Recorded workshop · CIVIL

Structural Optimisation of Steel Structures by Pre Engineering

Held 24 Mar 20212 videos

Notes written by Skill-Lync from the recording · Updated 17 Nov 2026

What this workshop covers

This workshop on structural optimisation of steel structures by pre-engineering shows why tapered PEB frames weigh far less than conventional frames. Recorded by Skill-Lync in March 2021, part 1 covers the basics: why steel suits large spans, the parts of an industrial steel building, hot-rolled versus cold-formed sections, steel properties from IS 800:2007, the design codes (IS 800, IS 808, IS 811, MBMA, AISC 360, Eurocode 3), common software, and what goes into the cost of a steel structure.

Part 2 explains the pre-engineered concept, shaping each member to its bending moment diagram, then runs a case study on a 48.8 m span warehouse frame in STAAD.Pro. A conventional ISMB 500 frame is compared with a tapered built-up PEB frame under dead, live and wind loads, and the instructor reports a 43% weight saving per frame.

It suits civil graduates and early-career structural engineers who know basic steel design. The case study is a single 2D frame; wind load calculation, connection design and bracing design are not covered, and the market and steel-price figures are the instructor's from 2021.

Chapters

Part 1

  1. 0:00 Agenda: steel structures, codes, PEB vs conventional
  2. 1:18 Why steel for large spans: strength and ductility
  3. 4:37 Market trends for steel buildings in India
  4. 6:03 Industrial building parts: rafters, purlins, girts
  5. 11:09 Mechanical properties of steel per IS 800:2007
  6. 11:50 Hot-rolled vs cold-formed steel sections
  7. 14:52 Codes: IS 800, IS 808, IS 811, MBMA, AISC, EN 1993
  8. 16:11 Software: STAAD.Pro, Robot, ETABS, SAP2000, Tekla
  9. 17:05 What optimisation means: the costs of steel

Part 2

  1. 0:00 PEB concept: tapered members and variable plates
  2. 1:33 Matching section depth to the bending moment
  3. 3:34 Case study: 48.8 m x 75 m warehouse brief
  4. 5:13 STAAD.Pro frame model, dead and live loads
  5. 6:40 Wind load cases with internal pressure
  6. 8:44 Conventional ISMB 500 frame and its utilisation
  7. 10:16 PEB frame: 5 mm webs and tapered depths
  8. 13:29 Weight comparison: 6.73 t vs 3.82 t per frame
  9. 15:05 Job prospects and construction speed

Key points from the session

  • A conventional frame uses one hot-rolled section, sized for the peak moment, along its whole length. A PEB frame tapers columns and rafters and varies web and flange plates so the section follows the bending moment diagram, for example shallow at a pinned column base and deep at the knee. The instructor says PEBs are generally up to 30% lighter.
  • Hot-rolled sections such as ISMB, ISMC and ISHB are cheaper and used for main columns and beams; cold-formed sections, typically 2-4 mm thick with tighter tolerances, are used for secondary members like purlins and girts that carry light roof and wall sheeting.
  • Steel properties used in design per IS 800:2007: density 7850 kg/m3, modulus of elasticity 200,000 N/mm2, Poisson's ratio 0.3, and yield strength 250 N/mm2 for E250 mild steel or 350 N/mm2 for high-strength steel.
  • Bracing is needed along the length of a steel shed because frames give rigidity only across the width. X, inverted-V or K bracing using rods, pipes or angles is chosen by whether the member takes tension only or tension and compression.
  • Case study: warehouse 48.8 m x 75 m, 9 m clear eave height, 7.5 m bay spacing, Coimbatore, 7.4 degree roof slope, roof live load 57 kg/m2 (maintenance access only) and wind per IS 875 Part 3:2015. The instructor notes that wind, not seismic, usually governs light steel sheds because seismic force depends on mass.
  • The ISMB 500 conventional frame had utilisation as low as about 0.5 mid-rafter and 0.935 near the ridge. The PEB frame used 5 mm webs (the web mainly carries shear), 200 x 8 mm flanges and depths tapering between about 350 and 800 mm, reaching ratios of 0.7-0.9 after more than ten iterations.
  • Result reported: 6.73 t per conventional frame versus 3.82 t for the PEB frame, about 43% lighter. At the instructor's 2021 rate of 100-120 rupees per kg erected, that is roughly 1 lakh rupees saved per frame, or about 15 lakh for a 100 m long building with 13-15 frames.

What is the difference between a pre-engineered building and a conventional steel building?

A conventional steel building uses standard hot-rolled sections with constant depth, sized for the maximum bending moment. A pre-engineered building uses built-up, tapered members whose depth and plate thickness follow the bending moment diagram, so less steel is wasted where moments are low. The trade-off is more skilled fabrication labour per tonne.

How much steel does a PEB frame save compared to an ISMB frame?

In this session's case study of a 48.8 m span warehouse frame, the conventional ISMB 500 frame weighed 6.73 tonnes and the optimised PEB frame 3.82 tonnes, about 43% lighter. The instructor says PEBs are generally up to 30% lighter, and the saving depends on span, loads and how far the profile is iterated.

Why does wind load govern the design of steel industrial sheds?

Seismic force is an inertia force, so it scales with the mass of the building, and a steel shed with sheet cladding is very light. Wind pressure, by contrast, acts on the large wall and roof areas regardless of weight and can create uplift and instability, so the instructor says it is usually the critical load.

Where to go next

Who should watch

For Civil Engineers

A 24 Mar 2021 workshop recording from Skill-Lync on CIVIL. For a structured course with projects on this topic, see Skill-Lync's civil engineering courses.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.