Black FridayUpgrade your career this Black Friday. Get up to ₹60,000 Scholarship on IIT programsUp to ₹60K Black Friday Scholarship63 seats leftOffer ends Fri, 27 Nov, 11:59 pm IST.

Black Friday Scholarship – IIT Jammu & IIT Roorkee

The best Black Friday deal isn't a gadget. It's your next career move.

Get up to ₹60,000 Black Friday Scholarship on our PG programs with IIT Jammu and iHUB DivyaSampark, IIT Roorkee. IIT certification, 12 live sessions with IIT faculty and 100% placement assistance.

Only 63 seats left. Offer ends Fri, 27 Nov, 11:59 pm IST

3,905 engineers placed since 2019 · 1,276 hiring companies

By submitting you agree to our Terms and Privacy Policy.

Your free demo class is requested

Browse courses

RC slab design calculator (IS 456:2000 one-way, two-way and cantilever slabs)

A 3.6 m x 4.5 m corner room with two adjacent edges discontinuous is a two-way slab (ly/lx = 1.24): IS 456 Table 26 case 4. At D = 125 mm, M20 and Fe 500, the short-span moment is 5.86 kN m/m at mid-span and 7.80 over the continuous edges. Short-span bars: 10 mm at 300 mm.

At mid-span the 0.12 % minimum (150 mm²/m) is more than the moment needs, and the 3d or 300 mm spacing limit sets the bars. Span/depth needs d of 81 mm; 100 is provided. Run any panel below, free.

IS 456:2000 · IS 875 (Part 2) · 36,161 build-time checks against an independent script · Updated 24 Nov 2026

Panel

Edges (continuous = slab carries on over the support)

Section and materials

Loads (characteristic; γf = 1.5, Table 18)

Your TSD or hand design (bar dia @ spacing, e.g. 10@175)

10 mm at 175 mm is the slab steel most often stated in the TSD reports. Steel required is worked out with the bar size set above.

Slab typetwo-waycase 4, ly/lx 1.24
DepthD 125 mmdx 100, dy 90 mm; least 110
Verdictpassesflexure, shear, L/d
long edge Along edge Bshort Ashort Bmiddle strips 3/4fullhalfhalf10 @ 300short span10 @ 270lxly 4.59 m3.70 mcontinuousdiscontinuoustorsion mat
WhereM kN m/mAst reqBarsAst prov
Short span, bottom, middle strip5.8615010 @ 300262
Long span, bottom, middle strip4.4015010 @ 270291
Short span, top, at continuous long edges7.8018810 @ 300262
Long span, top, at continuous short edges5.9115810 @ 270291
Short span, top, at discontinuous long edges (D-1.6)-13110 @ 300262
Long span, top, at discontinuous short edges (D-1.6)-14510 @ 270291
Edge strips, both ways (D-1.7, minimum steel)-15010 @ 450175

    How do you design a two-way slab as per IS 456?

    Annex D covers slabs on four supports carrying uniform load. Find the effective spans (clause 22.2), the factored load w and the ratio ly/lx. If it is over 2 the slab is one-way (D-1.11, as amended). Otherwise read the coefficients for the panel's edge conditions from Table 26 (corners held down) or Table 27 (simply supported, corners free to lift), and work out the moments per metre width:

    Both use lx², the short span. For the corner room, with the 230 mm walls as supports and d = 100 mm for the short-span bars (90 mm for the long-span bars that sit on them):

    The moments apply to the middle strip, three-quarters of each span; the edge strips (one-eighth each side) take minimum steel (D-1.2, D-1.3, D-1.7). Steel comes from Annex G-1.1:

    The short-span mid-span moment needs 140 mm²/m, under the 0.12 % minimum of 0.0012 x 1000 x 125 = 150 mm²/m (26.5.2.1). 10 mm bars would be spaced at 524 mm, but 26.3.3(b) caps main bars at 3d or 300 mm, so 300 mm. Over the continuous edges 188 mm²/m is needed: 10 mm at 300 mm. Long span: 270 mm bottom, 270 mm top. Bars must not exceed D/8 = 15.6 mm (26.5.2.2).

    Shear is checked at d from the support face with V = w lx/2 per metre of the long edge (the 45° load share of clause 24.5 and Fig. 7): τv = 0.161 N/mm² against k τc = 1.30 x 0.28 = 0.364 N/mm² (40.2.1.1, with Table 19 for the lowest steel row, as the NPTEL examples do). Slabs this thin rarely need shear steel.

    How is slab deflection checked by span/depth ratio?

    Clause 23.2.1 accepts a slab whose span over effective depth stays under a basic ratio (7 cantilever, 20 simply supported, 26 continuous, for spans up to 10 m) times kt from Fig. 4 for the tension steel, and kc from Fig. 5 for compression steel (1.0 here). Note 1 of 24.1 says to use the short span of a two-way slab.

    For a span continuous at one end and discontinuous at the other, the code gives no basic ratio. This tool takes 23, the mean of 20 and 26, as the NPTEL one-way example does. For the corner room the short span has one discontinuous long edge, so: basic 23, pt = 0.26 %, fs = 155 N/mm², kt = 1.99, and d ≥ 3,700 / (23 x 1.99) = 81 mm. Light steel at low stress pushes kt to its cap of 2.0, which is why thin slabs pass.

    Fig. 4 is a chart. This page uses a digitised copy: we read the five fs curves off the code's page at 300 dpi and interpolate between them. A formula often quoted for Fig. 4 was off by up to 19 % against those readings at low steel with fs = 290 (Fe 500), so it is not used. Fe 550 (fs up to 319 N/mm²) extrapolates the 240 to 290 curves.

    Note 2 of 24.1 gives a shortcut for two-way slabs with short spans up to 3.5 m and live load up to 3 kN/m²: span over overall depth 35 simply supported and 40 continuous with mild steel, times 0.8 for Fe 415. It does not cover Fe 500 or Fe 550. The NPTEL example takes the mean, 30, for a panel with two discontinuous edges; this tool does the same and shows it only for Fe 415.

    What is the difference between a one-way and a two-way slab?

    A one-way slab bends in one direction: it rests on two opposite supports, or on four with the long span more than twice the short one. Its main bars run across the short span and distribution bars the other way. A two-way slab on four supports with ly/lx up to 2 bends both ways, so both directions carry moment and need main bars.

    The same 3.6 x 4.5 m room, D = 125 mm, M20, Fe 500, designed both ways (the one-way version spans the 3.6 m between its long edges as an end span, Table 12):

    QuantityTwo-way (Table 26 case 4)One-way (Table 12 end span)
    Short-span mid-span moment5.86 kN m/m11.17 kN m/m
    Short-span support moment7.80 kN m/m13.03 kN m/m
    Long-span moment4.40 (+), 5.91 (−) kN m/mnone (distribution steel only)
    Short-span bottom steel150 mm²/m: 10 @ 300276 mm²/m: 10 @ 280
    Short-span top steel188 mm²/m: 10 @ 300326 mm²/m: 10 @ 240
    Corner torsion steel3 corners (D-1.8, D-1.9)none
    d needed for span/depth81 mm125 mm

    Designed one-way, the short span takes the whole load: its moments are 90 % and 67 % higher, but the long direction then gets no moment steel at the continuous short edge, where the real slab does develop 5.91 kN m/m and cracks. Use the type the ratio gives.

    What is IS 456 Table 26 (two-way slab moment coefficients)?

    Table 26 gives αx and αy for nine panel types with corners held down. The short-span coefficient changes with ly/lx; the long-span one does not. The table below is the lib's own data; the calculator interpolates linearly between columns (the code does not say how to interpolate; linear is the usual practice).

    CaseMoment11.11.21.31.41.51.752αy
    1Interior panel: − at continuous edge0.0320.0370.0430.0470.0510.0530.0600.0650.032
    + at mid-span0.0240.0280.0320.0360.0390.0410.0450.0490.024
    2One short edge discontinuous: − at continuous edge0.0370.0430.0480.0510.0550.0570.0640.0680.037
    + at mid-span0.0280.0320.0360.0390.0410.0440.0480.0520.028
    3One long edge discontinuous: − at continuous edge0.0370.0440.0520.0570.0630.0670.0770.0850.037
    + at mid-span0.0280.0330.0390.0440.0470.0510.0590.0650.028
    4Two adjacent edges discontinuous: − at continuous edge0.0470.0530.0600.0650.0710.0750.0840.0910.047
    + at mid-span0.0350.0400.0450.0490.0530.0560.0630.0690.035
    5Two short edges discontinuous: − at continuous edge0.0450.0490.0520.0560.0590.0600.0650.069-
    + at mid-span0.0350.0370.0400.0430.0440.0450.0490.0520.035
    6Two long edges discontinuous: − at continuous edge--------0.045
    + at mid-span0.0350.0430.0510.0570.0630.0680.0800.0880.035
    7Three edges discontinuous (one long edge continuous): − at continuous edge0.0570.0640.0710.0760.0800.0840.0910.097-
    + at mid-span0.0430.0480.0530.0570.0600.0640.0690.0730.043
    8Three edges discontinuous (one short edge continuous): − at continuous edge--------0.057
    + at mid-span0.0430.0510.0590.0650.0710.0760.0870.0960.043
    9Four edges discontinuous: − at continuous edge---------
    + at mid-span0.0560.0640.0720.0790.0850.0890.1000.1070.056

    The print labels case 2 "One Short Edge Continuous". Its numbers belong to one short edge discontinuous: it has support moments in both directions, which needs both long edges and at least one short edge continuous, and its coefficients sit between case 1 (all continuous) and case 4. The tool reads it that way. The note to IS 456 24.4 names Johansen's yield-line theory as the most commonly used limit-state method for two-way slabs. We could not read a public source that gives the formula behind Table 26's coefficients, so the table is checked for sense (rows rise with the ratio, support above span values) but not re-derived here.

    Table 27 (simply supported, corners free) follows the Rankine-Grashoff idea, which the NPTEL lesson names: share the load between two crossing strips so they deflect equally at the centre.

    ly/lx11.11.21.31.41.51.7522.53
    αx0.0620.0740.0840.0930.0990.1040.1130.1180.1220.124
    αy0.0620.0610.0590.0550.0510.0460.0370.0290.0200.014
    formula αx0.06250.07430.08430.09260.09920.10440.11300.11760.12190.1235
    formula αy0.06250.06140.05860.05480.05060.04640.03690.02940.01950.0137

    19 of the 20 printed values are the formula rounded to three decimals (at 1.0, 0.0625 is printed 0.062). The exception is αx at 3.0: the formula gives 0.1235, printed 0.124. The build check holds the table to this.

    For one-way continuous slabs (24.2), Table 12 gives moments as a fraction of the total load times the span and Table 13 the shears, for three or more spans differing by up to 15 % of the longest (22.5.1):

    LoadEnd span, middleInterior span, middleNext to end supportOther interior supports
    Dead and fixed imposed+1/12+1/16−1/10−1/12
    Imposed, not fixed+1/10+1/12−1/9−1/9
    Shear: dead / imposedend support 0.4 / 0.45-outer 0.6 / 0.6, inner 0.55 / 0.60.5 / 0.6

    The tool uses the end-span column for a slab continuous at one end and the interior column (with "other interior supports") for one continuous at both; if your spans or loads fall outside 22.5.1, analyse the continuous slab instead.

    How thick should a slab be?

    The least overall depth that passes flexure, shear, span/depth (with the steel it needs) and D/8 for 10 mm bars, from this calculator: M20, Fe 500, cover 20 mm, finish 1.0 and live load 2.0 kN/m², 230 mm supports, clear spans, two-way panels with ly = 1.25 lx. Fe 415 in brackets.

    Clear short spanOne-way, simply supportedOne-way, continuous both endsTwo-way interior (case 1)Two-way corner (case 4)Two-way, four edges discontinuous, corners held (case 9)
    3.0 m140 (130)100 (100)100 (100)100 (100)110 (110)
    3.5 m165 (150)115 (115)100 (100)105 (105)135 (135)
    4.0 m185 (170)140 (135)105 (105)120 (120)160 (155)
    4.5 m205 (190)155 (145)120 (120)145 (145)190 (175)
    5.0 m230 (215)175 (160)135 (135)165 (160)210 (190)
    5.5 m250 (235)190 (175)150 (150)190 (175)225 (210)
    6.0 m270 (255)205 (190)170 (165)210 (190)250 (225)

    Cantilever balconies (live 3.0 kN/m² plus 1.5 kN/m at the edge, M25, moderate exposure, 30 mm cover): 0.9 m: 115 mm; 1.2 m: 160 mm; 1.5 m: 195 mm; 1.8 m: 230 mm. With the 24.1 Note 2 shortcut (Fe 415, two-way, live load up to 3 kN/m²), a 3.0 m short span needs D of 107 mm simply supported and 94 mm continuous; 3.5 m needs 125 and 109 mm, against 110 and 100 mm (3.0 m) and 135 and 100 mm (3.5 m) from 23.2.1 in the Fe 415 columns above.

    These are code minimums for one load case. Fire resistance adds its own cover: Table 16A asks 20 mm nominal cover for a 1 hour slab and 25 mm for a 1.5 hour simply supported slab.

    How much torsion steel goes at the corners of a two-way slab?

    When corners are held down, they try to lift and twist. D-1.8 asks for torsion steel at any corner where the slab is simply supported on both edges: top and bottom mats of two layers each, parallel to the sides, extending one-fifth of the short span from the edges, each layer three-quarters of the steel required for the maximum mid-span moment. D-1.9 halves it at a corner with one continuous edge; D-1.10 drops it where both edges are continuous.

    For the corner room: 0.75 x 150 = 113 mm²/m per layer at the corner of the two discontinuous edges, half that at the two corners with one continuous edge, over 0.74 m x 0.74 m. 10 mm bars at 300 mm in each layer satisfy it. Simply supported slabs designed with Table 27 have no torsion steel: their corners are assumed free to lift, and D-2.1.1 instead runs at least half the mid-span steel to the supports.

    What does a slab "check panel" in Tekla Structural Designer flag, and why?

    Skill-Lync's Tekla Structural Designer course has an assignment to design the slab and foundation of an RC residential building. TSD's slab check compares the bars you set with what its design code needs. The numbers above say which checks fail first:

    • Span/depth (deflection). The commonest failure for a long thin panel. More depth, a secondary beam that halves lx, or more steel (lower fs, higher kt) fixes it; the Thickness tab shows which.
    • Steel below the minimum or below the moment's need. In a thin slab 0.12 % of bD usually governs over the mid-span moment.
    • Bar spacing over 3d or 300 mm. With light steel the spacing rule, not the area, sets the bars: 100 mm effective depth caps spacing at 300 mm.
    • Shear. Rare in slabs; it shows up with heavy loads or short thick cantilevers.
    • Torsion steel and the slab type. A two-way panel needs corner mats at discontinuous corners; designing it one-way leaves the long direction without moment steel.

    As of 24 Nov 2026, we read the text of the 62 public reports of this assignment (7 are image-only, leaving 55). 46 of 55 run the check panel and 49 fix a failure by editing bar size, spacing or other properties. None shows a hand calculation of a slab moment, steel area or thickness, and none names Annex D or Table 26. 9 state a slab depth (150 mm in 4, 200 mm in 5), and 8 name span/depth as a check. The question gives no spans or loads, so the reports cannot be checked against one building; the Check tab rechecks yours.

    Worked example: does the calculator match a published solution?

    NPTEL's Design of Reinforced Concrete Structures (IIT Kharagpur, Module 8) solves three slabs to IS 456. The build reproduces them:

    1. Lesson 19, Problem 8.2: corner panel, 4 m x 6 m effective spans, two adjacent edges discontinuous, D 160 mm, d 135 mm, M20, Fe 415, factored live load 8 and finish 1 kN/m². w = 15.50 kN/m², ly/lx = 1.50, Mx = 18.60 (−) and 13.89 (+), My = 11.66 and 8.68 kN m/m (printed 18.6, 13.89, 11.66, 8.68); V = w lx/2 = 31.0 kN/m (31); k = 1.28, k τc = 0.3584 N/mm² (1.28, 0.3584); minimum steel 192 mm²/m (192); torsion strips 4000/5 = 800 mm (800). NPTEL takes τv at the face, 31/135 = 0.229; this tool takes it at d, 0.214. NPTEL picks bars from SP 16 tables; the tool solves Annex G.
    2. Lesson 19, Q.6: simply supported, corners free, 4.2 m x 5.88 m, D 175 mm, d 150 mm, factored live load 6. Table 27 at 1.4: Mx = 24.558 and My = 12.651 kN m/m, V = 29.531 kN/m, k τc = 1.25 x 0.28 = 0.35 (printed 24.558, 12.651, 29.531, 0.35).
    3. Lesson 18, Problem 8.1: one-way continuous slab, d 115 mm, M20, Fe 415. Annex G for 12.825 and 10.6875 kN m/m: 328.34 and 270.615 mm²/m, the printed values to the last digit. (The lesson applies 1/12 and 1/10 to the whole load; Table 12 splits dead and imposed load, which this tool does.)

    Lesson 18 reads kt = 1.18 off Fig. 4 for pt = 0.5 % and fs = 240 N/mm². Our readings of the same chart give 1.23 there, and so does the formula often quoted for it; chart readings by eye differ by a few percent.

    How we checked the calculator

    An independent Python script, scripts/verify/slab.py, types Tables 26, 27, 12, 13, the 40.2.1.1 k values, Table 19 and the Fig. 4 readings again from the code's pages and re-solves every preset and 331 more panels (all nine Table 26 cases and the Table 27 case across ratios 1 to 2, one-way spans, cantilevers, M20 to M40, Fe 415 to Fe 550) with its own effective spans, Annex G quadratic, bar rules, shear, deflection and depth search. It checks the tables for sense (rows rise with ly/lx, support above span coefficients, Table 27 against the strip formula) and the three NPTEL examples. This page then runs the browser code on every case (36,161 comparisons) and does not build if any value differs by more than one part in a billion. Two deliberate errors (one Table 26 cell swapped; the slab k factor dropped) each failed both the script and the build.

    What the method ignores. Annex D assumes rectangular panels under uniform load. Openings, point and line loads (other than the cantilever's edge load), flat slabs (clause 31), and continuous panels with very unequal neighbours (24.4.1 asks for a moment adjustment) are outside it. Serviceability is by span/depth only, not a deflection or crack-width calculation (Annex C, Annex F). Shear uses the lowest Table 19 value, which is conservative. Fire cover (Table 16A) and fire size limits are not checked.

    Learn RC design

    Slab, beam, column and foundation design of RC buildings with Tekla Structural Designer, ETABS and hand checks to IS 456 is taught in Skill-Lync's structural design programs.

    Frequently asked questions

    What is the difference between one-way and two-way slab?

    A slab supported on two opposite edges, or on four edges with the long span more than twice the short span, bends in one direction and is one-way. With ly/lx up to 2 on four supports it bends both ways and is two-way, designed with IS 456 Annex D. A 3.6 x 4.5 m room is two-way.

    How do you calculate slab thickness as per IS 456?

    Clause 23.2.1 limits span over effective depth: 20 simply supported, 26 continuous, 7 cantilever, times kt from Fig. 4 for the steel provided. Use the short span of a two-way slab. A 3.6 x 4.5 m corner panel with Fe 500 needs d of about 81 mm, so D of 110 mm with 20 mm cover.

    What is the minimum reinforcement in a slab as per IS 456?

    Clause 26.5.2.1: 0.12 percent of the gross cross-section in either direction with high strength deformed bars (0.15 percent with mild steel). For a 125 mm slab that is 150 mm² per metre width, for example 8 mm bars at 330 mm, but the 3d spacing rule may need closer bars.

    What is the maximum spacing of bars in a slab?

    Clause 26.3.3(b): main bars not more than three times the effective depth or 300 mm, whichever is smaller; distribution bars not more than five times the effective depth or 450 mm. Clause 43.1 says meeting the spacing rules generally controls flexural cracking without a crack width calculation.

    How are two-way slab moments calculated using Table 26?

    Pick the panel case from which edges are continuous, read the short-span coefficient αx at ly/lx and the long-span coefficient αy, and multiply each by the factored load w and the square of the short span. The moments apply to the middle three-quarters of each span; edge strips take minimum steel.

    What is torsion reinforcement in a two-way slab?

    At a corner where both edges are discontinuous, IS 456 D-1.8 asks for top and bottom mats, each of two layers, over one-fifth of the short span, each layer three-quarters of the steel for the maximum mid-span moment. A corner with one continuous edge takes half (D-1.9); two continuous edges need none.

    What live load is used for a residential slab?

    IS 875 (Part 2) Table 1 gives 2.0 kN/m² for all rooms, kitchens, toilets and bathrooms of dwelling houses, 3.0 kN/m² for corridors, passages, staircases and store rooms, and 3.0 kN/m² for balconies with 1.5 kN per metre run at the outer edge. Add floor finish and self weight at 25 kN/m³.

    Is this slab design calculator free?

    Yes. It runs in your browser with no sign-up. Every number is recomputed at build time against an independent Python script that re-types the IS 456 tables and reproduces three NPTEL worked examples (36,161 comparisons), and the page does not build if any value differs.

    Related on Skill-Lync

    Sources

    • Bureau of Indian Standards, IS 456:2000 Plain and Reinforced Concrete: Code of Practice with Amendment 1 (public copy, law.resource.org): 19.2.1, 22.2, 22.5.1, Tables 12 and 13, 23.2.1 and Fig. 4, 24.1 Notes 1 and 2, 24.4, 24.5, 26.3.3, 26.4.2 and Table 16, Table 5, 26.5.2.1, 26.5.2.2, Table 18, 38.1, 40.2.1.1, Table 19, 43.1, Annex D (D-1.0 to D-1.11, D-2, Tables 26 and 27), Annex G.
    • IS 875 (Part 2):1987 Imposed loads (law.resource.org): Table 1, i) residential buildings, a) dwelling houses.
    • NPTEL, IIT Kharagpur, Design of Reinforced Concrete Structures (Version 2 CE), Module 8 Lessons 18 (one-way slabs) and 19 (two-way slabs), archive.nptel.ac.in.
    • Skill-Lync, the 62 public student reports of "To Design slab and foundation for an RC residential building using TSD", read 24 Nov 2026.
    Free counselling

    From a green check panel to slab design you can defend.

    Residential and commercial RC buildings are where most structural design jobs in India start. A Skill-Lync counsellor can map the course that fits the role you want.

    Talk to a structural design course counsellor

    Free. We call you back, usually the same day.

    By submitting you agree to our Terms and Privacy Policy.

    Talk to a career counsellor

    Talk to a career counsellor

    Free 20-minute call. We'll map the right course to where you want to work.

    By submitting you agree to our Terms and Privacy Policy.