GATE Instrumentation (IN): Analog Electronics (diodes, BJT and MOSFET circuits, op-amps, instrumentation amplifiers, active filters, comparators and PLLs), previous-year questions solved, part 2
Part 2 of 2 of the Analog Electronics hub: 15 more official GATE IN questions on op-amp amplifiers, filters and precision circuits and comparators, oscillators, timers and PLLs, each solved step by step and checked against the official answer key. Part 1 covers diodes, BJT and MOSFET circuits.
Questions from official GATE IN papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 19 Nov 2026 · 15 of 29 questions on this page
Op-amp with gain 10^4, 10 Mohm input and 100 ohm output impedance as a unity-gain buffer: Zout
Answer: Official key: 9.9 to 10.0
- Negative voltage feedback pulls the output impedance down by the factor , where is the loop gain: .
- A unity-gain buffer feeds the whole output back, so and .
- (about 10 m).
- The 10 M input impedance sits across the op-amp input, in parallel with the loop it adds only siemens to the output admittance, which does not change the first four figures.
Trap: answering 100 ohm, the open-loop value, or dividing by instead of (which gives the same figure to four digits here). We wrote the node equation with a test current into the output, the input shorted to ground, the op-amp's 10 M across its input and its output resistance: .
A voltage buffer built from an op-amp can drive a cable or a converter input with almost no droop because feedback shrinks the output impedance to milliohms. The effect falls as frequency rises, since the loop gain falls, so a buffer that looks perfect at DC is weaker at high frequency.
Inverting op-amp, 10 kohm input, 100 kohm with 1 nF in feedback: frequency at which the gain is 0 dB
Answer: Official key: 15.80 to 16.00
- For an ideal inverting amplifier, gain , where is the feedback impedance. Here is in parallel with : .
- Magnitude: . At DC the gain is , and it falls with frequency (a first-order low-pass).
- 0 dB means : , so .
- , so and .
Trap: giving the corner frequency , which is where the gain has only fallen by 3 dB (to 17 dB). The gain stays 20 dB at DC and reaches 0 dB much later, at times that corner. We searched numerically for the frequency where and got .
This stage is the standard way to give a sensor amplifier a low-pass response: the capacitor across the feedback resistor limits the bandwidth and cuts high-frequency noise before the signal reaches a converter. Setting the corner so the gain falls to unity well below the converter's alias region is a common design check.
Inverting op-amp, 1 kohm and 100 kohm, 1 nA bias current and 10 uV offset: worst-case output in uV
Answer: Official key: 1110 to 1110
- A real op-amp has two small dc errors. The input offset voltage acts like a tiny battery in series with an input. The input bias current is the small current each input draws.
- Offset first. The amplifier sees at its input, and the 1 kΩ and 100 kΩ resistors amplify it by the noise gain . That holds even though the signal gain of this inverting stage is only . Offset contribution: .
- Bias current. The non-inverting input is tied straight to ground, so its bias current drops no voltage. At the inverting input the 1 nA has to come through , because the inverting node is held at a voltage close to zero and the 1 kΩ resistor cannot supply it. Bias contribution: .
- Worst case: both errors push the same way, so .
Trap: using the signal gain 100 instead of the noise gain 101 gives , which is outside the key range 1110 to 1110. We solved the circuit by nodal analysis with a very high gain op-amp, a 10 µV source at the non-inverting input and a 1 nA current drawn at the inverting input, for all four sign combinations of the two errors. The largest output magnitude is 1110 µV.
Offset and bias current set the dc floor of every precision amplifier in a sensor front end, such as a thermocouple or strain-gauge amplifier. Designers pick low-offset or chopper-stabilised parts and keep feedback resistors small, because the 100 kilo-ohm feedback resistor here costs 100 microvolts of error for every nanoamp of bias current.
Two ideal op-amps with an R chain and an R-R output divider, VS1 = 3 V and VS2 = -2 V dc: average of V0
Answer: Official key: 0.49 to 0.51
- Each op-amp has its inverting input tied to a node of the three-resistor chain, so each has negative feedback. With ideal op-amps, the two chain nodes copy the inputs: node 1 sits at and node 2 at .
- The middle resistor therefore carries . Top output: . Bottom output: .
- The two equal resistors on the right form a divider across the op-amp outputs, with nothing loading its midpoint. So . The gain of the input stage cancels in the sum.
- The sine terms average to zero over a period: the ac part is . The dc part is .
- Side check: the op-amp outputs sit at and at dc, so the supplies must be wider than 8 V for the ideal assumption to hold.
Trap: reading the circuit as an instrumentation amplifier and taking the difference of the two inputs, which gives . The output divider adds the two outputs, so it keeps the average of the inputs and rejects the difference. We solved the nodal equations with high-gain op-amps for the dc levels and again for the full sine inputs, averaging over one period: 0.50 V.
The two-op-amp input stage with a shared resistor is the front half of an instrumentation amplifier: it amplifies the difference between two sensor leads and passes the common-mode part at unity. Bridge and thermocouple amplifiers rely on it to reject the noise that appears equally on both wires.
Switched-capacitor integrator, 1 nF and 10 nF, 1 kHz switch, 1 nC initial charge: |Vo| at 20 ms
At ms, the magnitude of the voltage will be _______ mV (rounded off to the nearest integer).
Answer: Official key: 99 to 101
- A switched-capacitor integrator moves a small charge packet every clock cycle. In position 1 the 1 nF capacitor charges to . In position 2 it is connected to the virtual earth of the op-amp, and all of its charge is forced into the 10 nF feedback capacitor.
- Charge per cycle: . On the feedback capacitor this changes the output by per cycle. The sign is negative because the op-amp is inverting.
- Initial condition: , and the plate marked + is on the output side, so .
- A 1 kHz clock has a 1 ms period, so 20 ms holds 20 complete cycles, each giving one charge transfer.
- , so the magnitude is .
Trap: ignoring the initial charge gives , and adding the steps to the initial value instead of subtracting them gives . We stepped the charge on the feedback capacitor clock by clock for 20 cycles (assuming the 1 nF capacitor starts empty): .
Switched-capacitor integrators and filters let a chip set time constants by capacitor ratios instead of resistors, which are poor on silicon. They sit inside delta-sigma ADC modulators and in the programmable filters of data-acquisition chips, so the clock frequency becomes the tuning knob.
Ideal op-amp with 3R, R, R, R network, 1 V source: output voltage Vo
Answer: Official key: 1.9 to 2.1
- Look at the inverting side first. The 3R resistors to ground and to the output form a non-inverting gain stage: , where is the voltage at the non-inverting input.
- Now the non-inverting side. The input draws no current, so the current through the 3R from the 1 V source equals the current through the R to node : .
- At node three resistors meet (to , to ground and to ): , so .
- Substitute: , so .
- With : . So and (and ).
Trap: ignoring the feedback from the output into the non-inverting node and treating the 1 V as a direct input to a plain non-inverting amplifier, which would give 2 V only by accident of the loading. The resistor from to the output is positive feedback; the circuit is still stable because the negative feedback fraction (1/2) is larger than the positive one (1/3). We solved the full nodal equations with a very high gain op-amp: 2.000 V.
Circuits that mix positive and negative feedback show up as Howland current sources, which drive a sensor or a load with a fixed current whatever its resistance. Matching the resistor ratios is the whole design, and a small mismatch is what limits the output impedance in practice.
Op-amp A1 with 1 mV offset feeding inverting stage A2: output voltages for zero input
- (A)3 mV and mV
- (B)1 mV and 0 mV
- (C)1 mV and mV
- (D)2 mV and 0 mV
Answer: (A) Official key: A
- An input offset voltage is modelled as a small battery in series with one input of an otherwise ideal op-amp. Here the battery is in series with the inverting input, with its positive plate (the longer line in the figure) towards the summing node.
- With negative feedback an ideal op-amp forces its two inputs to be equal. The non-inverting input is grounded, so the pin of A1 is at 0 V and the summing node sits one battery voltage above it: .
- Three equal resistors meet at the summing node: one to , one to (feedback), and one to the inverting input of A2, which is a virtual ground at 0 V. A1's input draws no current, so the currents leaving the node add to zero: .
- (the offset is amplified by , because the second resistor also loads the node).
- A2 is an inverting stage with equal resistors, gain : . Option (A).
Trap: forgetting that the resistor to A2 also loads the summing node gives (the first value of option D). We solved the whole circuit by nodal analysis with a very high open-loop gain: , , , and only option (A) matches.
Input offset voltage is one of the first numbers checked when choosing an op-amp for a thermocouple or strain-gauge amplifier, because the offset is multiplied by the circuit's noise gain and shows up as a fixed error at the output. Precision designs use chopper or auto-zero amplifiers, or trim the offset out, so that a stage with gain 1000 does not turn a 1 mV offset into 1 V.
Inverting op-amp stage with a capacitor across the feedback resistor, dc gain -10: 3 dB cut-off
- (A)159.1 Hz
- (B)1591.5 Hz
- (C)1750.7 Hz
- (D)175.0 Hz
Answer: (A) Official key: A
- This is an inverting amplifier whose feedback impedance is in parallel with . The gain is , a first-order low-pass filter.
- At dc the capacitor is open, so the gain magnitude is . With , .
- The point is where : .
- . Option (A).
Trap: using instead of gives (option B), and scaling by the non-inverting gain 11 gives 1750.7 Hz (option C). We evaluated the gain magnitude at each option frequency and compared it with the dc gain divided by : only 159.1 Hz lands on the point.
A capacitor across the feedback resistor is the standard way to turn an amplifier stage into a low-pass filter, so the stage amplifies a slow sensor signal while cutting high-frequency noise. Thermocouple and strain-gauge front ends use exactly this to set the amplifier bandwidth just above the signal band.
Op-amp integrator (1 kilo-ohm, 2 microfarad) driven by 5 V pulses: output voltage at t = 2 ms
Answer: Official key: -2.6 to -2.4
- An inverting op-amp with a capacitor in the feedback path is an integrator. The summing node is a virtual ground, so the input current is and all of it charges the capacitor: .
- , so .
- The input is 5 V from 0 to 1 ms and 0 V from 1 to 2 ms. The integral up to 2 ms is ; the second pulse only starts at 2 ms.
- . During the zero interval the output stays flat at because the capacitor has nowhere to discharge.
Trap: treating the input as 5 V for the whole 2 ms gives -5.0 V, which forgets the gap from 1 to 2 ms. We integrated the pulse train numerically in code and got , inside the official range of to V.
Op-amp integrators sum up a signal over time: they are used in charge amplifiers for piezoelectric sensors, in the front end of dual-slope ADCs and in analogue PID controllers. Because the output holds its value when the input is zero, real designs add a reset switch or a large parallel resistor so that small offsets do not slowly drive the output into the rails.
Ideal opamp circuit with R1 to R4: ratio V/I of the source voltage to the current it supplies
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- An ideal opamp with negative feedback keeps its two inputs at the same voltage (virtual short) and draws no input current.
- No current enters the non-inverting input, so and form a plain divider across : , and the current through that chain is .
- The virtual short gives . The voltage across is , so carries .
- The source current is the sum of the two branches: .
- Hence . Option (A). drops out because it only sets the output voltage, not the current drawn from the source.
Trap: adding only the branch, or assuming the source sees in series. We solved the circuit by nodal analysis for three sets of resistor values (for example gives ) and tested every option: only (A) matched all three.
Knowing the input resistance an opamp stage presents is what decides whether it loads a sensor or a bridge. A source that must drive several stages, such as a transducer feeding a signal-conditioning chain, is checked this way before the circuit is built.
Which ideal-opamp circuits perform a non-linear operation: in-amp, Schmitt trigger, log amp, rectifier?
- (A)Instrumentation amplifier
- (B)Schmitt trigger
- (C)Logarithmic amplifier
- (D)Precision rectifier
Answer: (B) and (C) and (D) Official key: B;C;D
- A circuit is linear when it obeys superposition: the output for a sum of inputs equals the sum of the outputs, and doubling the input doubles the output. Anything with a threshold, a diode or an exponential breaks this.
- Instrumentation amplifier: resistor network only around opamps, . A straight-line gain, so it is linear: (A) is not a correct choice.
- Schmitt trigger: positive feedback gives an output that jumps between two levels, , at two thresholds. Output depends on the input crossing a threshold, not on its size: non-linear (B).
- Logarithmic amplifier: a diode or BJT in the feedback path gives . A logarithm is not a straight line: non-linear (C).
- Precision rectifier: diodes inside the feedback loop pass only one polarity, for a half-wave type. Output is zero for half the input range: non-linear (D).
- Answer: (B), (C) and (D).
Trap: calling the instrumentation amplifier non-linear because it has three opamps. Its gain is a fixed number. We modelled each circuit and tested additivity and homogeneity numerically with inputs of 1.5 V and 3 V: only the in-amp passed both tests.
Instrumentation amplifiers are used for strain gauges and thermocouples because they stay linear and reject common-mode noise. Log amplifiers compress a huge range, such as photodiode currents over six decades, and precision rectifiers convert AC sensor signals to a DC level.
Two op-amp instrumentation amplifier with R 1 kilohm, Rf 10 kilohm, Vin 100 mV and +/-15 V supplies: Vout
- (A)−15
- (B)15
- (C)2.1
- (D)1.1
Answer: (C) Official key: C
- Each op-amp is a non-inverting amplifier whose inverting input sits at the same voltage as its non-inverting input (virtual short). So the two ends of are at the two input voltages, and the current through is .
- That same current must flow through both feedback resistors. The top output rises by and the bottom output falls by .
- . Option (C).
- Check the rails: the two outputs are +1.05 V and -1.05 V, far inside , so neither op-amp saturates. A common-mode input added to both inputs changes neither output difference, which is why this circuit is used as an instrumentation amplifier.
Trap: treating it as a single non-inverting stage, , gives 1.1 V (option D). The two resistors both carry the same current, so the gain has . We solved the ideal op-amp equations and tested each option; only 2.1 V matches, and the saturation values of 15 V and V are not reached.
Two op-amp instrumentation amplifiers amplify the small differential signal from bridge sensors such as strain gauges and thermocouple amplifiers while rejecting noise that appears equally on both leads. One resistor sets the gain, so gain can be changed without upsetting the common-mode rejection.
Three op-amp active filter loop, R 1 kilohm, C 1 microfarad, Vin 1 V at 1000 rad/s: amplitude of Vout
- (A)0.5
- (B)0.707
- (C)1.0
- (D)1.414
Answer: (C) Official key: C
- Treat every inverting input as a virtual ground and write the current balance at each. Let . Stage 1 sums and through and has feedback , so .
- Stage 2 is an inverting integrator: . Stage 3 is a unity inverter: .
- Combine: , so , which gives . This is a second-order low-pass filter with and a quality factor .
- Here , so is exactly and . Then and . Amplitude . Option (C).
Trap: assuming the output is of the input at the corner frequency (a Butterworth habit, ) gives option (B); this filter has , so at the gain equals instead of . We solved the three nodal equations in complex numbers at 1000 rad/s and tested each option: only 1.0 V passes.
Multi-op-amp state-variable and biquad filters are used as anti-alias and signal-conditioning filters in data acquisition, because the centre frequency and the quality factor can be tuned by separate resistors. Knowing that gain at the natural frequency equals Q tells you how much peaking a design will have.
RC node into a comparator with a 2 V reference, switch opened at t = 0: time at which Vout goes LOW
Answer: Official key: 0.365 to 0.369
- The comparator output is HIGH () while the non-inverting input is above the inverting input, and LOW () when it falls below.
- Inverting input, the reference: the and divider gives .
- Before (switch closed) the capacitor voltage is the divider of and : , above 2 V, so the output is HIGH.
- After the switch opens the capacitor discharges through the only: with .
- The output goes LOW when : .
Trap: using the time constant, which would be right only while the switch is closed, gives 0.061 ms. Once the switch opens, the 1 kilohm resistor is out of the circuit. We stepped the capacitor voltage down until it crossed 2 V: 0.3670 ms.
A comparator with an RC input is a simple timer and a loss-of-signal detector: the capacitor sets how long the output stays high after the input is removed, and the reference sets the trip point. Watchdog and power-fail circuits in instruments use exactly this arrangement.
PLL with divide-by-20 on the input and divide-by-1024 in the feedback, 10 kHz in: output frequency
Answer: Official key: 512 to 512
- A phase-locked loop adjusts its VCO until the two signals reaching the phase detector have the same frequency (and a fixed phase difference). In steady state the loop is locked.
- One detector input is the 10 kHz input divided by 20: .
- The other detector input is the VCO output divided by 1024: .
- Lock requires , so .
This is a frequency synthesiser: the feedback divider multiplies the reference, and the input divider sets the step size. The loop is also a controller, so we simulated it as a type-2 loop (proportional plus integral filter) from a VCO that free-runs at 300 kHz: the output settled to 512.0 kHz. Trap: dividing by 20 and multiplying by 1024 is easy to invert; is about 0.2 kHz, far below a sensible VCO range.
Phase-locked loops with a divider in the feedback path are how a crystal reference is turned into the many clock frequencies used by microcontrollers, ADC sampling clocks and radio local oscillators. The same loop is used in lock-in style instruments to track a signal whose frequency drifts.