Valve Cv and Kv calculator: flow coefficient, K and the gate valve CFD study

Type a flow and a pressure drop and get the valve's Kv and Cv, or give a Cv or Kv and get the flow or the pressure drop. It also turns either into the loss coefficient K for your pipe bore. Free, no sign-up, runs in your browser.

The second tab is for the gate valve parametric study of Skill-Lync's Ansys Fluent course. It shows how much of the 10 Pa the valve really takes at each lift, and the valve's own Kv next to the one worked out from the whole rig. The third tab checks the Kv and Cv in your report.

ISA-75.01 / IEC 60534 · Crane TP-410 · Ansys Fluent guide · 523 reports read · Updated 20 Nov 2026

Kv31.62m³/h at 1 bar
Cv36.56US gpm at 1 psi
K in a 50 mm bore10velocity heads lost
  • Velocity in the 50 mm bore 2.83 m/s; Δp = 10 × ½ρv².
  • Kv = Q·√(SG/Δp) with Q in m³/h and Δp in bar; Cv = 1.156 × Kv.

What are Cv and Kv?

A valve's flow coefficient says how much water it passes for a given pressure drop. It is the one number valve makers publish so you can size a valve without knowing its insides. Cv is the US version and Kv the metric one:

Kv, with Q in m³/h and Δp in bar:

Cv, with Q in US gallons per minute and Δp in psi:

SG is the liquid's specific gravity, 1 for water. Flow goes with the square root of the pressure drop, so a valve with Kv = 31.6 passes 31.6 m³/h at 1 bar and half that at 0.25 bar. Because the two differ only in units, the conversion is fixed:

1.156 comes straight from the units: one m³/h is 4.403 US gpm, and 1 bar is 14.50 psi, so Cv/Kv = 4.403/√14.50. The formula is for liquids that don't flash or cavitate. Gases, choked flow and the piping corrections of IEC 60534-2-1 are beyond this page.

Cv, Kv and the loss coefficient K

Pipe-flow calculations write a fitting's loss in velocity heads instead: the pressure drop is K times the dynamic pressure of the flow in the pipe. Since the velocity depends on the bore, K and Kv can only be converted for a given diameter:

The second form is Crane's (Technical Paper 410), with d the bore in inches. Worked from the metric definitions with water at 999 kg/m³, the constant comes out 29.84, within 0.2% of Crane's 29.9. The metric equivalent is Kv = 0.04 d²/√K with d in millimetres (IEC 60534-2-1 lists both as its N₂ constants). A valve with Kv = 100 m³/h in a 100 mm line has K = 16. A fitting with K = 1 in the same line has Kv = 400 m³/h.

The gate valve challenge: what the 10 Pa really measures

In the gate valve parametric study of Skill-Lync's Ansys Fluent course, the valve sits in a 100 mm line with 800 mm of pipe added on each side. Water enters through a pressure inlet at 10 Pa total gauge pressure and leaves through a pressure outlet at 0 Pa. Workbench steps the gate lift from 10 to 80 mm, the mass flow is read at the outlet, and a Kv and Cv are worked out with Δp = 10 Pa.

Skill-Lync read all 523 public reports on 20 Nov 2026. 249 state the 10 Pa inlet. 153 give the mass flow at six or more lifts, and they agree closely: the median is 0.148 kg/s at 10 mm (middle half 0.142 to 0.150) and 0.785 kg/s at 80 mm (0.766 to 0.801).

A total-pressure inlet and a static-pressure outlet don't put the 10 Pa across the valve. The energy equation for the rig has three sinks: the kinetic energy the water carries out of the outlet, friction in the 1.6 m of pipe, and the valve:

Put the median flows in and the valve's share falls as it opens. At 10 mm it takes 97% of the 10 Pa. At 50 mm it takes 60%, and at 80 mm only 25%, while the outlet's kinetic energy takes 50%:

Share of the inlet total pressure taken by the valve, the pipe friction and the outlet kinetic energy at each gate lift0%25%50%75%100%1020304050607080valvepipe frictionoutlet kinetic energygate lift (mm)
Lift (mm)ṁ (kg/s)KvalveValve shareKv, 10 PaKv, valve
100.148554.397%53.5354.29
200.238620.193%86.0389.24
300.36137.8283%130.3143.1
400.47004.0172%169.4199.9
500.56312.3460%203261.4
600.64711.4248%233.3335.7
700.71790.88337%258.8425.8
800.78540.50225%283.2564.8

Fluent water-liquid (998.2 kg/m³, 0.001003 Pa·s), outlet kinetic energy taken as one velocity head of the mean velocity, smooth-pipe friction (64/Re laminar, Colebrook above Re 4,000). Pipe Reynolds number 1,885 at 10 mm to 9,971 at 80 mm. Mass flows: median of the 153 reports.

So the Kv worked out from the 10 Pa is the whole rig's. At 10 mm it is within 1% of the valve's own, but at 80 mm the valve alone has twice the Kv the reports quote, 564.8 against 283.2. It also explains why the flow-against-lift curve flattens. With the gate removed altogether, 10 Pa can only push 0.914 kg/s through the pipe, and 80 mm already reaches 86% of that.

Kv against gate lift: worked out from the 10 Pa across the whole rig and for the valve alone02004006008001000020406080Kv from the inlet pressure (rig)valve onlyhandbook Kgate lift (mm)Kv (m³/h)

The split is an estimate. Downstream of a part-open gate the jet takes several diameters to spread, so the outlet profile isn't uniform and the friction isn't fully developed. Both make the real valve share a little smaller still. To measure a Kv that compares with a valve maker's, do what the test standards do. IEC 60534-2-3 and ISA-75.02 take the pressure difference between static taps 2 pipe diameters upstream and 6 downstream of the valve, with at least 18 diameters of straight pipe before the upstream tap. The rated coefficient includes the friction of the pipe between the taps; nothing is subtracted. In Fluent, move the inlet well upstream and read the area-averaged static pressure on planes at 2D and 6D.

As a cross-check, the Degrémont (SUEZ) Water Handbook lists the loss coefficient of a gate valve at eighths of its travel. Around half open the two agree: the handbook gives K = 2.06 at 50 mm against 2.34 from the reports, and 4.53 against 4.01 at 40 mm. Towards the ends they part, 34.3 against 20.1 at 20 mm and 0.209 against 0.502 at 80 mm. That is where this estimate is weakest (laminar pipe flow at small lifts, a jet that hasn't spread at the outlet at large ones), and the course's valve body isn't the handbook's. The table stops at 1/8 open, so it has nothing to say about the 10 mm case. The grey squares on the chart are the handbook values turned into Kv for the 100 mm bore.

The unit slips that wreck most Kv and Cv tables

Of the 132 reports whose Kv or Cv table Skill-Lync could match automatically to their own mass flows at Δp = 10 Pa, 63 left Δp in pascals in at least one of the two. With 10 Pa as 10 instead of 0.0001 bar, the Kv comes out √100,000 = 316 times too small. The Cv comes out √6,895 = 83 times too small. (The match looks for a printed value equal to the report's own mass flow times the formula's factor, on at least two lifts. Made-up factors matched at most 6 reports, so the counts are not chance. Reports that used another Δp aren't counted.)

  • Δp in Pa. Kv takes bar and Cv takes psi. For the challenge that is 0.0001 bar and 0.00145 psi.
  • Q in m³/s. Kv takes m³/h, 3,600 times more.
  • Gallons per hour. Some reports turn m³/s into US gallons per hour and call it gpm, so the Cv is 60 times too big.
  • kg/s as m³/s. The outlet report gives mass flow. Divide by 998.2 for the volume flow.
  • Cv and Kv swapped. Cv is always the bigger number, 1.156 × Kv.

The check tab catches each of these from your mass flow and the Kv or Cv you printed.

What this calculator does not cover

  • Gases and steam. Compressible flow uses expansion factors and choked-flow limits (IEC 60534-2-1); the liquid formula overestimates gas flow at large pressure ratios.
  • Cavitation and flashing. At large drops the flow chokes when the vena contracta pressure falls to the vapour pressure; the square-root law stops holding.
  • Piping geometry factors. Reducers next to the valve lower its effective Cv (the Fp factor of the standards).
  • Viscous liquids. At low valve Reynolds numbers the standards apply a viscosity correction. In the gate valve challenge the pipe Reynolds number at 10 mm lift is only about 1,885, laminar in the pipe, though the jet under the gate is much faster.
Learn CFD

Setting boundary conditions that measure what you think they measure, and turning a run into a number a valve engineer can use, is the work of a CFD engineer. The gate valve study is a project in Skill-Lync's Ansys Fluent courses.

Frequently asked questions

How do you calculate the Cv of a valve?

Cv is the flow of water in US gallons per minute that passes with a 1 psi drop: Cv = Q·√(SG/Δp) with Q in US gpm and Δp in psi. 20 m³/h of water (88.06 gpm) across 0.4 bar (5.80 psi) gives Cv = 36.56. The metric Kv uses m³/h and bar: Kv = 31.62 for the same valve, and Cv = 1.156 × Kv always.

What is the difference between Cv and Kv?

Only the units. Cv is US gallons per minute at 1 psi (60 °F water), Kv is cubic metres per hour at 1 bar (water at 5 to 40 °C). The ratio is fixed by the unit definitions: Cv = 1.156 Kv and Kv = 0.865 Cv. Some older European data define Kv at 1 kgf/cm², which gives a number about 1% lower.

How do I convert a valve's Cv to a loss coefficient K?

K is the pressure drop in velocity heads, Δp = K·½ρv², so it depends on the bore the velocity is taken in. Crane's TP-410 relation is Cv = 29.9 d²/√K with d in inches. In metric, K = 2Δp/(ρv²) with the flow that gives Kv at 1 bar: a Kv of 100 m³/h in a 100 mm bore is K = 16.

How do you find the flow coefficient of a valve in Ansys Fluent?

Run the valve with a known pressure difference, read the mass flow at the outlet, turn it into m³/h and use Kv = Q·√(SG/Δp). The pressure difference has to be across the valve: valve standards (IEC 60534-2-3, ISA-75.02) take it between static taps 2 pipe diameters upstream and 6 downstream, and the rated Cv includes the friction of that short length of pipe. In Fluent, read the area-averaged static pressure on planes at those positions. If you use the inlet's total pressure minus the outlet's static pressure, as the gate valve challenge does, the outlet's kinetic energy and the pipe friction are included: at 80 mm lift that is 75% of the 10 Pa.

Why does the mass flow stop rising as the gate valve opens?

Partly the valve: a gate valve's loss falls steeply over the first half of its travel and slowly after. But in the Fluent challenge most of the flattening is the rig. With the gate removed altogether, 10 Pa can only push 0.914 kg/s through the 100 mm pipe, because half the energy must leave the outlet as kinetic energy and the rest goes in pipe friction. At 80 mm lift the reports already reach 0.785 kg/s, 86% of that ceiling.

Why are my Kv values so small?

Usually Δp was typed in pascals. Kv needs bar: 10 Pa is 0.0001 bar, and √(1/0.0001) = 100, while √(1/10) = 0.316, so the Kv comes out 316 times too small. For Cv the factor is √6,895 = 83. Of the 132 gate valve reports whose tables Skill-Lync could match to the 10 Pa set-up, 63 left Δp in pascals in the Kv or the Cv.

Related on Skill-Lync

Sources

  • Cv: "one Cv equals the flow of one U.S. gallon per minute of water at 60°F" at a 1 psi drop, H. D. Baumann, Control Valve Primer (ISA), Ch. 5, p. 21. Kv: m³/h of water at 5 to 40 °C and a 1 bar drop, IEC 60534-1 and Spirax Sarco's control valve notes ("Cv (US) = Kv × 1.156099"). Kv = 0.865 Cv: Emerson Fisher Catalog 12, Section 2, p. 2-3.
  • Liquid sizing equation and constants (N₁ = 0.865 for m³/h and bar, 1.00 for gpm and psi; N₂ for the K relation, 890 with d in inches, 0.0016 for Kv with d in mm): IS/IEC 60534-2-1:1998 (identical to IEC 60534-2-1:1998), cl. 6.1.1.1 and Table 1. Flow coefficients "include all head losses between" the reference taps 2 and 6 pipe diameters either side of the valve (cl. 4, Fig. 1).
  • Test procedure: IS/IEC 60534-2-3:1997, Table 1 (taps 2D upstream and 6D downstream, at least 18D of straight pipe before the upstream tap, 1D after the downstream one) and cl. 9.3 (the coefficient from the tap-to-tap drop); ANSI/ISA-75.02 has the same table.
  • Cv = 29.9 d²/√K: Crane Technical Paper 410, as widely quoted (the page re-derives 29.84 from the unit definitions; Fisher's N₂ = 890 gives √890 = 29.83). Kv = 0.04 d²/√K for d in mm: Crane TP-410 M (2009), as cited in C. Bell's fluids library.
  • Gate valve loss coefficient at closures 0, 1/8 … 7/8: K = 0.12, 0.15, 0.26, 0.81, 2.06, 5.52, 17, 98, Degrémont / SUEZ Water Handbook, "Minor losses in the pipelines", Table 64. The usual textbook values (¼, ½, ¾ closed: 0.26, 2.1, 17) agree, e.g. C. Wassgren, Purdue ME 308 notes, "Pipe Flows – Head Losses".
  • Total pressure for incompressible flow, p₀ = ps + ½ρ|v|²: Ansys FLUENT 6.3 User's Guide, §7.3.3 (Eq. 7.3-17). Water-liquid density 998.2 kg/m³: Ansys Fluent 2024 R2 User's Guide, §8.3.4.1; viscosity 0.001003 kg/m·s as Fluent's material panel shows it in the course reports.
  • Darcy friction factor 64/Re below Re 2,300, transition to about 4,000, Blasius for 4,000 to 10⁵ (the calculator uses smooth-pipe Colebrook, which agrees with Blasius there): C. Wassgren, Purdue notes, Ch. 11. US gallon = 3.785411784 L (exact) and psi = 6,894.757 Pa: NIST Handbook 44 (2026), Appendix C.
  • Skill-Lync, all 523 public gate valve reports, read 20 Nov 2026: inlet and outlet conditions, bore and pipe lengths (23 quote a 100 mm bore, 162 the 800 mm extensions), mass flow at each lift, the Kv and Cv tables.
  • Skill-Lync, scripts/verify/gate-valve.py: re-derives the unit constants from their definitions, the smooth-pipe Colebrook factor by bisection, the energy split, the flow for a given valve K, and every slip in the check tab; the page checks itself against it at build time.
Free counselling

From a valve study to a CFD career.

Choosing boundary conditions, checking that a result means what the report says, and turning it into a number someone can size equipment with are the everyday work of a CFD engineer. A Skill-Lync counsellor can map the course that fits the role you want.

Talk to a CFD course counsellor

Free. We call you back, usually the same day.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.