Sketch a G+1 residential plan according to Vaastu Shastra and Calculation of Loads as per IS code
AIM
To sketch G+1 villa accoridng to vastu sastra and calculating the live load, dead load and wind load for the villa
find the attached sketch of the villa in which was designed according to vastu sastra recommended directions
Entrance - North
Living room - North west
Pooja room - North east
Guest room - East
Bathroom - West
Master Bedroom - South west
Kithen - South east
Dinning - South
List of Drawings need to be provided
Architectural drawing, Structural drawing, MEP drawing and HVAC drawings are the drawing which needs to provided to the site, Out of these Structrual Drawing is very important and needed very most initially, the list of structural drawings which need to provide intially was
- Column centre line drawing
- Footing layout
- Column section and reinforcement details
- Plinth beam / Tie beam layout
- Groundfloor beam layout and reinforcement details
- Firstfloor beam layout and reinforcement details
Load Calculation
Dead Load as per IS875 part 1
Live Load as per IS 875 part 2
Wind load for above building 10m, But our villa below 10m
Column was assumed on all corner and dimension 300*300
Beam was assumed with dimension 450*230
Flight Height assumed 4.5 m
Slab thickness 250mm
Dead Load on the strucutre as per IS 875 part I
Unit Weight of RCC = 25kN/`m^3`
Slabs = 1*1*.25*25 = 6.25kN/m
Column = .3*.3*4.5*25 = 10.125 kN
Bean = .45*.23*1*25 = 2.58 kN/m
Brick Wall = 1*4.5*.23*20 = 2.07kN / m
Live Load As per IS 875 part II
Living - 2kN /`m^2`
Pooja room- 2kN /`m^2`
Guest Room- 2kN /`m^2`
Bath room- 2kN /`m^2`
Master bed room- 2kN /`m^2`
Kitchen- 2kN /`m^2`
Dining- 2kN /`m^2`
Terrace- 3kN /`m^2`