Electrical Machines cover
Interactive book · Semester 3-5

Electrical Machines

Build up a DC generator's voltage, load a transformer, slide an induction motor along its torque-slip curve and swing an alternator through its V-curves in your browser

Eighteen chapters, 19 interactives, few words. Every chapter is mapped to the Anna University, VTU, SPPU, Mumbai University and KTU units it covers: magnetic circuits and energy conversion, DC generators and motors and how to test them, single-phase and three-phase transformers, three-phase and single-phase induction motors with their starters and speed control, alternators, synchronous motors, and the special machines that drive EVs, drones and 3D printers: BLDC, PMSM, stepper and switched reluctance motors.

  • AUEE3303Electrical Machines - I
  • AUEE3405Electrical Machines - II
  • VTUBEE304Transformers and Generators
  • VTUBEE401Electric Motors
  • SPPU203146Electrical Machines-I
  • SPPU303143Electrical Machines-II
  • MUEEC303Fundamentals of Electrical Machines and Measurements
  • MUEEC402Electrical AC Machines-I
  • MUEEC501Electrical AC Machines-II
  • KTUPCEET303DC Machines and Transformers
  • KTUPCEET402Synchronous and Induction Machines

By Skill-Lync · Updated 17 Nov 2026 · 18 chapters · 19 interactives · free, no sign-up

Chapter 1

Magnetic circuits and electromechanical energy conversion

Which syllabus covers thisAU EE3303 Unit IVTU not in syllabusSPPU 203146 (prerequisite)MU EEC303 Modules 1-2KTU not in syllabus

What is a magnetic circuit?

A loop of iron that carries flux the way a wire carries current. The coil's ampere-turns are the driving force (MMF), flux is the current, and reluctance is the resistance. Iron has a relative permeability in the thousands, so a 1 mm air gap can have more reluctance than 40 cm of core. Push the current up and the iron saturates.

Magnetic circuit with an air gap: flux, reluctance, inductance and the pull on the armature: interactive loads as you scroll

What are statically and dynamically induced EMF?

Faraday's law: a changing flux linkage induces an EMF. If the coil is still and the flux changes, as in a transformer, the EMF is statically induced: . If a conductor moves through a steady field, as in a generator, it is dynamically induced: . Lenz's law gives the direction: the EMF opposes the change that causes it.

How does a magnetic field produce force: energy and co-energy?

Energy from the source goes into the field and into mechanical work. The force on a moving part is the rate at which co-energy rises as it moves, at constant current: . Almost all the stored energy sits in the air gap, so the pull on an armature is per pole face. Torque in rotating machines comes from the same balance.

What are singly and doubly excited systems?

A singly excited system has one coil: a relay or a reluctance motor, where torque comes only from the rotor lining up with the flux (reluctance torque). A doubly excited system has coils on both stator and rotor, so their fields interact: torque is proportional to , the angle between them. Every DC, induction and synchronous machine is doubly excited.

Where do hysteresis and eddy-current losses come from?

Every AC cycle drags the iron round its hysteresis loop; the loop area is energy lost, proportional to frequency (Steinmetz: ). The changing flux also induces circulating eddy currents in the iron, losing power in proportion to . Thin insulated laminations of silicon steel cut both, which is why every AC machine core is laminated.

Predict, then check

A coil drives flux round an iron core. You cut a 1 mm air gap in the core. To keep the same flux, the current must:

Worked examples

Core with an air gap · Core 0.4 m, A = 4 cm², μr = 4000, gap 1 mm, N = 500, want B = 1 T
  1. = 198,944 A/Wb; = 1,989,437 A/Wb
  2. = 0.4 mWb, so = 875 AT, I = 1.75 A
  3. = 114 mH; the gap takes 91% of the MMF

Answer: 1.75 A, L ≈ 114 mH

Pull on an armature · B = 1 T across two pole faces of 4 cm² each, gap 1 mm
  1. = 159.2 N per face
  2. Energy in one gap = = 0.159 J

Answer: 318 N on the armature

Induced EMF, both kinds · A 0.3 m conductor at 10 m/s across 0.8 T; a 200-turn coil whose flux changes by 2 mWb in 0.1 s
  1. Dynamic:
  2. Static:

Answer: 2.4 V and 4 V

Separating hysteresis and eddy loss · Core loss 100 W at 50 Hz and 130 W at 60 Hz, same peak flux density
  1. : 50a + 2500b = 100 and 60a + 3600b = 130
  2. b = 0.01667, a = 1.1667
  3. At 50 Hz: hysteresis = 50a = 58.3 W, eddy = 2500b = 41.7 W

Answer: 58.3 W hysteresis + 41.7 W eddy current

Chapter 2

DC machines: construction, windings and the EMF equation

Which syllabus covers thisAU EE3303 Unit IIVTU BEE401 Module 1SPPU 203146 Unit 3MU EEC303 Module 3KTU PCEET303 Module 1

What are the parts of a DC machine?

The stator is a steel yoke carrying field poles with pole shoes and field windings; it also completes the magnetic path. The rotor (armature) is a laminated slotted core carrying the armature winding, connected to a commutator of copper segments. Carbon brushes press on the commutator and lead current in and out. Interpoles and compensating windings sit on the stator to help commutation.

Why does a DC machine need a commutator?

A coil turning in a field always generates AC: the EMF reverses every half turn. The commutator reverses the coil's connection to the brushes at the instant its EMF reverses, so the brushes see one polarity: a mechanical rectifier. With one coil the output is bumpy; with many coils spread round the armature, the bumps overlap into nearly steady DC.

Slip rings vs commutator: how many coils smooth a DC generator's EMF: interactive loads as you scroll

What is the difference between lap and wave windings?

A lap winding connects each coil to the next one under the same pair of poles, giving as many parallel paths as poles (): high current, lower voltage. A wave winding travels round the whole armature before returning, giving always two paths (): higher voltage, lower current. For a simplex wave winding the commutator pitch must be a whole number.

What is the EMF equation of a DC machine?

Each conductor cuts flux per revolution, so its average EMF is . There are conductors in series in each parallel path, so the armature EMF is . For a given machine this is simply : EMF is proportional to flux and speed, the key to every DC generator and motor calculation.

How are DC machines classified?

By how the field is fed. Separately excited: field from its own supply. Self-excited: shunt (field across the armature, many turns of thin wire), series (field in series with the armature, few turns of thick wire) and compound (both; cumulative if they aid, differential if they oppose; long or short shunt). Permanent-magnet DC machines replace the field winding with magnets.

Predict, then check

You rewind a 4-pole DC generator from lap to wave, same conductors, same speed and flux. Its EMF:

Worked examples

EMF of a lap and a wave winding · 4 poles, Z = 500, Φ = 25 mWb, N = 1200 rpm
  1. Lap (A = 4):
  2. Wave (A = 2): same numerator over 60 × 2

Answer: 250 V lap, 500 V wave

Speed for a required EMF · 6-pole wave wound, Z = 300, Φ = 20 mWb, E = 240 V

Answer: 800 rpm

Can it be wave wound? · 4-pole machine with 21 commutator segments; and with 20
  1. Commutator pitch
  2. C = 21: (21 ± 1)/2 = 11 or 10, whole numbers
  3. C = 20: 21/2 or 19/2, not whole

Answer: 21 segments: yes (progressive Yc = 11 or retrogressive Yc = 10); 20 segments: no simplex wave winding

Chapter 3

DC generators: build-up, characteristics, armature reaction and parallel operation

Which syllabus covers thisAU EE3303 Unit IIVTU not in syllabusSPPU 203146 Units 3-4MU EEC303 Module 3KTU PCEET303 Module 1

How does a self-excited shunt generator build up its voltage?

Residual magnetism gives a few volts at no field current. That drives a small field current, which adds flux, which raises the voltage, and so on, until the open-circuit characteristic (OCC) meets the field-resistance line. It fails if there is no residual flux (flash the field from a battery), the field is connected backwards, the field resistance is above critical, or the speed is below critical.

Self-excited DC shunt generator: OCC, field-resistance line, critical resistance and voltage build-up: interactive loads as you scroll

What are critical field resistance and critical speed?

The critical field resistance is the slope of the OCC's straight initial part: with a steeper field line the two never meet beyond the residual voltage and the generator will not build up. Because the OCC scales with speed, critical resistance does too, . For a given field resistance, the critical speed is the speed at which that resistance becomes critical.

How does terminal voltage change with load?

A separately excited generator droops slightly: armature drop plus armature reaction. A shunt generator droops more, because the falling voltage also cuts its own field current; past a point it collapses. A series generator's voltage rises with load. A cumulatively compound generator can be flat-compounded (same voltage at no load and full load) or over-compounded to make up for line drop.

What is armature reaction, and how is commutation helped?

Armature current makes its own flux, at right angles to the main field. It distorts the field (cross-magnetising), shifts the neutral plane, and with saturation weakens it (demagnetising). During commutation each coil's current must reverse in milliseconds; its inductance resists, causing sparking. Interpoles inject a small opposing EMF in the commutating coil; compensating windings in the pole faces cancel armature reaction in large machines.

How do DC generators share load in parallel?

Each generator's current is set by how far its EMF is above the common bus voltage, divided by its armature resistance. Raise one machine's field and it takes more load. Shunt generators share stably because their voltage droops; compound generators need an equaliser bar joining their series fields, or one machine can take over the load and motor the other.

Predict, then check

A shunt generator builds up to 230 V at 1500 rpm. You run it at 1000 rpm with the same field resistance. It:

Worked examples

Generated EMF of a loaded shunt generator · 250 V, 10 kW load, field 125 Ω, Ra = 0.1 Ω, brush drop 2 V
  1. = 10,000/250 = 40 A; = 250/125 = 2 A; = 42 A

Answer: 256.2 V

Critical resistance and critical speed · OCC straight part at 1000 rpm: 100 V at 0.5 A; field resistance 250 Ω
  1. = 100/0.5 = 200 Ω at 1000 rpm
  2. At 800 rpm: = 200 × 0.8 = 160 Ω
  3. Critical speed for 250 Ω: 1000 × 250/200 = 1250 rpm

Answer: 200 Ω; it must run above 1250 rpm to build up with 250 Ω

Two generators in parallel · EMFs 250 V and 245 V, Ra = 0.1 Ω and 0.08 Ω, total load 300 A (field currents ignored)
  1. (250 − V)/0.1 + (245 − V)/0.08 = 300
  2. V = 233.89 V
  3. = 161.1 A, = 138.9 A

Answer: Bus 233.9 V; 161 A and 139 A

Chapter 4

DC motors: back EMF, characteristics, starting, speed control and braking

Which syllabus covers thisAU EE3303 Unit IIIVTU BEE401 Module 1SPPU 203146 Units 3-4MU EEC303 Module 3KTU PCEET303 Module 2

What is back EMF and why does it matter?

A spinning armature generates an EMF that opposes the supply: . It makes a DC motor self-regulating. Add load, the motor slows, falls, more current flows and torque rises to match. At standstill is zero, so the starting current would be , ten to twenty times rated: hence starters.

How do shunt, series and compound motors behave?

Shunt: almost constant flux, so speed drops only a few per cent from no load to full load; torque rises in step with current. Series: flux grows with current, so torque rises roughly as and speed falls steeply; huge starting torque for traction and cranes, but never start one unloaded, it races. Cumulative compound sits between them.

DC motor torque-speed: shunt, series and compound, and three ways to control speed: interactive loads as you scroll

How is the speed of a DC motor controlled?

From there are three handles. Armature voltage control (Ward-Leonard, now a chopper) gives smooth control below base speed at constant torque. Field weakening raises speed above base at constant power. Armature resistance control is simple but wastes power in the resistor. A series motor uses diverter, tapped-field or series-parallel control.

Why does a DC motor need a starter?

At start there is no back EMF, so only the armature resistance limits current. A three-point starter puts graded resistance in series with the armature and cuts it out step by step as the motor speeds up; a no-volt release drops it back to off if supply fails, and an overload release trips on excess current. A four-point starter keeps the hold-on coil off the field circuit, so field control does not trip it. Solid-state soft starters ramp the voltage instead.

How is a DC motor braked electrically?

Regenerative braking: the load drives the motor above no-load speed, exceeds and power returns to the supply, as in an EV going downhill. Dynamic (rheostatic) braking: disconnect the armature from the supply and close it onto a resistor, burning the kinetic energy as heat. Plugging: reverse the armature supply for a quick stop, with a resistor to limit the current.

Predict, then check

A shunt motor drives a constant-torque load. You weaken its field by 20%. The speed:

Worked examples

Speed at a higher load · 220 V shunt motor, Ra = 0.5 Ω, 1000 rpm at Ia = 20 A; load raises Ia to 40 A, flux constant
  1. = 220 − 10 = 210 V, = 220 − 20 = 200 V
  2. = 1000 × 200/210 = 952.4 rpm
  3. Torque at 20 A: = 40.1 N·m

Answer: 952 rpm

Starter resistance · Same motor; starting current limited to 40 A
  1. Without a starter: 220/0.5 = 440 A
  2. Total resistance 220/40 = 5.5 Ω, so external R = 5.0 Ω

Answer: 5.0 Ω in the first step

Series motor with double the torque · 220 V series motor, Ra + Rse = 0.6 Ω, 800 rpm at 30 A, flux ∝ current
  1. T ∝ I², so = 42.43 A
  2. = 202 V, = 194.54 V

Answer: 545 rpm

Field weakening at constant torque · The shunt motor above at 20 A and 1000 rpm; flux cut by 20%
  1. = 20/0.8 = 25 A
  2. = 220 − 25 × 0.5 = 207.5 V

Answer: 1235 rpm

Chapter 5

Losses, efficiency and testing of DC machines

Which syllabus covers thisAU EE3303 Unit IIIVTU BEE401 Module 1SPPU 203146 Unit 3MU EEC303 Module 3KTU PCEET303 Modules 1-2

What losses does a DC machine have?

Copper losses in the armature (), series and shunt fields, plus brush contact loss. Iron losses in the armature core (hysteresis and eddy currents). Mechanical losses: bearing friction and windage. In a shunt machine at constant speed the iron, mechanical and shunt-field losses barely change with load, so they are lumped as constant losses; armature copper loss is the variable loss.

When is a DC machine most efficient?

Efficiency is output over output plus losses. Constant losses dominate at light load, copper loss at heavy load. Differentiate and the peak falls where the variable copper loss equals the constant loss: . Designers place that point near the load the machine runs at most, usually 75–100% of rating.

DC machine efficiency vs load: constant losses, copper loss and the maximum-efficiency point: interactive loads as you scroll

What is Swinburne's test?

An indirect test: run the machine as a shunt motor on no load at rated voltage and speed. The input then covers only the constant losses plus a tiny armature copper loss. Knowing , you predict efficiency at any load, as motor or generator, without loading it. Cheap, but it misses the extra iron loss from armature reaction at full load and cannot be used on series motors.

What are Hopkinson's, field and retardation tests?

Hopkinson's (regenerative) test couples two identical machines: one motors, the other generates and feeds power back, so the supply covers only the losses while both run at full load. The field test does the same for two series motors on one shaft. The retardation (running-down) test cuts the supply and times the slowdown to measure rotational losses from the stored kinetic energy.

What is a brake test?

A direct test: load the motor with a belt or band brake on its pulley, read the two spring balances, and compute torque = (pull difference) × g × radius. Output = , input = . It measures real efficiency at real load, but the heat from the brake limits it to small motors, and all that power is wasted.

Predict, then check

A machine's constant losses are 550 W and Ra = 0.4 Ω. Its efficiency peaks at about:

Worked examples

Swinburne's test · 220 V shunt motor: no load 2.5 A, shunt field 220 Ω, Ra = 0.4 Ω; predict efficiency at 30 A line current
  1. No load: input 550 W, = 1.5 A; constant losses = 550 − 1.5² × 0.4 = 549.1 W
  2. Motor at 30 A: = 29 A, copper loss 336.4 W, η = (6600 − 336.4 − 549.1)/6600 = 86.58%
  3. Generator delivering 30 A: = 31 A, copper loss 384.4 W, η = 6600/(6600 + 933.5) = 87.61%

Answer: 86.6% as a motor, 87.6% as a generator; peak efficiency at = √(549.1/0.4) = 37.1 A

Hopkinson's test · 220 V; generator armature 60 A, supply to armatures 8 A, Ra = 0.05 Ω each; field currents: generator 2.5 A, motor 2 A
  1. Motor armature = 60 + 8 = 68 A; copper losses 231.2 W (motor), 180 W (generator)
  2. Stray losses per machine = (220 × 8 − 411.2)/2 = 674.4 W
  3. Generator: η = 13,200/(13,200 + 180 + 674.4 + 550) = 90.38%
  4. Motor: input 220 × 70 = 15,400 W, losses 1345.6 W, η = 91.26%

Answer: Generator 90.4%, motor 91.3%

Brake test · 220 V, 20 A input; net pull 15 kg on a 0.2 m radius pulley at 1200 rpm
  1. T = 15 × 9.81 × 0.2 = 29.43 N·m
  2. Output = 29.43 × 2π × 1200/60 = 3,698 W

Answer: η = 3,698/4400 = 84.1%

Chapter 6

Single-phase transformer: principle, equivalent circuit and phasor diagrams

Which syllabus covers thisAU EE3303 Unit IVVTU BEE304 Module 1SPPU 203146 Unit 1MU EEC402 Module 1KTU PCEET303 Module 3

How does a transformer work?

An alternating voltage on the primary drives an alternating flux round a laminated core. The same flux links the secondary and induces an EMF in it, statically, with no moving parts. EMF per turn is the same on both windings, so the voltages are in the ratio of turns and the currents in the inverse ratio. Core type has windings on the limbs; shell type has them on the central limb.

What happens on no load?

The primary draws a small no-load current, 2–5% of rated. Its magnetising component lags the voltage by 90° and sets up the flux; its working component is in phase and supplies core loss. So the no-load power factor is low, around 0.1–0.2. In the equivalent circuit these become a shunt resistance and reactance .

What is the equivalent circuit, and what does referring mean?

Each winding has resistance and leakage reactance (flux that links only that winding). Move the secondary's impedances to the primary by multiplying by , or the other way by dividing, and the transformer becomes one circuit: series and , with the shunt branch at the input. The approximate circuit moves the shunt branch to the terminals.

What does the phasor diagram on load show?

Start from terminal voltage and load current at the load's power factor angle. Add the drop parallel to and perpendicular to it: the result is the EMF . Lagging loads make bigger than ; a strong leading load can make rise above , so regulation goes negative.

Transformer on load: phasor diagram and voltage regulation at lagging, unity and leading power factor: interactive loads as you scroll

What are transformers rated in, and what types exist?

In kVA, not kW: copper loss depends on current and iron loss on voltage, whatever the load's power factor. Types: power and distribution transformers, instrument transformers (CT, PT), isolation transformers, welding transformers (high leakage reactance for a drooping characteristic), toroidal and wound-core transformers with low leakage and noise.

Predict, then check

A 50 Hz transformer is connected to a 60 Hz supply of the same voltage. Its peak core flux:

Worked examples

Turns from the EMF equation · 2300/230 V, 50 Hz, peak core flux 5 mWb
  1. = 2072

Answer: ≈ 2072, ≈ 207

Referring to the secondary · 10 kVA, 2300/230 V: R1 = 4 Ω, X1 = 8 Ω, R2 = 0.04 Ω, X2 = 0.08 Ω
  1. Turns ratio 10, so divide primary values by 100
  2. = 0.04 + 4/100 = 0.08 Ω; = 0.08 + 8/100 = 0.16 Ω
  3. Rated = 10,000/230 = 43.48 A

Answer: = 0.08 + j0.16 Ω

No-load current components · Same transformer, HV side: = 0.5 A at power factor 0.1
  1. = 0.5 × 0.1 = 0.05 A, = 0.5 × √(1 − 0.01) = 0.4975 A
  2. Core loss = 2300 × 0.05 = 115 W
  3. = 2300/0.05 = 46,000 Ω, = 2300/0.4975 = 4,623 Ω

Answer: Core loss 115 W; R0 = 46,000 Ω, X0 ≈ 4,623 Ω

Chapter 7

Transformer tests, voltage regulation and efficiency

Which syllabus covers thisAU EE3303 Unit IVVTU BEE304 Module 1SPPU 203146 Units 1-2MU EEC402 Module 1KTU PCEET303 Modules 3-4

What do the open-circuit and short-circuit tests give?

OC test: rated voltage on the LV side, HV open. Current is small, so the wattmeter reads core loss and the readings give and . SC test: LV shorted, a reduced voltage (5–10%) on the HV side drives rated current. Flux is tiny, so the wattmeter reads full-load copper loss and the readings give , . Together they predict regulation and efficiency at any load without loading.

What is voltage regulation?

The change in secondary voltage from no load to full load, as a fraction of a reference voltage (here the full-load terminal voltage). It depends on power factor: , plus for lagging and minus for leading. Distribution transformers aim for 2–5%; on-load tap changers correct the rest.

When is a transformer most efficient?

Efficiency = output/(output + core loss + copper loss). Core loss is constant; copper loss goes as load squared. The peak is where they are equal, at load fraction . Transformers reach 97–99.5%. Distribution transformers, lightly loaded much of the day, are designed with low core loss so the peak sits at 50–70% load.

Transformer efficiency against load, maximum efficiency and all-day efficiency: interactive loads as you scroll

What is all-day efficiency?

Distribution transformers are energised 24 hours but loaded only part of that time. All-day (energy) efficiency is output kWh over input kWh in a day: core loss counts for 24 hours, copper loss only for the loaded hours, weighted by load squared. It is the figure that matters for a distribution transformer, and why IS 1180 and BEE star ratings limit total losses at 50% load, not just at full load.

What are Sumpner's test and the polarity test?

Sumpner's (back-to-back) test connects two identical transformers so the primaries see rated voltage (core loss) and a small injected voltage circulates rated current round the secondaries (copper loss): both at once, for heat runs, using only the losses. The polarity test applies a low voltage and reads the voltage between primary and secondary terminals to find which ends are dot-marked, needed before paralleling.

Predict, then check

The same transformer feeds a leading-power-factor load of rated current. Its secondary voltage on load is:

Worked examples

Equivalent circuit from the SC test · 10 kVA, 2300/230 V; SC test on HV: 77.8 V, 4.35 A, 151.2 W
  1. = 151.2/4.348² = 8.00 Ω
  2. = 77.8/4.348 = 17.89 Ω
  3. = 16.0 Ω

Answer: R01 = 8 Ω, X01 = 16 Ω (0.08 Ω and 0.16 Ω referred to LV)

Regulation at 0.8 power factor · Same transformer at full load (43.48 A on LV), 0.8 lagging and 0.8 leading
  1. Lagging: 43.48 × (0.08 × 0.8 + 0.16 × 0.6)/230 = 3.02%
  2. Exact: = 236.98 V, so 3.04%
  3. Leading: 43.48 × (0.064 − 0.096)/230 = -0.60%

Answer: 3.0% lagging, -0.6% leading

Full-load and maximum efficiency · Same transformer: core loss 115 W, full-load copper loss 151.2 W, 0.8 pf
  1. Full load: 8000/(8000 + 115 + 151.2) = 96.78%
  2. Maximum at x = √(115/151.2) = 0.872
  3. η max = 6,976/(6,976 + 230) = 96.81%

Answer: 96.78% at full load; peak 96.81% at 87% load

All-day efficiency · 100 kVA distribution transformer, core loss 0.3 kW, full-load copper loss 1.2 kW; 6 h at 80 kW and 10 h at 40 kW (0.8 pf), 8 h no load
  1. Output = 6 × 80 + 10 × 40 = 880 kWh
  2. Copper loss = 6 × 1.2 × 1² + 10 × 1.2 × 0.5² = 10.2 kWh; core = 24 × 0.3 = 7.2 kWh
  3. η = 880/(880 + 17.4)

Answer: 98.06% all-day (against 98.16% at full load)

Chapter 8

Autotransformers, three-phase transformers, vector groups and parallel operation

Which syllabus covers thisAU EE3303 Unit VVTU BEE304 Module 2SPPU 203146 Units 1-2MU EEC402 Modules 2-3KTU PCEET303 Modules 3-4

Why is an autotransformer cheaper?

It has one winding with a tap: part of the power is conducted straight through and only the fraction is transformed, where . Copper needed is of a two-winding transformer's, so the saving is : large when the ratio is near 1. The catch: no isolation, and a broken winding puts full voltage on the load. Used for motor starting and grid interconnection.

How are three-phase transformers connected?

Star-star: cheap insulation, but third-harmonic problems without a neutral or tertiary. Delta-delta: no harmonic trouble, can run as open delta if one unit fails. Star-delta: step-down at the end of a transmission line. Delta-star: step-up at a power station and in distribution, giving a neutral for single-phase loads. Line and phase quantities differ by on the star side.

What do Yd1, Dy11 and the other vector groups mean?

Capital letter = HV connection, small letter = LV, number = LV phase shift on a clock face, 30° per hour, with the HV phasor at 12. Yy0 and Dd0: no shift. Yd1 and Dy1: LV lags 30°. Yd11 and Dy11: LV leads 30°, the common Indian distribution transformer (Dyn11). Only transformers with the same clock number can be paralleled.

Three-phase transformer vector groups on a clock: Yy0, Dd0, Yd1, Yd11, Dy1, Dy11 and parallel operation: interactive loads as you scroll

What conditions must transformers meet to run in parallel?

Essential: same polarity, same phase sequence and same vector group (phase shift), otherwise huge circulating current. Desirable: same voltage ratio (else circulating current even at no load), and per-unit impedances equal with the same X/R ratio, so each takes load in proportion to its rating. A transformer with lower percentage impedance takes more than its share.

What are the Scott connection, open delta, tap changers and tertiary windings?

Scott: two transformers, a centre-tapped main and a teaser with 86.6% turns, turn three-phase into two-phase for furnaces and traction. Open delta (V-V): two units supply 57.7% of a three-unit bank. Tap changers adjust turns; on-load ones switch under load. A delta tertiary winding traps third harmonics. Magnetising inrush at switch-on can reach 6–10 times rated current.

Predict, then check

A Dy11 and a Dy1 transformer of identical rating and ratio are connected in parallel. What happens?

Worked examples

Autotransformer saving · 10 kVA, 400 V to 320 V
  1. k = 320/400 = 0.8
  2. Transformed power = (1 − 0.8) × 10 = 2 kVA; conducted = 8 kVA

Answer: 80% copper saving over a two-winding transformer

Dy11 distribution transformer · 500 kVA, 11 kV / 433 V, delta HV, star LV
  1. HV line current = 500,000/(√3 × 11,000) = 26.24 A; delta phase current = 15.15 A
  2. LV line current = 500,000/(√3 × 433) = 666.7 A
  3. Turns per phase = 11,000/(433/√3) = 44.0

Answer: 26.2 A HV, 667 A LV, turns ratio 44 : 1

Load sharing in parallel · A: 500 kVA, 5% impedance; B: 250 kVA, 4%; same X/R; 600 kVA load
  1. Ohmic impedance ∝ %Z/S: A 0.010, B 0.016
  2. = 369.2 kVA, = 230.8 kVA

Answer: A 369 kVA (74% of rating), B 231 kVA (92%): B, with lower impedance, works harder

Scott connection and open delta · 415 V three-phase to 230 V two-phase; and three 100 kVA units, one removed
  1. Main ratio 415 : 230 = 1.804; teaser 0.866 × 415 : 230 = 1.563
  2. Open delta: √3 × 100 = 173.2 kVA

Answer: Teaser ratio 1.56; V-V bank carries 173 kVA, 57.7% of 300 kVA

Chapter 9

Three-phase induction motor: rotating field, construction and slip

Which syllabus covers thisAU EE3405 Unit IIIVTU BEE401 Module 2SPPU 203146 Unit 5MU EEC402 Module 4KTU PCEET402 Module 1

How do three-phase currents make a rotating field?

Three windings 120° apart in space carry currents 120° apart in time. Each makes a field that only pulsates along its own axis, but their sum has a constant magnitude, 1.5 times one phase's peak, and rotates at synchronous speed . Swap any two supply leads and it rotates the other way: that is how you reverse an induction motor.

Three-phase currents in three coils making a rotating magnetic field: interactive loads as you scroll

What are squirrel-cage and slip-ring rotors?

Both have a laminated stator with a three-phase winding. A squirrel-cage rotor has bars of aluminium or copper shorted by end rings: rugged, cheap, no brushes: most industrial motors are this type. A slip-ring (wound) rotor has a three-phase winding brought out to slip rings, so external resistance can be added for high starting torque and limited starting current, at the cost of brushes and maintenance.

What is slip, and why can't the rotor reach synchronous speed?

The rotor has no supply of its own: the field induces its currents, and only relative motion induces them. At synchronous speed nothing cuts the rotor bars, so there is no current and no torque. The rotor runs slightly slower; slip is typically 2–6% at full load. Rotor EMF and frequency are both proportional to slip.

How do rotor EMF, reactance and current change with slip?

At standstill the rotor is like a shorted transformer secondary: EMF , reactance at supply frequency. Running at slip , both scale by : EMF , reactance . So rotor current is huge at start (low power factor) and small and nearly in phase when running.

Predict, then check

A 4-pole motor on a 50 Hz supply runs at 1440 rpm. The frequency of the current in its rotor bars is:

Worked examples

Slip and rotor frequency · 4 poles, 50 Hz, 1440 rpm
  1. = 120 × 50/4 = 1500 rpm
  2. s = 60/1500 = 0.04
  3. = 0.04 × 50

Answer: s = 4%, rotor frequency 2 Hz

Rotor current at start and when running · Standstill rotor EMF 100 V/phase, R2 = 0.1 Ω, X2 = 0.5 Ω; running at s = 0.04
  1. Start: 100/|0.1 + j0.5| = 196.1 A
  2. Running: 4/|0.1 + j0.02| = 39.22 A, power factor 0.981

Answer: 196 A at start, 39.2 A running: five times less

Poles from the nameplate · A motor rated 960 rpm, 50 Hz
  1. Nearest synchronous speed above 960 is 1000 rpm
  2. P = 120 × 50/1000 = 6

Answer: 6 poles, slip 4%

Chapter 10

Induction motor: equivalent circuit, torque-slip curve, power flow and tests

Which syllabus covers thisAU EE3405 Unit IIIVTU BEE401 Modules 2-3SPPU 203146 Units 5-6MU EEC402 Module 4KTU PCEET402 Module 1

What is the induction motor's equivalent circuit?

It is a transformer whose secondary load is . Split that into (rotor copper loss) and (mechanical power). Add stator resistance and leakage reactance, the magnetising branch, and the rotor leakage reactance . The large air gap makes the magnetising current 25–40% of rated, far higher than in a transformer.

What does the torque-slip curve look like?

Near synchronous speed torque rises almost linearly with slip: the stable running region. It peaks at the pull-out (breakdown) torque, at slip , then falls towards standstill. Maximum torque does not depend on rotor resistance, only where it occurs does: add resistance to a slip-ring rotor and peak torque moves towards start. Torque goes as voltage squared.

Induction motor torque-slip curve: braking, motoring and generating, and what rotor resistance does: interactive loads as you scroll

How does power flow through an induction motor?

Stator input minus stator copper and iron loss crosses the air gap: . The rotor splits it in a fixed ratio: is rotor copper loss and becomes mechanical power, from which friction and windage are lost before the shaft. So a motor running at high slip is inherently inefficient: rotor efficiency can never exceed .

What are the motoring, generating and braking regions?

Between slip 0 and 1 the machine motors. Drive it above synchronous speed (negative slip) and the torque reverses: it generates, feeding power back, as in wind turbines and regenerative braking. Run it against its field (slip above 1, by reversing two leads while it spins) and it brakes: plugging, which also takes power from the supply.

How are the no-load and blocked-rotor tests and the circle diagram used?

No-load test: rated voltage, uncoupled; input covers core plus friction losses and gives the magnetising branch. Blocked-rotor test: rotor held, reduced voltage for rated current; gives and . From these two tests the circle diagram, the locus of stator current, predicts current, power factor, torque and efficiency graphically. Testing follows IS 325 (specification) and IS 4029 (test guide).

What are double-cage rotors, cogging and crawling?

A double-cage rotor has a high-resistance outer cage, dominant at start when rotor frequency is high and the inner cage's reactance large, and a low-resistance inner cage for running: high starting torque and good efficiency; deep bars do the same. Cogging is refusal to start when stator and rotor slot numbers lock; crawling is running stuck near one-seventh speed on the 7th space harmonic. Skewed rotor slots cure both.

Predict, then check

You double the rotor resistance of a slip-ring induction motor. Its maximum torque:

Worked examples

Power flow · 4-pole, 50 Hz motor: stator input 40 kW, stator losses 1 kW, slip 4%, friction and windage 0.5 kW
  1. = 39 kW
  2. Rotor copper loss = 0.04 × 39 = 1.56 kW; mechanical = 37.44 kW; shaft = 36.94 kW
  3. η = 36.94/40 = 92.35%
  4. Shaft torque = 36,940/(2π × 1440/60) = 245.0 N·m

Answer: 36.94 kW at 92.3%, 245 N·m

Starting, full-load and maximum torque · R2 = 0.1 Ω, X2 = 0.5 Ω per phase (stator impedance neglected), full-load slip 3%
  1. = 0.1/0.5 = 0.2
  2. = 0.3846
  3. = 0.2934

Answer: Maximum torque = 3.41 × full load; starting torque = 1.31 × full load

Rotor resistance for maximum starting torque · Same rotor
  1. Maximum torque at start needs : = 0.5 Ω

Answer: Add 0.4 Ω per phase (rotor side) through the slip rings

Blocked-rotor test · 415 V star motor; blocked rotor: 100 V (line), 20 A, 1400 W; stator R1 = 0.5 Ω; no load: 415 V, 6 A, 600 W
  1. = (100/√3)/20 = 2.887 Ω; = 1400/(3 × 400) = 1.167 Ω
  2. = 2.640 Ω; = 1.167 − 0.5 = 0.667 Ω
  3. No-load power factor = 600/(√3 × 415 × 6) = 0.139

Answer: R2' ≈ 0.67 Ω, X1 = X2' ≈ 1.32 Ω; no-load pf 0.14

Chapter 11

Starting, speed control and braking of induction motors; induction generators

Which syllabus covers thisAU EE3405 Units III-IVVTU BEE401 Modules 3-4SPPU 203146 Unit 6; 303143 Unit 4MU EEC402 Module 5KTU PCEET402 Modules 1-2

Why do induction motors need starters, and which kinds are there?

Direct-on-line, a cage motor draws 5–8 times full-load current, dipping the supply voltage for everyone. DOL is fine for small motors. A star-delta starter starts in star: one-third the line current and one-third the torque. An autotransformer starter at tap cuts both current and torque to . Slip-ring motors use rotor resistance, which raises torque while limiting current. Soft starters ramp the voltage with thyristors.

Induction motor starting (DOL, star-delta, autotransformer, rotor resistance) and V/f speed control: interactive loads as you scroll

How is an induction motor's speed controlled?

From : change the supply frequency, the poles, or the slip. Variable-frequency drives (V/f control) keep flux constant by varying voltage with frequency, with a small voltage boost at low speed to cover the stator resistance drop: the dominant method today. Pole-changing windings give two fixed speeds. Stator voltage control and rotor resistance control raise slip, cheap but lossy. Cascading two motors gives .

What is slip power recovery?

In rotor resistance control, slip power is burnt as heat. A slip-power recovery drive (static Kramer or Scherbius) instead rectifies the rotor's slip-frequency power and feeds it back to the mains through an inverter, so speed is controlled with little loss. The doubly-fed induction generator in wind turbines uses the same idea with a bidirectional converter.

How are induction motors braked?

Plugging: swap two supply leads; the field reverses and the rotor brakes hard, but currents are high and it must be disconnected at zero speed. Dynamic (DC injection) braking: disconnect AC and feed DC into the stator; the stationary field brakes the rotor, energy goes into rotor heat. Regenerative braking: drive the motor above synchronous speed and it returns power to the supply, as in cranes lowering a load.

How does an induction machine work as a generator?

Drive it above synchronous speed and slip goes negative: torque and power reverse, and the machine feeds active power to the grid. It still needs reactive power for its magnetising current: from the grid (line-excited) or from capacitors (self-excited, for isolated loads). Simple and rugged, so used in small hydro and older wind turbines.

Predict, then check

A cage motor started direct-on-line draws 6 times full-load current and gives 1.8 times full-load torque. Started star-delta, it gives:

Worked examples

Autotransformer tap · DOL: 6 × full-load current, 1.8 × full-load torque; line current must not exceed 2.5 × full load
  1. , so x = 0.645
  2. Starting torque = 0.4167 × 1.8 = 0.75 × full load

Answer: Tap at 64.5%, giving 0.75 × full-load torque

V/f control · 4-pole, 50 Hz, 400 V motor; 60 rpm slip at rated torque; wanted 900 rpm at rated torque
  1. Under V/f the slip speed at a given torque stays about the same
  2. = 900 + 60 = 960 rpm, so f = 960 × 4/120
  3. V = 400 × 32/50

Answer: 32 Hz at 256 V

Induction generator slip · 4-pole machine on 50 Hz driven at 1550 rpm
  1. s = (1500 − 1550)/1500

Answer: s = -0.0333: generating

Pole changing and cascade · 4/8-pole motor on 50 Hz; and a 4-pole motor cascaded with a 6-pole motor
  1. Pole changing: 120 × 50/4 and 120 × 50/8
  2. Cumulative cascade: 120 × 50/(4 + 6)

Answer: 1500 and 750 rpm; cascade 600 rpm

Chapter 12

Single-phase induction motors

Which syllabus covers thisAU EE3405 Unit VVTU BEE401 Module 4SPPU 303143 Unit 6MU EEC402 Module 6KTU PCEET402 Module 2

Why isn't a single-phase induction motor self-starting?

One winding makes a field that only pulsates. Double revolving field theory splits it into two fields of half the amplitude rotating in opposite directions. At standstill their torques are equal and opposite: no starting torque. Spin the rotor either way and the field in that direction wins, because the backward field sees slip and its rotor currents are almost purely reactive.

Single-phase induction motor: forward, backward and net torque by double revolving field theory, with capacitor start: interactive loads as you scroll

What is the single-phase motor's equivalent circuit?

The rotor is shown as two halves in series: a forward branch with and a backward branch with , each with half the magnetising and leakage reactance. Torque comes from the difference of power into the two halves. No-load and blocked-rotor tests give the parameters, as for the three-phase motor.

How do split-phase and capacitor motors start?

Add an auxiliary winding 90° away in space with a current shifted in time, and the two make a rotating (elliptical) field. Resistance split-phase: a high-resistance auxiliary, about 30° shift, moderate torque. Capacitor-start: a capacitor gives close to 90°, high starting torque; a centrifugal switch drops it out near 75% speed. Capacitor-start capacitor-run and permanent split capacitor keep a run capacitor in for quieter, more efficient running.

What is a shaded-pole motor?

A copper ring (shading coil) round part of each salient pole delays the flux in that part, so the flux sweeps from the unshaded to the shaded section: a weak moving field. No switch, no capacitor, very cheap, but low torque and efficiency of 10–30%. It runs table fans, hair dryers and small pumps. It always turns towards the shaded part.

Which single-phase motor goes where?

Ceiling fans: permanent split capacitor (and, increasingly, BLDC for energy saving). Refrigerator and air-conditioner compressors: capacitor-start capacitor-run for high starting torque against pressure. Washing machines, pumps, small workshop tools: capacitor-start. Exhaust fans and small blowers: shaded pole. Mixers and drills use universal motors, not induction motors, for high speed.

Predict, then check

A capacitor-start motor's centrifugal switch sticks open. You switch the motor on at standstill. It:

Worked examples

Forward and backward slip · 4-pole, 50 Hz motor running at 1440 rpm
  1. s = 0.04
  2. Backward slip = 2 − 0.04
  3. Rotor frequency of the backward field = 1.96 × 50

Answer: 1.96; backward rotor currents at 98 Hz

Torque from the equivalent circuit · 230 V, 50 Hz, 4-pole: R1 = 2, X1 = 3, R2' = 4, X2' = 2, Xm = 60 Ω; s = 0.05
  1. Forward half: = 14.06 + j19.11 Ω; backward half: = 0.959 + j0.999 Ω
  2. = 17.02 + j23.11 Ω, I = 8.02 A, power factor 0.593
  3. = 8.02² × (14.06 − 0.959)/157.1

Answer: 5.36 N·m at 8.02 A, input 1093 W

Capacitor for a 90° split · Main winding 4.5 + j3.7 Ω, auxiliary 9.5 + j3.5 Ω, 50 Hz
  1. Main current lags by atan(3.7/4.5) = 39.43°
  2. Auxiliary must lead by 50.57°: = 3.5 + 9.5 tan(50.57°) = 15.05 Ω
  3. C = 1/(2π × 50 × 15.05)

Answer: 211 µF

Chapter 13

Synchronous generator: construction, winding factors, EMF and armature reaction

Which syllabus covers thisAU EE3405 Unit IVTU BEE304 Module 3SPPU 303143 Unit 1MU EEC501 Module 1KTU PCEET402 Module 3

Why do alternators have a rotating field and stationary armature?

The armature carries the large high-voltage current; keeping it on the stator avoids passing it through slip rings and makes insulation and cooling easier. The DC field (small power) goes through slip rings or comes from a brushless exciter. Salient-pole rotors (many poles, large diameter) suit slow hydro turbines; smooth cylindrical rotors (2 or 4 poles) suit 3000 or 1500 rpm steam and gas turbines.

What are the pitch and distribution factors?

A short-pitched coil spans less than a pole pitch, so its two sides' EMFs are not quite in phase: . A distributed winding spreads a phase over several slots, adding phasors that are slightly out of step: . Both shave a few per cent off the fundamental but cut harmonics much harder, giving a cleaner sine wave.

Winding factors: short-pitched and distributed coils, and the harmonics they cut: interactive loads as you scroll

What is the EMF equation of an alternator?

Each turn links a flux alternating at frequency , so a full-pitched concentrated phase winding gives RMS. Multiply by the winding factor for the real distributed, short-pitched winding. Line voltage is times phase for a star connection.

How does armature reaction depend on power factor?

Armature current makes its own rotating field. At unity power factor it is at right angles to the main field: cross-magnetising, distorting the field. At zero power factor lagging it opposes the main field: demagnetising, so a lagging load needs more excitation. At zero power factor leading it aids the field: magnetising, so voltage rises. The synchronous reactance models this plus leakage.

Where do harmonics in an alternator come from, and how are they removed?

From a non-sinusoidal field distribution, slotting and saturation. Short pitching by one-fifth of a pole pitch kills the 5th harmonic; 5/6 pitch cuts both 5th and 7th to about a quarter. Distribution reduces the rest. Star connection blocks third harmonics from the line voltage. Skewing the slots reduces slot harmonics.

Predict, then check

A winding is short-pitched by 30° (5/6 pitch). Compared with full pitch, its 5th-harmonic EMF is:

Worked examples

Winding factor · Three-phase, 4 poles, 36 slots, coil span 8 slots
  1. Slots per pole per phase q = 36/(4 × 3) = 3; slot angle γ = 180° × 4/36 = 20°
  2. Full pitch is 9 slots, so short by one slot: α = 20°
  3. = 0.9848; = 0.9598

Answer: = 0.9452

Alternator EMF · Same winding, 10 conductors per slot (double layer), Φ = 50 mWb, 50 Hz, star
  1. Conductors per phase = 36 × 10/3 = 120, so = 60
  2. = 4.44 × 50 × 0.05 × 60 × 0.9452 = 629.5 V

Answer: 630 V per phase, 1,090 V line

Harmonic factors · 5/6 pitch (α = 30°), q = 3
  1. = 0.259; = 0.259
  2. = 0.218

Answer: 5th harmonic winding factor = 0.056, against 0.927 for the fundamental

Poles of a hydro generator · 50 Hz, turbine speed 300 rpm
  1. P = 120 × 50/300

Answer: 20 poles (a steam turbo-alternator at 3000 rpm has 2)

Chapter 14

Alternator voltage regulation: EMF, MMF, ZPF and ASA methods

Which syllabus covers thisAU EE3405 Unit IVTU BEE304 Module 3SPPU 303143 Unit 2MU EEC501 Module 2KTU PCEET402 Module 3

What does the alternator's phasor diagram show?

Per phase, the excitation EMF is the terminal voltage plus the drops across armature resistance and synchronous reactance: . The angle between and is the load (power) angle . Lagging loads need well above . Leading loads can need below , so removing the load makes the voltage fall: negative regulation.

Cylindrical-rotor alternator: phasor diagram and voltage regulation by the synchronous impedance method: interactive loads as you scroll

What are the EMF (synchronous impedance) and MMF methods?

Both use the open-circuit and short-circuit tests. EMF method: = OC voltage / SC current at the same field current, then the phasor equation; it treats the saturated machine as unsaturated, so it overestimates regulation (pessimistic). MMF method: adds field ampere-turns instead of voltages, treating everything as armature reaction; it underestimates (optimistic).

What are the ZPF (Potier) and ASA methods?

The zero power factor test loads the machine on a pure inductive load at rated current; with the OCC it gives the Potier triangle, which separates leakage reactance from armature reaction. That is the most accurate method. The ASA (American Standards Association) method corrects the MMF method for saturation using the OCC and the air-gap line, close to Potier's result with less testing.

What is the short-circuit ratio?

Field current for rated voltage on open circuit divided by field current for rated current on short circuit. It is roughly in per unit. A high SCR (about 1.0–1.5 for salient-pole hydro generators) means low synchronous reactance: better regulation and stability, but a bigger, costlier machine. Turbo-alternators sit around 0.5–0.7.

Predict, then check

Measured on the same alternator, which method gives the highest regulation?

Worked examples

Regulation by the EMF method · 3-phase star, 11 kV, 5 MVA, Ra = 0.4 Ω, Xs = 8 Ω per phase; full load at 0.8 lagging
  1. = 6,351 V, = 5 × 10⁶/(√3 × 11,000) = 262.4 A
  2. = 7,862 V at δ = 11.9°
  3. Regulation = (7,862 − 6351)/6351

Answer: 23.8% (line EMF 13.62 kV)

Unity and leading power factor · Same machine, full load
  1. Unity: E = 6,789 V, regulation 6.9%
  2. 0.8 leading: E = 5,461 V, regulation -14.0%

Answer: 6.9% at unity, -14.0% at 0.8 leading

Synchronous impedance from the tests · At the field current that drives rated current (262.4 A) on short circuit, the OC line voltage is 3641 V; Ra = 0.4 Ω
  1. = (3641/√3)/262.4 = 8.01 Ω

Answer: Xs ≈ 8.0 Ω

Short-circuit ratio · Field current for rated OC voltage 100 A; for rated SC current 80 A
  1. SCR = 100/80

Answer: 1.25; unsaturated Xs ≈ 0.8 pu

Chapter 15

Salient-pole machines, power-angle curves and parallel operation of alternators

Which syllabus covers thisAU EE3405 Unit IVTU BEE304 Module 4SPPU 303143 Units 1-2MU EEC501 Modules 3-4KTU PCEET402 Modules 3-4

What is Blondel's two-reaction theory?

In a salient-pole machine the air gap is short along the pole axis (direct axis) and long between poles (quadrature axis), so the same armature MMF makes more flux on the d-axis. Split the armature current into and and give each its own reactance, . The slip test (rotor driven just off synchronous speed, field open) measures both.

What is the power-angle curve?

Power delivered to an infinite bus is for a cylindrical rotor, maximum at 90°. A salient-pole machine adds reluctance power , which exists even with no field current, so its peak comes before 90°. The slope is the synchronising power: the restoring force that keeps the machine in step.

Power-angle curves: excitation power, reluctance power and the salient-pole peak: interactive loads as you scroll

How is an alternator synchronised to the grid?

Four conditions: equal voltage, equal frequency, same phase sequence and in phase at the moment of closing. Dark-lamp method: lamps across the breaker go dark together when in phase. Two-bright-one-dark method also shows whether the machine is fast or slow. A synchroscope's pointer rotates at the slip frequency; close the breaker as it passes 12 o'clock while turning slowly. Modern plants use automatic synchronisers.

What happens when you change the input or the excitation on an infinite bus?

The bus fixes voltage and frequency. Open the turbine valve and the rotor advances, grows and the machine delivers more active power; the frequency does not change. Raise the field current and active power stays the same while the machine supplies more lagging reactive power (over-excited); lower it and it absorbs reactive power. Between two machines, load sharing follows their governor droops.

What limits a generator's capability curve?

Plotted on P-Q axes: stator heating limits the MVA (a circle), rotor heating limits field current and so lagging reactive power, the turbine limits active power, and steady-state stability and stator end-core heating limit leading (under-excited) operation. Operators keep the machine inside this D-shaped area; hunting, oscillation of after a disturbance, is damped by damper bars in the pole faces.

Predict, then check

A salient-pole synchronous motor loses its field supply while lightly loaded. It:

Worked examples

Two-reaction phasors · Salient pole, Xd = 1.0 pu, Xq = 0.6 pu, Ra = 0; full load 1 pu at 0.8 lagging, V = 1 pu
  1. = 1.2/0.8, ψ = 56.31°
  2. δ = ψ − φ = 56.31 − 36.87 = 19.44°
  3. = 0.8321; = 1.7750 pu

Answer: E = 1.775 pu, δ = 19.4°, regulation 78%

Check with the power-angle equation · Same machine
  1. Excitation power = 1.775 × sin 19.44° = 0.5908 pu
  2. Reluctance power = 0.5 × (1/0.6 − 1) × sin 38.88° = 0.2092 pu

Answer: Total 0.800 pu = 1 × 0.8 ✓; reluctance supplies 26%

Synchronising power · Cylindrical rotor: E = 1.5 pu, V = 1, Xs = 1.2 pu, delivering 0.8 pu
  1. sin δ = 0.8 × 1.2/1.5, δ = 39.79°
  2. = 1.5/1.2 = 1.25 pu
  3. = 0.9605 pu per electrical radian

Answer: δ = 39.8°, synchronising power 0.960 pu/rad, margin to pull-out 0.45 pu

Lamps while synchronising · Incoming machine at 50.2 Hz, bus at 50 Hz
  1. Lamps brighten and darken at the slip frequency, 0.2 Hz

Answer: One dark period every 5 s: slow the machine down and close at the middle of a dark period

Chapter 16

Synchronous motor: V-curves, power factor control, hunting and starting

Which syllabus covers thisAU EE3405 Unit IIVTU BEE401 Module 5SPPU 303143 Unit 3MU EEC501 Module 5KTU PCEET402 Module 4

How does a synchronous motor work, and why isn't it self-starting?

The stator's rotating field locks onto the DC-excited rotor poles and drags them round at exactly synchronous speed, at any load up to pull-out. At standstill the stator field sweeps past the poles at synchronous speed and the torque on them alternates too fast for the rotor to follow: zero average. So it starts as an induction motor on its damper (amortisseur) bars, by a pony motor, or by a variable-frequency drive, and the field is switched in near synchronous speed.

What are V-curves and inverted-V curves?

At constant load, plot armature current against field current: a V, with its minimum at unity power factor. Under-excited (left of the minimum) the motor draws lagging current; over-excited it draws leading current. Plot power factor instead and you get an inverted V peaking at 1. Higher loads shift the curves up and to the right.

Synchronous motor V-curves and inverted-V power-factor curves: interactive loads as you scroll

What is a synchronous condenser?

An over-excited synchronous motor running with no mechanical load. It draws almost pure leading current, so it behaves like a capacitor bank whose kvar can be adjusted smoothly by the field current. It is used for power factor correction and voltage support on transmission systems, and is back in favour to add inertia and fault current to grids with lots of solar and wind.

What is hunting, and how do damper windings stop it?

A sudden change of load makes the rotor overshoot its new load angle and oscillate about it, like a mass on a spring (the synchronising power is the spring). If the oscillation grows the motor can pull out of step. Copper damper bars in the pole faces carry induced currents only when the rotor slips relative to the field, so they damp the swing; they double as the starting cage.

Where are synchronous motors used?

Where constant speed or power factor correction matters: large compressors, ball mills, rolling mills and pumps of hundreds of kW to MW, where running at leading power factor saves the plant's reactive power bill. Small versions run clocks and timers. The permanent-magnet synchronous motor in EVs is the same machine with magnets instead of a field winding, started and controlled by an inverter.

Predict, then check

A synchronous motor runs at unity power factor. You increase its field current, load unchanged. The armature current:

Worked examples

Current and power factor from excitation · V = 1 pu, Xs = 1 pu, Ra = 0; motor input 0.5 pu, E = 1.5 pu
  1. sin δ = P Xs/(EV) = 0.5/1.5, δ = 19.47°
  2. : |I| = 0.6493 pu at 39.6° (leading)

Answer: I = 0.649 pu, power factor 0.770 leading

Minimum excitation · Same motor at 0.5 pu load
  1. Pull-out at δ = 90°:

Answer: E must stay above 0.5 pu

Sizing a synchronous condenser · Plant load 500 kW at 0.7 lagging, to be raised to 0.95 lagging
  1. Now: Q = 500 tan(acos 0.7) = 510.1 kvar
  2. Target: Q = 500 tan(acos 0.95) = 164.3 kvar

Answer: 346 kvar leading (losses ignored)

A synchronous motor improving plant power factor · Factory 400 kW at 0.8 lagging; add a 150 kW synchronous motor at 0.8 leading
  1. Factory Q = 300 kvar lagging; motor Q = 150 tan(36.87°) = 112.5 kvar leading
  2. Total 550 kW, 187.5 kvar

Answer: Power factor 0.947 lagging (from 0.8)

Chapter 17

Special machines: BLDC, PMSM, stepper, SRM, universal and servo motors, dq theory

Which syllabus covers thisAU EE3405 Unit VVTU BEE401 Module 5SPPU 303143 Units 4-5MU EEC501 Module 6KTU not in syllabus

How does a BLDC motor commutate without brushes?

Magnets are on the rotor, windings on the stator, and an inverter does the commutator's job. Three Hall sensors 120° apart tell the controller which 60° sector the rotor is in; it energises the two phases that give maximum torque and switches every 60° electrical: six-step (trapezoidal) commutation. No brushes to wear, high efficiency, so ceiling fans, drones, e-bikes and two-wheeler hub motors use them.

BLDC motor six-step commutation from three Hall sensors: interactive loads as you scroll

What is a PMSM, and why use dq axes?

A permanent-magnet synchronous motor has sinusoidal back-EMF and is fed sinusoidal currents, smoother than a BLDC; most EV traction motors are interior PMSMs. Park's transformation views the three-phase currents from the rotor, turning them into two DC quantities: along the magnet axis and across it. Torque depends on (plus reluctance torque in interior magnets), so field-oriented control regulates them like a DC motor.

How does a stepper motor move in steps?

Each pulse energises the next phase and the rotor jumps one step to line up with it, so position follows the pulse count with no feedback. Variable-reluctance steppers use a toothed iron rotor, permanent-magnet ones a magnet rotor, and hybrids both, typically 200 steps per revolution (1.8°). Half-stepping and microstepping divide the step further. Used in 3D printers, CNC and cameras.

Stepper motor drive sequences: wave, full step and half step: interactive loads as you scroll

What are switched reluctance and universal motors?

A switched reluctance motor has salient poles on both stator and rotor and no magnets or rotor winding; energising stator poles in turn pulls the nearest rotor poles round. Rugged and cheap, but noisy with torque ripple. A universal motor is a series DC motor with a laminated core that runs on AC or DC; torque goes as current squared so it keeps one direction. High speed: mixers, drills, vacuum cleaners.

What are AC servo motors, linear induction motors and AC series motors?

A two-phase AC servo motor has a high-resistance rotor so its torque-speed line falls steadily and it stops when the control winding is off; modern servos are PMSMs with encoders. A linear induction motor is an induction motor unrolled flat: the field travels at and drags a conducting plate, as in Maglev and some metros. AC series motors need compensating windings and laminations to limit reactance and sparking.

Predict, then check

A 4-pole-pair BLDC motor spins at 3000 rpm. How many times per second does its controller commutate?

Worked examples

Stepper motor · Hybrid stepper, 200 steps per revolution, driven at 1000 pulses per second
  1. Step angle = 360/200
  2. Speed = 1000 × 1.8/360 rev/s

Answer: 1.8° per step, 300 rpm; 90° needs 50 pulses

BLDC commutation rate · 4 pole pairs, 3000 rpm
  1. = 3000 × 4/60 = 200 Hz
  2. Six steps per electrical cycle

Answer: 1200 commutations per second

PMSM torque · Surface PMSM, 4 pole pairs, magnet flux linkage 0.1 Wb, iq = 100 A, id = 0

Answer: 60 N·m

Linear induction motor · Pole pitch 0.25 m, 50 Hz
  1. = 2 × 0.25 × 50

Answer: 25 m/s (90 km/h) synchronous speed

Chapter 18

Generators for wind and solar power

Which syllabus covers thisAU not in syllabusVTU BEE304 Module 5; BEE401 Module 3 (DFIG)SPPU not in syllabusMU not in syllabusKTU not in syllabus

How much power can a wind turbine take from the wind?

The wind's power through the rotor's swept area is : double the wind speed and the power rises eightfold. No rotor can extract all of it, or the air would stop; the Betz limit is 16/27, 59.3%. Modern turbines reach a power coefficient of about 0.45–0.5. Horizontal-axis turbines dominate; vertical-axis ones accept wind from any direction but are less efficient.

Which generators do wind turbines use?

Fixed-speed turbines used squirrel-cage induction generators straight on the grid. Most multi-megawatt turbines use the doubly-fed induction generator: stator on the grid, rotor fed through a converter rated about 30% of the power, giving variable speed. Direct-drive turbines use permanent-magnet synchronous generators with a full-power converter and no gearbox.

How does a solar cell generate power?

Light frees electron-hole pairs at a silicon p-n junction and the junction field drives them round an external circuit. A cell gives about 0.5–0.6 V; 60 or 72 are wired in series to make a module. Current is proportional to sunlight, voltage falls with temperature, and power peaks at one point on the I-V curve, which the inverter's maximum power point tracker holds.

Solar module I-V and P-V curves with a perturb-and-observe tracker hunting the maximum power point: interactive loads as you scroll

What makes up a solar PV system, and what are the pros and cons?

Modules in series strings, a DC-AC inverter with MPPT, protection and metering; off-grid systems add batteries and a charge controller. Advantages: no fuel, no moving parts, modular, low running cost. Disadvantages: output only in daylight and falls with clouds, 18–22% module efficiency, land or roof area, and storage cost for night-time supply.

Predict, then check

The wind speed at a turbine rises from 6 m/s to 9 m/s. The power available in the wind rises by a factor of about:

Worked examples

Turbine output · Rotor diameter 80 m, wind 10 m/s, air 1.225 kg/m³, Cp = 0.45
  1. A = π × 40² = 5,027 m²
  2. P = 0.5 × 1.225 × 5,027 × 10³ × 0.45

Answer: 1,385 kW

DFIG power split · Stator delivers 2 MW at slip −0.2 (1800 rpm, 4-pole, 50 Hz); losses ignored
  1. Rotor power ≈ |s| × stator power = 0.2 × 2 MW, also delivered to the grid through the converter

Answer: 2.4 MW total; the converter handles only 0.4 MW

PV string · Modules with Vmp = 30 V and Imp = 8.5 A; 10 in series
  1. Module: 30 × 8.5 = 255 W
  2. String: 300 V, 8.5 A

Answer: 2.55 kW at 300 V

Keep going

Recommended reading

  • Electric Machines, I. J. Nagrath and D. P. Kothari
  • Electric Machinery, P. S. Bimbhra
  • Electric Machinery, A. E. Fitzgerald, C. Kingsley and S. D. Umans
  • Electrical Machinery, S. K. Bhattacharya
  • Principles of Electrical Machines, V. K. Mehta and R. Mehta
  • Electric Machines, Ashfaq Husain
  • Performance and Design of AC Machines, M. G. Say
  • Electric Machinery Fundamentals, S. J. Chapman

How this book was made

Chapters follow the official syllabi listed above. Every interactive's formulas and every worked-example number were checked by script. Explanations, animations and examples are original to Skill-Lync. Topics informed by MIT OpenCourseWare 6.685 (Electric Machines), CC BY-NC-SA. All explanations, animations and examples are original to Skill-Lync; MIT does not endorse this page.

From the exam to a core job

Talk to a counsellor.

Ask how motor and drives engineers use electrical machines on real projects, and what the Electric Motor Design using MATLAB and ANSYS Maxwell covers.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.