GATE Instrumentation (IN): Control Systems (steady-state error, Routh, root locus, Bode and Nyquist, state space, PID and compensators), previous-year questions solved
Every control systems question from the last five GATE Instrumentation Engineering papers, solved: Mason's rule, steady-state error, Routh arrays, root locus, gain and phase margins from Bode and Nyquist plots, a time delay read off a phase plot, state-space poles, PID, lead and lag compensators, and a control-valve characteristic. Each answer matches the official key and was recomputed by code (Routh array, closed-loop roots or a simulated response) with the values printed in the paper.
Questions from official GATE IN papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 19 Nov 2026 · 5 of 23 questions on this page
Signal flow graph with gains G1, G2, G3, a return of -1 and an output gain of 2: expression for Y(s)/X(s)
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- Mason's gain rule: , where are the forward path gains, , and is with the loops touching path removed.
- Forward paths from to : through , then , then the gain 2, so . Through , then (the upper arc), then 2, so .
- Loops: forward and back gives . forward and back gives . Both loops use the two middle nodes, so they touch each other, and there is no product term.
- . Both forward paths pass through those nodes, so both touch every loop and .
- . Option (A).
Trap: forgetting that the output branch of gain 2 multiplies both paths. Option D differs only by a stray term (at , , it gives 2.80 against 3.20). We solved the node equations at random gains and compared with every option, and Mason's rule gave 3.20 at , , , the same as the node solution; only option A agrees.
Signal flow graphs are a bookkeeping method for multi-loop control and process models, including the interacting paths in a cascade or a heat exchanger network. Mason's rule gives the overall gain without reducing the diagram step by step.
PID on plant 1/((s+1)(s+2)): Kp doubled, Ki tripled, Kd unchanged; effect on steady-state ramp error
Now, the proportional gain is increased by a factor of 2, the integral gain is increased by a factor of 3, and the derivative gain is left unchanged. Given that the closed-loop system continues to remain stable with the new gains, the steady-state error in tracking a ramp reference signal ________
- (A)Remains unchanged
- (B)Decreases by a factor of 2
- (C)Decreases by a factor of 3
- (D)Decreases by a factor of 5
Answer: (C) Official key: C
- The steady-state error for a ramp input is , where the velocity error constant is and is the loop gain.
- The PID controller is . Its integral term gives the loop a pole at the origin, so the loop is type 1 and a ramp gives a finite error.
- . As only the integral term survives: .
- So . It depends on alone, not on or . Tripling divides the error by 3. Option (C).
Trap: crediting the proportional gain as well, which would give a factor of 2 or 5 (options B and D). For a ramp the proportional and derivative terms vanish in the limit. We computed the closed-loop ramp error from the error transfer function for three stable gain sets (for example , , gives an error of 1.00, and the new gains , , give 0.333); the ratio is 3.00 every time, with Routh stability confirmed for each set.
This is why the integral term is added in a servo or a temperature ramp: it removes the steady offset on a slowly moving setpoint. The integral gain sets the ramp tracking error, so a motion or furnace profile that tracks a ramp uses a larger integral gain as long as the loop stays stable.
Feedback loop 1/(s(s+1)) with gain K in the feedback path: steady-state error to a unit step
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- The error here is defined as , the difference between the reference and the output, not the signal at the summing junction (which is ). With the two are different.
- Closed-loop transfer function: .
- For the poles have negative real parts, so the system is stable and the final value theorem applies. For a unit step, : .
- . Option (A).
Trap: using the type-1 rule \"zero error to a step\" (option C). That rule is for unity feedback. With a feedback gain , the loop makes settle at of the reference. We integrated numerically for = 2, 5 and 10 and got errors of 0.500, 0.800 and 0.900, matching = 0.500, 0.800 and 0.900.
Feedback gain in the measurement path is real: a sensor with a sensitivity other than 1 makes the loop regulate the measured value, so the true process variable settles at the setpoint divided by that sensitivity unless the setpoint or transmitter scaling is corrected. This is why transmitter ranges and setpoint units must match.
Second-order system: damping ratio and natural frequency for poles in the shaded s-plane region
- (A) and
- (B) and
- (C) and
- (D) and
Answer: (A) Official key: A
- The poles of the standard second-order system are . Their distance from the origin is , and the angle between a pole and the negative real axis satisfies .
- The shaded region is bounded by two rays drawn at and from the positive real axis. Measured from the negative real axis, each ray is at . Poles inside the shaded sector therefore have .
- means . A larger means a smaller angle, so the condition is .
- The region lies outside the circle of radius 2 centred on the origin, so . Answer: (A).
Meaning: limits the overshoot to about 16%, and keeps the response fast enough. Trap: measuring the angle from the positive real axis, which gives , a negative damping ratio, instead of 0.5. We sampled each option's whole range against the region test ( and within 60 degrees of the negative real axis): only (A) stays entirely inside.
Specifying a pole region on the s-plane is how overshoot, speed and settling time are turned into a design target for a servo or temperature loop. The controller is then tuned so the closed-loop poles land inside the allowed region.
Unity negative feedback around G(s) = 10(s+1)/(s(s^2+2s+5)): steady-state error to a unit ramp
Answer: Official key: 0.49 to 0.51
- A feedback loop can only have a steady-state error if it is stable, so check that first. The closed-loop characteristic equation is : .
- Routh array: the first column is , with no sign change, so all three closed-loop poles are in the left half-plane. The loop is stable.
- has one pole at the origin, so it is a type 1 system: it follows a step with zero error and a ramp with a constant error. The velocity error constant is .
- For a unit ramp, .
Trap: leaving out the factor at , which gives and an error of . We simulated the closed loop driven by a unit ramp (fourth-order Runge-Kutta, 60 s) and read the error at the end: 0.5000.
Ramp-following error is what a positioner or a temperature programmer shows when it chases a setpoint that changes at a constant rate: the lag behind the setpoint is the ramp rate divided by the velocity error constant. A type 1 loop always lags a ramp, so a controller with a second integrator is used where zero lag is needed.