GATE Instrumentation (IN): Communication and Optical Instrumentation (AM, FM, PCM and TDM, photodiodes, LEDs and lasers, fibre optics, interferometers and spectrophotometry), previous-year questions solved
Every communication and optical instrumentation question from the last five GATE Instrumentation Engineering papers, solved: amplitude and frequency modulation, chopper amplifiers and synchronous demodulation, pulse code modulation and time-division multiplexing, LED and photodiode bias, laser diodes, optical fibres and fibre Bragg gratings, interferometers and absorption spectroscopy. Each answer matches the official key and was recomputed by code from a model with the values printed in the paper.
Questions from official GATE IN papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 19 Nov 2026 · 16 questions
AM wave s(t) = Ac[1 + m(t)] cos(2 pi fc t): which message does an envelope detector recover completely?
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- An envelope detector follows the outline of the peaks of the carrier. For the outline is , because an envelope can never be negative.
- The message comes back as only if at every instant, that is, if . This is the condition , a modulation index of at most 100%.
- (A) swings between and . So stays between and , never negative. The envelope is a faithful copy of the message.
- (B) goes down to , so reaches . (C) and (D) have amplitude 2 and reach for . Each is overmodulated: the carrier phase reverses and the envelope gets folded back, so the detector output is a distorted, rectified message.
- Only (A) keeps non-negative. The answer is (A).
Trap: thinking only about the frequency . That condition lets the detector follow the envelope; it does not stop overmodulation. We built the modulated wave for each message and ran a numerical envelope detector on it (rectify, average over one carrier cycle, scale by ). The worst error against the true message was 0.002 for (A), but 1.00 for (B), 1.98 for (C) and 1.98 for (D), where the message amplitude was 1.5, 2 and 2.
Envelope detection is how simple AM radio receivers, and the diode detector in many RF test probes, recover the audio or the envelope of a signal. Transmitters hold the modulation index below 100% for exactly this reason, and the same limit shows up in carrier-based sensor read-outs such as LVDT and strain-gauge amplifiers.
Ultrasonic vibration sensor, 500 Hz/V, f1 = 40 kHz, f2 = 1 kHz, 0.5 V: modulation index and deviation?
Assuming the frequency sensitivity factor as 500 Hz/volt, kHz, kHz, the modulation index () and the frequency deviation in , respectively, are
- (A)0.25 and Hz
- (B)0.5 and Hz
- (C)1 and Hz
- (D)0.75 and Hz
Answer: (A) Official key: A
- The received wave is frequency modulated by the vibration. Its instantaneous frequency is , with the frequency sensitivity .
- The frequency deviation is the largest swing of from . The peak of is , so . That is about the 40 kHz carrier.
- The modulation index is the deviation divided by the message frequency: .
- Check from the phase. The phase of is , and has peak . So the peak phase swing is rad, the same . The integral of a sine is a negative cosine, so the sign differs from the printed , but the question asks for sizes only.
- Answer: (A) 0.25 and Hz.
Trap: using 1 V instead of the 0.5 V amplitude gives and 500 Hz, option (B). Also, is divided by the message frequency (1 kHz), not the carrier (40 kHz). Because is well below 1 this is narrowband FM: the spectrum is the carrier plus one pair of sidebands. Carson's rule gives a bandwidth of about . We built in the time domain, differentiated its phase to get the deviation (250.0 Hz) and index (0.250), and checked the carrier and sideband lines against the Bessel functions: , . Only option (A) matched.
Ultrasonic and laser Doppler vibrometers, and flow and level meters that use a moving reflector, return a wave whose phase or frequency carries the motion, so the signal is demodulated as FM. Choosing the demodulator bandwidth with Carson's rule keeps the vibration spectrum without letting in extra noise.
Chopper amplifier, A = 100, signal to 50 Hz, offset to 10 Hz, low-pass at pi/T: s(t) frequency?
- (A)The minimum frequency of required is 100 Hz and gets attenuated by the system
- (B)The minimum frequency of required is 100 Hz and also gets amplified by the system by a factor
- (C)The minimum frequency of required is 80 Hz and gets attenuated by the system
- (D)The minimum frequency of required is 80 Hz and also gets amplified by the system by a factor
Answer: (A) Official key: A
- The first multiplier is a modulator: it moves to the square wave's odd harmonics. The amplifier adds (offset and low-frequency noise) after the modulator. The second multiplier is the demodulator.
- Because , . So the signal before the filter is .
- The wanted signal is back at baseband, amplified by , with no distortion. The offset is now multiplied by , so it has moved up to odd harmonics of the chopping frequency, Hz, Hz and so on.
- Let be the period of , so . The filter passes , that is frequencies up to .
- To pass the 50 Hz signal, Hz, so Hz. At 100 Hz the filter edge is 50 Hz and the nearest offset line is at Hz, well above it, so the offset is attenuated. At 80 Hz the edge is 40 Hz and the biomedical signal itself would be cut, so 80 Hz fails.
- Answer: (A). The factor is the size of the first offset sideband before filtering; it would reach the output only if the filter passed it.
Trap: reading as the chopping frequency itself. Reading the filter edge as the chopping frequency (not half of it) would suggest that 50 Hz chopping is enough, but then the offset lines at 40 and 60 Hz would also pass. Another trap is thinking the chopper amplifies the offset because the amplifier sits between two multipliers; the offset enters after the first multiplier, so only the second one chops it. We checked the identity on random values, then built the exact odd-harmonic lines of the chopped offset and tested every chopping frequency from 1 Hz to 400 Hz against an ideal low-pass filter at : the minimum frequency that keeps the 50 Hz signal and rejects every offset line is 100 Hz. At 80 Hz the signal gain is 0; at 100 Hz the signal gain is 100 and the offset gain is 0.
Chopper-stabilised and zero-drift amplifiers use this scheme to remove input offset and 1/f noise in thermocouple, strain-gauge, ECG and EEG front ends. The chopping frequency is set well above the signal band so the filter can separate the two.
AM voltage across a 1 ohm load, efficiency 60% and carrier power 50 W: value of L
- (A)8.66
- (B)1.22
- (C)0.81
- (D)17.32
Answer: (A) Official key: A
- Read the three terms. The middle frequency is : the carrier, amplitude . The other two are at and , which are the lower and upper sidebands, each of amplitude .
- Carrier power in : , so .
- Each sideband carries , so the total sideband power is (in watts, for ).
- Efficiency is the fraction of total power that sits in the sidebands: .
- Solve: , so . Option (A).
- Check with the modulation index: , and . An index above 1 means the envelope would over-modulate, but the question only asks for the power split.
Trap: defining efficiency as gives , which is not an option. We built the three-tone signal, found its carrier and sideband power by a Fourier sum over one period, and tested every option: only gives 60% efficiency with a 50 W carrier.
Broadcast AM transmitters waste most of their power in the carrier, which carries no information, so efficiency and carrier power are quoted to size the power amplifier and the electricity bill. The same sideband bookkeeping tells you how much of a modulated sensor or telemetry signal is actually data.
24 voice signals time-division multiplexed, 12 kHz sampling, 8-bit words: bit duration in microseconds?
Answer: Official key: 0.42 to 0.44
- Every channel is sampled times a second. So one frame, which carries one sample from each of the 24 channels, repeats every .
- Each sample is an 8-bit word, so a frame holds bits.
- These 192 bits must fit into one frame period. The bit rate is .
- Bit duration: .
Trap: confusing the bit time with the slot time. One channel's 8-bit word occupies , not . Real telephone multiplexers also add a framing bit: the T1 format uses 193 bits per frame, which gives , still inside the official range. The question says nothing about framing bits, so 192 is the intended count.
Digital telephone trunks (T1 at 1.544 Mbit/s and E1 at 2.048 Mbit/s) work exactly this way: 8000 samples per second per voice channel, interleaved in time slots. The same time-division idea lets one data link or one fieldbus carry readings from many sensors in turn.
PCM of an analog speech signal, 200 Hz to 2400 Hz, sampled at 6 kHz with 512 levels: bit rate
- (A)16
- (B)48
- (C)19.2
- (D)54
Answer: (D) Official key: D
- Pulse code modulation turns each sample into a binary word. With quantisation levels, each word needs bits.
- bits per sample.
- The question gives the sampling rate directly: . (The Nyquist rate for a 2400 Hz signal would be 4.8 kHz, but the signal is actually sampled faster, and the bit rate follows the real sampling rate.)
- Bit rate , which is . Option (D).
Trap: using the Nyquist rate gives 43.2 kbps, which is not an option; using 8 bits per sample gives 48 kbps (option B). We computed the rate for each option from the sampling rate and the word length; only 54 kbps matches.
Digital telephone lines carry speech at 8 kHz sampling and 8 bits per sample, 64 kbit/s per channel, and these numbers fix how many voice channels fit on a link. Instrument and sensor telemetry links are sized the same way: samples per second times bits per sample gives the minimum data rate the channel must carry.
Photodiode with a band gap of 1.42 eV: cut-off wavelength in nanometres?
Answer: Official key: 870.0 to 880.0
- A photodiode responds only if a photon has enough energy to lift an electron across the band gap: . The longest wavelength that still works is the cut-off: .
- Convert the gap to joules: .
- .
- , in the near infrared.
- Shortcut: . This matches gallium arsenide, whose band edge is near 870 nm.
Trap: forgetting to convert electronvolts to joules, or mixing micrometres and nanometres. Photons with a longer wavelength than do not generate carriers, so the detector goes blind above this wavelength. With exact CODATA constants the same calculation gives ; both values lie inside the official range.
The band gap sets which light a detector can see: silicon stops near 1100 nm, gallium arsenide near 870 nm, and InGaAs is used for the 1310 and 1550 nm telecom bands. Engineers pick the photodiode material from this cut-off before anything else, for optical sensors, fibre links and spectrometers.
Laser echo from a car comes back after 100 ns, then 90 ns a tenth of a second later: speed and direction?
- (A)54 kmph, moving towards the transceiver
- (B)108 kmph, moving towards the transceiver
- (C)54 kmph, moving away from the transceiver
- (D)108 kmph, moving away from the transceiver
Answer: (A) Official key: A
- The pulse travels to the car and back, so the one-way distance is half of . First pulse: .
- Second pulse: .
- The echo came back sooner, so the car is nearer: it moved towards the transceiver.
- The pulses were emitted apart. The reflection instants differ by , which is to nine digits, so .
- Convert: , moving towards the transceiver. The answer is (A).
Trap: forgetting that the light covers the distance twice. Using gives 108 km/h, option (B). The direction also needs care: a shorter echo time means the target is closer. We computed both ranges and the speed between the two reflection instants: 54.000 km/h towards.
Pulsed time-of-flight is how laser rangefinders, LiDAR sensors, police speed guns and level meters measure distance, and two ranges a known time apart give velocity. Nanosecond timing is needed because light covers 15 cm in 1 ns of round trip, so timing electronics set the range resolution.
An LED emits light when it is ___ biased; a photodiode is most sensitive when ___ biased
- (A)forward, forward
- (B)forward, reverse
- (C)reverse, reverse
- (D)reverse, forward
Answer: (B) Official key: B
- LED: a forward bias pushes electrons and holes across the junction, where they meet and recombine. In a direct-gap material each recombination can release a photon. A reverse-biased LED carries almost no current, so there is nothing to recombine and no light.
- Photodiode: it works in the opposite direction, turning absorbed photons into current. Light only produces useful, collectable carriers inside the depletion region, where the electric field sweeps electrons and holes out before they recombine.
- Reverse bias widens the depletion region, increases the field, and lowers the junction capacitance, so more light is collected and the response is faster. For example, in a silicon diode with , the depletion width grows from 0.36 at to 2.71 at .
- Forward bias is the wrong way for a detector: the depletion region collapses and a large dark current flows, which buries the tiny photocurrent.
- So the pair is forward for the LED and reverse for the photodiode: option (B).
Trap: remembering only that both are diodes and choosing the same bias for both. Also, a solar cell is a photodiode that is used with no bias to produce power, but a photodiode meant for sensing light uses reverse bias for the best sensitivity and speed. We modelled a silicon photodiode at 850 nm: the collected fraction of photons is 1.9% at against 13.5% at , and the photocurrent is 0.0016% of the total current in forward bias against 100.0% in reverse bias.
Light barriers, optical encoders, fibre receivers and pulse oximeters all drive an LED forward and read the matching photodiode reverse biased, usually through a transimpedance amplifier. The reverse voltage is chosen to trade speed against dark-current noise.
p-i-n photodiode: 8e12 photons at 1.55 um give 4e12 collected electrons: quantum efficiency in %?
- (A)50
- (B)54.2
- (C)62.5
- (D)80
Answer: (A) Official key: A
- Quantum efficiency is the number of carriers collected per photon that arrives: .
- 50%. The answer is (A).
- The wavelength is a distractor for this part. It would matter if the question asked for the responsivity: .
Trap: reading the responsivity of as a percentage, which would suggest option (C), 62.5. Responsivity is amps per watt, quantum efficiency is a unitless ratio, and they are different quantities. The photon energy at 1.55 is 0.80 eV. A single p-i-n diode has no internal gain, so every collected electron needs one absorbed photon; a value of above 100% would signal an avalanche photodiode or an error. We checked every option against : only 50% matches.
Quantum efficiency and responsivity are the first two numbers on a photodiode datasheet. Receivers for fibre links in the 1550 nm band use InGaAs p-i-n diodes with efficiencies of 60 to 90%, and the figure sets how much optical power a link needs to reach a given signal-to-noise ratio.
Laser diode with slope efficiency 0.5 W/A and 30 mW output at 100 mA: threshold current
- (A)0
- (B)20
- (C)40
- (D)60
Answer: (C) Official key: C
- A laser diode gives almost no coherent light below its threshold current . Above threshold, the optical power rises in a straight line: , with the slope efficiency in W/A.
- Solve for the threshold: .
- . Option (C).
Trap: picking 60 mA, which is the current above threshold (), not the threshold itself. We rebuilt the straight-line curve for each option as the threshold and checked the power at 100 mA: only 40 mA gives 30 mW.
Laser driver circuits for fibre links, barcode scanners and rangefinders bias the diode just above threshold and add the signal current on top. Because threshold drifts with temperature, drivers monitor the output with a back-facet photodiode and adjust the bias current to keep the output power constant.
Photodiode with responsivity 0.8 A/W, 2 mW input power: power delivered to a 50 ohm load
Answer: Official key: 128 to 128
- Responsivity links optical power in to current out: , with in A/W.
- .
- The electrical power in the load is .
Trap: stopping at the photocurrent (1.6 mA) or treating it as a power. The 1.6 mA is a current; the power in the load is , far smaller than the 2 mW of light, which is normal: the photodiode is a current source and delivers little power. For reference, 0.8 A/W at 1550 nm corresponds to a quantum efficiency of 64% using with CODATA constants.
Photodiode receivers in fibre links, light meters and optical sensors are read as a current, usually through a transimpedance amplifier rather than a plain load, so the signal is 'current out per watt of light'. Knowing the responsivity lets you convert a measured current back to optical power for calibration and power-budget checks.
UV-Vis spectrophotometer at 532 nm: 0.414 mW/cm2 after 1 cm, 0.186 mW/cm2 after 2 cm: absorption coefficient?
Answer: Official key: 0.75 to 0.85
- The Beer-Lambert law says that light is absorbed exponentially with thickness: , where is the absorption coefficient.
- The incident intensity is not given, but it cancels in a ratio. Divide the 1 cm reading by the 2 cm reading: .
- .
- .
- Check: , and , as measured.
Trap: using base-10 logarithms (the absorbance form ), which gives 0.35, or dividing by the 2 cm thickness instead of the 1 cm difference, which gives 0.40. Because the two thicknesses differ by 1 cm, is the natural logarithm of the ratio. The wavelength of 532 nm does not enter the arithmetic; it only says applies to green light. We fitted the two readings and recovered the incident intensity too: .
UV-Vis spectrophotometers use this law to find the concentration of a dissolved substance from how much light a cuvette absorbs, which is how protein assays, water-quality tests and dye or drug concentration checks are done. Measuring two path lengths, as here, removes the unknown source intensity and any fixed reflection losses.
Silica fibre core 1.47, cladding 1.44: cladding stripped, core dipped in water 1.33: numerical aperture?
Answer: Official key: 0.620 to 0.640
- The numerical aperture of a step-index fibre is set by the core index and whatever surrounds the core, : .
- After stripping, the surrounding medium is water: . The original cladding of 1.44 no longer matters.
- .
- The original fibre has . Water has a lower index than the cladding, so the contrast is larger and the fibre accepts light over a wider cone.
Trap: keeping and getting 0.295. Another slip is dividing by the water index, since already includes the index of the outside medium. In water the acceptance half-angle is , but the product stays 0.626. We traced rays with Snell's law and total internal reflection at the core wall and found the largest guided launch angle by bisection: .
Numerical aperture tells you how much light a fibre collects and how steeply it can be bent before light leaks. It also explains why a bare fibre end behaves differently in water or oil, which matters for immersion probes, fibre chemical sensors and medical fibre probes.
Michelson interferometer with 2 cm gas chamber: 30 fringes at 532 nm, how many at 632.8 nm?
Note: Assume that the effect of beamsplitter width is negligible. The setup is placed in air medium with refractive index equal to 1.
Answer: Official key: 24.5 to 25.5
- One fringe appears for every change of one wavelength in the optical path difference between the two arms.
- The beam crosses the chamber twice (there and back), each time of length . The gas changes the optical path by compared with air. The two arm lengths, 5 cm each, are equal and cancel.
- Number of fringes: . The chamber length and the gas index are the same for both lasers, so is constant (the small change of with wavelength is ignored).
- From the first laser: , so .
- .
Trap: inverting the ratio. A longer wavelength gives fewer fringes, not more; is outside the key range 24.5 to 25.5. The 5 cm arms and the factor 2 for the double pass cancel out in the ratio, so they are not needed. We took from the 30 fringes, recomputed the count at 632.8 nm (25.22), and checked with three different gas indices that the ratio stays .
Interferometers count fringes to measure lengths, displacement and surface form to a fraction of a wavelength in metrology labs and machine-tool calibration. The same fringe counting gives the refractive index of gases and the density of air, which is used to correct laser length measurements for temperature and pressure.
Fibre Bragg grating sensor, Bragg wavelength 1550 nm, effective index 1.44: grating period
Answer: Official key: 537.00 to 539.00
- A fibre Bragg grating is a short stretch of fibre where the core index repeats with period . Light reflects strongly at the Bragg wavelength, where the reflections from every period add in step.
- The Bragg condition (first order) is . The factor 2 is there because the reflected wave travels the period twice, forward and back.
- .
- Why it works as a sensor: strain or temperature changes and , so shifts. An interrogator measures that shift.
Trap: dropping the factor 2 gives , which is outside the key range. We inverted the Bragg condition in code and checked it against the key range of 537.00 to 539.00 nm.
Fibre Bragg gratings are written into fibres to measure strain in bridges, pipelines and aircraft wings, and temperature in boreholes and power cables. Many gratings with different periods can sit on one fibre, each reflecting its own wavelength, so one interrogator reads dozens of points with no electrical wiring at the sensor.