .
- in parallel with : .
- Add the series parts: , so .
- . The reactance is negative, so the current leads the voltage: the power factor is 0.8 leading.
Trap: leaving out (or putting it in series) changes the impedance completely: without the load would be with a power factor of . Check in code: at , and .
Power factor tells an electrician how much of the current drawn by a load does useful work. Capacitive and inductive elements in the same branch partly cancel, which is exactly how power factor correction capacitors are sized for motor loads and instrument supplies.
1 kHz generator, 50 ohm source, 10 Vp-p open circuit falls to 8 Vp-p with a capacitor: capacitance
Answer: Official key: 2.35 to 2.43
- The generator is an ideal source in series with its internal resistance. With the capacitor across the output, the capacitor and the resistance form a voltage divider, but the capacitor voltage is at to the voltage across the resistance, so the magnitudes add as a right triangle, not as a sum.
- The output (capacitor) voltage is . Peak-to-peak values scale the same way as peak or rms, so the ratio is .
- Solve: .
- , so .
Trap: treating the capacitor like a resistor, , gives and , which is far off. Reactance and resistance are apart, so they combine in quadrature. Re-evaluated in code with : the output-to-open-circuit ratio is .
Every real source has an output impedance, and a cable or sensor input capacitance across it forms exactly this divider. Measuring how much the amplitude drops at a known frequency is a standard way of finding an unknown capacitance, or of judging how much a long cable will round off a fast sensor signal.
Average power absorbed by a circuit with a DC plus two-harmonic voltage and a two-harmonic current
The average power absorbed by the circuit is __________ W (rounded off to nearest integer).
Answer: Official key: 200 to 200
- Average power of a signal with several frequencies is the sum of the average powers at each frequency taken separately, because terms at different frequencies average to zero when multiplied together. At a frequency where both voltage and current exist, , where is the phase of the voltage minus the phase of the current.
- Read the frequencies. is , is and is .
- DC: the voltage has a term but the current has no DC term, so the DC power is .
- : at and at , so and .
- : only the current has this component, so the power is . : only the voltage has it, so the power is .
- Total .
Trap: pairing every voltage term with a current term without checking the frequencies, for example adding for the and terms, or using the angle twice. Only harmonics that appear in both and deliver power. We checked by multiplying and averaging it over ten common periods of numerically: the mean is .
Power meters and energy meters on drives and rectifier-fed loads work with distorted waveforms like this one, and only harmonics present in both voltage and current count towards real power. A distorted current at a different frequency from the voltage heats the wiring but earns no energy.
RMS value of a current with a DC term and sine and cosine terms at two frequencies
The root-mean-square value of is __________ A (rounded off to one decimal place).
Answer: Official key: 27.0 to 30.0
- The rms value is the square root of the mean of . Terms at different frequencies are uncorrelated, so their mean-square values add. A constant contributes its value squared, and a sinusoid of amplitude contributes .
- Combine the cosine and sine at each frequency into one amplitude, using with amplitude . At : . At : .
- Mean square: .
- , which lies in the official range of to .
Trap: adding the rms values of the components directly (), or adding the cosine and sine amplitudes linearly before squaring. Quadrature sums are the rule. We also averaged numerically over one full period of and got .
True-rms meters and power analysers must account for every harmonic and any DC offset in the waveform, which is why an average-responding meter reads wrongly on non-sinusoidal current. The same quadrature sum is used to find the heating effect of a rectifier or inverter current.
Admittances -j0.2 S, 0.3 S and j0.4 S in parallel on 10 angle 45 deg V: phase of Ib + Ic against total current
- (A) leads by
- (B) lags by
- (C) leads by
- (D) lags by
Answer: (A) Official key: A
- For parallel branches, each branch current is the branch admittance times the same source voltage: . The total is .
- Total admittance: , so . Its angle is .
- The partial sum: (it leaves out ), so with angle . Only the admittance angles matter for the phase difference, because is in both.
- . It is positive, so is ahead: leads by . Option (A).
Trap: option (C) takes the angle of itself relative to the source as if it were the difference. Options (B) and (D) get the lead and lag the wrong way round: a larger angle means a phasor that is further ahead (leading). We computed both phasors with complex arithmetic: , , a difference of .
Adding branch currents as phasors is how engineers size the supply for a mixed resistive, inductive and capacitive load, such as a sensor bridge excitation or a motor with a power-factor capacitor. A capacitive branch partly cancels an inductive one and changes the phase of the total current drawn from the source.
Active power from a 100 angle 0 deg V source: -j10 and 10 ohm in series with (5 - j5) ohm parallel j5 ohm
Answer: Official key: 590 to 610
- Active (real) power is the power the resistors dissipate. A convenient route for a single source is , where is the source current. First find the total impedance seen by the source.
- The parallel pair: .
- Add the series branch : , with .
- Source current: .
- , which is equivalent to (inside the key range 590 to 610).
Trap: using (apparent power, 632.5 VA, with ) or forgetting that the capacitor and inductor absorb no active power, so that only the 10 and 5 resistors count. The 100 V is read as an rms value, which gives 600 W, the key's value. We checked it by adding the powers dissipated in the resistors, with , and found the same 600.0 W.
Only the resistive part of a load turns electrical energy into heat or work, so active power is what a supply bill and a heater rating are based on, while reactive elements swap energy back and forth. The same split is used when checking the power factor of instrumentation and motor loads.
Series RL circuit, current lags the source by 45 degrees, R = 100 pi ohm and L = 2 H: source frequency
Answer: Official key: 25 to 25
- In a series circuit the current phasor is , so the current lags the voltage by .
- A lag of means , so the inductive reactance equals the resistance: .
- .
- .
Trap: stopping at and writing it as hertz, about 157 Hz. That frequency would put the current 81.0 degrees behind the voltage, not 45. We swept the frequency of and found the current lag equal to 45 degrees at 25.00 Hz.
The 45 degree point of an RL pair is its corner frequency, where reactance equals resistance. Instrument designers use it to set the bandwidth of RL smoothing filters and to estimate the lag a coil adds to a measured current.