Channel flow calculator (parallel plates, entry length, GCI)
A 1 Pa drop across a 10 mm × 0.1 m air channel gives a mean velocity of about 0.94 m/s, not the 4.5 m/s of the Poiseuille formula: the flow is still developing at the outlet. This calculator works that out for any channel, checks the formula's validity (entrance length, Reynolds number), does fully developed plates and rectangular ducts both ways, counts your mesh cells, and turns three grids into a grid convergence index. Free, no sign-up, runs in your browser.
Shah & London 1978 (parallel plates) · Chen 1973 · Celik et al. 2008 (ASME JFE) · Sutherland's law · checked against an independent solution (714 checks at build) · Updated 23 Nov 2026
ρ = 1.1612 kg/m³ at the mean pressure, μ = 1.8459 × 10⁻⁵ Pa·s.
Report question: what velocity and mass flow should a 1 Pa drop across the channel give? Preset = the CONVERGE challenge.
Two-dimensional: front and back are not walls, so the flow is the same at every depth and ṁ scales with whatever depth you multiply by.
Report question: what does the fully developed parabola give, and how different is a real 10 × 10 mm duct from 2D plates?
Rectangular duct with walls on all four sides
Report question: total cell count for each base grid (2e-4, 1.5e-4, 1e-4 m), and what the mesh looks like near the wall.
Uses h, L and depth from tab 1 and its solved velocity: y+ from the fully developed wall shear 6μU/h at that U, the Courant number from the exit centreline limit √(2Δp/ρ). For more on each, see the y+ calculator and the Courant number calculator.
| dx (m) | along L | across h | deep | total (exact) | r | y+ (1st cell) | CFL |
|---|
Report question: "compare the three grids". Turn them into an apparent order, an extrapolated value and an error band.
Celik et al. (2008) Table 1, first column: dimensionless reattachment length behind a backward-facing step on 18,000, 8,000 and 4,500 cells (2D).
Type what your report states. Uses h, L, Δp, depth, dz and the inlet type from tab 1 and the fluid above.
- Type at least one number, or fill the typical report numbers.
What velocity does a 1 Pa drop give in a 10 mm channel?
About 0.94 m/s mean and up to 1.31 m/s on the centreline at the exit, for air at 300 K. That is the developing-flow answer for the first challenge of Skill-Lync's CONVERGE CFD course: a 0.1 m long, 0.01 m gap, 2D channel of air at 300 K, with 100,001 Pa at the inlet and 100,000 Pa at the outlet, laminar, run to a steady state on three base grids. The fluid properties are those of an ideal gas with Sutherland's viscosity:
The textbook answer for flow between parallel plates is plane Poiseuille flow. It assumes the velocity profile has stopped changing along the channel (fully developed):
That number is wrong for this channel, for two reasons the formula cannot see. A Reynolds number of 5,680 on Dh = 2h is above the range where turbulence can be sustained in a channel (see below), and at that Reynolds number the flow would need about 1.25 m to develop, twelve times the channel length. So the flow is never fully developed here, and the pressure drop is spent differently.
Why is the CFD velocity lower than the Poiseuille formula?
Because most of the 1 Pa goes into getting the air moving and into the high wall shear of the developing boundary layers near the inlet, not into fully developed friction. Shah and London (1978) fitted the apparent friction factor for laminar developing flow between parallel plates with a uniform inlet velocity; it includes the extra wall shear and the momentum change as the profile develops. The constants for parallel plates (K∞ = 0.674, C = 0.000029) are as reproduced in a University of Maryland thesis (Ali 2010, eq 3.2) and in MIT 2.006 notes:
The air starts at rest in the domain at the inlet pressure, so we treat the inlet pressure as a plenum (total) pressure: the first ½ρU² of the drop accelerates it into the channel. Then Δp(U) rises with U, and the tool solves Δp(U) = 1 Pa by bisection. The result: U = 0.9356 m/s, Re = 1,177 on Dh, x+ = 0.0042. The 1 Pa splits into 0.508 Pa of inlet dynamic head, 0.207 Pa of fully developed friction and 0.285 Pa of developing-flow excess.
A bound you can check by hand: if all of Δp went into dynamic head,
No mean velocity can exceed it, and since air in the inviscid core of a developing channel gets exactly that velocity from Bernoulli, the exit centreline sits just below it. A fully developed parabola for U = 0.936 m/s would peak at 1.5U = 1.403 m/s, above the 1.312 m/s limit, which shows again that the exit profile is still flatter than a parabola. Reports put the peak where this predicts: of 10 reports that give a per-grid peak, 6 give 1.2 to 1.32 m/s.
We cannot confirm from a public CONVERGE document whether its pressure inflow boundary fixes total or static pressure. If it were static (the air already at U at the inlet, no ½ρU² spent), the same correlation gives U = 1.520 m/s, a mean already above √(2Δp/ρ), which no report shows. The reports' velocities and mass flows match the plenum reading, so that is the default; tab 1 lets you switch. Shah's correlation is a curve fit and the sources we read do not state its accuracy for plates, so tab 5 gives percentage differences, not pass or fail.
Why does my report say the mass flow is 0.01 kg/s?
Because, as far as the numbers show, that value is per metre of depth. Per metre, ṁ = ρUh = 0.0109 kg/s. For the 0.01 m deep box it would be 1.086 × 10⁻⁴ kg/s, and for one cell deep at dz = 2 × 10−4 m, 2.173 × 10⁻⁶ kg/s. As of 23 Nov 2026, 13 of 182 public reports state a mass flow number, and 10 of them give about 0.01 kg/s. Where a report gives both a velocity and a mass flow on one grid, ṁ/(ρUh) comes out at 0.86 to 1.09 m, so the numbers behave like flow through a slice about 1 m deep.
We could not find a CONVERGE document that says how its 2D mass flow output is normalised, so treat the "per metre" reading as an inference from the reports, not as the solver's documented convention. One report computed 5.63 × 10−4 kg/s by hand with the fully developed formula for a 0.01 m deep duct; that is the Poiseuille velocity of 4.5 m/s again, not what the CFD does. Tab 5 tells you which depth your number implies.
Hydraulic diameter, Reynolds number and the laminar limit
For plates much wider than the gap, Dh = 4A/P = 2h, 20 mm here. The two Reynolds numbers in reports differ by a factor of two for that reason alone (the 2 reports that compute one use 0.01 m). Manneville's review of transition in wall-bounded flows gives the plane Poiseuille limits on R = Ucl(h/2)/ν: linear instability at R = 5,772 (Orszag 1971), turbulent spots growing for R ≥ 1,000 (Carlson et al.), turbulent bands maintained down to R ≈ 800. With Ucl = 1.5U that is ReDh = (8/3)R: about 2,133, 2,667 and 15,392. The developing answer, ReDh = 1,177, is below all three, so a laminar run is consistent. The Poiseuille answer, 5,680, is not.
The entrance length, by Chen's correlation (as given by Shah, quoted by Ray and Das 2023) and by Durst et al.'s 2005 fit rewritten on Dh (Ray, Durst and Ray):
At Re = 1,177 these give 0.259 m and 0.261 m. Both are longer than the 0.1 m channel, so the velocity profile is still developing at the outlet. 29 reports use the words "fully developed"; 7 of them say the flow becomes fully developed near the outlet of this channel, which these numbers do not support.
How different is a real 10 × 10 mm duct from 2D plates?
Quite different. With walls on all four sides the extra walls add friction. For fully developed laminar flow in a rectangle the flow rate has an exact series (Bruus, Theoretical microfluidics, eq 2.48d), which gives f·Re on Dh:
A square duct gives f·Re = 56.91 (Darcy) against 96 for plates; MIT 2.006 notes print 56.91. A square duct also has Dh = 10 mm, half the plates' value, so for the same 1 Pa over 0.1 m the fully developed mean velocity drops from 4.51 to 1.90 m/s. Tab 2 draws f·Re against the aspect ratio. The CONVERGE challenge is 2D (its front and back boundaries are set as 2D), so plates are the right model for it.
Why 25,000, about 45,000 and 100,000 cells?
A 2D grid one cell deep has (L/Δx)(h/Δy) cells:
With Δx = 1 × 10−4 m it is 1,000 × 100 = 100,000. With 1.5 × 10−4 m the quotients are 666.67 and 66.67, not whole numbers, and the exact product is 44,444. The solver has to round or trim cells at the boundaries; we could not find how CONVERGE does it in a public document, so read counts on that grid as approximate. 57 of 182 reports quote cell counts; the middle grid is written as 45,000 (21), 45,420 (8), 46,000 (4) and other values. The cells across the gap are 50, 66.7 and 100.
For a laminar run the first-cell y+ is small (about 0.59 on the coarsest grid with the fully developed wall shear at the solved velocity) and the Courant number at the 1.31 m/s limit with Δt = 10−5 s on the coarsest grid is 0.066. Neither decides the answer here; resolution across the gap does, which is what tab 4 measures.
How do you do a grid independence study with three meshes?
Use the five steps of Celik et al. (2008), the ASME Journal of Fluids Engineering procedure: a representative grid size, three grids with refinement ratios r = hcoarse/hfine preferably above 1.3, the apparent order p by fixed-point iteration, Richardson extrapolation and the fine-grid convergence index:
With a constant ratio r, q(p) = 0 and p = ln(ε32/ε21)/ln r, the form on NASA's NPARC page. A negative ε32/ε21 means oscillatory convergence, and if either ε is close to zero the procedure does not work. Tab 4 handles both and also flags divergence. The tool reproduces Celik's Table 1: for the reattachment length on 18,000, 8,000 and 4,500 cells, p = 1.53, φext = 6.1685, ea = 1.5%, eext = 1.7% and GCI = 2.2%, as printed. In the second column the paper prints eext = 0.9%, where its own φext = 10.8801 gives 0.85%: a rounding in the paper. NPARC's example gives p = 1.786170, GCI12 = 0.1031% and an asymptotic-range ratio of 1.002024.
For the challenge, φ can be the mass flow or the exit centreline velocity on the three grids. The challenge's ratios are 1.33 (2e-4 to 1.5e-4) and 1.5 (1.5e-4 to 1e-4); the slow-PC option 1.2e-4 gives 1.25, under Celik's 1.3. The "CONVERGE-style" button in tab 4 uses made-up values, second order and 3% low on the coarsest grid, around tab 1's 0.0109 kg/s per metre: p = 2.00, GCI = 0.94%. It shows the method; it is not student data. Celik also asks for iterative convergence first: "at least three (preferably four) orders of magnitude decrease in the normalized residuals".
What 182 channel flow reports wrote
We read the 182 public reports of the CONVERGE channel flow challenge as of 23 Nov 2026, n = 182. 1 has almost no text of its own (pictures only). Counts are of what the text shows, after removing the pasted challenge statement; numbers inside images were not read. The links are examples of reports that say it.
- 13 / 182State a mass flow rate number. CFD values run from 0.005 to 0.043 kg/s (one more report gives a hand-calculated 5.6e-4 kg/s for a 0.01 m deep duct). Ten of the 13 give about 0.01 kg/s for at least one grid. Where a report also gives a velocity, mdot/(rho U h) comes out at 0.86-1.09 m: the numbers behave like flow through a slice about 1 m deep, not the 0.01 m box. report 1report 2
- 16 / 182State a velocity number (m/s). Peak (centreline) values cluster at 1.2-1.3 m/s near the exit, close to the Bernoulli bound sqrt(2 x 1 Pa / rho) = 1.31 m/s; a few quote 2-5 m/s (plot scale or start-up transients). report 1report 2
- 57 / 182Quote total cell counts. Most quote 25,000 / about 45,000 / 100,000 for 2e-4 / 1.5e-4 / 1e-4 m; the middle grid is written as 45,000, 45,420, 45,460 or 46,000. report 1report 2
- 14 / 182Mention the entrance (entry) length or entrance region. Mostly a textbook definition; 2 reports compute a number (0.133 m and 0.4 m, both longer than the 0.1 m channel). report 1report 2
- 29 / 182Use the words "fully developed". Includes 7 reports that say the flow in this 0.1 m channel is or becomes fully developed near the outlet. report 1report 2
- 10 / 182Give a reason why the flow is laminar. Reasons given: the 1 Pa / low pressure difference (6), a low Reynolds number with no number computed (2), a simple flow (1), the parabolic profile (1). report 1report 2
- 35 / 182Say a finer mesh is "more accurate" (no number). Stated without a number; 2 of 182 put a figure on the change between grids. report 1report 2
- 37 / 182Note that one boundary's mass flow or velocity is negative. Reports disagree on which boundary is negative: 10 say the inlet, 5 say the outlet, the rest do not say. report 1report 2
- 36 / 182Say mass flow in = mass flow out (mass conserved). Usually read off the inlet and outlet mass flow plots being mirror images. report 1report 2
What stands out: almost nobody checks a number against a hand calculation (fewer than 10 do: 3 compare with one, 2 compute a Reynolds number, 2 compute an entrance length). 35 say the finer mesh is more accurate, and only 2 put a figure on the change between grids. On signs, 37 note that one boundary's mass flow is negative, but 10 say it is the inlet and 5 the outlet: the sign depends on how the solver orients each boundary, so compare magnitudes. 36 say mass in equals mass out. These are first-party counts, a starting point rather than a measure of ability.
How we checked the calculator
An independent Python script, scripts/verify/channel.py, rebuilds the numbers with its own code, and this page refuses to build if the browser code differs from it in any of 714 numbers or verdicts (193 further assertions run inside the script, 128 cases). It integrates the Poiseuille profile numerically, solves the developing flow by Newton-bisection in the Reynolds number (the browser bisects in velocity) and checks the residual, computes rectangular-duct f·Re from a double Fourier sine series against the single series and against printed Shah and London, MIT and NPTEL values, and finds the GCI order by bracketing instead of fixed-point iteration. Hand cases: the challenge (the corpus analyst's own solve, 0.9356 m/s), Celik's Table 1 to the printed digits and NASA NPARC's example. Two deliberate bugs (12 → 8 in the Poiseuille formula, the GCI safety factor 1.25 → 3) each make the build fail.
What this calculator does not cover
- Developing velocity profiles. The sources we read give the pressure drop of developing flow, not the profile, so the chart shows the uniform inlet and the parabola for the same mean.
- Laminar only. Shah's correlation is for laminar flow; above about ReDh 2,667 the tool warns but does not model turbulence. For turbulent pipes see the pipe flow calculator.
- Incompressible. A 1 Pa drop changes air density by 0.001%; for drops of several percent of the pressure, compressibility matters.
- The solver's own conventions. How CONVERGE treats the inlet pressure, rounds cell counts and normalises 2D mass flow is not in any public document we found; the page says where it infers.
- GCI limits. Three grids, one quantity at a time. Celik suggests a least-squares GCI for noisy convergence; it is not here.
The channel flow case is the first challenge in Skill-Lync's CONVERGE CFD course. Other CONVERGE projects take the same workflow to throttle bodies, shock tubes and airfoils.
Frequently asked questions
What is channel flow?
Channel flow is flow through the gap between two walls, usually two flat parallel plates far wider than the gap. Driven by a pressure difference, it is the two-dimensional cousin of pipe flow. Fully developed and laminar, it has a parabolic velocity profile, plane Poiseuille flow, with the peak at the centre.
What is the formula for plane Poiseuille flow?
For laminar, fully developed flow between plates a gap h apart, the mean velocity is U = h²Δp/(12μL), the peak is 1.5U at mid-gap and the wall shear stress is 6μU/h. It holds only once the flow is fully developed, far downstream of the inlet, and only while the flow stays laminar.
What is the hydraulic diameter of two parallel plates?
Dh = 4A/P. For plates a gap h apart and a depth W much larger than h, A = hW and the wetted perimeter is about 2W, so Dh = 2h. A 10 mm channel has Dh = 20 mm. A square 10 × 10 mm duct has Dh = 10 mm, so say which one your Reynolds number uses.
What is the entrance length for laminar flow between plates?
Chen's correlation, as given by Shah, is Lh/Dh = 0.315/(0.0175 Re + 1) + 0.011 Re with Re on Dh = 2h. Durst's 2005 fit gives nearly the same. At the challenge's Re of about 1,180 it is about 0.26 m, longer than the 0.1 m channel, so the flow never fully develops.
Why is my CFD velocity lower than the Poiseuille formula?
The Poiseuille formula assumes fully developed flow. In a short channel most of the pressure drop goes into accelerating the air from rest and into the extra wall shear near the inlet. For the 1 Pa challenge the formula says 4.5 m/s; a developing-flow correlation gives a mean of 0.94 m/s.
What is a grid independence study?
A grid independence study runs the same case on three or more systematically refined meshes and checks how much a key result changes. If the change shrinks at the rate the scheme's order predicts, you can estimate the discretisation error and the grid-free value instead of just saying the finest mesh is more accurate.
What is the grid convergence index (GCI)?
The GCI is Roache's error band on a grid solution. In Celik's 2008 procedure, from three grids you find the apparent order p, extrapolate to zero grid size, then GCI = 1.25 × relative change / (r^p − 1). Celik's backward-step example reports a fine-grid uncertainty of 2.2% for the reattachment length.
How many cells should go across a channel?
No fixed number: the cells across the gap must resolve the velocity profile well enough that the result stops changing. The challenge's grids put 50, about 67 and 100 cells across 10 mm. Tab 4 tells you whether those three grids are converging and what error band they give.
What base grid sizes does the CONVERGE channel flow challenge use?
The challenge runs dx = dy = dz = 2e-4, 1.5e-4 and 1e-4 m, or 1.2e-4 m for the finest on a slow PC. Celik's procedure wants grid ratios above 1.3: 2e-4 to 1.5e-4 is 1.33 and 1.5e-4 to 1e-4 is 1.5, but 1.5e-4 to 1.2e-4 is only 1.25.
Related on Skill-Lync
- Pipe flow calculator (the circular-pipe version: Hagen-Poiseuille, Shah's entrance correlation for tubes, Colebrook)
- y+ calculator (first cell height for a target y+)
- Courant number calculator (time step and CFL)
- Mesh quality calculator (aspect ratio, skewness and growth)
- Backward-facing step calculator (the flow behind Celik's GCI example)
- Throttle body calculator (the CONVERGE throttle case)
- CFD courses compared
- All free engineering tools
Sources
- R. K. Shah and A. L. London, Laminar Flow Forced Convection in Ducts, Academic Press (1978): parallel-plate apparent friction factor as reproduced in I. A. Ali, PhD thesis, University of Maryland (2010), eq 3.2-3.3, and MIT 2.006 course notes (2009), eq 9.115.
- D. R. Ray and D. K. Das, Simulations of Flows via CFD in Microchannels, Micromachines 14, 1418 (2023): Chen's entrance length coefficients, eq 24; Shah and London rectangular-duct f·Re, eq 17 and Table 11.
- D. Ray, F. Durst and S. Ray, arXiv 1707.04947: Durst et al. (2005) channel development length on Dh, eq 2b.
- P. Manneville, Transition to turbulence in wall-bounded flows: Where do we stand?, arXiv 1604.00840: Rc = 5,772, R ≥ 1,000, R ≈ 800.
- H. Bruus, Theoretical microfluidics, lecture notes (2006), eq 2.48d; A. W. Date, NPTEL ME-662 lectures 14-15 (IIT Bombay); MIT 2.006 notes Table 9.3.
- I. B. Celik, U. Ghia, P. J. Roache and C. J. Freitas, Procedure for Estimation and Reporting of Uncertainty Due to Discretization in CFD Applications, ASME J. Fluids Eng. editorial policy (published as JFE 130(7) 078001, 2008): eq 1-7, Table 1.
- NASA Glenn NPARC Alliance, Examining Spatial (Grid) Convergence: constant-r order, Richardson extrapolation, GCI and worked example.
- CFD-Wiki, Sutherland's law (air: 1.716 × 10−5 Pa·s, 273.15 K, 110.4 K); NMSU PDS Atmospheres node, gas constant of air 287.05 J/(kg·K); water: NIST WebBook values as in the pipe flow calculator.
- Skill-Lync, the 182 public reports of "Week 1: Channel flow simulation using CONVERGE CFD", read 23 Nov 2026.