Stadium seating sightline calculator: C-value, riser height and rake for every row

Each seat sees the touchline over the head in front when its sightline clears that spectator's eye by the C-value: FIFA prefers 90 mm and calls 120 mm optimal. A tier whose first eye is 8 m from the touchline and 1.6 m above it, with 800 mm rows and C = 90 mm, needs risers from 260 mm at row 2 to 380 mm at row 30, at most 25.4° steep. Change any number to design your own tier, count the seats and copy the profile into Dynamo.

Green Guide (Guide to Safety at Sports Grounds, 5th ed. 2008) Diagram 12.1, 12.11-12.16 · FIFA Football Stadiums Guidelines · Dynamo node names from the Dynamo Primer and Dictionary · checked against an independent solution (21,572 checks at build) · Updated 24 Nov 2026

Where the first row sits, how deep each row is and what C-value you want: what riser does every row need, and how steep does the tier get?

Point of focus: the nearest touchline for football or rugby, the outside lane of a running track, or the edge of the court (Green Guide Diagram 12.1). The sample is a made-up lower tier: first eye 8.0 m out and 1.6 m up, 800 mm rows (FIFA's minimum tread) and C = 90 mm (FIFA's preferred value). Eye height above the tread only places the treads in the drawing and the tread levels; no free standard we read states it, and it never changes a C-value.

Risers260 to 380 mmrow 2 to row 30
Steepest row25.4°average 22.6°, limit 34°
Tier rise9.68 mover 23.2 m of rows
Section, to scale: 30 rows, 9.68 m from first to last eye34° limitpoint of focusRow 1Row 2Row 3Row 4Row 5Row 6Row 7Row 8Row 9Row 10Row 11Row 12Row 13Row 14Row 15Row 16Row 17Row 18Row 19Row 20Row 21Row 22Row 23Row 24Row 25Row 26Row 27Row 28Row 29Row 30Row 12: riser 325 mm, C = 94.0 mm over row 11, rake 22.1°tap a row · red eye: C short · amber: too steep
  • Every row reaches C = 90 mm after rounding: lowest 90.0 mm, highest 94.5 mm.
  • No row is steeper than 34°.
  • Radial gangway with 2 steps a row: steps up to 190.0 mm high and 400 mm deep, against at most 190 mm and at least 280 mm.
RowD (m)R (m)Riser (mm)C (mm)Rake (°)Tread (m)
18.001.600–––0.400
28.801.86026090.918.00.660
39.602.13027092.518.60.930
410.402.40527590.019.01.205
511.202.69028592.919.61.490
612.002.98029091.319.91.780
712.803.27529590.320.22.075
813.603.58030594.420.92.380
914.403.89031093.921.22.690
1015.204.20531593.721.53.005
1116.004.52532093.821.83.325
1216.804.85032594.022.13.650
1317.605.18033094.522.43.980
1418.405.51033090.422.44.310
1519.205.84533591.522.74.645
1620.006.18534092.623.04.985
1720.806.53034593.823.35.330
1821.606.87534590.423.35.675
1922.407.22535092.023.66.025
2023.207.58035593.623.96.380
2124.007.93535590.523.96.735
2224.808.29536092.424.27.095
2325.608.66036594.424.57.460
2426.409.02536591.524.57.825
2527.209.39537093.724.88.195
2628.009.76537091.024.88.565
2728.8010.14037593.325.18.940
2829.6010.51537590.825.19.315
2930.4010.89538093.325.49.695
3031.2011.27538090.925.410.075

How do you calculate a stadium sightline (C-value)?

The Green Guide measures everything from the point of focus, usually the nearest touchline. For a spectator whose eye is from it horizontally and above it, with row depth and a riser to the row behind, the sightline of the person behind clears this eye by:

To design a tier you choose and solve for the riser, row by row, using and of the row in front:

For the sample ( mm, mm, mm, mm), rounding each riser up to 5 mm:

Rounding up keeps every C at or above the target; rounding down would leave rows short. Without rounding every row gets exactly 90 mm and the last eye ends at 11.150 m instead of 11.275 m. The risers grow up the tier because each row is further from the pitch and must look down more steeply past the head in front; the Green Guide notes that larger tiers often need "riser heights which increase incrementally from the front to the rear".

What C-value should a stadium use?

FIFA's Football Stadiums Guidelines: "The preferred C-value for stadiums is C=90, rising to C=120", "A C-value of 120mm is regarded as optimal" and "A minimum recommended C-value is C=60", allowed in specific areas but "avoided in lower tiers wherever possible". FIFA puts the eye-to-top-of-head distance at 120 mm. The Green Guide (fifth edition, the free copy we could read; the sixth edition of 2018 is sold by the SGSA) says the recommended value "varies according to the sport, as does the choice of focal point": the nearest touchline for football or rugby, further infield for cricket.

We found no Indian document, free to read, that states a stadium C-value, rake limit or seats per row; the National Building Code 2016 is a paid BIS publication and we did not read it. Indian stadium designers commonly work to FIFA and the Green Guide; check your local authority's rules.

What is the maximum rake for stadium seating?

The Green Guide: "for seated areas the angle can be as steep as 34°", standing areas no more than 25°, and radial gangway steps with goings of at least 280 mm and risers of at most 190 mm. FIFA leaves the number to "national regulations" and lists the levers: a higher C, a front row raised above the pitch, or a front row closer to the pitch all steepen the tier. Move the sample's first eye from 8 m to 3 m and the steepest row goes from 25.4° to 42.4°, 29 rows over 34°.

How many seats fit in a stadium bowl?

Each row's seat line follows the focus line at the row's eye distance . For a rectangle of with corner radius , offset by , the straights keep their length and the corners grow:

Round the 105 × 68 m sample pitch, the front row is 396.3 m long and the back row 542.0 m. For an oval we use Ramanujan's second approximation for an ellipse with semi-axes and :

Seats come from the row length less radial gangways of width , split into blocks of seats of width ; is the fewest blocks that keep the longest row at 28 seats or fewer (Green Guide 12.16 and FIFA):

That gives the sample 25,060 seats. As a rough egress check, all of them leaving down the radial gangways at the Green Guide's 66 people a metre a minute on steps:

Over the 8-minute normal egress time, so a real tier this size needs vomitories or lateral gangways. Capacity in practice is also set by the safety certificate's (P) and (S) factors, not by the seat count.

How do you model a parametric stadium in Dynamo?

Calculate the section first, then let Dynamo draw it. Tab 4 writes the section as x and z lists for a Code Block and as a CSV; tab 3's plan becomes the path. The node names below are as the Dynamo Primer and Dynamo Dictionary spell them.

  1. Copy the Code Block from this tab into a Code Block node, or save the CSV and read it with Data.ImportCSV (List.Transpose turns its rows into columns).
  2. Point.ByCoordinates(x, 0, z) makes the stepped section points; PolyCurve.ByPoints joins them into the row profile.
  3. Draw the focus line: Rectangle.ByWidthLength for a pitch, or Ellipse.ByOriginRadii for an oval track, centred on the origin.
  4. Offset that curve once for each row with Curve.Offset, using the eye distances eyeD (check the side: a negative distance offsets the other way).
  5. Lift each offset curve to its tread level with Geometry.Translate along Vector.ZAxis, using treadZ.
  6. Surface.ByLoft through the lifted curves gives the raked bowl surface; for true steps, Surface.BySweep the profile along the focus line.
  7. Put Number Slider nodes on C, row depth and rows, and re-run the calculator when you change them: the risers change with every input.

Ranges trip people up. a..b..#n ends in a count, a..b..c in a step, and a..#n..c is n values c apart. For 10 levels of 4 m, 0..#10..4 gives the 10 floor heights 0 to 36 m and 0..90..#10 gives 10 rotations 10° apart, but 0..10..4, the levels typed without the #, gives 0, 4, 8: 3 values. Tab 6 tells you which you typed.

Why the class tower is not a stadium

The course's high-rise example makes a rectangle per level and turns each one by

so 10 levels from 0° to 90° turn 10° a level, and a loft through them gives a twisted shell 36 m tall. That shell has no rows, no risers and no point of focus. A stadium's geometry comes from the sightline: the riser of every row follows from the row in front, the C-value and the row depth, which is why tab 1 starts there.

What 489 public reports did (as of 24 Nov 2026)

We read the text of the 489 public Skill-Lync reports of the Dynamo parametric stadium project, as of 24 Nov 2026, n = 489. 24 are image-only (under 400 characters of text), which leaves 465; many of the rest are mostly screenshots, so every count is a floor. The links are examples.

So 370 of the 429 reports with written stadium steps built the twisted tower from the class example, 2 described seating rows and none mentioned a sightline, C-value, riser or rake. 123 share four or more long sentences word for word with ten or more other reports. One slip we could count from text: at least 6 write the levels range as 0..levels..floorheight, without the #, which makes the level count an end value (report 1report 2report 3). With 10 levels of 4 m that gives 3 values, not 10. Tab 6 catches it.

These are first-party counts, a starting point rather than a measure of ability.

How we checked the calculator

An independent Python script, scripts/verify/stadium_sightline.py, rebuilds every row, riser, C-value, rake, perimeter, seat count, range, tower corner and verdict with its own code. This page refuses to build if the browser code differs from it in any of 21,572 numbers or verdicts (192 cases, 28 hand checks in the script, including the three rows worked above). The cases include one row, C = 0, a 1 mm row depth, a first row 0.3 m from the pitch, 400 rows, no rounding and rounding to 1, 2.5, 5, 10 and 25 mm, both plan shapes, a stand on part of the perimeter, one-level towers, ranges with step against count, and typed rows in metres, millimetres and mixed. Two deliberate bugs, a C formula with D and D + T swapped and an oval that does not grow with the rows, each make the build fail.

What this calculator does not cover

  • Curved and multi-tier bowls. One tier, one point of focus. Upper tiers over a lower one need the high-ball line FIFA mentions and a structural overhang check.
  • Standing, wheelchair and barrier sightlines. Standing is checked over every second row; wheelchair positions need super risers (Green Guide 12.4). Not modelled.
  • Safe capacity. The seat count is geometry. A stadium's certified capacity comes from (P) and (S) factors, exits and the egress and evacuation times.
  • Local rules. Check the codes your authority applies; they can set a different rake, gangway or seat rule.
Learn BIM and Dynamo in Revit

Conceptual mass, the sinusoidal curve and a parametric stadium in Dynamo are a project in Skill-Lync's BIM in AEC Industry using Revit course.

Frequently asked questions

What is a C-value in stadium design?

The C-value is how far a spectator's sightline to the pitch passes above the eye of the person in front, in millimetres. The Green Guide calculates it from the eye distance D, eye height R, row depth T and riser N. FIFA puts the eye-to-top-of-head distance at 120 mm, so C = 120 clears a full head.

How do you calculate stadium sightlines?

Pick the point of focus, usually the nearest touchline. For each row, the riser N = (R + C)(D + T)/D − R, where D and R are the eye distance and height of the row in front. Add N to R, step D back by the row depth, and repeat for every row up the tier.

What C-value is recommended for a stadium?

FIFA's stadium guidelines prefer C = 90 mm, rising to 120 mm, which they call optimal, with 60 mm the minimum in specific areas and avoided in lower tiers. The Green Guide says the value varies with the sport and the focal point. We found no Indian document that states a C-value.

What is the maximum rake for stadium seating?

The Green Guide (fifth edition) allows seated areas as steep as 34° and standing areas no more than 25°; radial gangway steps need risers of at most 190 mm and goings of at least 280 mm. FIFA leaves the maximum rake to national regulations. A higher C-value always makes the tier steeper.

How do you calculate riser height for tiered seating?

Use N = (R + C)(D + T)/D − R row by row, then round up, never down, so C stays at or above the target. For a first eye 8 m out and 1.6 m up, 800 mm rows and C = 90 mm, the risers grow from 260 mm at row 2 to 380 mm at row 30.

How do you model a stadium in Dynamo?

Compute the row profile first, then paste it into a Code Block as x and z lists and join the points with PolyCurve.ByPoints. Draw the pitch with Rectangle.ByWidthLength or Ellipse.ByOriginRadii, offset it for each row with Curve.Offset, lift each curve with Geometry.Translate, then Surface.ByLoft or Surface.BySweep the result.

How many seats fit in a stadium bowl?

Divide each row's length by the seat width after taking out the radial gangways, then add the rows. With at most 28 seats between gangways, 500 mm seats and 1.2 m gangways, the sample's 30 rows round a 105 × 68 m pitch hold 25,060 seats, with 35 gangways.

What is the difference between C-value and every-second-row seating?

C-values for seats are calculated for every row, so each spectator sees over the head directly in front. For standing spectators the Green Guide and FIFA allow the calculation over every second row, because people standing can shift their position. Seats with barriers are designed seated, then checked standing.

Related on Skill-Lync

Sources

  • Guide to Safety at Sports Grounds (Green Guide), fifth edition, 2008 (Crown copyright; free copy hosted by JESIP, read 24 Nov 2026): 12.3 and Diagram 12.1 (C formula, point of focus), 12.9 (30 m travel, 1.1 m / 1.2 m gangways), 12.11 (34°, 280 mm goings, 190 mm risers), 12.13 (seat width 460 / 500 mm, row depth 700 / 800 mm), 12.16 (14 and 28 seats), 10.6 (66 and 82 people a metre a minute), 10.7 (8 minutes), 11 and 13.11 (34° seated, 25° standing, every second tread for standing), Annex E.1. The sixth edition (SGSA, 2018) was not read.
  • FIFA, Football Stadiums Guidelines: 2.3 Stadium Bowl (C = 60 / 90 / 120, 120 mm eye to top of head, rake levers, national regulations) and 5.2 Seating and Standing Areas (800 mm treads, 500 mm seat centres, 28 seats between gangways, every other row for standing).
  • dynamobim.org, "Dynamo sequences and ranges"; Dynamo Primer, code block shorthand and Index of Nodes; Dynamo Dictionary node data (DynamoDS/DynamoDictionary): Data.ImportCSV, Curve.Offset, Ellipse.ByOriginRadii, Surface.BySweep, Vector.ZAxis.
  • Ramanujan's second approximation for the perimeter of an ellipse (our choice of method for the oval plan).
Free counselling

From a Dynamo exercise to a stadium you can defend.

BIM roles want engineers who can drive Revit and Dynamo from real design rules. A Skill-Lync counsellor can map the Revit or BIM course that fits your background.

Talk to a Revit course counsellor

Free. We call you back, usually the same day.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.