Natural gas combustion calculator: Fluent inputs, mixture fraction and NOx with water in the fuel
Methane needs 17.34 kg of Fluent's oxidiser (0.23 O2 by mass) per kg, so a methane jet flame burns where the mixture fraction is 0.0545. Give the fuel by mole, the oxidiser, temperatures, inlet sizes and velocities to get the mass fractions to type in Fluent, hydraulic diameters, Reynolds numbers, the equilibrium temperature and the thermal NO rate as water is added.
It is built for the "Simulating Combustion of Natural Gas" challenge in Skill-Lync's Advanced CFD using ANSYS Fluent course. Skill-Lync read all 292 public reports with that title (267 on topic): in 47 of them 5% water by mole goes in as CH4 0.95 / H2O 0.05, and 24 call those mass fractions. 5% by mole is 0.0558 by mass. Free, no sign-up, runs in your browser.
ANSYS Fluent 12.0 Theory Guide (NOx, mixture fraction) · 40 CFR 60 · NIST WebBook · checked against Cantera (3,653 checks at build) · Updated 22 Nov 2026
Fluent's challenge set-up: fuel 80 m/s, CH4 mass fraction 1, 300 K; air 0.5 m/s, O2 mass fraction 0.23, 300 K. The geometry defaults are read from reports (a 3.3 mm fuel opening, an air inlet 0.082645 m tall, line probes to 0.0852 m). Fuel T 275-600 K, air T up to 1,000 K (NIST viscosity range).
Each point mixes f kg of fuel stream with 1 − f kg of oxidiser at constant pressure and finds the adiabatic equilibrium of 11 gases. Mixtures with as many C as O atoms (C/O ≥ 0.98) are refused: they would hold solid carbon.
The rate is the initial thermal NO formation rate at the peak equilibrium temperature, in ppm (by volume) per millisecond. It is a trend indicator, not your outlet NOx.
The default outlet O2, H2O and CO2 are complete combustion at the first tab's global mixture fraction; the NO value is an example input, not a result. Type yours.
- Fluent fuel-inlet mass fractions
- CH4 1.00000
- What goes in the species boxes (mole fractions only if you tick Specify Species in Mole Fractions).
- Oxidiser mass fractions
- N2 0.77000, O2 0.23000
- Fluent's 0.23 O2 by mass is 20.7% by mole; air at 21% by mole is 0.233 by mass.
- Molar mass
- fuel 16.043, oxidiser 28.840 g/mol
- Water (18.015) is heavier than methane (16.043), so its mass share is larger than its mole share.
- Density (ideal gas)
- fuel 0.6517, oxidiser 1.1715 kg/m³
- Sets the mass flow for a given velocity.
- Viscosity (NIST + Wilke)
- fuel 11.136, oxidiser 18.465 µPa·s
- Pure-gas values from NIST, mixed by Wilke's rule.
- Mass flow
- fuel 4.459e-4, oxidiser 0.01335 kg/s (80.000 and 0.500 m/s)
- Fixed velocity: the fuel mass flow changes as water changes the density.
- Stoichiometric mixture fraction
- 0.05451
- Where the flame sits in a non-premixed flame.
- Stoichiometric oxidiser to fuel ratio
- 17.344 kg oxidiser per kg fuel stream (yours: 29.93)
- Per kg of the whole fuel stream, water included.
- Global mixture fraction and φ
- f = 0.03233, φ = 0.579 (lean overall)
- The outlet's mixture fraction once everything has mixed.
- Hydraulic diameters
- fuel 3.300 mm, air 165.290 mm
- Type these in Fluent's Intensity and Hydraulic Diameter boxes.
- Reynolds numbers
- fuel 15,450, air 5,244
- Inlet flow regime; the jet is turbulent.
- Turbulence intensity and length scale
- fuel 4.79%, air 5.48%; ℓ 0.231 and 11.57 mm
- Fluent User's Guide estimates (Eqs. 7.3-1, 7.3-2).
- Velocity and momentum flux ratios
- u_O/u_F 0.00625, J 7.022e-5
- A strong fuel jet into slow co-flowing air.
- Water vapour limit in the fuel line
- 3.49% by mole at 300 K (yours 0.0%)
- Above it a real fuel line would hold liquid water.
equilibrium (with dissociation)complete combustion, no dissociationequilibrium peak
CO2H2OCOH2O2OHNOO
| f | T equilibrium | T complete | CO2 | H2O | CO | H2 | O2 | N2 | OH | O | H | NO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.0200 | 1174 K | 1175 K | 0.0549 | 0.0449 | 9.17e-10 | 1.03e-10 | 0.146 | 0.755 | 9.37e-7 | 2.92e-9 | 1.64e-13 | 1.31e-4 |
| 0.0400 | 1861 K | 1872 K | 0.11 | 0.0895 | 1.16e-4 | 4.11e-6 | 0.0597 | 0.738 | 5.00e-4 | 2.79e-5 | 1.61e-7 | 0.00263 |
| 0.0545 | 2213 K | 2308 K | 0.136 | 0.119 | 0.00859 | 2.49e-4 | 0.00511 | 0.727 | 0.00166 | 1.13e-4 | 1.29e-5 | 0.00195 |
| 0.0562 | 2221 K | 2297 K | 0.133 | 0.122 | 0.0133 | 3.98e-4 | 0.00231 | 0.726 | 0.00143 | 8.02e-5 | 1.72e-5 | 0.00134 |
| 0.0700 | 2038 K | 2206 K | 0.0885 | 0.126 | 0.0659 | 0.00348 | 2.97e-6 | 0.716 | 1.26e-4 | 8.56e-7 | 1.73e-5 | 3.05e-5 |
| 0.1000 | 1601 K | 2034 K | 0.056 | 0.0979 | 0.139 | 0.0142 | 3.74e-11 | 0.693 | 4.96e-7 | 5.30e-11 | 9.69e-7 | 2.44e-8 |
| Water (mole %) | Fluent input YH2O | fst | Peak T | T at fst | NO at peak (ppm) | O at peak (ppm) | Rate, equilibrium O | Rate, Fluent partial eq. O | Change |
|---|---|---|---|---|---|---|---|---|---|
| 0.0 | 0.0000 | 0.0545 | 2220.9 K | 2212.9 K | 1207 | 136 | 5.97 | 7.09 | base |
| 5.0 | 0.0558 | 0.0576 | 2213.1 K | 2205.4 K | 1173 | 128 | 5.29 | 6.3 | -11.0% / -10.8% |
| 10.0 | 0.1109 | 0.0609 | 2204.4 K | 2197.2 K | 1135 | 120 | 4.63 | 5.52 | -21.9% / -21.5% |
| 15.0 | 0.1654 | 0.0646 | 2194.8 K | 2188.0 K | 1095 | 112 | 3.99 | 4.77 | -32.4% / -31.9% |
| 20.0 | 0.2192 | 0.0688 | 2184.2 K | 2177.8 K | 1051 | 103 | 3.37 | 4.04 | -42.6% / -42.0% |
| 25.0 | 0.2724 | 0.0734 | 2172.2 K | 2166.3 K | 1003 | 94 | 2.78 | 3.35 | -52.4% / -51.7% |
| 30.0 | 0.3249 | 0.0787 | 2158.7 K | 2153.3 K | 950 | 84 | 2.23 | 2.7 | -61.5% / -60.8% |
- Mixture molar mass
- 28.116 g/mol
- NO, wet
- 468.5 ppmv
- NO, dry
- 528.4 ppmvd
- O2, dry
- 9.27% dry
- Corrected
- 268.2 ppmvd at 15% O₂
- NOx as NO2, dry, at the reference O2, 293 K, 101.3 kPa (40 CFR 60.2)
- 513.0 mg/m³
- NOx as NO2, dry, at the reference O2, 0 °C, 1 atm
- 550.4 mg/m³
- Overall lean (φ = 0.58): there is more air than the fuel needs, but a non-premixed flame still burns where the jet has mixed to f_st = 0.0545, near stoichiometric, at the edge of the fuel jet.
- Fluent "Intensity and Hydraulic Diameter": fuel 4.8% and 3.30 mm (a round jet's Dh is its diameter), air 5.5% and 165.3 mm (an annulus: 2 × (r_o − r_i)).
What is the stoichiometric mixture fraction of methane?
0.0545 for pure methane against Fluent's oxidiser of 0.23 O2 by mass, and 0.0552 against air taken as 21% O2 by mole. The mixture fraction is the share of the mass at a point that came from the fuel stream. Fluent's Theory Guide defines it from element mass fractions Z:
At the stoichiometric value, the oxygen at that point exactly burns the carbon to CO2 and the hydrogen to H2O. Counting oxygen atoms needed minus oxygen atoms present per kg of each stream (β), the stoichiometric mixture fraction is:
Water in the fuel carries its own H and O in the ratio that needs no oxygen, so it only dilutes the fuel: fst rises to 0.0787 at 30% water by mole. The default jet case is lean overall (φ = 0.579, global f = 0.0323), but a non-premixed flame does not burn at the global ratio. It burns where the jet has mixed down to fst, at the jet edge, close to stoichiometric and close to the hottest possible temperature.
The 0.23 versus 0.233 detail matters a little: 0.23 by mass is 20.73% O2 by mole, slightly lean of air, and its equilibrium peak is 2221 K against 2234 K for 21% by mole.
How do you enter 5% water by mole in the Fluent fuel inlet?
As mass fractions: CH4 0.9442 and H2O 0.0558. Fluent's User's Guide says "you will need to specify the inlet mass fraction for all species"; the velocity inlet's Specify Species in Mole Fractions option lets you type mole fractions instead. Without it, 0.05 is read as 5% by mass, which is 4.48% by mole.
| Water, % by mole | 0 | 5 | 10 | 15 | 20 | 25 | 30 |
|---|---|---|---|---|---|---|---|
| H2O mass fraction | 0.0000 | 0.0558 | 0.1109 | 0.1654 | 0.2192 | 0.2724 | 0.3249 |
| CH4 mass fraction | 1.0000 | 0.9442 | 0.8891 | 0.8346 | 0.7808 | 0.7276 | 0.6751 |
In the 267 public reports, 47 enter the 5% case as CH4 0.95 / H2O 0.05: 24 call those mass fractions, 10 call them mole fractions and 12 don't say. 2 reports show a mole-to-mass conversion (for example this one). The slip is small at 5% and grows: 30% by mole is 0.3249 by mass. There is also a physical catch: at 300 K and 1 atm water vapour saturates at 3.49% by mole (NIST saturation pressure 3.54 kPa), so every case in the challenge would be wet in a real fuel line. Fluent's species model treats the water as vapour, and so does this calculator.
What hydraulic diameter goes in the fuel and air inlets?
The diameter of the fuel jet, 3.3 mm, and twice the height of the air annulus, 165.3 mm, for the report geometry. In a 2D axisymmetric model both inlets are lines, and their length is a radius or a gap, not a hydraulic diameter:
Fluent's User's Guide recommends the Intensity and Hydraulic Diameter method for internal flows and gives the estimates below; for this case the fuel jet's Reynolds number is 15,450 (intensity 4.8%) and the air's is 5,244 (5.5%). Only 2 of the 267 reports mention the hydraulic diameter at all; one types 0.001652 m, the jet radius, and one computes the air Reynolds number with the 0.082645 m inlet height as the diameter, which halves it.
Viscosities are NIST's pure-gas values mixed by Wilke's rule: 11.14 µPa·s for methane and 18.46 µPa·s for the oxidiser at 300 K. Cantera's kinetic-theory transport (GRI-Mech 3.0 data) gives values 2.8% and 0.8% higher; the Reynolds numbers move by the same share.
Why is the Fluent peak temperature about 2,300 K, and what should it be?
About 2,300 K is what combustion without dissociation reaches, and a two-step eddy-dissipation run has no dissociation. Its species are CH4, O2, CO2, CO, H2O and N2: no OH, H or O. For these streams complete combustion at fst gives 2308 K. Adiabatic chemical equilibrium, with CO2 and H2O partly split into CO, OH, H2, H and O, peaks at 2221 K at f = 0.0562, slightly rich, and is 2213 K at fst. That is what Fluent's non-premixed model with chemical equilibrium tabulates against mixture fraction (the second tab).
23 reports state a peak temperature in their text; 16 of them give 2,300 to 2,312 K, close to the no-dissociation value. The real flame is cooler than both: heat goes to the walls and is radiated, and turbulence keeps the mixture from sitting exactly at the hottest f.
equilibrium (with dissociation)complete combustion, no dissociationequilibrium peak
Methane against 0.23 O2 by mass, both at 300 K and 1 atm. Solid: equilibrium of 11 gases. Dashed: complete combustion, excess fuel left unburnt on the rich side. Adding all 142 C/H/O/N gases of the NASA database changes the equilibrium peak by 0.003 K; GRI-Mech 3.0's 53 species, with its own property fits, by 0.49 K.
Does adding water to the fuel reduce NOx?
It lowers the flame temperature, and thermal NO is very sensitive to temperature. Fluent computes thermal NO from the extended Zeldovich mechanism, with rate constants from Hanson and Salimian:
With no NO present yet, Fluent's quasi-steady rate (Theory Guide Eq. 13.1-9) reduces to the initial formation rate. The O-atom concentration comes from one of Fluent's options: equilibrium (Eq. 13.1-11), partial equilibrium (Eq. 13.1-13) or the solved O species. This calculator also gives the rate with O from its own full equilibrium:
For the report case at the peak (2221 K), equilibrium O is 136 ppm and the initial rate is 5.97 ppm of NO per millisecond (7.09 with Fluent's partial-equilibrium O). Adding water by mole:
| Water (mole %) | Fluent input YH2O | fst | Peak T | T at fst | NO at peak (ppm) | O at peak (ppm) | Rate, equilibrium O | Rate, Fluent partial eq. O | Change |
|---|---|---|---|---|---|---|---|---|---|
| 0.0 | 0.0000 | 0.0545 | 2220.9 K | 2212.9 K | 1207 | 136 | 5.97 | 7.09 | base |
| 5.0 | 0.0558 | 0.0576 | 2213.1 K | 2205.4 K | 1173 | 128 | 5.29 | 6.3 | -11.0% / -10.8% |
| 10.0 | 0.1109 | 0.0609 | 2204.4 K | 2197.2 K | 1135 | 120 | 4.63 | 5.52 | -21.9% / -21.5% |
| 15.0 | 0.1654 | 0.0646 | 2194.8 K | 2188.0 K | 1095 | 112 | 3.99 | 4.77 | -32.4% / -31.9% |
| 20.0 | 0.2192 | 0.0688 | 2184.2 K | 2177.8 K | 1051 | 103 | 3.37 | 4.04 | -42.6% / -42.0% |
| 25.0 | 0.2724 | 0.0734 | 2172.2 K | 2166.3 K | 1003 | 94 | 2.78 | 3.35 | -52.4% / -51.7% |
| 30.0 | 0.3249 | 0.0787 | 2158.7 K | 2153.3 K | 950 | 84 | 2.23 | 2.7 | -61.5% / -60.8% |
Rates in ppm (by volume) per millisecond at the equilibrium peak temperature; change against dry fuel with equilibrium O / partial-equilibrium O. Fuel and air at 300 K, 1 atm, oxidiser 0.23 O2 by mass.
At 30% water the peak falls 62.2 K and the initial thermal NO rate falls 61.5%. Fluent's guide puts it plainly: thermal NO matters above about 1,800 K and its rate doubles for every 90 K above 2,200 K. What this table is not: your outlet NOx. That depends on how long gas stays near the peak temperature, how the jet mixes and how the turbulence-chemistry interaction is modelled, and the reports' outlet values come from those. Use the table for the direction and rough size of the trend, and the CFD for the number.
Why do some reports show soot values like 6.58e-34?
Because the model formed no soot. A mass fraction of 6.58 × 10-34 is that many kg of soot per kg of gas: zero for any practical purpose, and not a result to compare between water cases. 11 public reports tabulate soot mass fractions between 3.3e-38 and 6.6e-27. Fluent's soot models are empirical: the one-step Khan and Greeves model forms soot from the fuel partial pressure, equivalence ratio and temperature, and the Moss-Brookes model nucleates soot from a precursor (acetylene for methane) that the two-step mechanism does not carry, so Fluent falls back on a precursor setting you choose. This calculator gives no soot number.
How do you convert Fluent's NO mass fraction to ppm at 15% O2?
Convert the outlet mass fractions to mole fractions, take out the water for a dry basis, then correct to the reference oxygen. 40 CFR 60 normalises turbine NOx "to a dry basis and to 15 percent oxygen" with 5.9 = 20.9 − 15 as the defined correction value (§60.4213), in the same form it writes out for 7% O2 (§60.56c):
Example input: NO mass fraction 0.0005 with the default case's complete-combustion outlet (0.0936 O2, 0.0726 H2O, 0.0887 CO2 by mass). That is 468.5 ppmv wet, 528.4 ppmvd, with 9.27% O2 dry, so 268.2 ppmvd at 15% O2 and 813.6 ppmvd at 3% O2. 40 CFR 60 reports NOx "expressed as NO2" and defines standard conditions as 293 K and 101.3 kPa:
The formula is undefined at 20.9% dry O2 (air), so the calculator refuses an outlet with that much oxygen.
What do the 267 natural gas combustion reports set up?
Skill-Lync read all 292 public reports titled "Simulating Combustion of Natural Gas" on 22 Nov 2026; 267 are about the combustor (the rest were filed under the title by mistake). 173 give the fuel at 80 m/s, 170 the air at 0.5 m/s and 128 an O2 mass fraction of 0.23. 120 use Fluent's methane-air-2step mixture, which carries H2O and so allows water in the fuel. "Check my numbers" in the fourth tab looks for the slips counted above: the mole fraction typed as a mass fraction, the radius typed as a hydraulic diameter, and a peak temperature read as the adiabatic value.
- 0.05 is the mole fraction typed as a mass fraction. Fluent's inlet boxes take mass fractions unless "Specify Species in Mole Fractions" is ticked; the mass fraction is 0.0558. In 24 of 267 public reports the 5% case is entered as CH4 0.95 / H2O 0.05 and called mass fractions; 2 show a conversion.
- Fuel Dh 0.001652 m is the jet radius (the inlet height in the 2D axisymmetric sketch). A round jet's Dh is its diameter, 0.00330 m.
- Air Dh 0.0826 m is the annulus height r_o − r_i. For an annulus Dh = 4A/P = 2 (r_o − r_i) = 0.16529 m, twice that.
- f_st 0.055 is within 2% of 0.05451.
- 2300 K is within 40 K of the no-dissociation maximum, 2308 K (equilibrium peak 2221 K). The eddy-dissipation species set has no OH, H or O, so it cannot dissociate: expected for EDM, about 87 K above the real adiabatic limit. 16 of the 23 reports that state a peak in their text give 2,300 to 2,312 K.
- A soot mass fraction of 6.58e-34 is 6.6e-34 kg of soot per kg of gas: no soot formed. It is not a result to compare between cases. 11 public reports tabulate values below 1e-25.
The values checked above are typical report entries (5% as 0.05, Dh 0.001652 m and 0.0826 m, fst 0.055, 2,300 K, soot 6.58e-34).
What this calculator does not cover
- Flow, mixing and residence time. It gives the inputs and the thermochemistry. Where the flame sits along the chamber, the outlet NOx and CO, and the effect of the 0.79 m length need the CFD.
- Heat loss. All temperatures are adiabatic. Different inlet temperatures make a Fluent case non-adiabatic in the PDF sense, but the enthalpy of the mixture is still the mass-weighted mix used here.
- Prompt and N2O-route NO, reburning, and the full Eq. 13.1-9 with NO present: only the initial thermal rate is given.
- Soot. No soot number, for the reasons above. Flame length is not estimated either.
- Liquid water. Water is vapour at the inlet temperature, even where it would condense.
Setting up the streams right is the start; knowing why the flame peaks where it does and what water really does to NOx is what combustion and CFD teams look for. Skill-Lync's Fluent and combustion courses teach both.
Frequently asked questions
What is the stoichiometric mixture fraction of methane?
For pure methane against Fluent's oxidiser of 0.23 O2 by mass it is 0.0545: 1 kg of fuel stream burns with 17.34 kg of oxidiser. With air at 21% O2 by mole (0.233 by mass) it is 0.0552. Water in the fuel raises it: 0.0787 at 30% water by mole.
How do I enter 5% water by mole in the Fluent fuel inlet?
Fluent's inlet species boxes take mass fractions unless you tick Specify Species in Mole Fractions. 5% water by mole in methane is 0.0558 H2O and 0.9442 CH4 by mass. Typing 0.05 as a mass fraction gives 4.48% water by mole instead. At 30% by mole the mass fraction is 0.3249.
What hydraulic diameter should I use for the fuel and air inlets?
Dh = 4A/P. For the round fuel jet it is the diameter, 3.3 mm for a 1.65 mm radius, not the radius you see in the 2D axisymmetric sketch. For the air annulus it is 2(ro − ri), 165.3 mm with the report geometry, twice the inlet height.
Why is my Fluent peak temperature about 2,300 K?
Because the eddy-dissipation species set (CH4, O2, CO2, CO, H2O, N2) has no OH, H or O, so the products cannot dissociate. Complete combustion without dissociation gives 2308 K at f_st for these streams. Adiabatic chemical equilibrium, which is what a non-premixed PDF table holds, peaks at 2221 K.
Does adding water to the fuel reduce NOx?
The thermal NO formation rate at the flame's peak temperature falls: by 61.5% at 30% water by mole for the report case, as the peak drops 62.2 K. That is a local rate, a trend indicator. Outlet NOx also depends on residence time, mixing and the turbulence-chemistry model.
How do I convert NO mass fraction to ppm at 15% O2?
Turn mass fractions into mole fractions with each species' molar mass, multiply NO by a million for ppm, divide by (1 − water mole fraction) for dry ppm, then multiply by 5.9/(20.9 − dry O2 %). 40 CFR 60 defines 5.9 as 20.9% minus 15% O2.
Related on Skill-Lync
- Adiabatic flame temperature calculator: 13 fuels against equivalence ratio, with and without dissociation
- NASA polynomial calculator: the property fits behind every temperature here
- Mixing tee calculator and y+ calculator for the rest of the Fluent course
- CFD courses compared
- Student project: simulating combustion of natural gas
- All free engineering tools
Sources
- ANSYS FLUENT 12.0 Theory Guide (2009): 13.1.3 Thermal NOx Formation (rate constants after Hanson and Salimian, Eqs. 13.1-9, 13.1-11, 13.1-13); 8.2.1 Mixture Fraction Theory (Eq. 8.2-1); 13.3.2 Soot Model Theory. User's Guide: 15.1.5 species boundary conditions, 33.7.18 Velocity Inlet (Specify Species in Mole Fractions), 7.3.2 turbulence intensity and length scale (Eqs. 7.3-1, 7.3-2), 21.3.1 soot models. Read 22 Nov 2026.
- US eCFR, Title 40 Part 60: §60.4213(d)(2) (dry basis, 15% O2, 5.9 = 20.9 − 15), §60.56c(b)(5) and §60.106(h)(6) (the correction formula), §60.44b (NOx expressed as NO2), §60.2 (standard conditions 293 K, 101.3 kPa). Read 22 Nov 2026.
- NIST Chemistry WebBook, SRD 69, Thermophysical Properties of Fluid Systems (E. W. Lemmon, M. O. McLinden, D. G. Friend): pure-gas viscosities of CH4, C2H6, C3H8, N2, O2, CO2 and water vapour, and the water saturation curve. Read 22 Nov 2026.
- Cantera 3.2.0 documentation, MixTransport: Wilke's mixture rule. Cantera's equilibrium solver, nasa_gas.yaml and gri30.yaml (GRI-Mech 3.0) for the independent check.
- NASA Glenn thermodynamic data (McBride, Zehe and Gordon, NASA TP-2002-211556) and the CEA equilibrium iteration (Gordon and McBride, NASA RP-1311), through the flame temperature calculator's solver.
- Skill-Lync, all 292 public "Simulating Combustion of Natural Gas" reports, read 22 Nov 2026. scripts/verify/natural_gas.py recomputes every stream, equilibrium state, peak, rate and ppm value with Cantera and scipy, and the page checks itself against it at build time (3,653 checks; worst temperature difference 5.5e-5 K).