GATE Electronics (EC): Networks (nodal and mesh analysis, Thevenin and Norton, AC phasors and power, resonance, RL, RC and RLC transients, Laplace, two-port parameters), previous-year questions solved, part 2
Part 2 of 4 of the Networks: Theorems, AC, Transients hub: 7 more official GATE EC questions on AC steady state: phasors, impedance, power and resonance, each solved step by step and checked against the official answer key. Part 1 covers DC circuit analysis: nodal, mesh, superposition, Thevenin and Norton, transients and Laplace analysis of RL, RC and RLC circuits and two-port networks.
Questions from official GATE EC papers (IIT Kharagpur 2022, IIT Kanpur 2023, IISc Bengaluru 2024, IIT Roorkee 2025, IIT Guwahati 2026); solutions by Skill-Lync. · Updated 17 Nov 2026 · 7 of 24 questions on this page
Locus of Z(jw) for R1 in series with R2 parallel C, semicircle from 5 kOhm to 2 kOhm: R1 and R2?
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- The impedance seen from the terminals is .
- At the capacitor is an open circuit, so . On the plot this is the right-hand end of the arc, . So .
- As the capacitor is a short circuit and it shorts out , so . That is the left-hand end, . So and .
- Check with the shape. The term traces a semicircle of diameter in the lower half plane (its imaginary part is negative, so the plot shows ). Its height is , which is exactly the marked on the vertical axis.
- So , : option (A).
Trap: reading the right end, , as one resistor alone. Option (D) takes and options (B), (C) take . But the right end is the sum. With option (D) the arc would run from to and rise to , and with option (B) it would run from to . The code swept for all four pairs and compared the end points and the peak with the plot: only (A) matches (, and ). It also confirmed that every point of the (A) locus lies at distance from on the real axis.
Impedance plots like this are how engineers read a measured component: a resistor in series with a parallel R and C is the standard model of a battery cell, a sensor or an electrode in impedance spectroscopy, and the two ends of the arc give the series and total resistance.
V(t) = sin t, 1 Ohm in series with Z, steady current peak 1/sqrt2 A, zero rising at t = pi/4: what is Z?
- (A)a capacitor of
- (B)an inductor of
- (C)a capacitor of
- (D)an inductor of
Answer: (B) Official key: B
- The source is , so . Use as the phase reference: .
- From the graph the current has amplitude and crosses zero going upward at . A sine that rises through zero at is . The current lags the voltage by .
- A lagging current means the load is inductive. In phasor form , so . Hence .
- For an inductor at , so : option (B). The magnitude is also right, , giving .
Trap: option (A), a capacitor, has the same impedance size, , so the amplitude is also . But the current then leads by : , which is at its peak, not at zero, when . Options (C) and (D) fail on the amplitude: gives 0.866 A and gives 0.500 A, not A. The code solved the phasor circuit for all four and also integrated the series circuit in time with a fourth-order Runge-Kutta method: for (B) the steady current at is -2.6e-05 A and rising, for (A) it is 0.707 A, the peak.
Telling an inductive load from a capacitive one by whether the current lags or leads the voltage is the everyday way to read a scope trace of a motor winding, a filter inductor or a decoupling capacitor, and it sets the sign of the reactive power a power-factor correction stage must cancel.
Series RLC with Q = 1000 at a centre frequency of 10^6 rad/s: which R, L and C are possible?
- (A) and
- (B) and
- (C) and
- (D) and
Answer: (D) Official key: D
- Every option has the same and . The centre (resonant) frequency of a series circuit is . So all four options already give the stated centre frequency, and alone decides .
- For a series circuit, . Put in the numbers: , so with in ohms.
- For we need : option (D).
Trap: the four options give for , so picking an option with a larger gives a much lower (for example (C) gives , a ten times wider band). The code swept the series impedance over frequency for each option and measured as the centre frequency over the half-power bandwidth: 25, 25, 100 and 1000, and the peak was at in all four.
Q of a series LC branch sets how sharp a tuned circuit is, from RF matching networks to wireless-charging coils. In a real coil the resistance is the winding loss, so a Q of 1000 means an ohmic loss of one thousandth of the reactance.
Parallel C, L, R with admittances j0.25, -j0.1 and 0.2 S across a 1 volt at 90 degrees source: branch currents?
Which one of the following is TRUE?
- (A)
- (B)
- (C)
- (D)
Answer: (A) Official key: A
- The three branches are in parallel, so each has the full source voltage across it. With the current arrows pointing down, each current is the branch admittance times : .
- Capacitor: .
- Inductor: .
- Resistor: .
- These three together are option (A). Check on the phases: the resistor current is in phase with the voltage (), the capacitor current leads it by and the inductor current lags it by .
Trap: reading the given numbers as impedances, so that . That gives , and A, the magnitudes in (B) and (D), because , and . The problem states admittances in siemens, and current is admittance times voltage, so the magnitudes must be , and . The code computed with complex numbers and matched only (A). It then simulated the steady state at in the time domain, with , and (which have exactly these admittances), using , and , and fitted the phasors by projection. They agreed with (A) within . Reading the values as impedances gives , and , which is none of the four options.
Admittance is the natural unit for parallel branches because they simply add, which is how a decoupling network of capacitors in parallel with a regulator output is analysed at each frequency. The phase relations used here (capacitor current leads, inductor current lags) decide whether a parallel RLC load looks capacitive or inductive to the source.
Voltmeter reads 25 V rms and ammeter 5 A rms across 5 ohm, C and 1 H in series at 200 rad/s: find C
What should be the value of the variable capacitor such that the RMS readings on and are and , respectively?
- (A)
- (B)
- (C)
- (D)Insufficient information to find
Answer: (A) Official key: A
- The voltmeter is across the output terminals of the box, which are also the terminals of the series branch. The ammeter carries the branch current. So the two readings are the RMS voltage and RMS current of the same branch, and their ratio is the magnitude of the branch impedance: .
- At the branch impedance is , with .
- forces . The branch is at series resonance and looks purely resistive.
- means , so , option (A).
- The box and the source do not matter. Whatever the box is, the ratio of the two readings is the branch impedance alone, so the information is sufficient.
Trap 1: option (D). It is tempting because the box is unknown, but the meters sit on the branch, not on the box input. Trap 2: using the source RMS value in place of the voltmeter reading. That gives , and or , neither of which is an option. The code scanned over capacitor values from to and found the single value (the other options give of about and ), and drew random Thevenin sources and impedances for the box to confirm the voltmeter to ammeter ratio always equals . The wrong-source readings were computed and checked to match no option.
Series resonance of a capacitor with a parasitic inductance is why a decoupling capacitor stops helping above its self-resonant frequency: at resonance only its small series resistance is left, and above it the part behaves as an inductor. The same voltmeter-and-ammeter ratio is how impedance is read in practice on a bench.
1 uF and 2.2 mH in parallel with a 1 kOhm load, source 12 sin(wt): average load power at resonance, in mW?
The average power (in mW) dissipated in the load resistance of at the resonant frequency is __. (rounded off to two decimal places)
Answer: Official key: 71.50 to 72.50
- The source is ideal, so the voltage across all three parallel branches is the source voltage itself, with peak value . The capacitor and inductor cannot change this voltage.
- Resonance is where the parallel and susceptances cancel: . The two branches together take no current from the source, and only the resistor draws current.
- The is a peak value, so the average power in the resistor is .
- Because the source is ideal, the load power is at every frequency, not only at resonance. Resonance matters for the current the source must supply, which is smallest there.
Trap: using as if it were an rms value gives , twice the right answer and outside the official range 71.50 to 72.50. The code checked that is smallest at 21320 rad/s, that the and admittances cancel there, and averaged over one period in time: 72.00 mW at resonance and 72.00 mW at .
A parallel LC tank across a source is the basic tuned circuit in RF oscillators and matching networks. A real source has an output resistance, and then the tank voltage, and so the load power, does peak at resonance, which is what makes it a band-pass selector.
R_C-C and R_L-L branches in parallel, L = 1 uH, C = 1 uF, theta1 + theta2 = 90 deg at 159.15 kHz: R_C x R_L?
Among the following options, what is the nearest integer value of ?
- (A)
- (B)
- (C)
- (D)
Answer: (B) Official key: B
- Take the voltage as the reference. Capacitor branch: leads by with . Inductor branch: lags by with .
- At , . So and (the code gives 1.0000 and 1.0000).
- means , that is . So and .
- . The frequency cancels out. So : option (B).
Trap: adding the reactances instead of multiplying them gives , option (C). Option (A) would need both angles to be (ideal reactive branches), but then : the code gives 180 degrees for . The code computed both phasor currents with complex arithmetic and scanned resistor pairs with product (the closest non-zero value to option A's ), , and for five values of : the angle sum is only for the product . A bisection on gave the product 1.000000, and the same product at and (1.000000, 1.000000).
Every real capacitor has an equivalent series resistance and every real inductor a winding resistance, so a decoupling capacitor in parallel with an inductive path is exactly this pair of branches. With both resistances equal to the pair is a purely resistive impedance at all frequencies, the constant-resistance idea used in Zobel and equaliser networks.