Identification of Cracks
1) What is the mode of failure or damage of the beams in the figure above? Are the damages repairable?
a)

Observation-
- In this Picture concrete crushed & Reinforcement exposed, Concrete spalled beyond the reinforcement which may be sign of rupture.
- Beam top portion looking safe beacause advantage of flange from slab.
- The crack develops from bottom to top beacause reinforcement yielding occurs in support bottopm only.
Ans -
- It is form of flexural failure due to reversal of stress during earthquack, During stress reversal support of top experiences compression and bottom in tension.
- Top compression is manage by slab advantage and bottopm tension was not staisfied by provided reinforcement since reinforcement got yoelded .
- It can be not repairable.
b)

Obeservation -
- In this picture cracks along beam and column edge, cracks seems to have developed through the structurs as it looks much wider.
- Beam looks separated from the coloumn at joints
- concrete looking is not severely crushed.
Ans-
- In this picture beam pullout failure due to insufficient development length of reinforcement at joint.
- During earthquke the horizontal movement of structure make this condition and detached the beam from column .
- Providing anchroge length between two existing concrete is very difficult , so not repairable.
c)

Observation -
- Cracks are exactly at the joint of column beam.
- Cracks in beam developed through its entire width .
- Slab also developed more cracks along the beam direction.
Ans -
- In this picture it is plastic hinge failure and damage occured only in joint zone due cylic lateral loading and strees reversal at joints .
- Even the slab participated to its best to handle the tension but unable to control thr damaged.
- Joint can be strenghthend.
2. a)

Observation-
- Concrete damaged at top of coloumn and all arround and beam is safe.
- No walls are built along the coloumn means it is probably at ground floor for parking.
Ans -
- In this image it is a soft storey failure due to plastic hinge formation.
- Due to absence of infill wall at the ground floor the plastic hinge forms at the top of ground storey columns during latral movement.
- Based on the development of crush of concrete it can be repairable.
2. b)

Observation -
- in this picture concrete developed complete breakage diagonally and longitudional reinforcement are intact.
- Shear reinforcement spacing is more , so probably less shear reinforcement provided.
Ans-
- In this picture it is a shear failure .
- Inadequate shear reinforcement completes , concrete takes all the shear stress.
2. c)

Observation -
- Coloumn failed completely at top.
- There are two slabs connected to the coloumn one at mid height of coloumn.
Ans -
- In this picture it is a short coloumn failur due to additional slab / beam connected to a column in mid height loads to this effect.
- The failure given in this picture is not repairable.