Part 2 of 2 of the Environmental Engineering hub: 38 more official GATE CE questions on wastewater and sludge treatment, air pollution and municipal solid waste, each solved step by step and checked against the official answer key. Part 1 covers water quality, BOD and stream pollution and water supply and treatment.

Questions from the ten official GATE CE papers, sessions CE1 and CE2 of GATE 2022 (IIT Kharagpur), 2023 (IIT Kanpur), 2024 (IISc Bengaluru), 2025 (IIT Roorkee) and 2026 (IIT Guwahati); solutions by Skill-Lync. · Updated 17 Nov 2026 · 38 of 69 questions on this page

GATE 2022 · CE2 · Q.60NAT · 2 marksWastewater and sludge treatment

5000 m3/day, TSS 200 mg/L, 60 percent removal, sludge thickened from 2 to 6 percent solids: daily volume

A sewage treatment plant receives sewage at a flow rate of 5000 m3/day. The total suspended solids (TSS) concentration in the sewage at the inlet of primary clarifier is 200 mg/L. After the primary treatment, the TSS concentration in sewage is reduced by 60 %. The sludge from the primary clarifier contains 2 % solids concentration. Subsequently, the sludge is subjected to gravity thickening process to achieve a solids concentration of 6 %. Assume that the density of sludge, before and after thickening, is 1000 kg/m3.

The daily volume of the thickened sludge (in m3/day) will be_________. (round off to the nearest integer)

Answer: m3/day Official key: 10 to 10

  1. Solids removed in the primary clarifier: kg/day (1 mg/L = 1 g/m3).
  2. At 2 percent solids, sludge mass kg/day, i.e. 30 m3/day at 1000 kg/m3.
  3. Thickening keeps the solids and removes water: at 6 percent, volume 10 m3/day (key 10 to 10).
  4. Shortcut: volume is inversely proportional to solids content, .

Trap: stopping at the unthickened volume gives 30 m3/day, and using the 40 percent left in the sewage instead of the 60 percent removed gives 6.7; both miss the key.

Where this shows up in industry

Thickening ahead of digesters and centrifuges matters because their size and the pumping cost scale with sludge volume; tripling the solids content cuts that volume to a third.

GATE 2023 · CE1 · Q.64NAT · 2 marksWastewater and sludge treatment

Activated sludge plant, 0.5 m3/s, F/M 0.2 per day, 150 mg/L, MLVSS 2000 mg/L: aeration tank volume

The wastewater inflow to an activated sludge plant is 0.5 m3/s, and the plant is to be operated with a food to microorganism ratio of 0.2 mg/mg-d. The concentration of influent biodegradable organic matter of the wastewater to the plant (after primary settling) is 150 mg/L, and the mixed liquor volatile suspended solids concentration to be maintained in the plant is 2000 mg/L. Assuming that complete removal of biodegradable organic matter in the tank, the volume of aeration tank (in m3, in integer) required for the plant is ________.

Answer: 16200 m3 Official key: 16200 to 16200

  1. Food to microorganism ratio: , the mass of organic matter fed per day per unit mass of microorganisms in the tank.
  2. Put the flow in per-day units to match the ratio: .
  3. .
  4. , so 16200 m3 (key 16200). The hydraulic retention time is hours.

Trap: converting the flow per hour instead of per day gives , 24 times too small; the units of F/M (per day) decide the time base of .

Where this shows up in industry

Operators of activated sludge sewage treatment plants hold the F/M ratio in its design band mainly by adjusting the waste sludge rate, which sets the MLVSS in the aeration tank; too high an F/M gives poor settling and a turbid effluent.

GATE 2023 · CE2 · Q.49MSQ · 2 marksWastewater and sludge treatment

Aerobic composting of sewage sludge: bulking agent, leachate, actinomycetes, in-vessel plug flow

Which of the following statements is/are TRUE for the aerobic composting of sewage sludge?

  1. (A)Bulking agent is added during the composting process to reduce the porosity of the solid mixture
  2. (B)Leachate can be generated during composting
  3. (C)Actinomycetes are involved in the process
  4. (D)In-vessel composting systems cannot be operated in the plug-flow mode

Answer: (B) and (C) Official key: B;C

  1. (A) False. Dewatered sludge is wet and dense. Wood chips, sawdust or straw are added as a bulking agent to increase porosity, so air can reach the microbes, and to absorb moisture.
  2. (B) True. Sludge carries a lot of water; water released as the pile is formed and as organic matter decomposes drains out as leachate, which must be collected and treated.
  3. (C) True. Bacteria, fungi and actinomycetes all take part; actinomycetes are especially active in the later, high-temperature stage, breaking down cellulose and lignin.
  4. (D) False. In-vessel composters are built either as plug-flow reactors (vertical or horizontal, material moving through in order) or as agitated, dynamic reactors.
  5. Answer: (B) and (C).

Trap: (A) reverses the role of the bulking agent. Lower porosity would starve the pile of oxygen and make it go anaerobic and smell.

Where this shows up in industry

Several Indian sewage treatment plants co-compost dried sludge with municipal green waste in windrows, and the compost must meet the Fertiliser Control Order limits for heavy metals before it can be sold for agricultural use.

GATE 2024 · CE1 · Q.60NAT · 2 marksWastewater and sludge treatment

Activated carbon in a mixed batch reactor, first-order rate 0.38 per day: time for 95 % removal

Activated carbon is used to remove a pollutant from wastewater in a mixed batch reactor, which follows first-order reaction kinetics.

At a reaction rate of 0.38 /day, the time (in days) required to remove the pollutant by 95% is ______________ (rounded off to 1 decimal place).

Answer: days Official key: 7.8 to 8.0

  1. In a batch reactor nothing flows in or out, so first-order kinetics gives and .
  2. 95% removal leaves , so .
  3. , so days, i.e. 7.9 days (key 7.8 to 8.0). A step-by-step numerical integration of the rate equation gives the same 7.88 days.

Trap: using instead of the natural log gives days, and treating the decay as linear () gives days; both are outside the key. First-order rate constants always go with .

Where this shows up in industry

Granular activated carbon columns are used for tertiary polishing of industrial effluents and for removing taste, odour and micropollutants in drinking water; bench batch tests like this one give the rate data used to size the contact time of the full-scale columns.

GATE 2024 · CE2 · Q.26MCQ · 1 markWastewater and sludge treatment

Which product is NOT obtained in anaerobic decomposition of glucose: CO2, CH4, H2S or H2O

Which one of the following products is NOT obtained in anaerobic decomposition of glucose?

  1. (A)CO2
  2. (B)CH4
  3. (C)H2S
  4. (D)H2O

Answer: (C) H2S Official key: C

  1. Glucose is C6H12O6: it contains only carbon, hydrogen and oxygen.
  2. Anaerobic digestion runs through hydrolysis, acidogenesis, acetogenesis and methanogenesis. The overall balance is C6H12O6 → 3 CH4 + 3 CO2, so CH4 and CO2 are the main products.
  3. Water is formed too: hydrogen-using methanogens convert CO2 + 4 H2 → CH4 + 2 H2O.
  4. H2S needs sulphur, which glucose does not have. In real digesters H2S comes from sulphate reduction and from sulphur in proteins, not from carbohydrates.
  5. Answer: (C) H2S.

Trap: choosing H2O because the headline equation shows only methane and carbon dioxide; water is produced in the methanogenic step, while sulphur simply cannot appear from a C-H-O molecule.

Where this shows up in industry

Anaerobic digesters at sewage treatment plants turn sludge into biogas, mostly methane and carbon dioxide; the hydrogen sulphide that comes from sulphates and proteins in the sludge is scrubbed out before the gas is burnt in engines or boilers, because it corrodes them.

GATE 2024 · CE2 · Q.60NAT · 2 marksWastewater and sludge treatment

Circular primary settling tank, 10 MLD sewage, 2 h detention, surface loading 40000 L/m2/day: water depth

A circular settling tank is to be designed for primary treatment of sewage at a flow rate of 10 million liters/day. Assume a detention period of 2.0 hours and surface loading rate of 40000 liters/m2/day. The height (in meters) of the water column in the tank is _______________ (rounded off to 2 decimal places).

Answer: Official key: 3.00 to 3.40

  1. Flow L/day .
  2. Volume from detention time: .
  3. Plan area from surface loading rate: (diameter m).
  4. Depth m, so 3.33 m (key 3.00 to 3.40). Shortcut: day, the same 3.333 m.

Trap: leaving the detention time in hours while the flow is per day gives m, an absurd depth; keep and in the same time unit.

Where this shows up in industry

Primary clarifiers at Indian sewage treatment plants are sized this way from the overflow rate and detention time ranges in the CPHEEO Manual on Sewerage and Sewage Treatment, and checked again at peak flow so settled sludge is not washed out.

GATE 2025 · CE1 · Q.45MSQ · 2 marksWastewater and sludge treatment

Facultative wastewater pond: dissolved oxygen and pH by day compared with night

A facultative pond system is employed for wastewater treatment. Which of the following statements is/are true:

  1. (A)The dissolved oxygen concentration will be high during daytime compared to night-time
  2. (B)The pH will be high during daytime compared to night-time
  3. (C)The dissolved oxygen concentration will be low during daytime compared to night-time
  4. (D)The pH will be low during daytime compared to night-time

Answer: (A) and (B) Official key: A;B

  1. A facultative pond has an aerobic upper layer, where algae and bacteria live together, and an anaerobic sludge layer at the bottom.
  2. By day the algae photosynthesise: cell matter . Oxygen is released faster than bacteria use it, so the DO rises during the day, often to supersaturation in the afternoon: (A) true, (C) false.
  3. Photosynthesis also removes , which shifts the carbonate equilibrium (, then is released), so the pH rises by day, sometimes above 9: (B) true, (D) false.
  4. At night photosynthesis stops; algae and bacteria respire, consume oxygen and release , so DO and pH both fall.
  5. Answer: (A) and (B).

Trap: thinking that bacterial activity, which is higher in the warm day, must lower DO by day; in a pond the algae's oxygen production dominates while the sun is up.

Where this shows up in industry

Waste stabilisation ponds are used by many small Indian towns because they need land but almost no power or skilled operation; the high daytime pH and sunlight also help kill faecal bacteria before the effluent is discharged or used for irrigation.

GATE 2025 · CE2 · Q.17MCQ · 1 markWastewater and sludge treatment

Bacteria mainly responsible for crown corrosion in a sewer

The bacteria mainly responsible for crown corrosion in a sewer is ______.

  1. (A)Methanogenic bacteria
  2. (B)Denitrifying bacteria
  3. (C)Sulphur reducing bacteria
  4. (D)Pseudomonas bacteria

Answer: (C) Sulphur reducing bacteria Official key: C

  1. In slow, stale sewage the slime layer on the submerged wall turns anaerobic. There sulphate-reducing bacteria (such as Desulfovibrio) use sulphate as their oxygen source and produce hydrogen sulphide: .
  2. escapes into the sewer air and dissolves in the moisture on the crown (the top of the pipe), which is not washed by the flow.
  3. There, sulphur-oxidising bacteria turn it into sulphuric acid, which attacks the cement paste and corrodes the crown.
  4. The root cause the question asks for is the generation: option (C).

Trap: methanogens (A) also live in anaerobic sewage, but methane is not acidic and does not attack concrete; corrosion follows the sulphur cycle, not the carbon cycle.

Where this shows up in industry

Sewer design keeps velocities self-cleansing and provides ventilation to limit sulphide build-up, and corrosion-resistant pipe materials or linings are used where sewage is warm and stale; the CPHEEO Manual on Sewerage and Sewage Treatment discusses this crown corrosion.

GATE 2025 · CE2 · Q.62NAT · 2 marksWastewater and sludge treatment

ASP for 1 MLD, 250 m3 tank at 3000 mg/L, effluent 10 mg/L, wasting 5000 L/day at 10000 mg/L: sludge age

A community generates 1 million litres/day (MLD) of wastewater. This wastewater is treated using activated sludge process (ASP). The working volume of the aeration tank of the ASP is 250 m3, and the biomass concentration in the tank is 3000 mg/L. Analyses results showed that a biomass concentration of 10 mg/L is present in the treated effluent from the secondary sedimentation tank of the ASP. Sludge wastage from the system is at a rate of 5000 L/day with a biomass concentration of 10000 mg/L. The system is in steady state condition.

The biological sludge residence time (BSRT) of the system (in days) is ______ (round off to one decimal place).

Answer: Official key: 12.3 to 12.7

  1. Sludge residence time = biomass held in the aeration tank / biomass leaving per day: .
  2. Biomass in the tank: g.
  3. Wasted: g/d. Lost in the effluent: g/d. Total g/d.
  4. , so days (key 12.3 to 12.7). Using instead of in the effluent term gives d, practically the same.

Trap: ignoring the solids in the effluent gives days, outside the key; and the hydraulic retention time d is a different quantity altogether.

Where this shows up in industry

Sludge age is the main control knob of an activated sludge plant: operators set the waste sludge pumping rate to hold the target SRT, longer for nitrification and extended aeration, shorter for plain BOD removal.

GATE 2026 · CE1 · Q.25MSQ · 1 markWastewater and sludge treatment

Components NOT removed in the secondary treatment of sewage

Which of the following components is/are NOT removed in the secondary treatment of sewage?

  1. (A)Suspended settleable organic solids
  2. (B)Colloids including dissolved organic matter
  3. (C)Pathogens
  4. (D)Fat and grease

Answer: (A) and (C) and (D) Official key: A;C;D

  1. Secondary treatment is the biological stage (activated sludge, trickling filter, ponds). Microbes eat what settling cannot remove: the colloidal and dissolved organic matter, (B). So (B) is removed there.
  2. Settleable organic solids, (A), are taken out earlier, in primary sedimentation.
  3. Fat and grease, (D), are skimmed off in preliminary or primary units (grease traps, skimming tanks) because they would coat the biomass.
  4. Pathogens, (C), are not the target of the biological stage; they are dealt with by disinfection (tertiary treatment).
  5. Answer: (A), (C) and (D).

Trap: leaving out (A) because some suspended solids do settle in the secondary clarifier; those are the biological floc grown in the aeration tank, not the settleable solids of raw sewage, which primary sedimentation removes.

Where this shows up in industry

This is why a typical Indian sewage treatment plant runs screens and grit removal, then primary clarifiers, then the aeration tank or SBR, and only then chlorination or UV before the treated water is discharged or reused.

GATE 2026 · CE1 · Q.63NAT · 2 marksWastewater and sludge treatment

Activated sludge plant, 20000 m3/day, V 6000 m3, MLSS 3000 mg/l, SRT 6 days, recycle 6000 m3/day: waste flow

An Activated Sludge Process (ASP) has an inlet wastewater flowrate of 20000 m3/day with a Biochemical Oxygen Demand (BOD) concentration of 250 mg/l. It produces treated wastewater containing 20 mg/l BOD. The aeration tank has a working volume of 6000 m3 and a biomass concentration of 3000 mg/l. Biological Sludge Residence Time (BSRT) of the system is 6 days. The influent wastewater and the treated effluent from the system have negligible concentrations of biomass. The sludge recycle line from the bottom of the Secondary Sedimentation Tank (SST) to the inlet of the aeration tank has a flowrate of 6000 m3/day.

To maintain equilibrium, the flowrate (in m3/day) of sludge that is to be wasted from the system is ______ (in integer).

Answer: Official key: 230 to 250

  1. With no biomass in the effluent, all biomass leaves in the waste sludge: , so kg/day.
  2. The waste is drawn from the recycle line, so is needed. Biomass balance on the aeration tank at steady state: in with recycle + net growth = out to the SST, .
  3. , so mg/l.
  4. m3/day, so 240 (key 230 to 250). The common shortcut that drops the growth term gives mg/l and , also inside the key. The BOD values are not needed.

Trap: wasting as if from the aeration tank, m3/day, ignores that recycle sludge is about four times thicker than the mixed liquor; taking gives 300. Both miss the key.

Where this shows up in industry

Operators control an activated sludge plant mainly through the waste sludge pump: wasting a set volume of return sludge each day holds the sludge age, and with it the mixed liquor concentration and the effluent quality.

GATE 2026 · CE2 · Q.28MCQ · 1 markWastewater and sludge treatment

Sludge solids one-third fixed (SG 2.5) and two-thirds volatile (SG 1.0): specific gravity of all solids

One-third of the solid matter in a sludge containing 90 % water is composed of fixed mineral solids with specific gravity 2.5, and two-third is composed of volatile solids with specific gravity 1.0.

Specific gravity of all solids lies between

  1. (A)1.2 and 1.3
  2. (B)1.5 and 1.6
  3. (C)1.7 and 1.8
  4. (D)2.0 and 2.1

Answer: (A) 1.2 and 1.3 Official key: A

  1. Masses add and so do volumes. For a unit mass of solids, volume , so .
  2. , so : (A), between 1.2 and 1.3.
  3. The 90 % water only matters for the sludge itself: , , barely heavier than water.

Trap: averaging the specific gravities by mass, , lands in (B); specific gravity is mass per volume, so the reciprocals (volumes) must be averaged, not the gravities.

Where this shows up in industry

Digester and drying-bed design starts from this solids specific gravity: it converts the dry mass of sludge produced each day into the volume a thickener, digester, tanker or drying bed must handle.

GATE 2026 · CE2 · Q.29MCQ · 1 markWastewater and sludge treatment

Treatment unit in which grown algae are useful

The grown algae are useful in the operation of

  1. (A)oxidation pond.
  2. (B)slow sand filter.
  3. (C)cyclone separator.
  4. (D)septic tank.

Answer: (A) oxidation pond. Official key: A

  1. An oxidation (waste stabilisation) pond works on algae-bacteria symbiosis: bacteria oxidise the organic matter and release CO2, nutrients and water.
  2. Algae use that CO2 and sunlight for photosynthesis and release the oxygen the aerobic bacteria need, so no mechanical aeration is required.
  3. A septic tank is a closed anaerobic tank with no light, and a cyclone separator is a dry mechanical device for dust, so algae play no part there.
  4. Answer (A) oxidation pond.

Trap: (B) slow sand filter. Its biological skin (schmutzdecke) does contain algae, but heavy algal growth in raw water clogs the filter and shortens its run; it is a problem to control, not the working principle.

Where this shows up in industry

Waste stabilisation ponds are common for the sewage of small Indian towns because they need almost no power: algae supply the oxygen that bacteria use to break down the organic load, in exchange for large land area.

GATE 2026 · CE2 · Q.64NAT · 2 marksWastewater and sludge treatment

Anaerobic treatment, Y = 0.06 g VSS per g COD, biomass C6H7NO2: percentage of COD converted to biomass

Anaerobic bacteria are being utilized for the destruction of biodegradable organic content of wastewater measured in terms of Chemical Oxygen Demand (COD). The yield coefficient (Y) is 0.06 gram Volatile Suspended Solids (VSS) per gram of COD. Bacterial biomass forms the sludge during the process. The proximate chemical formula of anaerobic bacteria is C6H7NO2.

The COD (in %) converted into bacterial biomass is ______ (rounded off to the nearest integer).

Answer: % Official key: 8 to 10

  1. Yield is in grams of cells, so convert cells to their own COD. Oxidise the biomass fully, with nitrogen going to ammonia: (C, H and O balance).
  2. Molar mass g; oxygen demand g, so 1 g cells g COD.
  3. COD into biomass g per g COD removed, i.e. 9.2 %, so 9 % (key 8 to 10). The rest leaves mostly as methane.
  4. With the textbook formula C5H7NO2 (1.42 g COD/g) the share is 8.5 %, also in the key.

Trap: reading the yield as a COD fraction gives 6 %, outside the key; Y is in grams of VSS, and each gram of cells holds about 1.5 g of COD.

Where this shows up in industry

Anaerobic reactors such as the UASB plants used for sewage in many Indian cities produce far less sludge than aerobic plants because so little of the COD goes into new cells; most of it leaves as methane-rich biogas.

GATE 2022 · CE2 · Q.22MCQ · 1 markAir pollution

Equipment emits 5 kg/h of VOCs and a hood captures 95 percent: fugitive emission

A process equipment emits 5 kg/h of volatile organic compounds (VOCs). If a hood placed over the process equipment captures 95% of the VOCs, then the fugitive emission in kg/h is

  1. (A)0.25
  2. (B)4.75
  3. (C)2.50
  4. (D)0.48

Answer: (A) 0.25 kg/h Official key: A

  1. Fugitive emissions are the part that escapes the capture system and enters the air without passing through a stack or control device.
  2. Captured by the hood: kg/h, which is ducted to treatment.
  3. Escaping: kg/h, so (A) 0.25 kg/h.
  4. If the captured stream then goes to a control device of efficiency , the stack adds kg/h on top of the fugitive 0.25 kg/h.

Trap: answering with the captured amount, 4.75 kg/h, option (B). 'Fugitive' is what the hood misses.

Where this shows up in industry

Emission inventories count capture efficiency and control efficiency separately, because VOCs that escape the hood reach the workplace and ambient air untreated however good the scrubber or carbon bed downstream is.

GATE 2022 · CE2 · Q.61NAT · 2 marksAir pollution

Air at 25 C and 1 atm with 0.04 ppm of SO2: concentration in micrograms per cubic metre

A sample of air analyzed at 25 °C and 1 atm pressure is reported to contain 0.04 ppm of SO2. Atomic mass of S = 32, O = 16.

The equivalent SO2 concentration (in µg/m3) will be__________. (round off to the nearest integer)

Answer: µg/m3 Official key: 102 to 108

  1. For gases ppm is by volume: 0.04 ppm means 0.04 litres of SO2 per 106 L, i.e. per 1000 m3 of air.
  2. Molar volume at 25 C and 1 atm: L/mol.
  3. Molar mass of SO2 g/mol.
  4. µg/m3, so 105 µg/m3 (key 102 to 108).

Trap: using 22.4 L/mol, the molar volume at 0 C, gives 114; using the atomic mass of sulphur alone gives 52. Both are outside the key.

Where this shows up in industry

CPCB's National Ambient Air Quality Standards (2009) limit SO2 to 50 ug/m3 annual and 80 ug/m3 over 24 hours in industrial and residential areas, so this level, if it held for a whole day, would exceed the 24-hour limit.

GATE 2023 · CE1 · Q.20MCQ · 1 markAir pollution

Which statement about greenhouse gases and solar and terrestrial radiation is true

Which one of the following statements is TRUE for Greenhouse Gas (GHG) in the atmosphere?

  1. (A)GHG absorbs the incoming short wavelength solar radiation to the earth surface, and allows the long wavelength radiation coming from the earth surface to pass through
  2. (B)GHG allows the incoming long wavelength solar radiation to pass through to the earth surface, and absorbs the short wavelength radiation coming from the earth surface
  3. (C)GHG allows the incoming long wavelength solar radiation to pass through to the earth surface, and allows the short wavelength radiation coming from the earth surface to pass through
  4. (D)GHG allows the incoming short wavelength solar radiation to pass through to the earth surface, and absorbs the long wavelength radiation coming from the earth surface

Answer: (D) passes short-wave sunlight in, absorbs the earth's long-wave radiation Official key: D

  1. The wavelength a body radiates at peaks where (Wien's law).
  2. The sun's surface is about 5800 K, so its radiation peaks near : short wave (visible and near infrared). The earth's surface is about 288 K, so it radiates around : long wave (thermal infrared).
  3. CO2, CH4, N2O and water vapour are nearly transparent to the short-wave band but absorb strongly in the infrared, then re-radiate part of it back down. That trapped outgoing energy is the greenhouse effect.
  4. So GHGs let incoming short-wave radiation through and absorb outgoing long-wave radiation: option (D).

Trap: (A) swaps the two bands. Sunlight is the short-wave stream; the radiation leaving the earth is the long-wave one, because the earth is about twenty times cooler than the sun.

Where this shows up in industry

India's long-term target of net zero emissions by 2070 is accounted in CO2-equivalent, where each gas is weighted by how strongly it absorbs this outgoing infrared over 100 years; methane from landfills and sewage counts many times more than CO2.

GATE 2023 · CE1 · Q.50MSQ · 2 marksAir pollution

Maximum mixing depth in the atmosphere: unstable layer, ventilation coefficient, pollution potential

Which of the following statements is/are TRUE in relation to the Maximum Mixing Depth (or Height) 'Dmax' in the atmosphere?

  1. (A)Dmax is always equal to the height of the layer of unstable air
  2. (B)Ventilation coefficient depends on Dmax
  3. (C)A smaller Dmax will have a smaller air pollution potential if other meteorological conditions remain same
  4. (D)Vertical dispersion of pollutants occurs up to Dmax

Answer: (B) and (D) Official key: B;D

  1. Dmax is found by drawing the dry adiabatic lapse line up from the maximum surface temperature of the day; it is the height where that line meets the actual temperature profile.
  2. (A) False. That height depends on the whole profile, including stable and neutral layers above the ground, not only on a layer of unstable air; the word 'always' fails.
  3. (B) True. Ventilation coefficient = Dmax times the mean wind speed in the mixed layer.
  4. (C) False. With a 2 m/s wind, = 300 m gives and 1500 m gives . A smaller depth means less air to dilute the same emission, so a higher pollution potential.
  5. (D) True. Pollutants mix vertically only up to Dmax; above it a stable layer acts as a lid.
  6. Answer: (B) and (D).

Trap: (C) reverses the effect. A shallow mixing layer, as on calm winter mornings, is exactly when smog builds up.

Where this shows up in industry

Delhi's worst winter smog episodes come when cold, calm nights shrink the mixing height to a few hundred metres, so the same traffic, industry and burning emissions are squeezed into a much smaller volume of air.

GATE 2023 · CE2 · Q.34NAT · 1 markAir pollution

Temperature 14.2 C at 5 m and 16.9 C at 325 m: existing environmental lapse rate per 100 m

For the elevation and temperature data given in the table, the existing lapse rate in the environment is ________ °C/100 m (round off to two decimal places).

Elevation from ground level (m)Temperature (°C)
514.2
32516.9

Two readings only.

Answer: 0.84 °C/100 m Official key: 0.84 to 0.85

  1. The environmental lapse rate is the rate of change of temperature with height in the actual atmosphere, from the two readings.
  2. Height difference m; temperature difference °C.
  3. Rate C per 100 m, so 0.84 C/100 m (key 0.84 to 0.85).
  4. Temperature rises with height here, so this is an inversion: far more stable than the dry adiabatic rate of about 0.98 °C/100 m of cooling. Rising plumes are held down and pollutants accumulate near the ground.

Trap: dividing by 325 m instead of the 320 m between the two readings gives , just outside the key; the elevations are measured from ground level, not from the lower thermometer.

Where this shows up in industry

Air quality studies for EIA reports and stack design measure temperature at several heights, by met towers or balloon soundings, precisely to spot inversions like this one, which govern ground-level concentrations at night and in early mornings.

GATE 2023 · CE2 · Q.45MCQ · 2 marksAir pollution

Match aromatic hydrocarbons, carbon monoxide, sulfur oxides and ozone with their adverse health effects

Match the following air pollutants with the most appropriate adverse health effects:

Air pollutantHealth effect to human and/or test animal
(P) Aromatic hydrocarbons(I) Reduce the capability of the blood to carry oxygen
(Q) Carbon monoxide(II) Bronchitis and pulmonary emphysema
(R) Sulfur oxides(III) Damage of chromosomes
(S) Ozone(IV) Carcinogenic effect

Choose one option.

  1. (A)(P) - (II), (Q) - (I), (R) - (IV), (S) - (III)
  2. (B)(P) - (IV), (Q) - (I), (R) - (III), (S) - (II)
  3. (C)(P) - (III), (Q) - (I), (R) - (II), (S) - (IV)
  4. (D)(P) - (IV), (Q) - (I), (R) - (II), (S) - (III)

Answer: (D) P-IV, Q-I, R-II, S-III Official key: D

  1. Carbon monoxide binds to haemoglobin about 200 times more strongly than oxygen, forming carboxyhaemoglobin, so the blood carries less oxygen: Q-I (all four options agree).
  2. Aromatic hydrocarbons such as benzene and benzo(a)pyrene are known carcinogens: P-IV. That leaves (B) and (D).
  3. Sulfur oxides are water soluble and irritate the upper airways; long exposure, especially with particulates, leads to chronic bronchitis and emphysema: R-II. This removes (B).
  4. Ozone is a strong oxidant; besides lung irritation, it has caused chromosome damage in test animals in the classic textbook tables: S-III.
  5. Answer: option (D).

Trap: (B) swaps sulfur oxides and ozone. Both irritate the lungs, but bronchitis and emphysema are the classic sulfur-oxide (London smog) effect.

Where this shows up in industry

India's National Ambient Air Quality Standards of 2009 cover all four groups: carbon monoxide, sulfur dioxide and ozone with short-term limits, and benzene and benzo(a)pyrene with annual limits because their carcinogenic risk builds up over long exposure.

GATE 2024 · CE1 · Q.31MSQ · 1 markAir pollution

Which of sulphur dioxide, lead, ozone and sulphuric acid are primary air pollutants

The primary air pollutant(s) is/are

  1. (A)Sulphur dioxide
  2. (B)Lead
  3. (C)Ozone
  4. (D)Sulphuric acid

Answer: (A) and (B) Official key: A;B

  1. A primary pollutant is emitted directly from a source in the form in which it is found in the air; a secondary pollutant forms in the atmosphere by reactions among primary pollutants and natural constituents.
  2. Sulphur dioxide (A) comes straight out of stacks when coal and oil containing sulphur are burnt: primary.
  3. Lead (B) is emitted as particles from smelters, battery recycling and (formerly) leaded petrol: primary.
  4. Ozone (C) is not emitted by any significant source; it forms when NOx and volatile organic compounds react in sunlight (photochemical smog): secondary.
  5. Sulphuric acid (D) forms when SO2 is oxidised to SO3 and absorbed in moisture, the origin of acid rain: secondary.
  6. Answer: (A) and (B).

Trap: ticking sulphuric acid because it contains sulphur like SO2; it is a product of SO2 oxidation in the air, so it is secondary.

Where this shows up in industry

India's National Ambient Air Quality Standards (CPCB, 2009) cover twelve pollutants, including sulphur dioxide, lead and ozone; ozone is controlled indirectly, by cutting the NOx and VOC emissions from vehicles and industry that form it.

GATE 2024 · CE1 · Q.43MCQ · 2 marksAir pollution

Incinerator flue gas: HCl 42 mg/Nm3 at 13 % O2 against a 50 mg/Nm3 standard at 11 % O2, compliance

For assessing the compliance with the emissions standards of incineration plants, a correction needs to be applied to the measured concentrations of air pollutants. The emission standard (based on 11% Oxygen) for HCl is 50 mg/Nm3 and the measured concentrations of HCl and Oxygen in flue gas are 42 mg/Nm3 and 13%, respectively.

Assuming 21% Oxygen in air, the CORRECT statement is:

  1. (A)No compliance, as the corrected HCl emission is greater than the emission standard.
  2. (B)Compliance is there, as the corrected HCl emission is lesser than the emission standard.
  3. (C)Compliance is there, as there is no need to apply the correction since Oxygen is greater than 11% and HCl emission is lesser than the emission standard.
  4. (D)No compliance, as the Oxygen is greater than 11% in the flue gas.

Answer: (A) No compliance, as the corrected HCl emission is greater than the emission standard. Official key: A

  1. Extra air dilutes the flue gas, so a plant could meet a concentration limit just by blowing in more air. Standards are therefore stated at a reference oxygen level and measurements are corrected to it.
  2. Correction: , the ratio of the oxygen consumed (non-air fraction) at the reference and at the measured state.
  3. .
  4. , so the plant does not comply: option (A). The 13% oxygen means the gas was more diluted than the reference, which made the raw 42 look acceptable.

Trap: turning the factor upside down, , suggests compliance, option (B); (C) skips the correction altogether. Higher measured oxygen must always push the corrected value up.

Where this shows up in industry

Waste incinerator limits in India and Europe are quoted at a reference oxygen content, 11 percent for waste incineration, so continuous emission monitors log flue gas oxygen beside every pollutant and the reported values are corrected exactly this way.

GATE 2024 · CE2 · Q.25MCQ · 1 markAir pollution

Match NO2, SO2, CO and particles to NH3 injection, lime scrubbing, flaring and cyclonic separator

What is the CORRECT match between the air pollutants and treatment techniques given in the table?

Air pollutantsTreatment techniques
P - NO2i - Flaring
Q - SO2ii - Cyclonic separator
R - COiii - Lime scrubbing
S - Particlesiv - NH3 injection
  1. (A)P-i, Q-ii, R-iii, S-iv
  2. (B)P-ii, Q-i, R-iv, S-iii
  3. (C)P-ii, Q-iii, R-iv, S-i
  4. (D)P-iv, Q-iii, R-i, S-ii

Answer: (D) P-iv, Q-iii, R-i, S-ii Official key: D

  1. NO2 (P): injecting ammonia (or urea) into the flue gas reduces nitrogen oxides to N2 and water, in selective catalytic or non-catalytic reduction: NH3 injection (iv).
  2. SO2 (Q) is an acid gas; a lime or limestone slurry absorbs it as calcium sulphite/sulphate (gypsum): lime scrubbing (iii).
  3. CO (R) is combustible; burning it in a flare oxidises it to CO2: flaring (i).
  4. Particles (S) are removed by inertia in a cyclonic separator (ii), which spins the gas so that heavier particles hit the wall and drop out.
  5. P-iv, Q-iii, R-i, S-ii is option (D).

Trap: (C) also sends SO2 to lime scrubbing but gives particles to flaring and NO2 to a cyclone; a cyclone only works on solid or liquid particles, never on a gas.

Where this shows up in industry

Under the 2015 emission norms for Indian coal power plants, units are installing limestone-based flue gas desulphurisation for SO2 and ammonia or urea based reduction systems for NOx, while cyclones serve as pre-cleaners ahead of electrostatic precipitators.

GATE 2025 · CE1 · Q.22MCQ · 1 markAir pollution

Hydrocarbon CnHm burnt in air (O2 + 3.78 N2): stoichiometric fuel to air mass ratio

A hydrocarbon (CnHm) is burnt in air (O2 + 3.78N2). The stoichiometric fuel to air mass ratio for this process is

Note: Atomic Weight: C(12), H(1)
Effective Molecular Weight: Air(28.8)
Ignore any conversion of N2 in air to the oxides of nitrogen (NOx)

  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (D) Official key: D

  1. Balance: . Each C needs one and each H a quarter of one.
  2. Moles of air per mole of fuel: .
  3. Mass of air: . Mass of fuel: .
  4. Fuel to air: , option (D).
  5. Check on methane (, ): air to fuel = , the textbook value for natural gas.

Trap: option (C) is the air to fuel ratio, the reciprocal of what is asked, and (A), (B) mix the two groupings; read whether fuel or air sits on top.

Where this shows up in industry

Burners, boilers and incinerators are run with excess air above this stoichiometric amount to complete combustion and cut carbon monoxide; petrol engines run near an air to fuel ratio of 14.7 so that the three-way catalytic converter can work.

GATE 2025 · CE2 · Q.63NAT · 2 marksAir pollution

Air settling chamber 12 m long, 2 m high, 0.2 m/s, particles of G 2.65: smallest size removed completely

A settling chamber is used for the removal of discrete particulate matter from air with following conditions. Horizontal velocity of air = 0.2 m/s; Temperature of air stream = 77°C; Specific gravity of particle to be removed = 2.65;
Chamber length = 12 m; Chamber height = 2 m;
Viscosity of air at 77°C = kg/m.s;
Acceleration due to gravity (g) = 9.81 m/s2; Density of air at 77°C = 1.0 kg/m3;
Assume the density of water as 1000 kg/m3 and Laminar condition exists in the chamber.

The minimum size of particle that will be removed with 100% efficiency in the settling chamber (in µm) is ______ (round off to one decimal place).

Answer: Official key: 21.0 to 45.0

  1. A particle entering at the top must fall the full height in the time the air takes to cross the length : m/s.
  2. Stokes' law in air: with kg/m3.
  3. µm, so µm (key 21.0 to 45.0).
  4. Check: particle Reynolds number , well below 1, so Stokes' law holds.

Trap: writing (ratio upside down) gives µm, far outside the key; the chamber needs the time to cross () to be at least the time to fall ().

Where this shows up in industry

Gravity settling chambers only catch coarse dust, so industry uses them as pre-cleaners ahead of cyclones, bag filters or electrostatic precipitators, which handle the fine particles that count towards the PM10 and PM2.5 limits in the CPCB National Ambient Air Quality Standards 2009.

GATE 2026 · CE2 · Q.27MCQ · 1 markAir pollution

Match dust, CO, SO2 and fine fly ash with cyclone, wet lime scrubber, ESP and catalytic converter

Column I presents common air pollutants, and column II presents treatment technologies commonly employed to control air pollutants.

Air pollutantTreatment technology
1Dust (size 5-25 µm)PCyclone separator
2Carbon monoxide (CO)QWet lime-water scrubber
3Sulfur dioxide (SO2)RElectrostatic precipitator
4Fly ash (size < 2.5 µm)SCatalytic converter

The option that CORRECTLY matches the air pollutant with its treatment technology is:

  1. (A)1 - P ; 2 - S ; 3 - Q ; 4 - R
  2. (B)1 - P ; 2 - R ; 3 - S ; 4 - Q
  3. (C)1 - R ; 2 - Q ; 3 - P ; 4 - S
  4. (D)1 - R ; 2 - Q ; 3 - S ; 4 - P

Answer: (A) 1 - P ; 2 - S ; 3 - Q ; 4 - R Official key: A

  1. Dust of 5-25 µm is coarse enough to be thrown out by centrifugal force: cyclone separator (1-P).
  2. Carbon monoxide is a gas that cannot be filtered or scrubbed easily; it is oxidised to CO2 over a catalyst: catalytic converter (2-S).
  3. Sulfur dioxide is an acid gas; lime or limestone slurry absorbs it as calcium sulfite/sulfate: wet lime-water scrubber (3-Q).
  4. Fly ash below 2.5 µm slips through a cyclone; charging the particles and collecting them on plates captures fine dust efficiently: electrostatic precipitator (4-R).
  5. Answer (A).

Trap: (D) sends the coarse dust to the precipitator and the fine fly ash to the cyclone, the wrong way round: a cyclone's efficiency falls sharply for particles of a few micrometres.

Where this shows up in industry

Coal power stations in India collect fly ash with electrostatic precipitators and are fitting wet limestone flue gas desulphurisation units to meet the 2015 MoEFCC SO2 limits, while petrol cars rely on three-way catalytic converters for CO.

GATE 2026 · CE2 · Q.65NAT · 2 marksAir pollution

Cyclone 80 % efficient followed by an ESP 50 % efficient, inlet 10 mg/m3: exit particle concentration

In an industry, a cyclone collector with 80 % efficiency is installed for air purification, followed by an electrostatic precipitator with 50 % efficiency. The concentration of particles entering the cyclone collector is 10 mg/m3.

The concentration (in mg/m3) of particles exiting the precipitator is __________ (rounded off to two decimal places).

Answer: Official key: 0.90 to 1.10

  1. Each unit removes its efficiency share of what reaches it, so units in series multiply their penetrations .
  2. After the cyclone: mg/m3.
  3. After the precipitator: mg/m3, so 1.00 (key 0.90 to 1.10).
  4. Overall efficiency %.

Trap: multiplying the efficiencies, %, gives an exit of 6.00 mg/m3, and counting only the precipitator gives 5.00; in series the penetrations multiply, not the efficiencies.

Where this shows up in industry

Cement plants and boilers often put a cyclone ahead of an electrostatic precipitator or bag filter: the cyclone takes the coarse dust load cheaply so the final unit can meet the stack emission limit.

GATE 2022 · CE2 · Q.26MSQ · 1 markMunicipal solid waste

Moisture content of food, paper and glass waste and energy content of plastic, food and glass waste

In a solid waste handling facility, the moisture contents (MC) of food waste, paper waste, and glass waste were found to be MCf, MCp, and MCg, respectively. Similarly, the energy contents (EC) of plastic waste, food waste, and glass waste were found to be ECpp, ECf, and ECg, respectively. Which of the following statement(s) is/are correct?

  1. (A)MCf > MCp > MCg
  2. (B)ECpp > ECf > ECg
  3. (C)MCf < MCp < MCg
  4. (D)ECpp < ECf < ECg

Answer: (A, B) Official key: A, B

  1. Typical as-discarded moisture contents (Tchobanoglous): food waste about 70 percent, paper about 6 percent, glass about 2 percent. So MCf > MCp > MCg: (A) true, (C) false.
  2. Typical energy contents: plastics about 32,600 kJ/kg (they are hydrocarbons), food waste about 4,650 kJ/kg (wet, so much of its heat goes into evaporating water), glass about 150 kJ/kg (inert, the little energy is from labels and residue).
  3. So ECpp > ECf > ECg: (B) true, (D) false.
  4. Answer: (A) and (B).

Trap: assuming paper is wetter than food waste because it soaks up water. Fresh food waste is mostly water; paper only becomes wet when mixed with it, which is why source segregation matters.

Where this shows up in industry

The Solid Waste Management Rules 2016 require segregation at source into biodegradable, non-biodegradable and domestic hazardous streams, so wet food waste goes to composting or biomethanation and dry, high-energy plastics and paper to recycling or refuse-derived fuel.

GATE 2022 · CE2 · Q.27MSQ · 1 markMunicipal solid waste

Rules for an optimum municipal solid waste collection route: which one is NOT desired

To design an optimum municipal solid waste collection route, which of the following is/are NOT desired:

  1. (A)Collection vehicle should not travel twice down the same street in a day.
  2. (B)Waste collection on congested roads should not occur during rush hours in morning or evening.
  3. (C)Collection should occur in the uphill direction.
  4. (D)The last collection point on a route should be as close as possible to the waste disposal facility.

Answer: (C) Official key: C

  1. Standard route-layout heuristics (Tchobanoglous) aim to cut dead-heading, fuel and delay.
  2. (A) Avoiding repeated travel down the same street removes unproductive distance: desired.
  3. (B) Keeping off congested roads at rush hour saves time and avoids blocking traffic: desired.
  4. (D) Ending the route close to the disposal or transfer site shortens the loaded haul: desired.
  5. (C) Collection should start at the top of a slope and proceed downhill, so the truck gains load as it descends and does not climb when heavy. Uphill collection is NOT desired.
  6. Answer: (C) only.

Trap: reading the question as 'which are desired' and ticking (A), (B) and (D). Note the bold NOT; only one statement breaks the rules, so this MSQ has a single correct option.

Where this shows up in industry

Collection and transport typically take the largest share of a city's solid waste budget, which is why municipal routes are now planned and tracked with GPS on collection vehicles, still following these layout rules.

GATE 2022 · CE2 · Q.43MCQ · 2 marksMunicipal solid waste

Forced-aeration composting of MSW C100H250O80N, N to NH3: theoretical air per tonne

In a city, the chemical formula of biodegradable fraction of municipal solid waste (MSW) is C100H250O80N. The waste has to be treated by forced-aeration composting process for which air requirement has to be estimated.

Assume oxygen in air (by weight) = 23 %, and density of air = 1.3 kg/m3. Atomic mass: C = 12, H = 1, O = 16, N = 14.

C and H are oxidized completely whereas N is converted only into NH3 during oxidation.

For oxidative degradation of 1 tonne of the waste, the required theoretical volume of air (in m3/tonne) will be (round off to the nearest integer)

  1. (A)4749
  2. (B)8025
  3. (C)1418
  4. (D)1092

Answer: (A) 4749 m3/tonne Official key: A

  1. For going to CO2, H2O and NH3, the oxygen needed is mol O2 per mol.
  2. With : mol O2.
  3. Molar mass of the waste g/mol, so O2 per tonne kg.
  4. Air mass kg; air volume m3, so (A) 4749 m3/tonne.

Trap: multiplying the air mass by the density gives 8025, option (B); skipping the 23 percent step and dividing the oxygen mass by the air density gives 1092, option (D); (C) is roughly the oxygen mass in kg.

Where this shows up in industry

Blowers for aerated static piles and in-vessel composters are sized from this stoichiometric air and then several times more, because most of the airflow is needed to carry away heat and moisture rather than to supply oxygen.

GATE 2022 · CE2 · Q.59NAT · 2 marksMunicipal solid waste

30 t of food, yard and paper waste at 10 percent moisture: water to add to reach 50 percent for composting

At a municipal waste handling facility, 30 metric ton mixture of food waste, yard waste, and paper waste was available. The moisture content of this mixture was found to be 10%. The ideal moisture content for composting this mixture is 50%. The amount of water to be added to this mixture to bring its moisture content to the ideal condition is _______metric ton. (in integer)

Answer: t Official key: 24 to 24

  1. Moisture content in solid waste practice is on a wet basis: water mass over total mass.
  2. Dry solids do not change: t.
  3. At 50 percent moisture the dry solids are half the total, so the total must be t.
  4. Water to add 24 t (key 24 to 24).

Trap: taking 40 percent of the original 30 t gives 12 t, which ignores that the added water also increases the total mass; and 54 t is the new total, not the water added.

Where this shows up in industry

Windrow composting plants run at roughly 50 to 60 percent moisture: drier piles stop microbial activity, wetter ones turn anaerobic and smell, so dry yard waste is wetted or blended with wet food waste.

GATE 2023 · CE1 · Q.28MSQ · 1 markMunicipal solid waste

Refuse-derived fuel from municipal solid waste: heating value, powdered form, inorganic fraction, co-firing

Which of the following statements is/are TRUE for the Refuse-Derived Fuel (RDF) in the context of Municipal Solid Waste (MSW) management?

  1. (A)Higher Heating Value (HHV) of the unprocessed MSW is higher than the HHV of RDF processed from the same MSW
  2. (B)RDF can be made in the powdered form
  3. (C)Inorganic fraction of MSW is mostly converted to RDF
  4. (D)RDF cannot be used in conjunction with oil

Answer: (B) Official key: B

  1. RDF is the combustible fraction of MSW left after shredding, screening, magnetic and air separation and drying.
  2. (A) False. Processing removes water, glass, metals, stones and grit, which carry no heat, so the RDF has a higher heating value per kilogram than the raw waste it came from.
  3. (B) True. RDF is produced as coarse fluff, as densified pellets or briquettes, and as a fine powdered (dust) fuel that can be fired like pulverised coal.
  4. (C) False. The inorganic fraction is what the separation stages take out; it goes to recycling or to landfill.
  5. (D) False. RDF is commonly co-fired with coal or oil in boilers and cement kilns.
  6. Answer: (B) only.

Trap: (A) sounds plausible because 'unprocessed' feels richer, but heating value is per unit mass; removing incombustible mass raises it.

Where this shows up in industry

The Solid Waste Management Rules 2016 direct that non-recyclable waste with a calorific value of 1500 kcal/kg or more be used for energy, through RDF or co-processing in cement kilns, instead of being landfilled.

GATE 2023 · CE1 · Q.62NAT · 2 marksMunicipal solid waste

Solid waste of five components, 26 % moisture: energy content on a dry-weight basis

The composition and energy content of a representative solid waste sample are given in the table. If the moisture content of the waste is 26%, the energy content of the solid waste on dry-weight basis is ________ MJ/kg (round off to one decimal place).

ComponentPercent by massEnergy content as-discarded basis (MJ/kg)
Food waste204.5
Paper4516.0
Cardboard514.0
Plastics1032.0
Others208.0

Energy values are on an as-discarded basis.

Answer: 18.4 MJ/kg Official key: 18.0 to 19.0

  1. Energy of 1 kg of waste as discarded: weight each component by its mass fraction.
  2. MJ/kg.
  3. That kilogram contains 26 % water, so only 0.74 kg of dry solids carry the 13.6 MJ.
  4. Dry basis: MJ/kg, so 18.4 MJ/kg (key 18.0 to 19.0).

Trap: multiplying by 0.74 instead of dividing gives MJ/kg, which is lower than the as-discarded value, impossible for a dry basis; a plain average of the five energy values gives MJ/kg because it ignores the mass fractions.

Where this shows up in industry

Indian mixed MSW is wet and food-heavy, so its calorific value is usually far lower than this paper-rich sample; several early waste-to-energy plants struggled for that reason, and the SWM Rules 2016 push segregation at source before any thermal treatment.

GATE 2023 · CE2 · Q.22MCQ · 1 markMunicipal solid waste

What 'haul' covers in a hauled container system operated in conventional mode

In the context of Municipal Solid Waste Management, 'Haul' in 'Hauled Container System operated in conventional mode' includes the ________.

  1. (A)time spent by the transport truck at the disposal site
  2. (B)time spent by the transport truck in traveling between a pickup point and the disposal site with a loaded container
  3. (C)time spent by the transport truck in picking up a loaded container at a pickup point
  4. (D)time spent by the transport truck in driving from the depot to the first pickup point

Answer: (B) travel between a pickup point and the disposal site with a loaded container Official key: B

  1. The time per trip of a hauled container system is split into pickup, at-site and haul times: .
  2. Pickup (): driving to the next container, picking up the loaded container and setting down the empty one: that is option (C).
  3. At-site time (): time spent at the disposal site unloading and waiting: option (A).
  4. Haul (): time to drive from the pickup point to the disposal site with the loaded container, plus the drive back to where the empty container is to be redeposited: option (B).
  5. Option (D), the drive from the depot to the first pickup point, is off-route time counted once per day, not part of each trip.

Trap: (A) feels like part of the 'haul' because it happens at the end of the trip, but the time at the disposal site is booked separately as at-site time.

Where this shows up in industry

Indian cities use hauled container systems, typically dumper placers or hook-loaders carrying skips, for large generators such as markets and construction sites; haul time is usually the largest share of a trip, which is why transfer stations are planned once disposal sites are far away.

GATE 2024 · CE1 · Q.21MCQ · 1 markMunicipal solid waste

Match MSW components (ferrous, aluminium and copper, food waste, cardboard) to separation or treatment

The following table gives various components of Municipal Solid Waste (MSW) and a list of treatment/separation techniques.

Component of MSWTreatment/separation technique
P - Ferrous metalsi - Incineration
Q - Aluminum and copperii - Rapid composting
R - Food wasteiii - Eddy current separator
S - Cardboardiv - Magnetic separator

The CORRECT match is

  1. (A)P-iii, Q-iv, R-i, S-ii
  2. (B)P-iv, Q-iii, R-ii, S-i
  3. (C)P-iii, Q-iv, R-ii, S-i
  4. (D)P-iv, Q-iii, R-i, S-ii

Answer: (B) P-iv, Q-iii, R-ii, S-i Official key: B

  1. Ferrous metals (P) are attracted by a magnet, so an overhead belt or drum magnetic separator (iv) pulls iron and steel out of the waste stream.
  2. Aluminium and copper (Q) are conductive but not magnetic. An eddy current separator (iii) spins a magnetic rotor that induces currents in them; the opposing field throws them off the belt, away from plastics and glass.
  3. Food waste (R) is wet, readily biodegradable organic matter, the ideal feed for rapid composting (ii); its high moisture makes it a poor fuel.
  4. Cardboard (S) is dry with a high calorific value, so it suits incineration (i) or refuse-derived fuel when it is not recycled.
  5. P-iv, Q-iii, R-ii, S-i is option (B).

Trap: (D) gets both metals right but sends food waste to the incinerator and cardboard to composting; wet food waste burns badly, which is why it is composted or digested instead.

Where this shows up in industry

The Solid Waste Management Rules 2016 require segregation at source into wet, dry and domestic hazardous waste; material recovery facilities then use magnets and eddy current separators on the dry stream, while the wet stream goes to composting or biomethanation.

GATE 2024 · CE2 · Q.61NAT · 2 marksMunicipal solid waste

Organic waste C240O200H180N5S burnt with all sulphur to SO2: grams of SO2 per kg of waste

An organic waste is represented as C240O200H180N5S.

(Atomic weights: S-32, H-1, C-12, O-16, N-14).

Assume complete conversion of S to SO2 while burning.

SO2 generated (in grams) per kg of this waste is ___________ (rounded off to 1 decimal place).

Answer: Official key: 9.9 to 10.2

  1. Molar mass of the waste: C , O , H , N , S ; total g/mol.
  2. Each mole of waste has one atom of S, and gives one mole of SO2 = 64 g.
  3. SO2 per kg of waste g, so 10.1 g (key 9.9 to 10.2).
  4. The waste is only % sulphur by mass, yet every kilogram burnt releases about 10 g of SO2, because the two oxygen atoms double the mass.

Trap: stopping at the mass of sulphur, g, is outside the key; the question asks for SO2, which weighs twice the sulphur.

Where this shows up in industry

Waste-to-energy and incineration plants use the ultimate analysis of the waste (C, H, O, N, S and moisture) to estimate air demand, calorific value and acid gas loads, which in turn size the lime or sorbent dosing of the flue gas cleaning system.

GATE 2025 · CE1 · Q.46MSQ · 2 marksMunicipal solid waste

OFMSW (315 kg/m3, 30% water) mixed with sludge (700 kg/m3, 70% water) to 40% water: sludge per kg and density

Organic fraction of municipal solid waste (OFMSW) with bulk density of 315 kg/m3 and water content of 30% is mixed with municipal sludge of bulk density 700 kg/m3 and water content of 70%, such that the water content of the mixture is 40%. The amount (in kg) of sludge to be mixed per kg of OFMSW (rounded off to 2 decimal places) and the density of the mixture (in kg/m3) (rounded off to the nearest integer) are calculated. Which of the following options is/are true:

  1. (A)0.33 kg of sludge added per kg of OFMSW
  2. (B)Density of the mixture is 365 kg/m3
  3. (C)0.66 kg of sludge added per kg of OFMSW
  4. (D)Density of the mixture is 450 kg/m3

Answer: (A) and (B) Official key: A;B

  1. Take 1 kg of OFMSW (0.30 kg water) and kg of sludge ( kg water). Water content is on a wet-mass basis: .
  2. , so , i.e. 0.33 kg per kg, (A) true; (C) false.
  3. Volumes add, masses add: for kg.
  4. Density , so 365 kg/m3, (B) true; (D) false.
  5. Answer: (A) and (B).

Trap: averaging the two densities by mass gives kg/m3, which is not 365; bulk densities must be combined through volumes, because it is the volumes of the two materials that add up.

Where this shows up in industry

Composting and bio-methanation plants blend wet sewage sludge with drier organic waste in exactly this way to bring the feed to a workable moisture content; the Solid Waste Management Rules 2016 require biodegradable waste to be processed by such methods rather than landfilled.

From GATE prep to a water supply and environmental engineering career

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.