GATE Instrumentation (IN): Sensors and Industrial Instrumentation (strain gauges, RTDs, thermistors, thermocouples, LVDT, capacitive, piezoelectric and Hall sensors, pressure, flow and level measurement), previous-year questions solved, part 2

Part 2 of 3 of the Sensors and Industrial Instrumentation hub: 13 more official GATE IN questions on capacitive, inductive, piezoelectric and Hall-effect sensors, each solved step by step and checked against the official answer key. The other parts cover resistive sensors: strain gauges, RTDs, thermistors and bridges, thermocouples, pyrometers and temperature measurement, pressure, force, torque, displacement, velocity and acceleration and flow, level and process variables (pH, conductivity, viscosity).

Questions from official GATE IN papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 19 Nov 2026 · 13 of 32 questions on this page

GATE 2022 · IN · Q.17MCQ · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

A Hall sensor is based on which principle: photoelectric, Seebeck, piezoelectric or Lorentz force?

A Hall sensor is based on the principle of ________
  1. (A)Photoelectric effect
  2. (B)Seebeck effect
  3. (C)Piezoelectric effect
  4. (D)Lorentz force

Answer: (D) Official key: D

  1. A current flows along a thin conducting or semiconducting strip, and a magnetic field is applied perpendicular to it.
  2. Each moving carrier feels the Lorentz force , which pushes it to one side of the strip. Charge builds up across the width until the transverse electric field balances the force: .
  3. The resulting Hall voltage is , where is the carrier density and the thickness. It needs only current and field: no light (photoelectric), no temperature difference (Seebeck) and no stress (piezoelectric).
  4. Answer: (D) Lorentz force.

Trap: Hall sensors are made of semiconductors, which suggests a photoelectric or other semiconductor effect. The working principle is the magnetic force on moving charge. For a strip with , mm, mA and T the force balance gives mV with no light, heat or stress applied, and zero when .

Where this shows up in industry

Hall sensors commutate brushless DC motors, sense gear-tooth speed in vehicles and measure current without contact in clamp meters and closed-loop current transducers. Low carrier density semiconductors are used because the Hall voltage is inversely proportional to n.

GATE 2023 · IN · Q.12MCQ · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

Coil reads 10 mH at 10 kHz; a pure copper sheet is brought near it: what does the LCR meter read now?

Inductance of a coil is measured as 10 mH, using an LCR meter, when no other objects are present near the coil. The LCR meter uses a sinusoidal excitation at 10 kHz. If a pure copper sheet is brought near the coil, the same LCR meter will read____________.
  1. (A)less than 10 mH
  2. (B)10 mH
  3. (C)more than 10 mH
  4. (D)less than 10 mH initially and then stabilizes to more than 10 mH

Answer: (A) Official key: A

  1. The coil's alternating field induces eddy currents in the copper sheet. By Lenz's law these currents set up a field that opposes the coil's flux.
  2. Treat the sheet as a shorted secondary with inductance and resistance , coupled by . The impedance seen at the coil is .
  3. The reflected term has a positive real part (extra loss) and a negative imaginary part, so the effective inductance is .
  4. Copper is non-magnetic (), so there is no extra flux path to raise the inductance. The meter reads less than 10 mH: option (A).

Trap: assuming any metal near a coil raises its inductance. That is true for a ferromagnetic object such as an iron sheet, whose high permeability concentrates the flux. A good conductor that is not magnetic only adds opposing eddy-current flux. Across the coupling and sheet values we tried, the model gave 7.500 to 9.9756 mH, always below 10 mH, with a steady value at 10 kHz.

Where this shows up in industry

Eddy-current proximity probes, used to monitor shaft vibration and axial position on turbines and compressors, work on this effect: a conductive target lowers the probe coil's effective inductance and raises its loss, and the driver converts that into a gap voltage. Coin validators and inductive metal detectors use the same coil-and-target interaction.

GATE 2023 · IN · Q.15MCQ · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

Parallel-plate C calculated as 20 pF from eps0 epsr A/d; ideal LCR meter, no cable error: likely reading?

Capacitance ‘’ of a parallel plate structure is calculated as 20 pF using , where is the permittivity of free space, is the relative permittivity of the dielectric, is the overlapping area of the electrodes and is the distance between them. The value of is then measured using an LCR meter. If the meter is assumed to be ideal and it introduces no error due to cable capacitance, which one of the following readings is likely to be correct?
  1. (A)20.5 pF
  2. (B)20 pF
  3. (C)19.5 pF
  4. (D)10 pF

Answer: (A) Official key: A

  1. assumes a perfectly uniform field confined to the overlap area. It ignores the field lines that bulge out around the edges of the plates (the fringing field).
  2. The fringing lines store extra energy and add extra charge on the plate edges for the same voltage, so the real capacitance is always somewhat larger than the formula value.
  3. With the meter and cables ideal, the reading should be a little above 20 pF: 20.5 pF, option (A). For square plates, Palmer's fringing formula gives an excess of 2.5% when the gap is about 0.48% of the plate side.

Trap: choosing 20 pF because the meter is ideal. The meter is ideal, but the formula is not: it is an approximation that always under-estimates. 19.5 pF would need the field to be weaker than uniform, and 10 pF is far off. We evaluated Palmer's correction for gap-to-side ratios from 0.001 to 0.1: the measured value exceeded the formula value in every case.

Where this shows up in industry

Capacitive displacement and level sensors surround the sensing electrode with a guard ring driven at the same potential, so the fringing lines end on the guard and the measured capacitance follows the ideal parallel-plate formula. Without a guard, the edge field also makes the sensor respond to objects beside the target.

GATE 2023 · IN · Q.52NAT · 2 marksCapacitive, inductive, piezoelectric and Hall-effect sensors

LVDT secondaries 2 V RMS each at null, one off by 1 degree in phase; 1 mV/um: zero-displacement output in um?

The two secondaries of a linear variable differential transformer (LVDT) showed a magnitude of 2 V (RMS) for zero displacement position of the core. It is noted that the phase of one of the secondaries has a deviation of one degree from the expected phase. Other than this deviation, the LVDT is ideal.

If the differential output sensitivity of the LVDT is 1 mV (RMS)/1 m, the output for zero displacement is __________ m (rounded off to one decimal place).

Answer: Official key: 34.5 to 35.5

  1. The two secondaries are connected in series opposition, so the output is the phasor difference .
  2. At the null position both have magnitude 2 V. In an ideal LVDT they are also in phase and cancel. Here one is shifted by : , .
  3. .
  4. With 1 mV per m, this residual null voltage looks like a displacement of .

Trap: answering 0 because the magnitudes are equal. Equal magnitudes cancel only if the phases match; the voltages subtract as phasors. Taking only the in-phase part, , gives 0.61 m and misses the quadrature part that dominates. We subtracted the two phasors directly and divided by the sensitivity.

Where this shows up in industry

Residual null voltage, caused by phase and harmonic imbalance between the secondaries, is a specified LVDT parameter. Phase-sensitive (synchronous) demodulation in the signal conditioner rejects most of the quadrature part, which is why it is used rather than a plain rectifier near the null.

GATE 2024 · IN · Q.15MCQ · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

Parallel plates with air gap d1 over a solid dielectric d2 (eps2): capacitance when d1 falls by delta d1?

The capacitor shown in the figure has parallel plates, with each plate having an area . The thickness of the dielectric materials are and and their relative permittivities are and , respectively. Assume that the fringing field effects are negligible and is the permittivity of free space.
If is decreased by , the resultant capacitance becomes
A parallel-plate capacitor of plate area A between two terminals. The top plate is movable and the bottom plate is fixed. Between them is an air gap of thickness d1 (relative permittivity epsilon1 = 1) above a solid dielectric of thickness d2 and relative permittivity epsilon2 resting on the fixed plateAd1d2Movable PlateAirε1 = 1Solid dielectricε2Fixed Plate
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (A) Official key: A

  1. The air layer and the solid layer carry the same flux density and sit one above the other, so they are two capacitors in series: with , and .
  2. , so .
  3. Only the movable plate moves, so only the air gap changes: while stays fixed. , option (A).

Trap: (D) adds (the gap increased instead of decreased), and (C) changes the solid layer, which is fixed to the bottom plate. (B) divides the air gap by , as if the two materials were swapped. We evaluated every option against the series-capacitor result for 20 random plate areas, gaps and permittivities: only (A) matched every time.

Where this shows up in industry

A thin solid dielectric on the fixed electrode is common in capacitive displacement and pressure sensors because it stops the plates shorting at full travel. The solid layer only adds a constant d2/eps2 to the effective gap, so sensitivity is still set by the air gap.

GATE 2024 · IN · Q.29NAT · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

Piezo charge amplifier, feedback 100 pF and 200 pF in series, 2 uF across sensor: Vx changes by -2 V, Vout?

Consider the readout circuit of a piezoelectric sensor shown in the figure.
When the piezoelectric sensor generates a charge , the resulting change in voltage is V. Then the corresponding change in the voltage is __________ V (rounded off to nearest integer).
Note: Assume all components are ideal.
Readout circuit of a piezoelectric sensor. The sensor, drawn as a current source to ground, feeds a node that has a 2 microfarad capacitor to ground and goes to the inverting input of an op-amp whose non-inverting input is grounded. The feedback path from the inverting input to the output V_out is a 100 pF capacitor in series with a 200 pF capacitor; the node between them is V_xPiezoelectricSensor2 μFVx100 pF200 pF−++VCC−VEEVout

Answer: Official key: -3 to -3

  1. The non-inverting input is grounded, so negative feedback holds the inverting input at virtual ground (0 V). The 2 μF capacitor across the sensor therefore has no voltage on it and takes no charge: all of flows into the feedback capacitors.
  2. The 100 pF and 200 pF capacitors are in series, so they carry the same charge . Across the 100 pF: . With V, .
  3. Across the 200 pF: , so .
  4. Check: the series feedback capacitance is and .

Trap: taking (only the 100 pF in the loop) gives V, and inverting the divider ratio gives V. Sharing with the 2 μF capacitor is the other mistake: at virtual ground it holds no charge, which is the whole point of a charge amplifier. We solved the three node equations with an op-amp open-loop gain of (standing in for an ideal op-amp): the inverting node stayed at zero to within 1 nV and came out at V.

Where this shows up in industry

This is why piezoelectric accelerometers and pressure sensors are read with charge amplifiers: the output depends only on the feedback capacitance, not on the sensor or cable capacitance, so long cables between the sensor and the conditioning unit do not change the calibration.

GATE 2024 · IN · Q.52NAT · 2 marksCapacitive, inductive, piezoelectric and Hall-effect sensors

Capacitive sensor (100 nF) in an op-amp relaxation oscillator, R = 1 kOhm, 10k/16k divider: output frequency?

Consider the capacitive sensor circuit and its output voltage shown in the figure. The circuit is switched ON at . Assuming the opamp to be ideal, the frequency of the output voltage is __________ kHz (rounded off to two decimal places).
Top: a capacitive sensor C = 100 nF from ground to the inverting input of an op-amp (node V_C), R = 1 kilohm from V_C to the output V_o, and a 10 kilohm and 16 kilohm divider from ground to V_o whose tap V_P feeds the non-inverting input. Bottom: V_o switches between +13 V and -13 V while V_C rises and falls exponentially between +V_P and -V_P; T marks one periodCapacitive SensorC = 100 nFVCR = 1 kΩ−++VCC−VEEVoVP10 kΩ16 kΩVot0Vsat = +13 VVsat = −13 V+VP−VPTVC

Answer: Official key: 6.00 to 6.30

  1. The op-amp is a Schmitt trigger: positive feedback through the 16 kΩ / 10 kΩ divider sets the threshold with , so .
  2. The sensor capacitor charges through toward the output level V. When reaches the output flips to V, and the capacitor discharges toward V until .
  3. Each half period: . Full period .
  4. .

Trap: the first half cycle after switch-on starts at and lasts only ms; do not use it. Taking (the wrong leg of the divider) gives kHz. We simulated the circuit with exact RC steps and comparator switching: the steady period was ms, matching to 0.1%.

Where this shows up in industry

Turning a capacitance into a frequency is a common way to read capacitive humidity, level and proximity sensors: a microcontroller timer measures frequency very precisely without an ADC, and the frequency shift directly gives the change in capacitance.

GATE 2024 · IN · Q.56NAT · 2 marksCapacitive, inductive, piezoelectric and Hall-effect sensors

Inductive sensors 2 mH and 4 mH driven by +/-6 sin(2000 pi t), driven-shield cable, gain 2: RMS Vout?

A shielded cable with pF and is used to connect the inductive sensors as shown in the figure. The RMS value of is __________ V (rounded off to two decimal places).
Note: Assume all components are ideal, and sensors are not magnetically coupled.
Two inductive sensors in series: L1 = 2 mH from the terminal V_s1 = 6 sin(2000 pi t) V and L2 = 4 mH from the terminal V_s2 = -6 sin(2000 pi t) V meet at a midpoint. The midpoint goes through a shielded cable (series R_wire, C_stray to the shield) whose far end feeds a +1 buffer that drives the shield, and through 2 ohm to the plus input of an op-amp with 2 ohm from the minus input to ground and 2 ohm from the output V_out back to the minus inputVs1 = 6 sin(2000πt) VL1 = 2 mHL2 = 4 mHVs2 = −6 sin(2000πt) VRwireCstrayShielded cable+1Amplifier2 Ω+−+VCC−VEEVout2 Ω2 Ω

Answer: Official key: 2.81 to 2.85

  1. Midpoint of the two inductors (no current is drawn from it, see step 2): the currents into the node sum to zero, , so .
  2. The +1 buffer drives the shield to the same voltage as the inner conductor (an active guard), so has no voltage across it and carries no current. The op-amp input draws no current either, so nothing flows through or the 2 Ω: the plus input sees .
  3. The op-amp is a non-inverting amplifier with gain , so V.
  4. RMS: .

Trap: giving the peak (4 V), or forgetting the gain of 2 (1.41 V). Putting the 2 mH and 4 mH the wrong way round only flips the sign of , not its RMS value. We solved the circuit with complex phasors including and : with the guard reaches the amplifier unchanged; even with the shield grounded the change at 1 kHz would only be 1.1 parts per million, because 20 pF is about 8 MΩ at 1 kHz.

Where this shows up in industry

Driven shields (active guards) are used on cables from high-impedance sensors, such as capacitive probes and electrochemical electrodes, so that cable capacitance does not load or shift the signal. Push-pull inductive half bridges like this one are the basis of many inductive displacement transducers.

GATE 2025 · IN · Q.13MCQ · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

Hand-held metal detector for frisking: reluctance, conductance, electric field or eddy currents?

The working of the hand-held metal detector most widely used by security personnel for human frisking is based on the principle of
  1. (A)change in reluctance of an iron core in presence of a metallic object
  2. (B)change in conductance of an iron core in presence of a metallic object
  3. (C)electric field induced by a metallic object
  4. (D)eddy current generation in a metallic object

Answer: (D) Official key: D

  1. The detector has a coil driven with an alternating (or pulsed) current. Its magnetic field induces eddy currents in any conducting object nearby.
  2. The eddy currents set up their own magnetic field, which opposes the coil's field. This changes the coil's impedance (or, in pulse detectors, makes the received pulse decay more slowly), and the electronics turn that change into an alarm.
  3. Eddy currents flow in every metal, magnetic or not, so the same detector finds a steel blade, an aluminium foil packet and a copper coin. That is option (D).

Trap: (A) sounds right because an iron object does change the reluctance of a magnetic path, but aluminium, copper, brass and gold are non-magnetic and would be missed. (B) and (C) describe effects that do not exist: an object does not change the conductance of the detector's core, and a neutral metal object does not produce an electric field. We checked each principle against a steel blade, an aluminium foil and a copper coin: only eddy-current sensing flags all three. At 10 kHz the eddy currents in aluminium flow within about 0.9 mm of the surface, so even thin foil responds.

Where this shows up in industry

Eddy-current sensing is also used in industry for non-contact proximity switches on machines, coin validation in vending machines, and eddy-current testing that finds surface cracks in aircraft skins and heat-exchanger tubes.

GATE 2025 · IN · Q.14MCQ · 1 markCapacitive, inductive, piezoelectric and Hall-effect sensors

LVDT read by a true RMS voltmeter: 0.2 V at x = +2 mm; reading at x = -3 mm?

The primary coil of a linear variable differential transformer (LVDT) is supplied with AC voltage as shown in the figure. The secondary coils are connected in series opposition and the output is measured using a true RMS voltmeter. The displacement of the core is indicated in mm on a linear scale. At the null position , the voltmeter reads 0 V. If the voltmeter reads 0.2 V for a displacement of mm, then for a displacement of mm, the voltmeter reading, in V, is
An LVDT. An AC source drives the primary coil on the left of a movable core. Two secondary coils on the right are connected in series opposition and their output goes to a true RMS voltmeter. A pointer on the core rod reads displacement x on a scale from -4 mm to +4 mm, with 0 at the null positionx (mm)+ 4+ 20− 2− 4xcoreToTrue RMSVoltmeter
  1. (A)
  2. (B)
  3. (C)
  4. (D)

Answer: (C) Official key: C

  1. In the linear range, the series-opposed output of an LVDT is an AC voltage whose amplitude is proportional to . Moving the core past null reverses the phase of the output by 180° but does not make it negative in magnitude.
  2. Sensitivity: V/mm.
  3. At mm the output amplitude corresponds to V RMS, in antiphase with the output. A true RMS voltmeter reads only magnitude, so it shows V, option (C).

Trap: answering V. An RMS value cannot be negative; the direction is in the phase, and you need a phase-sensitive demodulator to recover the sign. (B) and (D) come from subtracting or adding the two displacements. We sampled the series-opposed output over a full cycle and took its true RMS: 0.2 V at +2 mm calibrates the coil constant, and mm then reads 0.300 V.

Where this shows up in industry

This loss of direction is why industrial LVDT signal conditioners use synchronous (phase-sensitive) demodulation against the excitation, giving a DC output whose sign shows which side of null the core is on, for example in valve position feedback and dimensional gauging heads.

GATE 2025 · IN · Q.57NAT · 2 marksCapacitive, inductive, piezoelectric and Hall-effect sensors

Electrostatic actuator, plates 100 um x 100 um, d0 = 1 um, k = 0.01 N/m: charge to close the gap?

An air filled parallel plate electrostatic actuator is shown in the figure. The area of each capacitor plate is . The distance between the plates when both the capacitor charge and spring restoring force are zero as shown in Figure (a). A linear spring of constant N/m is connected to the movable plate. When charge is supplied to the capacitor using a current source, the top plate moves as shown in Figure (b). The magnitude of minimum charge () required to momentarily close the gap between the plates is __________ C (rounded off to two decimal places).
Note: Assume a full range of motion is possible for the top plate and there is no fringe capacitance. The permittivity of free space is F/m and relative permittivity of air () is 1.
Figure (a): an air-filled parallel-plate actuator. A movable top plate hangs from a fixed support on a spring of constant k, a gap d0 above a fixed bottom plate. Figure (b): with charge +Q on the top plate and -Q on the bottom plate the top plate has moved down from its original position (dashed), so the gap is smaller than d0kd0kd0+Q−QMovabletop plateFixedbottom plateMovabletop plateFixedbottom plateFigure (a)Figure (b)

Answer: Official key: 4.00 to 4.40

  1. With a fixed charge and gap , the stored energy is . The attractive force is , which does not depend on the gap.
  2. The current source feeds charge in gradually, so the plate moves quasi-statically: at each instant the spring force balances . The gap closes when : .
  3. .

Trap: writing the force as (dropping the 1/2) gives C, outside the range. Do not carry over the voltage-control result either: with a fixed voltage the plate snaps in at one third of the gap (pull-in, here at 0.18 V), but with charge control the force is constant and there is no pull-in. We swept the charge and solved the spring balance at each step: the gap first reaches zero at C.

Where this shows up in industry

Parallel-plate electrostatic actuation drives MEMS mirrors, RF switches and the self-test of capacitive accelerometers. Charge control is used in some MEMS designs because it removes the pull-in instability that limits voltage-driven plates to one third of the gap.

GATE 2026 · IN · Q.50MCQ · 2 marksCapacitive, inductive, piezoelectric and Hall-effect sensors

Parallel-plate capacitive sensor, area 2 cm^2, gap reduced from 0.5 mm by 0.1 mm: percentage change in C?

A parallel plate capacitive displacement sensor has a plate area of . The air gap between the plates is decreased by from an initial value of . The percentage change in the capacitance value is ______ %. (Assume permittivity as )
  1. (A)10.0
  2. (B)14.1
  3. (C)25.0
  4. (D)30.0

Answer: (C) Official key: C

  1. , so is inversely proportional to the gap.
  2. Before: . After (gap ): .
  3. , an increase of 25.0%: option (C). The area and cancel.

Trap: treating the change as linear in the gap, , or dividing by the new capacitance, . Neither is an option, which is the hint that the law matters here. We computed both capacitances with the given constants: the change is 25.00%.

Where this shows up in industry

Capacitive displacement probes used for shaft run-out, vibration and precision positioning work at small gaps where the 1/d law gives high sensitivity. Their electronics often measure the probe reactance, which is proportional to the gap, to get a linear output; push-pull (differential) plate arrangements are another common way to linearise it.

GATE 2026 · IN · Q.63NAT · 2 marksCapacitive, inductive, piezoelectric and Hall-effect sensors

Hall plate 0.7 mm thick, V_H = 0.9 mV, I = 6 mA, R_H = 4e-4 m^3/C: magnetic field B in tesla?

A current carrying semiconductor of thickness is placed in a transverse magnetic field. The measured Hall voltage is and the current is . If the Hall coefficient is , the value of the incident magnetic field is _______ T. (rounded off to two decimal places)

Answer: (0.2625 T) Official key: 0.25 to 0.27

  1. The Hall voltage across a plate of thickness (measured along the field) is .
  2. 0.26 T.

Trap: leaving the thickness in millimetres gives 262.5 T, a thousand times too large. The thickness in this formula is the dimension along , not the width across which is measured. We recomputed with the result and got back 0.9 mV.

Where this shows up in industry

Hall sensors in current transducers, brushless-motor commutation and gear-tooth position sensing use thin semiconductor layers with a high Hall coefficient and a constant bias current, because the Hall voltage scales with current and inversely with thickness. Integrated Hall ICs add on-chip amplification and temperature compensation of that sensitivity.

From GATE prep to a instrumentation, IoT or embedded career

Talk to a counsellor.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.