ETABS Explained: Uses, Workflow, IS Codes and Why Civil Engineers Learn It

ETABS is CSI's building analysis and design program. This guide covers what it is used for, the latest version (v23.3.2, September 2026), the modelling workflow with IS 875, IS 1893 and IS 456 load combinations, the drift, base shear and modal mass checks, licence prices and student access, and a worked IS 1893 example for a G+2 frame in Delhi.

ETABS Explained: Uses, Workflow, IS Codes and Why Civil Engineers Learn It

ETABS is a program for modelling, analysing and designing buildings. You draw a building storey by storey: grids, columns, beams, slabs and walls. ETABS then applies the dead, imposed, wind and earthquake loads. It reports how the building sways and designs every member to codes such as IS 456 and IS 800. Civil engineers learn it because most structural design jobs for Indian buildings involve these exact tasks: IS 1893 seismic analysis, storey drift checks and RC design.

In short

  • ETABS is building analysis and design software from Computers and Structures, Inc. (CSI), Walnut Creek, California. It began as a UC Berkeley research program in 1975.
  • Latest version: ETABS v23. The newest release is v23.3.2, with release notes dated 21 September 2026. From v23.0.0 (13 October 2025), every licence is a cloud sign-in licence (CSI release notes).
  • Indian codes built in: IS 1893 (Part 1):2016 seismic loads and response spectra (since v17, June 2018), IS 875 (Part 3):2015 wind loads (since v16.1, April 2017), and design to IS 456, IS 13920, IS 800 and IS 11384 (CSI enhancements list).
  • Price: CSI lists perpetual licences at USD 7,439 (Plus), 11,903 (Nonlinear) and 17,855 (Ultimate). Universities can ask for academic pricing for campus labs. CSI lists no individual student licence (csiamerica.com/sales, checked 17 Nov 2026).
  • Worked example below: for a G+2 RC frame in Delhi, IS 1893 gives a 251 kN base shear. The response spectrum result is 199 kN and has to be scaled up by 1.26. The worst storey drift is 3.7 mm against a 12.8 mm limit. Every number is computed by a script.

Courses: compare every Skill-Lync ETABS course in one table, with fees, duration, projects and which one fits high-rise, seismic or composite design. For RCC, steel and bridge design beyond one tool, see all 28 structural design courses.

This guide, rewritten in November 2026, covers what ETABS is, its uses, the latest version, the modelling workflow with Indian load combinations, the results engineers check, licensing and jobs, with a worked IS 1893 example you can check by hand.

What is ETABS?

ETABS is CSI's integrated package for the structural analysis and design of buildings. CSI calls it "the industry standard for building design". It is built only for multi-storey buildings such as apartments, offices, hospitals and towers. It is not a general structural program, and that focus is what makes it fast for building work.

The name goes back to a 1975 University of California, Berkeley report, Three Dimensional Analysis of Building Systems (extended version), report UCB/EERC 75-13, by Edward L. Wilson, J.P. Hollings and H.H. Dovey. It followed TABS (1972), and "ETABS" is usually expanded as Extended Three-dimensional Analysis of Building Systems. CSI was founded the same year, 1975, and also makes SAP2000 (general structures), SAFE (slabs and foundations), CSiBridge and PERFORM-3D.

Its speed came from one idea: treat each floor as a diaphragm that is rigid in its own plane, and connect the frames and walls through those floors. A 1983 report to the US National Science Foundation describes this approach and its storey-by-storey results (deflections, drifts, shears, overturning moments), which is still how ETABS reports a building.

Today you draw a physical model of columns, beams, slabs and walls. When you press Run, ETABS builds the analytical model (the finite element mesh) from it automatically. Think of it as an architect's floor plans with structural engineering built in: you never type node coordinates.

What is ETABS used for?

ETABS is used to analyse and design RC, steel and composite buildings for gravity, wind and earthquake loads. It produces member sizes, reinforcement, drift and base-shear checks, design reports and detailing drawings. In India, its main use is designing residential and commercial buildings to IS 1893, IS 456 and IS 13920, from G+3 apartments to high-rise towers.

  • Seismic analysis: equivalent static and response spectrum analysis to IS 1893, time history analysis, and pushover analysis for performance-based design (in the higher licence levels).
  • Wind analysis: automatic wind loads to IS 875 (Part 3):2015.
  • Member design and reports: steel and concrete frames, slabs, shear walls, composite beams and columns, steel joists.
  • Detailing: rebar detailing for beams, columns and slabs, with drawing sheets for print or export.
  • Special systems: link elements for base isolators and dampers, nonlinear hinges, staged construction, and P-delta and buckling analysis.
  • BIM exchange: import and export with Revit (through CSI's two-way CSiXRevit plug-in), Tekla Structures, AutoCAD DXF/DWG and IFC.

CSI says its software was used to design the Taipei 101 tower and One World Trade Center. That claim covers CSI software in general, not ETABS by name. For sheds, pipe racks, towers and bridges, engineers usually use SAP2000 or STAAD.Pro instead: see ETABS vs SAP2000 and other tools and ETABS vs STAAD.Pro.

What is the latest version of ETABS?

The latest version is ETABS v23. Its newest release, v23.3.2, has release notes dated 21 September 2026, and CSI's enhancements page gives 23 September 2026 for the v23.3 releases. CSI released v23.0.0 on 13 October 2025 as a major version. When we checked on 17 November 2026, CSI had not listed a v24.

What changed in v23:

  • Licensing: "standalone, network, and cloud key licensing options have been removed from ETABS v23". You now sign in with a CSI account. For machines with no internet, CSI added remote checkout.
  • FEM buckling: steel members can be turned into detailed shell models, so ETABS finds local and global buckling modes. This needs the Ultimate licence.
  • SAFE to ETABS: a SAFE slab or foundation model can now be imported into ETABS at a chosen storey.
  • New codes: ACI 318-25 (v23.0), Eurocode 2023 and NBCC 2025 (v23.2.0, 24 February 2026).
  • New output: v23.3 adds a Story Inertial Forces table for modal and response spectrum cases, replacing section cuts.
  • Indian code fixes: v23.3.2 fixes an IS 456:2000 shear wall design error that affected walls with height-to-length ratios above 3 in v23.3.0 and v23.3.1. If you are on either of those, update.

An older article here promised "energy-efficiency analysis" tools; we found no such feature in CSI's enhancement history from v16 to v23.

Timeline of ETABS milestones: 1975 Berkeley report EERC 75-13; April 2017 v16.1 IS 875 Part 3 wind loads; June 2018 v17.0 IS 1893:2016 seismic loads and IS 13920:2016; March 2022 v20.1 Indian steel sections; November 2023 v21.2 cloud sign-in; October 2024 v22.2 IS 11384 composite beams; October 2025 v23.0 cloud sign-in only; September 2026 v23.3.2 latest
ETABS milestones for Indian users, from CSI's release notes and enhancement history. Dates are release dates as CSI lists them.

How do you model a building in ETABS, step by step?

An ETABS job has eight steps. Set up grids and storeys. Define materials and sections. Draw the members and assign floor diaphragms. Apply loads and set the mass source. Add seismic cases and load combinations. Run the analysis. Check drift, base shear and modal mass. Then design and detail the members. Steps 7 and 8 usually send you back to resize members, so you go round the loop more than once.

Flow chart of the eight ETABS steps: grids and storeys, materials and sections, draw objects and diaphragms, loads and mass source, IS 1893 seismic cases and combinations, run analysis, check modal mass, base shear and drift, then design to IS 456, IS 13920 and IS 800, with a loop back from design to sections
The ETABS workflow for an Indian RC building. Blue steps build the model, amber steps load, analyse and check it, and the green step designs it.

1. Grids and storeys

Start from a template or a blank grid: grid spacing, number of storeys, storey heights. Because ETABS recognises storeys, work drawn on one floor can be repeated on similar floors, which is where it saves the most time.

2. Materials and sections

Define concrete grades (M25, M30), rebar (Fe 500) and steel; Tata, Jindal and APL Apollo section databases are built in since v20.1. Then define beam, column, slab and wall sections (Section Designer handles odd shapes).

3. Draw objects, assign diaphragms and supports

Draw columns, beams, slabs and shear walls on the grid. Give each floor a rigid, semi-rigid or flexible diaphragm; a rigid one moves the whole floor as one plate, which is how most RC slabs behave. Set supports (usually fixed). Then check that joints connect and warnings are cleared: an error here spoils every later result.

4. Loads and the mass source

Assign dead load (self-weight is automatic), finishes, wall loads and imposed loads from IS 875 Parts 1 and 2. Wind loads to IS 875 (Part 3):2015 come from your city's basic wind speed and the terrain and topography factors.

Then set the mass source: the weight ETABS shakes in an earthquake. IS 1893 Table 10 takes 25% of imposed load up to 3 kN/m² and 50% above that. Clause 7.3.2 ignores imposed load on the roof. Get this wrong and the periods and base shear are wrong too.

5. Seismic cases and load combinations

Add IS 1893:2016 auto-seismic load patterns in X and Y, with the zone factor, soil type, importance factor and response reduction factor. Add response spectrum cases using the built-in IS 1893 spectrum. Then build the design combinations.

Type the combinations yourself or use Add Default Design Combos for the selected code, then check them; CSI's help notes you still choose the design combinations from the Design menu. The usual limit-state set for an Indian RC building:

CombinationSourceWhat it governs
1.5 (DL + IL)IS 456 Table 18Gravity design of beams and slabs
1.2 (DL + IL ± EL)IS 1893 cl. 6.3Earthquake with imposed load
1.5 (DL ± EL)IS 1893 cl. 6.3Earthquake, little imposed load
0.9 DL ± 1.5 ELIS 1893 cl. 6.3Uplift, column tension, overturning
Same set with WL in place of ELIS 456 Table 18, IS 875Wind, often governing for tall, light buildings

If the lateral load-resisting elements are not along two perpendicular directions, IS 1893 clause 6.3.2.2 replaces EL with 100% of the load in one direction plus 30% in the other.

6. Run the analysis

The standard set is linear static, modal (eigen or Ritz vectors) and response spectrum analysis, usually with P-delta on. P-delta is a second-order effect: a column carrying axial load P that sways by Δ picks up an extra moment of about P × Δ, so the building sways a little more. Tall, slender buildings feel it most.

The Nonlinear and Ultimate licence levels add nonlinear analysis, such as pushover and nonlinear time history.

7. Check the building

Check storey drift, modal mass participation, base shear scaling and the irregularities in IS 1893 Table 6 before designing anything (explained below).

8. Design and detail

Run concrete frame design to IS 456:2000. Since v17 that design includes IS 13920:2016 ductile detailing, which IS 1893 clause 6.3.1.1 makes mandatory for earthquake design. Steel frames are designed to IS 800:2007, and composite beams and columns to IS 11384:2022. Shear walls and slabs can also be designed to IS 456.

Resize failing members and rerun. Rafts and slabs usually go to SAFE.

Which Indian codes does ETABS support?

ETABS supports IS 1893 (Part 1):2016 seismic loads and IS 875 (Part 3):2015 wind loads, and designs to IS 456:2000 (frames, slabs, shear walls), IS 13920:2016 (within IS 456 frame design), IS 800:2007 (steel) and IS 11384:2022 (composite), per CSI's enhancement history and design-code list.

Indian StandardWhat ETABS does with itAdded in
IS 1893 (Part 1):2016Auto seismic loads and response spectrum functionsv17.0.0 (3 Jun 2018)
IS 875 (Part 3):2015Auto wind loadsv16.1.0 (7 Apr 2017)
IS 456:2000Concrete frame, slab and shear wall designListed on CSI's design code page
IS 13920:2016Ductile detailing checks inside IS 456 frame designv17.0.0
IS 800:2007Steel frame designListed on CSI's design code page
IS 11384:2022Composite beam and composite column designv22.2.0 (Oct 2024), v22.6.0 (Jul 2025)

Which IS 1893 edition applies? BIS released a revised earthquake code in late November 2025, with a new Zone VI along the Himalayan arc. In March 2026 it was reported withdrawn after the Ministry of Housing and Urban Affairs raised concerns about cost and consultation, and IS 1893 (Part 1):2016 is back in force. Vision IAS, summarising The Economic Times, cites a 3 March gazette notification that we could not read ourselves, so confirm the edition with your approving authority. ETABS implements the 2016 code, as does our example.

What results do engineers check in ETABS?

The three results checked on almost every building are storey drift, base shear and modal mass participation. Drift must stay within 0.004 times the storey height. The response spectrum base shear must be scaled up if it falls below the code base shear. The modes you include must capture at least 90% of the seismic mass in each direction.

  • Storey drift: one floor's sideways movement relative to the floor below. IS 1893 cl. 7.11.1.1 limits it to 0.004 × storey height at load factor 1.0 (12.8 mm for a 3.2 m storey).
  • Base shear: the total horizontal earthquake force at the foundation, reported for the static case and each response spectrum case (cl. 7.7.3 scaling).
  • Modal participating mass ratios: how much mass each mode shakes; cl. 7.7.5.2 needs 90% in each direction (the UX and UY columns).

Worked example: IS 1893 base shear, modal mass and storey drift for a G+2 frame

To see what ETABS computes, we solve the problem in a short Python script. It uses the IS 1893 equivalent static method, then a frame model solved by the direct stiffness method (the matrix method ETABS's solver also uses), then modal and response spectrum analysis. Every number below comes from that script, kept with this article's working files.

The building (assumptions)

  • G+2 RC special moment resisting frame (SMRF) in Delhi: three storeys of 3.2 m (height h = 9.6 m), a 12 m × 12 m plan, and 3 × 3 bays of 4 m. That gives 16 columns, and four identical frames resist shaking in each direction.
  • Zone IV (Z = 0.24, since IS 1893 Annex E lists Delhi in Zone IV), medium soil (Type II), residential with up to 200 occupants (I = 1.0), SMRF (R = 5.0).
  • Floors carry 10 kN/m² all-in dead load (slab, finishes, beams, columns and walls) plus 2 kN/m² imposed load. The roof carries 8 kN/m² dead load.
  • Columns 400 × 400 mm, beams 300 × 450 mm, M25 concrete, E = 5000√fck = 25,000 MPa (IS 456 cl. 6.2.3.1). Cracked stiffness per IS 1893 cl. 6.4.3.1: 70% of gross inertia for columns and 35% for beams. Fixed bases. Accidental torsion is ignored here, although ETABS adds it.

Step 1: Seismic weight

Each floor weighs 144 m² × (10 + 0.25 × 2) = 1,512 kN, and the roof 144 × 8 = 1,152 kN:

Step 2: Period and design acceleration

For a bare RC moment frame, clause 7.6.2(a) gives:

For medium soil, Sa/g = 2.5 for periods from 0.10 to 0.55 s, so Sa/g = 2.5. Clause 6.4.2 then gives the design horizontal seismic coefficient:

Step 3: Base shear and its distribution

That is well above the Table 7 minimum for Zone IV, 1.6% of W = 66.8 kN. Clause 7.6.3 shares VB between the floors in proportion to Wihi²:

Levelhi (m)Wi (kN)Qi (kN)Storey shear (kN)Storey drift (mm)
Roof (3)9.61,152144.9144.92.6
26.41,51284.5229.43.7
13.21,51221.1250.62.5

The storey forces add up to 250.5 kN because of rounding. The script carries full precision.

Step 4: Storey drift check

Each of the four frames carries a quarter of the storey forces. Solving one frame gives floor displacements of 2.5, 6.2 and 8.9 mm, so the storey drifts are 2.5, 3.7 and 2.6 mm. The limit is 0.004 × 3,200 mm = 12.8 mm. The worst storey, storey 2, uses 29% of it. As a drift ratio, the form ETABS's Story Drifts table uses, that is 3.7 / 3,200 = 0.0012 against 0.004.

Three-storey, three-bay frame with IS 1893 storey forces of 21.1, 84.5 and 144.9 kN and storey shears of 250.6, 229.4 and 144.9 kN; bar chart of storey drifts of 2.5, 3.7 and 2.6 mm against a 12.8 mm limit
Equivalent static forces, storey shears and drifts for the example frame. Drifts come from a cracked-section frame model with a rigid floor diaphragm.

Step 5: Modal analysis and the 90% mass rule

The modal analysis gives three sway modes, with periods of 0.587 s, 0.180 s and 0.101 s. Mode 1 moves 84.5% of the mass, mode 2 moves 12.0% and mode 3 moves 3.5%. Mode 1 alone is below the 90% required by clause 7.7.5.2, so the response spectrum analysis must include at least two modes (96.5%).

A real 3D ETABS model also has torsional modes. You request more modes, or use Ritz vectors, until the UX and UY sums both pass 90%.

Three mode shapes of the example frame with periods 0.587, 0.180 and 0.101 seconds and modal mass of 84.5, 12.0 and 3.5 percent; cumulative bars of 84.5, 96.5 and 100 percent against a 90 percent line
What the Modal Participating Mass Ratios table means. The first mode alone does not reach the 90% that IS 1893 asks for.

The computed first-mode period, 0.587 s, is 1.44 times the formula's 0.409 s. That is normal for a bare-frame model without the infill walls that stiffen a real building. It moves mode 1 past the spectrum's 0.55 s corner, so Sa/g falls to 1.36 / 0.587 = 2.32.

Step 6: Response spectrum base shear and scaling

Each mode's base shear is Ah for that mode's period times its modal mass. The three modes give 196.2, 30.1 and 8.7 kN. Combining them by CQC (complete quadratic combination, IS 1893 cl. 7.7.5.3) gives:

So clause 7.7.3 applies. Every force result from the response spectrum case (storey shears, member forces, base reactions) has to be multiplied by:

In ETABS you do this by multiplying the response spectrum case's scale factor by this ratio, rerunning, and confirming that the base reaction now matches.

Displacements are treated differently. Since Amendment 2 (2020), clause 7.7.3.2 says displacement results need not be scaled, and clause 7.11.1.2 says the dynamic drift estimates are not scaled. The unscaled response spectrum drifts here are 1.9, 2.6 and 1.7 mm, all below the static ones.

IS 1893 medium soil spectrum with code period 0.41 s on the 2.5 plateau and the computed first-mode period 0.59 s at Sa/g 2.32; bar chart of base shear: 251 kN static, 199 kN response spectrum, scaled by 1.26 to 251 kN, and a 67 kN code minimum
The response spectrum base shear (199 kN) is below the code value (251 kN), so IS 1893 clause 7.7.3 scales the dynamic forces up by 1.26.

Forgetting this scaling is a classic ETABS mistake and a common interview question: the software reports both numbers but does not force you to reconcile them. If your model's base shear is far from a hand estimate like this, check the mass source, the period option and R.

Is ETABS free for students, and how much does it cost?

ETABS is not free, and CSI's sales page lists no individual student licence. It offers academic pricing to universities installing CSI software in campus labs. A faculty member has to request it, and a dean or department head has to confirm non-commercial teaching use. Commercial perpetual licences are listed in US dollars, and CSI's website also has a trial page for ETABS.

ETABS levelPerpetual licence (USD)Annual maintenance (USD)Adds
Plus7,4391,301Linear analysis (static, modal, response spectrum) and design
Nonlinear11,9032,081Nonlinear analysis, such as pushover and nonlinear time history
Ultimate17,8553,128The full feature set, including FEM buckling (v23)

These prices are from csiamerica.com/sales, accessed 17 November 2026. They are a US list-price snapshot that excludes Indian taxes and can change. The "Adds" column is a simplified summary, so check CSI's level comparison for the features your work needs.

In India, CSI lists CSI Engineering Software Private Limited, New Delhi, as its channel partner for India, Nepal and Bhutan. Ask them for a rupee quote or about your college's lab licence. Avoid cracked copies. Since v23 every genuine licence runs through cloud sign-in, and design results from unlicensed software are a legal and professional risk for you and your employer.

Why should civil engineers learn ETABS?

Civil engineers learn ETABS because designing buildings for Indian seismic codes is its core job. Storey-based modelling, built-in IS 1893 loads and spectra, and IS 456 and IS 13920 design are exactly what building design offices deliver. A fresher who can build, check and defend an ETABS model is useful on live projects from the start.

  1. Seismic design is routine in India. IS 1893 Table 9 requires RC and steel structures in Zones III, IV and V to be designed as ductile, and IS 1893 Annex E puts cities such as Delhi (Zone IV) and Guwahati (Zone V) in those zones. ETABS automates the code loads, the 90% modal mass check, the scaling and the drift tables, which are tedious and error-prone by hand.
  2. It moves you from drafting to design. In Skill-Lync's placement records, civil design and structural roles pay more than graduate trainee roles. Civil design engineers had a median starting offer of 2.75 LPA (n = 61), structural and civil engineers 3.0 LPA (n = 94), and civil graduate engineer trainees 2.4 LPA (n = 123).
  3. The skills transfer. Diaphragms, mass source, cracked sections and spectrum scaling work the same way in STAAD.Pro and SAP2000.

About these figures: they come from 3,711 Skill-Lync placement records up to 7 November 2026 (data snapshot of 15 November 2026). This is a self-selected sample of learners who reported a placement. Most offers are starting salaries from 2021 to 2023, and recent years have few records, so treat the figures as a starting point, not a market survey. The civil engineer salary page breaks them down further.

Typical roles are structural design engineer, structural engineer (analysis and checking) and RC detailing engineer; see jobs for civil engineers based on ETABS.

There is a catch: ETABS will happily analyse a wrong model and print confident numbers. Employers test whether you can explain the output, such as why the period differs from the formula, why forces were scaled and what governs a column. The worked example above is the real skill; the software is the tool. The theory behind it is in Skill-Lync's Strength of Materials book and the solved GATE questions on concrete structures and steel structures.

How long does it take to learn ETABS?

Most engineers can model, load and analyse a simple RC building in ETABS within a few weeks of regular practice. Designing a full building to IS 1893, IS 456 and IS 13920, and defending every check, usually takes a structured course and two or three complete projects. Skill-Lync's short ETABS courses run 12 to 14 weeks, with two industry projects each.

A sensible order: analysis basics (load paths, bending moment, stiffness); one G+3 RC building end to end with gravity loads; the same building with IS 1893 seismic loads, scaling and drift, compared with a hand calculation like the one above; IS 456 and IS 13920 design; then a taller shear-wall building with IS 875 wind.

The high-rise building design course with ETABS and SAFE follows this path, and its projects include a Zone V hostel building in Guwahati. Before interviews, read our ETABS interview questions and the interview questions hub. The post on stiffness modifiers in ETABS explains the cracked-section factors used in Step 4.

Frequently asked questions

What is the full form of ETABS?

ETABS is usually expanded as Extended Three-dimensional Analysis of Building Systems. The name comes from the 1975 UC Berkeley report "Three Dimensional Analysis of Building Systems (extended version)" by Wilson, Hollings and Dovey, which followed the earlier TABS program (1972).

Can ETABS design foundations?

ETABS gives you the base reactions, and it can design composite and RC members above the foundation. Rafts, mats and slabs are usually designed in SAFE, CSI's slab and foundation program. Since v23, a SAFE model can also be imported back into ETABS at a chosen storey.

Which version of ETABS should I learn in 2026?

Learn on v23, the current major version. Its latest release is v23.3.2 (September 2026). IS 1893:2016 support has been in ETABS since v17 (2018), and the core modelling steps are the same in recent versions, so v20 to v22 tutorials remain useful. Expect differences in licensing and in the code options offered.

Does ETABS follow IS 1893:2016 automatically?

It generates IS 1893:2016 seismic loads and spectra from your inputs. It does not check that your inputs are right, it does not scale the response spectrum results to the static base shear unless you set the scale factor, and it does not choose the code edition your authority requires. Those are the engineer's job.

Sources and further reading

Want this on your résumé?

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.