Project 1_Comparative study of different storey buildings for Seismic forces
Project-1
Influencing Factors- As per given data design model and analysis and finding following result, Also attached all model .
| Criteria | Analysis | Result |
| Effect of stiffness on time period | Building E(10 storey varriying column size) | 1.571 s |
| Building F(10 storey uniform column size) | 1.608 s | |
| Building G(Varriying column size) | 3.01 s | |
| Building F( Uniform column size) | 2.024 s | |
| Effect of mass on time period | Building H (25 storey with 3kn/sqm) | 2.024 s |
| Building I (25 storey with 3.30kn/sqm) | 2.063 s | |
| Building J (25 storey with 3.60kn/sqm) | 2.066 s | |
| Effect of building height on time Period | Building A ( 2 storey) | 0.453 s |
| Building B ( 5 storey) | 0.934 s | |
| Building F ( 10 storey) | 1.608 s | |
| Building H ( 25 storey) | 2.024 s | |
| Effect of column orientation on time period | Building B (All Floor column size 400X400 | 0.934 s |
| Building c (All Floor column size 550X300 in X-direction) | 1.032 s | |
| Building D (All Floor column size 550X300 in Y-direction) | 1.01 s | |
| Effect of Flexural stiffness of structural elements on mode shape | Building B (Full flexural stiffness of beam) | 0.934 s |
| Building B (Flexural stiffness of beam close to nill ) | 2.368 s | |
| Effect of Axial stiffness of vertical members on mode shape | Building H ( Full Axial X-Section of column ) | 2.024 s |
| Building H ( Axial X-Section of column is close to nill ) | 4.96 s | |
| Effect of defree of fixity at column base on mode shape | Column support pinned | 0.934 s |
| Column support Fixed | 0.848 s |