GATE Instrumentation (IN): Sensors and Industrial Instrumentation (strain gauges, RTDs, thermistors, thermocouples, LVDT, capacitive, piezoelectric and Hall sensors, pressure, flow and level measurement), previous-year questions solved, part 2
Part 2 of 3 of the Sensors and Industrial Instrumentation hub: 13 more official GATE IN questions on capacitive, inductive, piezoelectric and Hall-effect sensors, each solved step by step and checked against the official answer key. The other parts cover resistive sensors: strain gauges, RTDs, thermistors and bridges, thermocouples, pyrometers and temperature measurement, pressure, force, torque, displacement, velocity and acceleration and flow, level and process variables (pH, conductivity, viscosity).
Questions from official GATE IN papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 19 Nov 2026 · 13 of 32 questions on this page
A Hall sensor is based on which principle: photoelectric, Seebeck, piezoelectric or Lorentz force?
- (A)Photoelectric effect
- (B)Seebeck effect
- (C)Piezoelectric effect
- (D)Lorentz force
Answer: (D) Official key: D
- A current flows along a thin conducting or semiconducting strip, and a magnetic field is applied perpendicular to it.
- Each moving carrier feels the Lorentz force , which pushes it to one side of the strip. Charge builds up across the width until the transverse electric field balances the force: .
- The resulting Hall voltage is , where is the carrier density and the thickness. It needs only current and field: no light (photoelectric), no temperature difference (Seebeck) and no stress (piezoelectric).
- Answer: (D) Lorentz force.
Trap: Hall sensors are made of semiconductors, which suggests a photoelectric or other semiconductor effect. The working principle is the magnetic force on moving charge. For a strip with , mm, mA and T the force balance gives mV with no light, heat or stress applied, and zero when .
Hall sensors commutate brushless DC motors, sense gear-tooth speed in vehicles and measure current without contact in clamp meters and closed-loop current transducers. Low carrier density semiconductors are used because the Hall voltage is inversely proportional to n.
Coil reads 10 mH at 10 kHz; a pure copper sheet is brought near it: what does the LCR meter read now?
- (A)less than 10 mH
- (B)10 mH
- (C)more than 10 mH
- (D)less than 10 mH initially and then stabilizes to more than 10 mH
Answer: (A) Official key: A
- The coil's alternating field induces eddy currents in the copper sheet. By Lenz's law these currents set up a field that opposes the coil's flux.
- Treat the sheet as a shorted secondary with inductance and resistance , coupled by . The impedance seen at the coil is .
- The reflected term has a positive real part (extra loss) and a negative imaginary part, so the effective inductance is .
- Copper is non-magnetic (), so there is no extra flux path to raise the inductance. The meter reads less than 10 mH: option (A).
Trap: assuming any metal near a coil raises its inductance. That is true for a ferromagnetic object such as an iron sheet, whose high permeability concentrates the flux. A good conductor that is not magnetic only adds opposing eddy-current flux. Across the coupling and sheet values we tried, the model gave 7.500 to 9.9756 mH, always below 10 mH, with a steady value at 10 kHz.
Eddy-current proximity probes, used to monitor shaft vibration and axial position on turbines and compressors, work on this effect: a conductive target lowers the probe coil's effective inductance and raises its loss, and the driver converts that into a gap voltage. Coin validators and inductive metal detectors use the same coil-and-target interaction.
Parallel-plate C calculated as 20 pF from eps0 epsr A/d; ideal LCR meter, no cable error: likely reading?
- (A)20.5 pF
- (B)20 pF
- (C)19.5 pF
- (D)10 pF
Answer: (A) Official key: A
- assumes a perfectly uniform field confined to the overlap area. It ignores the field lines that bulge out around the edges of the plates (the fringing field).
- The fringing lines store extra energy and add extra charge on the plate edges for the same voltage, so the real capacitance is always somewhat larger than the formula value.
- With the meter and cables ideal, the reading should be a little above 20 pF: 20.5 pF, option (A). For square plates, Palmer's fringing formula gives an excess of 2.5% when the gap is about 0.48% of the plate side.
Trap: choosing 20 pF because the meter is ideal. The meter is ideal, but the formula is not: it is an approximation that always under-estimates. 19.5 pF would need the field to be weaker than uniform, and 10 pF is far off. We evaluated Palmer's correction for gap-to-side ratios from 0.001 to 0.1: the measured value exceeded the formula value in every case.
Capacitive displacement and level sensors surround the sensing electrode with a guard ring driven at the same potential, so the fringing lines end on the guard and the measured capacitance follows the ideal parallel-plate formula. Without a guard, the edge field also makes the sensor respond to objects beside the target.
LVDT secondaries 2 V RMS each at null, one off by 1 degree in phase; 1 mV/um: zero-displacement output in um?
If the differential output sensitivity of the LVDT is 1 mV (RMS)/1 m, the output for zero displacement is __________ m (rounded off to one decimal place).
Answer: Official key: 34.5 to 35.5
- The two secondaries are connected in series opposition, so the output is the phasor difference .
- At the null position both have magnitude 2 V. In an ideal LVDT they are also in phase and cancel. Here one is shifted by : , .
- .
- With 1 mV per m, this residual null voltage looks like a displacement of .
Trap: answering 0 because the magnitudes are equal. Equal magnitudes cancel only if the phases match; the voltages subtract as phasors. Taking only the in-phase part, , gives 0.61 m and misses the quadrature part that dominates. We subtracted the two phasors directly and divided by the sensitivity.
Residual null voltage, caused by phase and harmonic imbalance between the secondaries, is a specified LVDT parameter. Phase-sensitive (synchronous) demodulation in the signal conditioner rejects most of the quadrature part, which is why it is used rather than a plain rectifier near the null.
Parallel plates with air gap d1 over a solid dielectric d2 (eps2): capacitance when d1 falls by delta d1?
If is decreased by , the resultant capacitance becomes
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- The air layer and the solid layer carry the same flux density and sit one above the other, so they are two capacitors in series: with , and .
- , so .
- Only the movable plate moves, so only the air gap changes: while stays fixed. , option (A).
Trap: (D) adds (the gap increased instead of decreased), and (C) changes the solid layer, which is fixed to the bottom plate. (B) divides the air gap by , as if the two materials were swapped. We evaluated every option against the series-capacitor result for 20 random plate areas, gaps and permittivities: only (A) matched every time.
A thin solid dielectric on the fixed electrode is common in capacitive displacement and pressure sensors because it stops the plates shorting at full travel. The solid layer only adds a constant d2/eps2 to the effective gap, so sensitivity is still set by the air gap.
Piezo charge amplifier, feedback 100 pF and 200 pF in series, 2 uF across sensor: Vx changes by -2 V, Vout?
When the piezoelectric sensor generates a charge , the resulting change in voltage is V. Then the corresponding change in the voltage is __________ V (rounded off to nearest integer).
Note: Assume all components are ideal.
Answer: Official key: -3 to -3
- The non-inverting input is grounded, so negative feedback holds the inverting input at virtual ground (0 V). The 2 μF capacitor across the sensor therefore has no voltage on it and takes no charge: all of flows into the feedback capacitors.
- The 100 pF and 200 pF capacitors are in series, so they carry the same charge . Across the 100 pF: . With V, .
- Across the 200 pF: , so .
- Check: the series feedback capacitance is and .
Trap: taking (only the 100 pF in the loop) gives V, and inverting the divider ratio gives V. Sharing with the 2 μF capacitor is the other mistake: at virtual ground it holds no charge, which is the whole point of a charge amplifier. We solved the three node equations with an op-amp open-loop gain of (standing in for an ideal op-amp): the inverting node stayed at zero to within 1 nV and came out at V.
This is why piezoelectric accelerometers and pressure sensors are read with charge amplifiers: the output depends only on the feedback capacitance, not on the sensor or cable capacitance, so long cables between the sensor and the conditioning unit do not change the calibration.
Capacitive sensor (100 nF) in an op-amp relaxation oscillator, R = 1 kOhm, 10k/16k divider: output frequency?
Answer: Official key: 6.00 to 6.30
- The op-amp is a Schmitt trigger: positive feedback through the 16 kΩ / 10 kΩ divider sets the threshold with , so .
- The sensor capacitor charges through toward the output level V. When reaches the output flips to V, and the capacitor discharges toward V until .
- Each half period: . Full period .
- .
Trap: the first half cycle after switch-on starts at and lasts only ms; do not use it. Taking (the wrong leg of the divider) gives kHz. We simulated the circuit with exact RC steps and comparator switching: the steady period was ms, matching to 0.1%.
Turning a capacitance into a frequency is a common way to read capacitive humidity, level and proximity sensors: a microcontroller timer measures frequency very precisely without an ADC, and the frequency shift directly gives the change in capacitance.
Inductive sensors 2 mH and 4 mH driven by +/-6 sin(2000 pi t), driven-shield cable, gain 2: RMS Vout?
Note: Assume all components are ideal, and sensors are not magnetically coupled.
Answer: Official key: 2.81 to 2.85
- Midpoint of the two inductors (no current is drawn from it, see step 2): the currents into the node sum to zero, , so .
- The +1 buffer drives the shield to the same voltage as the inner conductor (an active guard), so has no voltage across it and carries no current. The op-amp input draws no current either, so nothing flows through or the 2 Ω: the plus input sees .
- The op-amp is a non-inverting amplifier with gain , so V.
- RMS: .
Trap: giving the peak (4 V), or forgetting the gain of 2 (1.41 V). Putting the 2 mH and 4 mH the wrong way round only flips the sign of , not its RMS value. We solved the circuit with complex phasors including and : with the guard reaches the amplifier unchanged; even with the shield grounded the change at 1 kHz would only be 1.1 parts per million, because 20 pF is about 8 MΩ at 1 kHz.
Driven shields (active guards) are used on cables from high-impedance sensors, such as capacitive probes and electrochemical electrodes, so that cable capacitance does not load or shift the signal. Push-pull inductive half bridges like this one are the basis of many inductive displacement transducers.
Hand-held metal detector for frisking: reluctance, conductance, electric field or eddy currents?
- (A)change in reluctance of an iron core in presence of a metallic object
- (B)change in conductance of an iron core in presence of a metallic object
- (C)electric field induced by a metallic object
- (D)eddy current generation in a metallic object
Answer: (D) Official key: D
- The detector has a coil driven with an alternating (or pulsed) current. Its magnetic field induces eddy currents in any conducting object nearby.
- The eddy currents set up their own magnetic field, which opposes the coil's field. This changes the coil's impedance (or, in pulse detectors, makes the received pulse decay more slowly), and the electronics turn that change into an alarm.
- Eddy currents flow in every metal, magnetic or not, so the same detector finds a steel blade, an aluminium foil packet and a copper coin. That is option (D).
Trap: (A) sounds right because an iron object does change the reluctance of a magnetic path, but aluminium, copper, brass and gold are non-magnetic and would be missed. (B) and (C) describe effects that do not exist: an object does not change the conductance of the detector's core, and a neutral metal object does not produce an electric field. We checked each principle against a steel blade, an aluminium foil and a copper coin: only eddy-current sensing flags all three. At 10 kHz the eddy currents in aluminium flow within about 0.9 mm of the surface, so even thin foil responds.
Eddy-current sensing is also used in industry for non-contact proximity switches on machines, coin validation in vending machines, and eddy-current testing that finds surface cracks in aircraft skins and heat-exchanger tubes.
LVDT read by a true RMS voltmeter: 0.2 V at x = +2 mm; reading at x = -3 mm?
- (A)
- (B)
- (C)
- (D)
Answer: (C) Official key: C
- In the linear range, the series-opposed output of an LVDT is an AC voltage whose amplitude is proportional to . Moving the core past null reverses the phase of the output by 180° but does not make it negative in magnitude.
- Sensitivity: V/mm.
- At mm the output amplitude corresponds to V RMS, in antiphase with the output. A true RMS voltmeter reads only magnitude, so it shows V, option (C).
Trap: answering V. An RMS value cannot be negative; the direction is in the phase, and you need a phase-sensitive demodulator to recover the sign. (B) and (D) come from subtracting or adding the two displacements. We sampled the series-opposed output over a full cycle and took its true RMS: 0.2 V at +2 mm calibrates the coil constant, and mm then reads 0.300 V.
This loss of direction is why industrial LVDT signal conditioners use synchronous (phase-sensitive) demodulation against the excitation, giving a DC output whose sign shows which side of null the core is on, for example in valve position feedback and dimensional gauging heads.
Electrostatic actuator, plates 100 um x 100 um, d0 = 1 um, k = 0.01 N/m: charge to close the gap?
Note: Assume a full range of motion is possible for the top plate and there is no fringe capacitance. The permittivity of free space is F/m and relative permittivity of air () is 1.
Answer: Official key: 4.00 to 4.40
- With a fixed charge and gap , the stored energy is . The attractive force is , which does not depend on the gap.
- The current source feeds charge in gradually, so the plate moves quasi-statically: at each instant the spring force balances . The gap closes when : .
- .
Trap: writing the force as (dropping the 1/2) gives C, outside the range. Do not carry over the voltage-control result either: with a fixed voltage the plate snaps in at one third of the gap (pull-in, here at 0.18 V), but with charge control the force is constant and there is no pull-in. We swept the charge and solved the spring balance at each step: the gap first reaches zero at C.
Parallel-plate electrostatic actuation drives MEMS mirrors, RF switches and the self-test of capacitive accelerometers. Charge control is used in some MEMS designs because it removes the pull-in instability that limits voltage-driven plates to one third of the gap.
Parallel-plate capacitive sensor, area 2 cm^2, gap reduced from 0.5 mm by 0.1 mm: percentage change in C?
- (A)10.0
- (B)14.1
- (C)25.0
- (D)30.0
Answer: (C) Official key: C
- , so is inversely proportional to the gap.
- Before: . After (gap ): .
- , an increase of 25.0%: option (C). The area and cancel.
Trap: treating the change as linear in the gap, , or dividing by the new capacitance, . Neither is an option, which is the hint that the law matters here. We computed both capacitances with the given constants: the change is 25.00%.
Capacitive displacement probes used for shaft run-out, vibration and precision positioning work at small gaps where the 1/d law gives high sensitivity. Their electronics often measure the probe reactance, which is proportional to the gap, to get a linear output; push-pull (differential) plate arrangements are another common way to linearise it.
Hall plate 0.7 mm thick, V_H = 0.9 mV, I = 6 mA, R_H = 4e-4 m^3/C: magnetic field B in tesla?
Answer: (0.2625 T) Official key: 0.25 to 0.27
- The Hall voltage across a plate of thickness (measured along the field) is .
- 0.26 T.
Trap: leaving the thickness in millimetres gives 262.5 T, a thousand times too large. The thickness in this formula is the dimension along , not the width across which is measured. We recomputed with the result and got back 0.9 mV.
Hall sensors in current transducers, brushless-motor commutation and gear-tooth position sensing use thin semiconductor layers with a high Hall coefficient and a constant bias current, because the Hall voltage scales with current and inversely with thickness. Integrated Hall ICs add on-chip amplification and temperature compensation of that sensitivity.