Rolling force calculator: roll force, maximum draft, torque and power
Roll force in flat rolling is F = Ȳf·w·L: the average flow stress times the strip width times the contact length √(R·d). Groover's textbook strip (300 mm wide, 25 to 22 mm, 250 mm rolls, K 275 MPa, n 0.15) needs 1443 kN, 19.76 kN·m per roll and 206.9 kW at 50 rpm. Type your strip, rolls and friction to get the draft against μ²R, the bite angle, the force with and without friction, torque and power. Free, runs in your browser.
The second tab draws the slab-method friction hill with the neutral point and forward slip. The third plans the passes from a thick strip to a target. The fourth checks the copper rolling challenge from Skill-Lync's Ansys Workbench course, built after reading all 172 public reports of it.
Groover's example as printed in University of Basrah and Mustansiriyah notes · NPTEL cold rolling (slab method) · Wikipedia "Rolling" and "Strain hardening exponent" · Ansys Copper Alloy data · checked against a separate solution and the Manufacturing Processes book (1,370 checks at build) · Updated 23 Nov 2026
Cold rolling, no front or back tension. Kalpakjian's K and n are for annealed metal (Wikipedia's table); pick "Custom" to type your own. The no-friction force is Groover's; the friction form is NPTEL's, with the plane-strain flow stress. Typical μ: 0.1 cold, 0.2 warm, 0.4 hot.
Slab method (von Kármán), integrated exactly along the arc rather than with the small-angle shortcut, so it works for any bite angle. It needs the rolls to bite (draft at most μ²R). The material inputs above are shared with the first tab.
Each pass is checked against μ²R. Strain is counted from the annealed entry thickness, so every pass sees the flow stress the earlier passes hardened the strip to (no annealing between passes, no spread).
Defaults: the Week 4 geometry as reports state it (25 mm radius rollers, 10 mm thick copper, a 6 mm gap in one report, 4 mm in two), 195° over 14 steps, and the median stress and plastic strain of the public reports. Copper Alloy NL: E 110 GPa, yield 280 MPa, tangent 1,150 MPa as the reports quote them.
| Quantity | Equation | Value | Also |
|---|---|---|---|
| Draft d | 3 mm | reduction 12% | |
| Maximum draft | 3.6 mm | bites | |
| Bite angle α | 6.28° | needs μ ≥ 0.11 | |
| Contact length L | 27.39 mm | min. R for this draft 208.3 mm | |
| True strain ε | 0.1278 | ||
| Average flow stress Ȳf | 175.6 MPa | exit 202 MPa | |
| Roll force (no friction) | 1443 kN | 147.2 tf | |
| Roll force (friction, plane strain) | 1783 kN | Ȳ' 202.8 MPa, h_av 23.5 mm | |
| Torque per roll | 19.76 kN·m | 24.41 kN·m with friction | |
| Power, both rolls | 206.9 kW | 255.6 kW with friction |
- Draft 3 mm is within μ²R = 3.6 mm: the rolls bite (exact check: μ 0.12 ≥ tan α 0.11).
| Quantity | Value |
|---|---|
| – | – |
| Pass | h in → out | Draft | Ȳf | Force | Power |
|---|---|---|---|---|---|
| – | |||||
- 195° of a 25 mm radius roller moves its surface R·θ = 85.08 mm; you pushed the workpiece 90 mm. The strip moves 5.777% faster than the roll surface, so the contact must slip. 90 mm needs 206.3° (14.73° per step over 14 steps).
- Draft 4 mm is more than μ²R = 1 mm at μ = 0.2: rolls this size could not pull the strip in by friction (the bite angle 23.07° needs μ ≥ tan α = 0.426). That is why the model pushes the workpiece: the push, not friction, feeds it.
- Thickness strain ln(h0/hf) = 0.5108; with no spread (plane strain) the equivalent plastic strain is (2/√3)·ln(h0/hf) = 0.5899 through the thickness. Corners and contact edges run higher.
- Your maximum plastic strain 1.546 is 2.621 times the through-thickness 0.5899: a local peak at a corner or contact edge, not the strain of the rolled section.
- On the bilinear line (yield 280 MPa, tangent 1150 MPa, so 1162 MPa per unit plastic strain) a plastic strain of 1.546 means 2077 MPa in the copper.
- Your maximum equivalent stress is 3107 MPa, 7.225 times the 430 MPa tensile strength. Above the 2077 MPa the copper's line allows: a whole-set-up maximum can sit in the steel rollers, which are linear elastic with no limit, or in one distorted element at a contact edge. Plot the copper alone to compare.
What is the roll force formula?
For flat rolling, the roll force is the flow stress times the contact area w × L. The geometry first:
The strip work-hardens through the gap, so Groover uses the average flow stress from zero to the pass strain, and with no friction:
Friction raises the pressure towards the neutral point, and the strip deforms in plane strain (it cannot get much wider), which adds 15% by von Mises. NPTEL's cold-rolling notes combine both:
The University of Basrah notes print the same bracket on Ȳf alone, and the Mustansiriyah lecture suggests adding about 20% for friction. Groover's example, as both sets of notes print it, against the calculator:
| Quantity | Printed | Calculator |
|---|---|---|
| Draft, maximum draft | 3 mm, 3.6 mm | 3 mm, 3.6 mm |
| Contact length L | 27.4 mm | 27.39 mm |
| True strain, Ȳf | 0.128, 175.7 MPa | 0.1278, 175.6 MPa |
| Roll force | 1,444.254 kN | 1443 kN |
| Torque per roll | 19.8 kN·m | 19.76 kN·m |
| Power, both rolls | 207.1 kW (278 hp) | 206.9 kW (277.5 hp) |
The printed numbers use L and Ȳf rounded to one decimal. The friction-corrected force for this strip is 1783 kN, 23.54% more. NPTEL's own example (low-carbon steel, 250 mm wide, 12 to 9 mm, R 250 mm, μ 0.12, K 550 MPa, n 0.26) prints 2.9 MN; the verifier reproduces it.
What is the maximum draft in rolling, and why μ²R?
The rolls pull the strip in only by friction. At first contact the roll pressure leans back against the strip at the bite angle α, and friction μp must beat its horizontal part. That needs μ ≥ tan α, and for small angles it becomes the textbook limit:
Wikipedia states it as the case "when the frictional force on the metal from inlet contact matches the negative force from the exit contact". Turn it round and you get the smallest roll radius, d/μ², or the friction needed, √(d/R). Maximum draft per pass, in mm:
| Roll radius | μ = 0.05 | μ = 0.1 | μ = 0.2 | μ = 0.4 |
|---|---|---|---|---|
| 25 mm | 0.0625 | 0.25 | 1 | 4 |
| 100 mm | 0.25 | 1 | 4 | 16 |
| 250 mm | 0.625 | 2.5 | 10 | 40 |
| 500 mm | 1.25 | 5 | 20 | 80 |
Typical friction from the Basrah and Mustansiriyah notes: about 0.1 cold, 0.2 warm, 0.4 hot; up to 0.7 when the strip sticks. That is why hot rolling takes far bigger drafts than cold.
How do you calculate rolling torque and power?
Groover assumes the force acts at the middle of the arc of contact, a lever arm of 0.5L:
with F in newtons, L in metres and N in rpm. The Basrah notes add that 0.5L is a good estimate for hot rolling and 0.4L better for cold rolling, so the torque and power here are on the high side for a cold pass by up to a fifth. The power is for the two rolls together; one roll takes half.
What is the neutral point, and what is forward slip?
The strip gets thinner and so faster through the gap (h0v0 = hf vf), while the roll surface turns at one speed. At one point on the arc they match: the neutral, or no-slip, point. Before it the roll is faster and friction drags the strip in; after it the strip is faster and friction holds it back. Both push the pressure up towards the neutral point, which is why the pressure curve is called the friction hill. The slab (von Kármán) equations for the two zones, with q the horizontal compressive stress:
The calculator integrates both branches along the exact arc: from the entry (q equal to minus the back tension) and from the exit (minus the front tension). The pressure is the lower branch and the neutral point is where they meet. NPTEL's small-angle (Bland and Ford) solution gives the neutral point in closed form:
For Groover's strip at μ = 0.12 the exact integration puts the neutral point 1.7° from the exit, and the closed form 1.67°. The peak pressure is 1.094 times S. The slab force is 1724 kN, against 1443 kN with no friction and plane strain ignored. The strip leaves faster than the roll surface by the forward slip:
Here 0.9564%: with the rolls at 1.309 m/s the strip leaves at 1.322 m/s and enters at 1.163 m/s. Raising μ to 0.15 moves the neutral point to 1.986° and the forward slip to 1.304%. NPTEL: "the neutral point also shifts towards the exit as the coefficient of friction reduces." A back tension of 20 MPa lowers the slab force to 1572 kN and moves the neutral point to 0.4564°.
How many passes does a big reduction take?
Each pass can take at most μ²R. From 25 mm to 15 mm of low-carbon steel on 250 mm rolls at μ = 0.12 that is 3 passes of up to 3.6 mm. The strip hardens as it goes, so the calculator measures strain from the annealed thickness and averages the flow curve over each pass's own strain range:
This follows from Groover's Ȳf, which is the same average taken from zero. In the example, Ȳf rises from 259.3 MPa in the first pass to 423.8 MPa in the last. The force per pass changes less than the flow stress does, because the last pass is the smallest.
Why does the Week 4 Ansys rolling challenge push the workpiece 90 mm?
Because friction alone could not pull it in. The reports that give the geometry state 25 mm radius rollers (diameter 50 mm, 6 reports) and a 10 mm thick copper workpiece (4 reports). The gap is 6 mm in one report and 4 mm in two. At the course's μ = 0.2, μ²R = 1 mm, while the draft is 4 to 6 mm. Taking the 10 to 6 mm case, the bite angle is 23.07° and the rolls would need μ ≥ 0.426 (with a 4 mm gap, μ ≥ 0.5397). The two reports that work out μ²R = 1 mm then go on to a 6 mm draft without remarking that it is six times the limit.
The analysis is static structural, which has no inertia and no rate. Nothing in it can feed the strip except the prescribed displacement, so the push does the work; the roller rotation only sets how fast the roll surface moves against the copper. How far the roller surface moves is the arc length:
The usual 195° moves a 25 mm roller's surface 85.08 mm, so the copper is pushed 5.777% faster than the rolls turn; 210° gives 91.63 mm, 1.779% slower. Either way the contact has to slip. One report works it out exactly: 90/25 rad = 206.26°, 14.73° per step.
What a static run can and cannot show: the plastic strain and the thickness change in the gap, yes; strain rate, inertia and the forward slip of a self-fed strip, no. For a strip that really feeds itself, use the bite check first and then the slab method above.
The strain to expect follows from the reduction. In plane strain, with no spread, the equivalent plastic strain through the thickness is (2/√3)·ln(h0/hf):
That is 0.5899 for 10 to 6 mm and 1.058 for 10 to 4 mm. The reports' maximum plastic strain has a median of 1.546: above both, so most likely a local peak at a corner or contact edge, not the rolled section. On the Copper Alloy NL bilinear line (280 MPa yield, 1,150 MPa tangent, so H = 1162 MPa) a plastic strain of 1.546 means 2077 MPa: far above copper's real 430 MPa tensile strength, because the line keeps rising. The reports' median maximum stress for the whole set-up, 3107 MPa, is higher still. That is a model result, not a property of copper.
What did 172 rolling reports do?
Skill-Lync read every public rolling report on 23 Nov 2026, as of that date n = 172: 171 are this challenge (138 titled "Week 4- Rolling operation") and one is a different wire-bending exercise. Every count below is backed by a quoted line from the report text (1,549 quotes, each checked). 143 reports show part of their work as images and 9 have almost no text; text inside images is not counted, so each count is a floor.
| Set-up, in text | Reports |
|---|---|
| Static structural analysis (none name transient or explicit) | 88 |
| Large deflection on | 79 |
| Workpiece Copper Alloy NL (non-linear library) | 132 |
| Friction μ = 0.2, of those stating μ | 109 of 114 |
| Cylindrical / revolute joints on the rollers | 106 / 28 |
| 14 load steps, of those stating a count | 121 of 124 |
| Push of 90 mm, of those stating the push | 75 of 81 |
| Total rotation stated (150°: 1, 180°: 2, 195°: 30, 210°: 12, 225°: 1, 206.26°: 1) | 47 |
| Results, in text | Reports | Examples |
|---|---|---|
| Prove the 90 mm from a result (deformation plot or probe) | 121 | 1, 2 |
| ... of which the value shown is more than 1 mm off 90 mm | 16 | 1, 2 |
| "Prove" it by restating the applied 90 mm | 26 | 1, 2 |
| A maximum plastic strain | 111 | |
| ... written in mm (strain has no unit) | 15 | 1, 2 |
| ... above 1 (median 1.546, middle half 1.281 to 1.793) | 102 | |
| A maximum equivalent stress (median 3107 MPa) | 116 | |
| ... above Copper Alloy's 430 MPa tensile strength | 114 | |
| Compare the stress with yield or tensile strength | 8 | 1, 2 |
| Mention the maximum draft / μ²R | 6 | 1, 2 |
| What the conclusion rests on | Reports |
|---|---|
| The workpiece moved 90 mm / the run finished | 66 |
| Restates the result numbers | 59 |
| Explains a mechanism (plastic flow in the gap, spread, stress at the contact) | 15 |
| Judges the stress against the copper's strength | 3 |
| No conclusion in text | 28 |
- Strain is a ratio. 15 reports write the plastic strain in mm, the unit of the directional deformation printed next to it.
- The displacement is the input. A probe that reads back the prescribed 90 mm proves the boundary condition was applied, not that rolling happened. The thickness and the plastic strain are the evidence.
- 114 of 116 stresses are above copper's tensile strength, and 8 reports compare them with it. A bilinear material that never softens, and elastic steel rollers, let the solver report any stress.
What this calculator does not cover
- Roll flattening and elastic recovery (Hitchcock's deformed radius): the rolls are rigid, which underestimates the force for thin, hard strip.
- Hot rolling with strain-rate dependent flow stress; the K and n are for cold, annealed metal.
- Spread: the strip is assumed not to get wider. Fine for sheet, many times wider than thick; not for a narrow bar like the Week 4 workpiece, which spreads sideways (117 reports give a Z deformation, median 6.134 mm).
- Shape rolling, ring rolling and roll design for profiles.
Running the rolling model is the easy part. Knowing that the push, not friction, feeds the strip, and reading a 3,000 MPa stress in a 430 MPa copper, is what CAE teams look for. The rolling operation is a challenge in Skill-Lync's Ansys Workbench course.
Frequently asked questions
What is the roll force formula in flat rolling?
F = Ȳf × w × L: average flow stress Kεⁿ/(1 + n) with ε = ln(h0/hf), times strip width w and contact length L = √(R(h0 − hf)). Groover's 300 mm strip, 25 to 22 mm on 250 mm rolls, needs 1443 kN. With friction and plane strain, F = L w Ȳ'(1 + μL/2h_av) gives 1783 kN.
What is the maximum draft in rolling, and why is it μ²R?
The rolls can only pull the strip in by friction if μ ≥ tan α, where α is the bite angle. For small angles tan α ≈ √(d/R), so the draft d is at most μ²R: with μ = 0.12 and R = 250 mm, 3.6 mm per pass. Any more and the rolls slip.
What is the neutral point in rolling?
The point on the arc of contact where the strip moves at the roll's surface speed. Before it the roll is faster and drags the strip in; after it the strip is faster. Pressure peaks there. For Groover's strip at μ = 0.12 it sits 1.7° from the exit, 7.418 mm from the exit end of the 27.35 mm contact.
What is forward slip in rolling?
Forward slip s = (vf − vr)/vr: how much faster the strip leaves than the roll surface moves. Volume constancy h0v0 = hf vf makes the thinner exit strip faster. For Groover's strip at μ = 0.12 the slab method gives 0.9564%. More friction moves the neutral point towards the entry and raises the forward slip.
How do you calculate rolling power?
Torque per roll T = 0.5 F L, with the force acting at the middle of the contact. Power for both rolls P = 2πNFL/60 in watts, with F in newtons, L in metres and N in rpm. Groover's example: 19.76 kN·m per roll and 206.9 kW at 50 rpm. Some notes put the arm at 0.4L for cold rolling.
Why does the Week 4 Ansys rolling challenge push the workpiece 90 mm?
Because friction alone could not pull it in. With 25 mm radius rollers and μ = 0.2, μ²R = 1 mm, while the copper goes from 10 mm to a 4-6 mm gap. A static structural run has no inertia either, so the prescribed push feeds the strip and the roller rotation only turns the contact.
Related on Skill-Lync
- Manufacturing Processes interactive book: flat rolling with sliders, the same maths (the build checks both agree)
- True stress-strain calculator: why ln(h0/hf), not the engineering strain, goes into the flow curve
- Yield strength calculator: the 0.2% offset and the flow curve's start
- Explicit vs implicit solver: when a forming run needs inertia
- Student project: a rolling report that works out μ²R
- Ansys courses compared
- All free engineering tools
Sources
- University of Basrah, Metal Forming Processes (Ch. 3 notes after Groover): draft, μ²R, L, Ȳf, F = Ȳf w L and the friction bracket, T = 0.5FL with the 0.4L remark, P = 2πNFL/60, forward slip, the friction values, and the two worked examples (SI and inch).
- Mustansiriyah University, rolling lecture (Groover text): the neutral point, "about 20%" for friction, power in kW, the same worked example.
- NPTEL, Analysis of cold rolling: a more accurate method: the von Kármán equation, p − σx = (2/√3)Y, the Bland and Ford solution and neutral point, F = LwȲ'(1 + μL/2h_av) and its worked example.
- Wikipedia, Rolling (metalworking): draught and d_max = f²R. Wikipedia, Strain hardening exponent: the K and n table (Callister, Kalpakjian, ASM Handbook). University of Nova Gorica seminar on rolling (after Lenard): backward and forward regions.
- Ansys example data on GitHub, Copper Alloy: E 110 GPa, yield 280 MPa, tensile strength 430 MPa. The 1,150 MPa tangent modulus of Copper Alloy NL is as 7 reports quote it; H = E·Et/(E − Et) follows from the tangent modulus being the slope against total strain.
- Skill-Lync, all 172 public rolling reports, read 23 Nov 2026; 1,549 quoted lines. scripts/verify/rolling_force.py recomputes every case another way (the slab method re-derived and integrated along x with bisection for the neutral point, Gauss-Legendre averages of the flow curve, the chord geometry, the textbook examples, the Bland-Ford solution), 95 cases; the page checks itself and the book's maths against it at build time (1,370 checks).