Design of Tensile Membrane Structure
Notes written by Skill-Lync from the recording · Updated 17 Nov 2026
What this workshop covers
Design of tensile membrane structures explained: membrane vs plate behaviour, types, fabrics like PTFE and ETFE, form finding, cutting patterns and prestress.
In this Skill-Lync workshop, recorded in January 2021, the instructor starts from why membranes are used (long column-free spans, light weight, daylight, low maintenance) and how a membrane differs from a plate: it carries load through in-plane tension and has no bending stiffness. The session then tours applications from facades and stadium roofs to landmark projects such as the Millennium Dome and Denver International Airport, and notes that in 2021 the instructor saw membranes as still uncommon in India outside airports, events and parking shades.
The technical half covers structure types (point supported, saddle, mast and arch supported), the four common fabrics, the essential elements of a membrane system and the three-step design approach of form finding, analysis and cutting pattern generation, closing with three RFEM examples that show how isotropic and orthotropic prestress change the final shape. It suits civil engineering students and structural engineers new to fabric structures. The instructor works from slides only: there is no live software demo, no wind or snow load design and no code checks.
Chapters
- 0:06 Why tensile membrane structures are gaining ground
- 2:04 Membrane vs plate: in-plane stress, no bending stiffness
- 6:20 Advantages: long spans, daylight, low maintenance
- 8:50 Applications, landmark projects and use in India
- 14:05 Membrane design software and RFEM 5
- 17:22 Structure types and membrane fabrics
- 20:58 Essential elements and the three-step design approach
- 25:05 Design prerequisites: prestress, self weight, loads
- 27:11 RFEM examples: isotropic vs orthotropic prestress
Key points from the session
- A membrane resists transverse load through in-plane tensile stress, like a balloon being inflated, and has zero bending stiffness. Plates, such as slabs and shear walls, resist load through bending, which is why membranes need a different design approach.
- Design follows three steps: form finding (prestress the fabric and cables until the shape reaches spatial equilibrium), analysis (check how that form behaves within the main model) and cutting pattern generation (flatten the 3D form into 2D fabric panels that are stretched back into shape on site).
- Form follows force: unlike a conventional building where the shape is fixed first and forces are found later, a membrane's shape is the result of the prestress applied through cables and supports.
- Self weight and expected loads should be considered during form finding. If they are added only after equilibrium is reached, the fabric can sag into a different shape and the form finding has to be repeated.
- Temporary supports can stand in for cables or beams during form finding, because that stage only solves shape equilibrium. They disappear when the form is brought back into the main model with the real members.
- The four fabrics covered are polymer-coated polyester, PTFE-coated fiberglass (which the instructor says lasts about 35 to 40 years), PVDF-coated fabric for stain resistance, and transparent ETFE film, which the instructor puts at about 1% of the weight of glass.
- In the RFEM examples, an isotropic prestress of 1 kN/m in the membrane with 10 kN in the cables gives a symmetric shape, while orthotropic prestress (1 kN/m in the warp direction, 2 kN/m in the weft) visibly deepens one side. Swapping the ratio changes the shape again.
What is form finding in tensile membrane structure design?
Form finding is the analysis that finds the shape at which a prestressed membrane reaches equilibrium. Prestress is applied to the fabric and its supporting cables, and the fabric stretches into a stable 3D form. Only after this shape equilibrium is reached is the form transferred to the main model for analysis.
Why do tensile membranes need cutting patterns?
Fabric is made and delivered as flat 2D sheets, but the form found by analysis is a 3D surface. Cutting pattern generation works out the 2D panel shapes that, once cut, joined and stretched with prestress on site, will reproduce the required 3D shape of the membrane.
How does prestress change the shape of a membrane?
The instructor's arch-supported example loads three identical panels differently. Uniform isotropic prestress of 1 kN/m gives a symmetric surface, while orthotropic prestress of 1 kN/m in warp and 2 kN/m in weft creates a deeper depression on one side. Reversing the ratio gives yet another shape.
Where to go next
Who should watch
For Civil Engineers
A 26 Jan 2021 workshop recording from Skill-Lync on DESIGN. For a structured course with projects on this topic, see Skill-Lync's civil engineering courses.