Identification of Cracks What is the mode of failure or damage of the beams in the figure? Would you characterize the case as damage or as a failure? Are the damages repairable? Elaborate. a) The above figure represents the Flexural cracks developed at the bottom flange of the beam. This failure initiates by cracking…
Praveen Ps
updated on 16 Jul 2022
Identification of Cracks
What is the mode of failure or damage of the beams in the figure? Would you characterize the case as damage or as a failure? Are the damages repairable? Elaborate.
a)
The above figure represents the Flexural cracks developed at the bottom flange of the beam. This failure initiates by cracking and spalling of concrete and subsequent yielding of steel reinforcement and can also be formed as result of plastic hinge formation at undesirable location.
This usually developes at the bottom flange as the top flange is suffiently supported by the slab.
b)
This type of failure is termed as Pull out failure. This failure is developed in beams due to inadequate rebar development from beam to column (inadequate rebar bond). So, in this case the beam will be strong enough to withstand the load but at the beam column connection due to inadequate rebar development length, the joints will be weak and cracks will be developed as a vertical line along the beam column junction.
These type of failures are non-repairable.
c)
This figure represents Beam-Column connection failure. It occurs due to the formation of plastic hinge at undesirable locations. These beam column juctions are the weakest links as it fails in shear under lateral seismic loads resulting in unrepairable damage to the buildings. Shear failure governs in beam column connection failure. The shear cracks thus developed, if left unattended can lead to collapse of the building and can cause severe damage to the structure.
The plastic hinge formation at the beam column interface is undesirable which leads to shear cracks, instead the plastic hinge should be formed some distance away from the junction.
This failure can also occur due to inappropriate detailing.
2)
a)
The failure shown in this figure is the Compression failure. This figure shows the concrete crushing.
Compression failure is caused due to excess axial stress. Due to this concrete and steel will reach the yield stress. As a result the concrete crushes and the steel buckles.
This type of failure is non-repairable.
b)
This figure depicts the Confinement failure of column.
This failure is mainly caused due to inappropriate detailing of plastic hinge location. Shear force increases during an earthquake especially at columns and beam-column joints.Seismic design requires increasing of ductility of structures for performance-based design approach. In particular, columns of buildings can be having sufficient transverse reinforcement in the plastic hinge region. Therefore, structural elements which have such details show low performance against dynamic loading and loose their shear and axial load carrying capacity.
These failure are also irrepairable.
c)
The failure depicted in this figure is the Short column failure or Influence of partial height infill increasing column shear force.
This type of failure can be caused due to structural adjustments or due to continous openings at the top of infill walls between columns. Lateral forces that occured by an earthquake are carried by column and shear walls. Length of columns is an important factor for dissipation of these loads. When the length of column decreases, the column becomes stiffer and brittle than other columns and this columns attracts more shear forces. Thus shear failure which is the critical type of concrete column damage occurs at these columns.
This failure is also non-repairable.
Leave a comment
Thanks for choosing to leave a comment. Please keep in mind that all the comments are moderated as per our comment policy, and your email will not be published for privacy reasons. Please leave a personal & meaningful conversation.
Other comments...
Project 1
PROJECT ANALYSIS AND DESIGN OF A G+6 RESIDENTIAL BUILDING IN BANGALORE INTRODUCTION: With the advancements in software technology, the analysis and design of buildings have become…
08 Sep 2022 05:58 PM IST
Week 3 Challenge
1. 1. State the primary load cases to be considered for design. 2. What is One – Way slab? 3. What is the value of unit weight of structural steel and soil? 4. Name few sections that can be defined using Properties tab in STAAD Pro. 5. Define Primary Beams. 2. 1.…
28 Aug 2022 06:11 PM IST
Week 2 Challenge
1. 1. How will you assign Circular section to column? 2. How will you assign Unit system to a .std model file? 3. What are the parameters to be specified while using “Bay Frame” option? 4. Name few codal standards incorporated in STAAD Pro software. 5. How…
28 Aug 2022 06:05 PM IST
Week 1 Challenge
1. 1. Write the steps involved to upload a .std file through web mail? 2. Name the different materials that can be designed using STAAD Pro. 3. Is it possible to capture images in STAAD Pro? If yes how? 4. Name the three ways by which you can create a model. 5. Write…
28 Aug 2022 06:00 PM IST
Related Courses
0 Hours of Content
Skill-Lync offers industry relevant advanced engineering courses for engineering students by partnering with industry experts.
© 2025 Skill-Lync Inc. All Rights Reserved.