GATE Electrical: Power Electronics (commutation, choppers, DC-DC converters, inverters), previous-year questions solved

Part 2 of the GATE EE Power Electronics questions from the official 2022-2026 papers: resonant and forced commutation of thyristors, MOSFET turn-off overshoot, two-quadrant choppers, buck, boost and buck-boost converters read from their current waveforms, square-wave and sinusoidal-PWM inverters. Every solution matches the official answer key and notes the common traps. Devices, rectifiers and power factor are on part 1.

Questions from official GATE EE papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 16 Nov 2026 · 15 questions

GATE 2023 · EE · Q.55NAT · 2 marksCommutation and switching transients

Thyristor with a 1 µF, 4 µH ring across it: for how long does it conduct before turning off?

The circuit shown in the figure has reached steady state with thyristor ‘T’ in OFF condition. Assume that the latching and holding currents of the thyristor are zero. The thyristor is turned ON at sec. The duration in microseconds for which the thyristor would conduct, before it turns off, is _____ (Round off to 2 decimal places).
100 V battery; from its positive terminal, thyristor T points down to a middle node; a 1 microfarad capacitor and a 4 microhenry inductor in series also connect the top node to the middle node; the middle node returns to the battery negative through 4 ohm+100 VTC = 1 µFL = 4 µH4 Ω

Answer: 7.33 µs Official key: 7.1 to 7.5

  1. Before : no DC current flows through C, so the capacitor holds the full 100 V (positive at the top node) and the resistor carries nothing.
  2. With T on, the top and middle nodes are joined. Two independent loops: the battery drives through T and the 4 Ω resistor; and C discharges through T and L as an LC ring.
  3. Ring: , , peak , flowing forward through T first.
  4. . It reaches zero when , the first time at .
  5. .

Trap: stopping at the half cycle (), forgetting that the 25 A load current must be cancelled before T turns off. Stepping the LC loop numerically gives 7.330 µs.

Where this shows up in industry

This is resonant (class C) commutation, the classic way thyristor choppers and inverters were turned off before gate-turn-off devices existed; the same LC ring is used today in resonant converters to switch at zero current.

GATE 2024 · EE · Q.35NAT · 1 markCommutation and switching transients

Forced-commutated chopper with a 10 µF capacitor at 50 V and 10 A load: what turn-off time does ThM get?

A forced commutated thyristorized step-down chopper is shown in the figure. Neglect the ON-state drop across the power devices. Assume that the capacitor is initially charged to 50 V with the polarity shown in the figure. The load current () can be assumed to be constant at 10 A. Initially, is ON and is OFF. The turn-off time available to in microseconds, when is triggered, is_________ (rounded off to the nearest integer).
50 V source; main thyristor ThM from the positive rail to the load; a 10 microfarad capacitor from the load side of ThM down to a node N, positive plate at the top; from the positive rail, an inductor L in series with a diode pointing from N towards L, and the auxiliary thyristor ThA from the positive rail to N; a freewheeling diode across the constant-current 10 A load+50 VThM+−10 µFLThAConstantcurrentloadIL = 10 A

Answer: 50 µs Official key: 50 to 50

  1. Firing connects the capacitor's negative plate to the positive rail, so the cathode of jumps to 50 V above its anode: is reverse biased and turns off at once.
  2. The 10 A load current now flows through and the capacitor. A constant current discharges it linearly: .
  3. stays reverse biased until reaches zero: .

The inductor branch is for resetting the capacitor polarity later; it plays no part in this interval. The thyristor's datasheet turn-off time must be shorter than this 50 µs.

Where this shows up in industry

Voltage (class D) commutation like this was the workhorse of thyristor DC choppers in battery vehicles and early metro trains; sizing C so that circuit turn-off time exceeds tq at maximum load current was the core design calculation.

GATE 2026 · EE · Q.28MCQ · 1 markCommutation and switching transients

MOSFET turn-off overshoot with a resistor in the freewheeling path: how do R1, R2 and R3 compare?

Consider the circuit shown in Figure (a). A gate pulse is applied between time instants and . After , during the MOSFET turn OFF process, it experiences a voltage overshoot. Based on the waveforms shown in Figure (b), which one of the following options is correct?
(a) Inductive load L from VDC to the MOSFET drain, with a freewheeling branch of resistor Rf in series with diode D across L; gate driven through Rg. (b) vds: equal to VDC before t0, zero while the gate pulse is on, then after t1 an overshoot that decays back to VDC; the overshoot is highest with Rf = R1, lower with Rf = R3 and lowest with Rf = R2VDCLRfDRg+−vds(a)tvdswith Rf = R₁with Rf = R₃with Rf = R₂VDCt₀t₁(b)
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (B) Official key: B

  1. While the MOSFET is on, the inductor current builds up to some .
  2. At turn-off the inductor keeps flowing, now through and D. The drain then sits at : the overshoot is proportional to .
  3. The overshoot then decays with time constant , faster for larger , which matches the tallest curve also settling fastest.
  4. Tallest to lowest overshoot: , , . So : option (B).

Trap: reading the legend order (, , top to bottom) as .

Where this shows up in industry

This is the trade-off in every relay, solenoid and injector driver: a plain freewheeling diode keeps the switch voltage low but lets the current decay slowly; adding resistance (or a Zener) speeds up the release at the cost of a higher voltage the MOSFET must be rated for.

GATE 2023 · EE · Q.23MCQ · 1 markChoppers and DC-DC converters

Two-switch chopper feeding a 5 A sink with S1 on for 3 µs of 10 µs: what is the average output voltage?

The chopper circuit shown in figure (i) feeds power to a 5 A DC constant current source. The switching frequency of the chopper is 100 kHz. All the components can be assumed to be ideal. The gate signals of switches and are shown in figure (ii). Average voltage across the 5 A current source is
(i) 20 V source across two switches S1 (top) and S2 (bottom), each with an antiparallel diode D1, D2; a 5 A current source draws current from the midpoint to the negative rail across S2. (ii) S1 gate is high from 0 to 3 microseconds and again from 10 to 13; S2 gate is high from 5 to 8 and 15 to 18+20 VS₁D₁S₂D₂5 Afigure (i)S₁ gateS₂ gate035810t (µs)figure (ii)
  1. (A)10 V
  2. (B)6 V
  3. (C)12 V
  4. (D)20 V

Answer: (B) Official key: B

  1. The 5 A source pulls current out of the midpoint towards the negative rail, so the midpoint must be supplied: either through from +20 V or through from 0 V.
  2. on (0 to 3 µs of each 10 µs): midpoint at 20 V.
  3. off: the current freewheels up through , midpoint at 0 V. Turning on changes nothing, because can only carry current downward and the current is flowing upward through .
  4. : option (B).

Trap: thinking 's pulse from 5 to 8 µs matters. It is a decoy: in this direction of current only and do any work.

Where this shows up in industry

This half bridge is one leg of every two-quadrant DC motor drive and every inverter; whether the switch or the opposite diode conducts depends on the direction of the load current, which is why gate signals alone never tell you the output voltage.

GATE 2023 · EE · Q.44MSQ · 2 marksChoppers and DC-DC converters

Current sources, batteries and three diodes: which diodes conduct with switch S on and off?

All the elements in the circuit shown in the following figure are ideal. Which of the following statements is/are true?
10 V battery, then a 4 A DC source into node X; diode D2 from X to the positive of a 20 V battery; a 2 A DC source from there into node Z; switch S from Z to the common negative; diode D3 from Z to the positive of a 40 V battery; diode D1 from X directly to Z. All battery negatives are common+10 V4 A, DCD₂+20 V2 A, DCSD₃+40 VD₁
  1. (A)When switch S is ON, both and conducts and is reverse biased
  2. (B)When switch S is ON, conducts and both and are reverse biased
  3. (C)When switch S is OFF, is reverse biased and both and conduct
  4. (D)When switch S is OFF, conducts, is reverse biased and conducts

Answer: (B) and (C) Official key: B, C

  1. Call X the node after the 4 A source and Z the node after the 2 A source. Current sources force their current, so each must find a path.
  2. S ON: Z is shorted to 0 V. has 0 V on its anode and 40 V on its cathode: reverse biased. The 4 A at X can reach 0 V through (which clamps X at ) or the 20 V battery through (which would need X at ). The lowest path wins: conducts, , and sees 0 V against 20 V: reverse biased. (B) true, (A) false.
  3. S OFF: the 2 A into Z can only leave through , so conducts and . The 4 A at X now takes into the 20 V battery (); has 20 V on its anode and 40 V on its cathode: reverse biased. (C) true, (D) false.

We checked all eight on/off combinations of the three diodes for each switch position: exactly one is consistent (every conducting diode carries forward current, every blocking diode is reverse biased) in each case.

Where this shows up in industry

Reasoning 'which diode conducts' from forced currents is exactly how commutation intervals in converters with inductive (current-source-like) loads are worked out, for example the freewheeling diode taking over in a buck converter when the switch opens.

GATE 2025 · EE · Q.34NAT · 1 markChoppers and DC-DC converters

10 A current source switched into a 15 V battery at duty 0.4: how much power does the source deliver?

In the circuit with ideal devices, the power MOSFET is operated with a duty cycle of 0.4 in a switching cycle with A and V. The power delivered by the current source, in W, is ____________ (round off to the nearest integer).
Current source I in parallel with a power MOSFET (with antiparallel diode); from the top node a diode feeds a battery V, positive terminal on topI+V

Answer: 90 W Official key: 90 to 90

  1. MOSFET on (40% of the cycle): it shorts the current source, which then sees 0 V and delivers no power.
  2. MOSFET off (60%): the 10 A has to go through the diode into the battery, so the source sees 15 V.
  3. Average voltage across the source .
  4. (all of it into the battery).

Trap: using instead of gives 60 W. This is a boost stage: a current-fed input (like an inductor with a large current) delivering into a voltage sink.

Where this shows up in industry

Replace the current source by a large inductor and this is the boost converter used in solar MPPT stages and PFC front ends; the duty cycle controls how much of the input current is diverted into the output, which is how the power is controlled.

GATE 2022 · EE · Q.61NAT · 2 marksChoppers and DC-DC converters

Buck-boost inductor current 12 to 16 A over 20 and 30 µs: what output capacitor gives 1 V ripple?

The steady state current flowing through the inductor of a DC-DC buck boost converter is given in the figure below. If the peak-to-peak ripple in the output voltage of the converter is 1 V, then the value of the output capacitor, in µF, is _______________. (round off to nearest integer)
Buck-boost inductor current: rises linearly from 12 A to 16 A in 20 microseconds, then falls linearly back to 12 A in 30 microsecondstime (µs)inductor current (A)12162030

Answer: 168 µF Official key: 165 to 171

  1. Rising current means the switch is on: , , .
  2. In a buck-boost the output only receives inductor current during the off time, so .
  3. During the on time the capacitor alone feeds the load: it loses .
  4. .

Trap: using the average inductor current (14 A) as the load current gives 280 µF. A charge integral of (diode current minus load current) over a cycle gives 168.0 µF.

Where this shows up in industry

Buck-boost (and its isolated cousin, the flyback) has a pulsating output current, so the output capacitor sees large ripple current; sizing it, and checking its RMS current rating, is a routine step in designing LED drivers and chargers.

GATE 2024 · EE · Q.64NAT · 2 marksChoppers and DC-DC converters

Boost converter 20 V to 40 V into 10 Ω, 2 mH at 500 Hz: what is the peak inductor current?

In the DC-DC converter shown in the figure, the current through the inductor is continuous. The switching frequency is 500 Hz. The voltage () across the load is assumed to be constant and ripple free. The peak inductor current in amperes is _________ (rounded off to the nearest integer).
Boost converter: 20 V input, 2 mH inductor, switch S to ground, diode to the output capacitor and 10 ohm load; output voltage 40 V+Vᵢ = 20 VL = 2 mHIᵢS+Vₒ = 40 V10 ΩIₒ

Answer: 13 A Official key: 13 to 13

  1. Boost in continuous conduction: , so .
  2. Load current ; the average inductor (input) current is (power balance: ).
  3. Ripple: .
  4. Peak .

Trap: the low 500 Hz makes the ripple huge (10 A on an 8 A average), so leaving out the ripple term gives 8 A. The current still stays continuous (minimum 3 A).

Where this shows up in industry

Peak inductor current is what sets the inductor's saturation rating and the switch's current rating; designers pick the switching frequency to keep this ripple to 20 to 40% of the average, which is why real boost converters run at 50 kHz and up, not 500 Hz.

GATE 2025 · EE · Q.60NAT · 2 marksChoppers and DC-DC converters

Buck converter capacitor current ±0.1 A over a 50 µs cycle from 30 V: what is the inductance?

The steady state capacitor current of a conventional DC-DC buck converter, working in CCM, is shown in one switching cycle. If the input voltage is 30 V, the value of the inductor used, in mH, is ____________ (round off to one decimal place).
Buck converter capacitor current over one switching cycle: rises linearly from minus 0.1 A at t = 0 through zero at 15 microseconds to plus 0.1 A, then falls through zero at 40 microseconds to minus 0.1 A at 50 microsecondstime (µs)capacitor current (A)1540500.1−0.1

Answer: 1.8 mH Official key: 1.7 to 1.9

  1. The capacitor current is the inductor ripple: . So the inductor current rises while rises and peak to peak.
  2. Rise: from at 0 through zero at 15 µs, so it reaches at 30 µs. of : .
  3. Buck: .
  4. On-time slope: .

Check with the off time: , consistent with the fall through zero at 40 µs. Trap: reading the zero crossing at 15 µs as the end of the on time.

Where this shows up in industry

Engineers do this in reverse on the bench: measure the capacitor or inductor ripple with a current probe and back out the duty cycle and inductance, a quick check that a buck converter's inductor has not partly saturated.

GATE 2026 · EE · Q.48MCQ · 2 marksChoppers and DC-DC converters

Boost converter with inductor current 0 to 6 A to 0 in 10 µs steps into 10 Ω: what is the input voltage?

Consider the boost converter circuit shown. Assume that the semiconductor devices are ideal. In steady state, the inductor current rises linearly from 0 A to 6 A in the first 10 s and then falls linearly from 6 A to 0 A in the next 10 s of every switching cycle as shown. The load resistance R is 10 Ω and the capacitance C is 500 F. Neglect the ripple in the output voltage. What is the input voltage ?
Boost inductor current: rises linearly from 0 to 6 A in the first 10 microseconds and falls back to 0 in the next 10 microseconds, repeating every 20 microsecondst (µs)iL (A)102030406
  1. (A)10.0 V
  2. (B)15.0 V
  3. (C)7.5 V
  4. (D)12.5 V

Answer: (C) Official key: C

  1. The diode carries the inductor current only while it falls (10 µs of every 20 µs): average diode current , and that is the load current.
  2. .
  3. Equal rise and fall times mean equal slopes: , so : option (C).

Power check: input (average inductor current 3 A) equals output . Trap: option (B) is . The 500 µF only tells you the output ripple is negligible.

Where this shows up in industry

Running exactly at the boundary between continuous and discontinuous conduction (critical-conduction mode) is how many PFC controllers and LED drivers operate, because the switch turns on at zero current and switching loss drops.

GATE 2022 · EE · Q.58NAT · 2 marksInverters and PWM

Square-wave full-bridge inverter at 1000 V with a 10 A sinusoidal current lagging 60°: what active power?

Consider an ideal full-bridge single-phase DC-AC inverter with a DC bus voltage magnitude of 1000 V. The inverter output voltage shown below, is obtained when diagonal switches of the inverter are switched with 50 % duty cycle. The inverter feeds a load with a sinusoidal current given by, A, where . The active power, in watts, delivered to the load is _________. (round off to nearest integer)
Inverter output voltage v(t): positive from 0 to 0.5T, negative from 0.5T to T, then positive againt (sec)v(t)00.5TT

Answer: 3183 W Official key: 3170 to 3190

  1. The current is a pure sinusoid at the fundamental, so only the fundamental of the square wave delivers power.
  2. A square wave has fundamental amplitude , in phase with .
  3. .

Trap: using the square wave's RMS (1000 V) with the current RMS gives . Integrating numerically over a period gives 3183.1 W.

Where this shows up in industry

Square-wave (six-step) operation gives the highest fundamental voltage an inverter can produce, 27% more than sinusoidal PWM at full modulation, which is why EV traction inverters switch to it at top speed to get more torque from the same battery.

GATE 2022 · EE · Q.60NAT · 2 marksInverters and PWM

Grid-connected VSC on a 1000 V link, 10 A, S = −4000 − j3000 VA: what is the SPWM modulation index?

A 3-phase grid-connected voltage source converter with DC link voltage of 1000 V is switched using sinusoidal Pulse Width Modulation (PWM) technique. If the grid phase current is 10 A and the 3-phase complex power supplied by the converter is given by VA, then the modulation index used in sinusoidal PWM is ___________. (round off to two decimal places)

Answer: 0.47 Official key: 0.46 to 0.48

  1. Apparent power , so RMS.
  2. Sinusoidal PWM (linear range): fundamental phase voltage peak .
  3. .

The minus signs (the converter absorbing real power and supplying reactive power in the other sense) do not change . Trap: using the line voltage, or instead of , gives 0.82 or 0.24.

Where this shows up in industry

Grid-tied inverters for solar, batteries and STATCOMs run in exactly this range; the modulation index tells you how much headroom the controller has before over-modulation, which is why DC-link voltage is chosen with grid-voltage swings in mind.

GATE 2025 · EE · Q.46MCQ · 2 marksInverters and PWM

Three-phase SPWM with 0.8 modulation on a 600 V link: what is the per-phase fundamental RMS voltage?

The 3-phase modulating waveforms (, and ), used in sinusoidal PWM in a Voltage Source Inverter (VSI) are V, V, V, where rad/s is the fundamental frequency. The modulating waveforms are compared with a 10 kHz triangular carrier whose magnitude varies between and . The VSI has a DC link voltage of 600 V and feeds a star connected motor. The per phase fundamental RMS motor voltage, in volts, is closest to
  1. (A)169.71
  2. (B)300.00
  3. (C)424.26
  4. (D)212.13

Answer: (A) Official key: A

  1. Modulation index (linear range).
  2. Each leg's fundamental (pole to DC midpoint) has peak . In a balanced star load, the phase voltage has the same fundamental.
  3. RMS : option (A).

Trap: (C) 424.26 is -type confusion with the line value; (D) 212.13 uses without . We simulated the inverter (10 kHz carrier compared with all three references, star-point voltage removed) and took the 40 Hz Fourier component of the motor phase voltage: 169.7 V RMS.

Where this shows up in industry

This is the V/f drive inside every industrial VFD: at 40 Hz the drive lowers the modulation index (here 0.8) so the motor's voltage drops in proportion to frequency and the flux stays constant.

GATE 2024 · EE · Q.63NAT · 2 marksInverters and PWM

Square-wave VSI at 100 V and 50 Hz on a 20 mH inductor: what is the peak-to-peak current?

A single-phase full bridge voltage source inverter (VSI) feeds a purely inductive load. The inverter output voltage is a square wave in 180° conduction mode. The fundamental frequency of the output voltage is 50 Hz. If the DC input voltage of the inverter is 100 V and the value of the load inductance is 20 mH, the peak-to-peak load current in amperes is _________ (rounded off to the nearest integer).

Answer: 50 A Official key: 50 to 50

  1. The inductor sees for half a period and for the other half: the current is a triangle.
  2. In one half period () the current changes by .
  3. That change is the peak-to-peak value: 50 A (from to A in steady state).

Trap: using only the fundamental ( over ) gives ; the harmonics of a square wave are not negligible here.

Where this shows up in industry

The triangular current in an inductive load is the basis of inverter current-ripple calculations and of dead-time and switch-rating design; it is the same mechanism that sets ripple in a motor's phase current.

GATE 2026 · EE · Q.47MCQ · 2 marksInverters and PWM

Single-phase VSI with a ±5 A triangular inductor current: what is the RMS current in switch S1?

Consider the single-phase voltage source inverter circuit feeding an inductive load (). Assume that the power MOSFET switches are ideal. and are switched on during the first 10 s, and and are switched on during the next 10 s in a switching cycle. The switches in the same leg are thus switched in a complementary fashion. Neglect the dead time. The waveform of the inductor current () in the steady state is triangular with a peak value of 5 A as shown. The rms value of the current through the switch is:
Inverter inductor current: triangular between minus 5 A and plus 5 A, rising from 0 to 10 microseconds, falling from 10 to 20 microseconds, period 20 microsecondst (µs)iL (A)102030405−5
  1. (A)2.88 A
  2. (B)2.04 A
  3. (C)3.54 A
  4. (D)2.50 A

Answer: (B) Official key: B

  1. (MOSFET with its diode) carries the load current for the first 10 µs of each 20 µs: a ramp from to (negative part through the diode or reverse channel, positive part through the channel).
  2. The RMS of a symmetric ramp over its own interval is .
  3. It conducts half the time: : option (B).

Trap: (A) 2.88 A is the load current RMS () forgetting the half duty. Counting only the positive (channel) part would give 1.44 A, not an option, which confirms the question means the whole switch. Numerical RMS integration gives 2.041 A.

Where this shows up in industry

Switch RMS current sets conduction loss (), the first number in a MOSFET or IGBT thermal design; splitting it between channel and diode matters when choosing devices with synchronous rectification.

From GATE prep to a power electronics career

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.