Wiring harness design in CATIA V5 - 3D modeling Week 4 Challenge
Routeing of harness as per given layout in electrical workbench
Routeing of harness as per given layout in electrical workbench of following connector
- DT06-4S
- DT06-6S
- DT06-2S
- DT06-08SA
Given layout

First, we download all the connector from TE.com are DT06-4S, DT06-6S, DT06-2S, DT06-08SA
Then we need to define all connector electrically
DT06-2S
Defining bundle entry point as we need to route this assembly, we also define connector connection point but here we had no need of connector connection point so we hide it. DT06-2S has two terminals

DT06-4S
Defining bundle entry point as we need to route this assembly, we also define connector connection point but here we had no need of connector connection point so we hide it. DT06-4S has 4 terminals

DT06-6S
Defining bundle entry point as we need to route this assembly, we also define connector connection point but here we had no need of connector connection point so we hide it. DT06-6S has 6 terminals

DT06-08SA
Defining bundle entry point as we need to route this assembly, we also define connector connection point but here we had no need of connector connection point so we hide it. DT06-8SA has 8 terminals

Geometrical bundle
When we set all connector at their places and its time to routeing first we need to define all connector as geometrical bundle otherwise routing will not work

Multi-branchable documents
To make connection between two connector we use this command

Add branch point
To make sub connection for another connector we use this command

Protective Covering
To Protect wires from cut by mechanical part we need to cover wire by corrugated tubes or cotton tape
We use corrugated tubes

Final bundle routing for the connectors