Explain the results in a detailed manner.

*************************************************************

  • Grid Dependency Test:-In grid dependency test three different mannual global mesh is used as given in table
Case-1Case-2Case-3
Nx3060120
Ny3060120
Nz122448
  1. For Case-1 Velocity Cut Plot:-

2. For Case-2 Velocity Cut Plot:-

3. For Case-3 Velocity Cut Plot:-

  • Conclusion

Comparing the above three figures,we can see the third case shows a better results in terms of velocity variation,So third case is chossen for further analysis.

Effect of valve lift on mass flow rate

VALVE-LIFT(in m)MASS FLOW RATE
0.001-0.17505
0.002- 0.31334
0.003-0.45402
0.004 -0.5931
0.005 -0.71367
0.006 -0.83103
0.007-0.90207
0.008 -0.96003

* negative sign shows that mass is leaving from the system

  • Plot of Valve Lift vs Mass flow rate:-

  • Velocity Distribution for lift-0.001 m

  • Velocity Distribution for lift-0.002 m

  • Velocity Distribution for lift-0.003 m

  • Velocity Distribution for lift-0.004 m

  • Velocity Distribution for lift-0.005 m

  • Velocity Distribution for lift-0.006 m

  • Velocity Distribution for lift-0.007 m

  • Velocity Distribution for lift-0.008 m