GATE Electrical: Control Systems (Bode, Nyquist, compensators, state space), previous-year questions solved

Part 2 of the GATE EE Control Systems questions from the official 2022-2026 papers: transfer functions read off Bode plots, ramp error from the Bode slope, Nyquist encirclements, lead, PI and PD design for a target phase margin, and state-space poles, zeros and similarity transforms. Every solution matches the official answer key and notes the common traps. Block diagrams, time response and stability are on part 1.

Questions from official GATE EE papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 16 Nov 2026 · 13 questions

GATE 2022 · EE · Q.17MCQ · 1 markBode plots

First-order stable system with flat Bode magnitude and phase going to −180°: what are its poles and zeros?

The Bode magnitude plot of a first order stable system is constant with frequency. The asymptotic value of the high frequency phase, for the system, is . This system has
Bode plot sketch: magnitude constant at all frequencies; phase starts at 0 degrees and falls to minus 180 degrees at high frequencylog(f)magnitudephase0°−180°
  1. (A)one LHP pole and one RHP zero at the same frequency.
  2. (B)one LHP pole and one LHP zero at the same frequency.
  3. (C)two LHP poles and one RHP zero.
  4. (D)two RHP poles and one LHP zero.

Answer: (A) Official key: A

  1. First order and stable: exactly one pole, in the left half plane. That rules out (C) and (D).
  2. Constant magnitude: the zero must sit at the same frequency as the pole, so for every if the zero is at .
  3. Phase: the LHP pole contributes ; a RHP zero also contributes , so the total goes to . An LHP zero would contribute and cancel the pole completely (that is option (B), a constant).
  4. One LHP pole and one RHP zero at the same frequency: option (A), the all-pass filter .

We checked a representative of each option numerically from 0.001 to 1000 rad/s: only has a flat magnitude and phase from to .

Where this shows up in industry

All-pass behaviour is a non-minimum-phase effect: the system responds in the 'wrong' direction first. It shows up in boost converters, in steam drums (swell) and as a Padé approximation of a pure time delay in controller design, and it limits how fast any loop around it can be tuned.

GATE 2023 · EE · Q.36MCQ · 2 marksBode plots

Flat 8 dB magnitude and phase falling linearly to −60° at 1 rad/s: what is the transfer function?

The magnitude and phase plots of an LTI system are shown in the figure. The transfer function of the system is
Magnitude plot against log omega: flat at 8 dB. Phase plot against omega on a linear axis: a straight line from 0 degrees at omega = 0 through minus 60 degrees at omega = 1 rad/slog₁₀ω, rad/sMagnitude8 dB0 dBω (rad/s)0°1−60°Phase
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (D) Official key: D

  1. A flat magnitude with a phase that falls in proportion to (a straight line on a linear frequency axis) is a gain times a pure delay: , with and .
  2. Gain: dB, so .
  3. Delay: rad, so s.
  4. : option (D).

Distractors: (C) has the right delay in degrees ( is not ) but the wrong gain; (B) has a term, so its magnitude would roll off; (A) has a delay of 0.032 s, which gives only at 1 rad/s. Note the phase plot uses a linear axis while the magnitude uses .

Where this shows up in industry

Transport delays are everywhere in real plants: conveyor belts, long pipes in process plants, network latency in remote control, and the computation delay of a digital controller. Because a delay adds phase lag that grows with frequency, it sets a hard limit on loop bandwidth, which is why Smith predictors exist.

GATE 2026 · EE · Q.29MCQ · 1 markBode plots

Asymptotic magnitude falls at −20 dB/decade to 0 dB at ω0, then stays flat: which G(s)?

The asymptotic Bode magnitude plot of a system is shown. Which one of the following options best represents the transfer function of the system?
Asymptotic Bode magnitude: a straight line falling at minus 20 dB per decade that reaches 0 dB at omega 0, then flat at 0 dB above omega 0ω₀0 dB−20 dB/decadeω (log-scale)|G(jω)| (dB)
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (A) Official key: A

  1. A slope of dB/decade from the lowest frequencies means a pole at the origin (an integrator).
  2. The slope changes by dB/decade at to become flat, so there is a zero at .
  3. The line reaches 0 dB exactly at : the integrator is . So : option (A).

(B) is a high-pass filter (+20 dB/decade below ); (C) and (D) have a flat 0 dB magnitude at every frequency. Checked numerically: only (A) has slope dB/decade well below and 0 dB well above it. This is exactly a PI controller, with , .

Where this shows up in industry

This is the Bode shape of a PI controller: infinite gain at DC (no steady-state error) and plain proportional gain above the corner. Drive and converter engineers place the PI zero a few times below the crossover frequency so the integrator's phase lag does not eat into the phase margin.

GATE 2024 · EE · Q.58NAT · 2 marksBode plots

Bode slope −20 dB/decade with gain crossover at 10 rad/s: what is the steady-state error for a unit ramp?

Consider the stable closed-loop system shown in the figure. The asymptotic Bode magnitude plot of has a constant slope of dB/decade at least till 100 rad/sec with the gain crossover frequency being 10 rad/sec. The asymptotic Bode phase plot remains constant at at least till rad/sec. The steady-state error of the closed-loop system for a unit ramp input is ______________ (rounded off to 2 decimal places).
Unity negative feedback loop with forward block G(s)R(s)+−G(s)C(s)

Answer: 0.10 Official key: 0.09 to 0.11

  1. Constant dB/decade slope and constant phase at low frequency: there (a type-1 system).
  2. The asymptote crosses 0 dB at 10 rad/s: , so .
  3. Velocity error constant .
  4. Unit-ramp error .

For a type-1 system the low-frequency asymptote always crosses 0 dB at , so you can read straight off the plot. That trick is the whole question.

Where this shows up in industry

Ramp tracking error is what a radar antenna, a CNC axis following a contour or a solar tracker shows when following a steadily moving target. Designers read off the Bode plot to check that the following error stays within tolerance at the maximum feed rate.

GATE 2022 · EE · Q.38MCQ · 2 marksNyquist criterion

G(s) = 1/(s(s+1)) with the contour bulging left round the origin: how many times is −1 encircled?

The open loop transfer function of a unity gain negative feedback system is given as The Nyquist contour in the -plane encloses the entire right half plane and a small neighbourhood around the origin in the left half plane, as shown in the figure below. The number of encirclements of the point by the Nyquist plot of , corresponding to the Nyquist contour, is denoted as . Then equals to
Nyquist contour in the s-plane: up the imaginary axis, a large clockwise semicircle enclosing the right half plane, and a small semicircle around the origin bulging into the left half plane so that the pole at the origin lies inside the contour; the point minus 1 is marked on the real axisRe(s)Im(s)×−1×
  1. (A)0
  2. (B)1
  3. (C)2
  4. (D)3

Answer: (B) Official key: B

  1. Nyquist criterion: , where is the number of open-loop poles inside the contour, the number of closed-loop poles inside it and the number of clockwise encirclements of .
  2. The small detour goes into the left half plane, so the pole at is inside the contour: .
  3. Closed loop: , roots . Neither is inside (neither is in the right half plane or at the origin): .
  4. : one anticlockwise encirclement. , option (B).

We traced the drawn contour numerically and counted the winding of round the origin: turn (anticlockwise). With the usual detour into the right half plane instead, and : the closed loop is the same stable system either way. The choice of detour changes the count, not the conclusion.

Where this shows up in industry

The Nyquist plot is the tool of choice when the plant has delays, right-half-plane poles or measured (not modelled) frequency response: frequency-response analysers inject a sweep into a running power supply or drive and the stability margins are read off the measured curve.

GATE 2023 · EE · Q.13MCQ · 1 markNyquist criterion

G(s)H(s) = (3s+5)/(s−1): where does the infinite semicircle of the Nyquist contour map?

In the Nyquist plot of the open-loop transfer function corresponding to the feedback loop shown in the figure, the infinite semi-circular arc of the Nyquist contour in s-plane is mapped into a point at
Negative feedback loop with forward block G(s) and feedback block H(s)R(s)+−G(s)C(s)H(s)
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (C) Official key: C

  1. On the infinite arc, with .
  2. for every .
  3. The whole arc collapses to the single point : option (C).

General rule: the infinite arc maps to . That is 0 for strictly proper functions (more poles than zeros) and the ratio of leading coefficients for biproper ones like this. is the value at , a different point of the plot.

Where this shows up in industry

Biproper loop transfer functions (as many zeros as poles) come from lead compensators and PD action, which keep gain at high frequency. That is why practical PD controllers always add a roll-off filter: unlimited high-frequency gain amplifies sensor noise.

GATE 2023 · EE · Q.38MCQ · 2 marksCompensators and controller design

Lead compensator with maximum phase lead at 4 rad/s and 6 dB asymptotic gain there: what are a and β?

Consider a lead compensator of the form The frequency at which this compensator produces maximum phase lead is 4 rad/s. At this frequency, the gain amplification provided by the controller, assuming asymptotic Bode-magnitude plot of , is 6 dB. The values of , respectively, are
  1. (A)1, 16
  2. (B)2, 4
  3. (C)3, 5
  4. (D)2.66, 2.25

Answer: (B) Official key: B

  1. The zero is at and the pole at . Maximum phase lead occurs at their geometric mean: .
  2. The asymptotic magnitude rises at 20 dB/decade from , so at it is dB.
  3. , and . Option (B): 2, 4.

Check all four: (A) gives but dB; (C) gives rad/s; (D) gives but only dB. The exact (not asymptotic) gain at would be too, by symmetry, so 6 dB holds either way here.

Where this shows up in industry

Lead compensators add phase margin near crossover; the maximum lead ( for ) is placed right at the new crossover frequency. Power-supply designers do the same thing with the 'Type 2' and 'Type 3' compensator networks around an op-amp error amplifier.

GATE 2024 · EE · Q.59NAT · 2 marksCompensators and controller design

Integral controller KI/s with tabulated G(jω): what KI gives a 50° phase margin?

Consider the stable closed-loop system shown in the figure. The magnitude and phase values of the frequency response of are given in the table. The value of the gain for a 50° phase margin is _______ (rounded off to 2 decimal places).
in rad/secMagnitude in dBPhase in degrees
0.5−7−40
1.0−10−80
2.0−18−130
10.0−40−200
Unity negative feedback loop with forward blocks K I over s and G(s) in seriesR(s)+−KᵢsG(s)C(s)

Answer: 1.12 Official key: 1.11 to 1.13

  1. Loop transfer function . The integrator adds at every frequency.
  2. A 50° phase margin needs at the gain crossover, so : from the table, rad/s, where dB .
  3. Crossover means : , so .

Trap: picking the row with forgets the integrator's own . With the loop gain at 0.5 rad/s is exactly 1 and the phase is , which we recomputed from the table values.

Where this shows up in industry

Tuning from a measured frequency-response table is routine when no model exists: a network analyser gives magnitude and phase at a few frequencies, and the controller gain is chosen to hit a target phase margin (45° to 60° is typical) at crossover. Loop-tuning tools in drives and power supplies automate exactly this step.

GATE 2025 · EE · Q.65NAT · 2 marksCompensators and controller design

PD controller (1 + KD s) for 1000√2/(s(s+10)²): what KD gives 45° phase margin at 10 rad/s?

A controller of the form is to be designed for the plant as shown in the figure. The value of that yields a phase margin of 45° at the gain cross-over frequency of 10 rad/sec is ________________ (round off to one decimal place).
Unity negative feedback loop with forward blocks D(s) and G(s) in seriesR(s)+−D(s)G(s)C(s)

Answer: 0.1 Official key: 0.1 to 0.1

  1. Plant at : , and .
  2. A 45° phase margin needs , so the controller must add : , i.e. and .
  3. Check the crossover: , so . 10 rad/s really is the gain crossover.

The was chosen so that both conditions (phase and magnitude) hold with one unknown. If the magnitude check had failed, no single could meet the specification.

Where this shows up in industry

Derivative action adds phase lead, which is how quadcopter attitude loops, hard-disk head positioners and many servo axes get their damping. Real PD controllers filter the derivative term () so that sensor noise is not amplified without limit.

GATE 2023 · EE · Q.46NAT · 2 marksState-space models

State-space model with D = 1: at what input frequency is the steady-state output zero?

Consider the state-space description of an LTI system with matrices For the input, , , the value of for which the steady-state output of the system will be zero, is ___________ (Round off to the nearest integer).

Answer: 2 rad/s Official key: 2 to 2

  1. . Here and .
  2. , so .
  3. The steady-state output to is . It is zero when : , rad/s.

The system has transmission zeros at : it is a notch filter. The system is stable (double pole at ), so the transient dies out and only the zero-output steady state remains. Checked by sweeping from 0.001 to 10 rad/s.

Where this shows up in industry

Notch filters built this way cancel a known disturbance frequency: 50 Hz mains pickup in sensor signals, or a mechanical resonance in a drive shaft or robot arm. Drive firmware places a notch at the measured resonance so the speed loop can be tuned faster.

GATE 2025 · EE · Q.62NAT · 2 marksState-space models

A = [0 1; −2 −3]: what is the sum of the magnitudes of the poles?

Consider the state-space model , , where , , are the state, input and output, respectively. The matrices are given below The sum of the magnitudes of the poles is _______________ (round off to nearest integer).

Answer: 3 Official key: 3 to 3

  1. The poles are the eigenvalues of : .
  2. Poles at and . Sum of magnitudes 3.

Check that nothing cancels: has no zeros, so both eigenvalues really are poles of the transfer function. The matrix is in controllable canonical form, so the last row is just the characteristic polynomial's coefficients with the sign flipped.

Where this shows up in industry

Engineers read poles off a state matrix to check stability of everything from a battery thermal model to a quadrotor's linearised dynamics. In MATLAB this is eig(A); the canonical forms are what code generators and observer designs start from.

GATE 2026 · EE · Q.52MCQ · 2 marksState-space models

A = [a b; −a 0]: which a and b put the transfer-function poles at −2 ± j3?

A system is characterized by the following state equation and output equation (: input, : state vector, : output) What are the values of and for which the poles of the transfer function are at and ?
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (D) Official key: D

  1. .
  2. Required: .
  3. Match coefficients: ; . Option (D).

We also checked that no pole is cancelled by a zero of for this choice, so really are poles of the transfer function. Sign slips on give (A) or (C); option (B) has .

Where this shows up in industry

Choosing matrix entries to place poles is the idea behind state-feedback design (pole placement, Ackermann's formula): the gains of an inverted-pendulum robot or an active suspension are computed so the closed-loop eigenvalues land where the designer wants them.

GATE 2026 · EE · Q.53MCQ · 2 marksState-space models

New state z = T x with T = [2 1; −1 0]: what are the transformed A, B and C?

A system is represented in state-space form as follows: (: input, : state vector, : output) Consider the new state vector . What is the state-space representation of the system in terms of the new state vector ?
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (C) Official key: C

  1. With : and .
  2. , so .
  3. , then .
  4. and . Option (C).

Option (A) is the classic slip: it uses and forgets the on the right. Quick check without full multiplication: a similarity transform keeps the trace and determinant of (trace 1, determinant 6). (C) has trace and determinant ; (A) has trace . We also confirmed both models give the same transfer function.

Where this shows up in industry

Changing state coordinates is how engineers move a model into the form a design method needs (controllable or modal canonical form) or into physically meaningful states. Field-oriented control of AC motors is a famous example: the Park transform turns three oscillating phase currents into two steady d-q currents a PI loop can regulate.

From GATE prep to a controls career

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.