Electrical Drives cover
Interactive book · Semester 4-7

Electrical Drives

Run a crane hoist through all four quadrants, start a DC motor on its current limit, slow a fan with V/f and steer an induction motor's flux with vector control

28 chapters, 28 interactives, few words. Every chapter is mapped to the Anna University, VTU, SPPU, Mumbai University and KTU units it covers: drive dynamics and four-quadrant operation, equivalent inertia, load torques and stability, starting and braking losses, load equalization, heating, duty classes and motor rating, DC motor braking, rectifier- and chopper-fed DC drives, discontinuous conduction, current and speed loops, field weakening, stator voltage and V/f control, VSI and CSI drives, slip power recovery, the d-q model, vector control, direct torque control, synchronous motor and PMSM drives, BLDC, switched reluctance and stepper drives. Motor construction and the torque-slip curve are in the Electrical Machines book, and the converters themselves in the Power Electronics book.

  • AUEE3012Electrical Drives
  • VTUBEE613DElectric Motor and Drive Systems for Electric Vehicles
  • SPPU404191(B)Industrial Drives and Control
  • MUEEC701Electrical Drives and Control
  • KTUPCEET403Power Electronics and Drives (Module 4)

By Skill-Lync · Updated 21 Nov 2026 · 28 chapters · 28 interactives · free, no sign-up

Chapter 1

What an electric drive is: its parts, why adjustable speed, and the energy a drive saves

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 1KTU PCEET403 Module 4

What are the parts of an electric drive?

A drive is everything that turns electrical energy into controlled motion. The source (the 415 V, 50 Hz mains or a battery) feeds a power converter (a rectifier, chopper or inverter) that sets the voltage and frequency the motor sees. The motor turns the load: a fan, a pump, a hoist drum or a spindle. A controller compares what is wanted (a speed, a torque, a pressure) with what sensors report (current, speed, position) and tells the converter what to do. Take away the converter and the controller and you have a fixed-speed motor.

Why use an electric drive and why adjust its speed?

Electric motors cover milliwatts to many megawatts, start at once, need no idling, and can run in both directions, brake, and even return braking energy to the supply. They are clean and quiet at the point of use. Motors take a large share of all electricity: one widely quoted estimate puts it at 60-65 %. Most machines do not need full speed all the time: a conveyor follows the production rate, a lift must slow before a floor, a fan must follow the demand. Adjusting the speed electrically does this with far less waste than a mechanical brake, a valve or a damper.

Why does slowing a fan or pump save so much energy?

Affinity laws: flow follows speed, head follows speed squared, so shaft power follows speed cubed. An illustrative 150 kW process fan held at 70 % flow by a damper still draws 143.9 kW from the mains, because the fan runs at full speed and the damper burns the extra pressure. Slowed by a drive to 70 % speed it draws 57.7 kW, saving about ₹41.4 lakh a year at an assumed 6,000 h and ₹8/kWh. On-off cycling sits between, at 114.1 kW. The catch: at full flow the drive's own 3 % loss makes it slightly worse.

Why variable speed saves energy: a fan or pump throttled with a damper against slowed down by a drive, power against flow: interactive loads as you scroll

DC drive or AC drive: how is the choice made?

Start from the load: speed range, how many quadrants, how fast the speed must change, starting torque, the environment and the cost of running it for years. A DC motor with a controlled rectifier or chopper is simple to control, because torque follows armature current directly, but its brushes and commutator need maintenance and limit speed and power. A cage induction motor with an inverter is cheaper, sealed and rugged. Since the IGBT (introduced in 1983) came to dominate inverters and fast processors made vector control routine, the inverter-fed cage motor has become the common choice for new machines; DC drives remain in older plants and simple battery machines.

Predict, then check

A centrifugal fan with no static head is slowed by a drive to 80 % speed. Roughly what fraction of its full-speed shaft power does it now need?

Worked examples

Affinity laws for a pump slowed by a drive · A centrifugal pump at 1,450 rpm gives 120 m³/h at 32 m head and needs 14 kW at the shaft; the drive slows it to 1,160 rpm (illustrative; no static head, same efficiency at the similar point)
  1. Speed ratio = 1,160/1,450 = 0.8
  2. Flow ∝ n: Q = 120 × 0.8 = 96 m³/h
  3. Head ∝ n²: H = 32 × 0.8² = 20.48 m
  4. Power ∝ n³: P = 14 × 0.8³ = 7.168 kW

Answer: 96 m³/h at 20.48 m, 7.17 kW: 80 % flow for 51.2 % of the power

Damper against drive at 60 % flow · The interactive's fan: H = 1.4 − 0.4Q² per unit at full speed, system H = Q², 1 per-unit Q·H = 120 kW, fan efficiency 0.80(1 − 0.5(Q/n − 1)²), motor 0.92, drive 0.97; 6,000 h/yr at ₹8/kWh (assumed)
  1. Damper (full speed): head at Q = 0.6 is 1.4 − 0.4 × 0.36 = 1.256; efficiency 0.736
  2. Shaft = 0.6 × 1.256 × 120/0.736 = 122.9 kW; input = ÷ 0.92 = 133.6 kW
  3. Drive: with no static head the speed equals the flow ratio, n = 0.6; head = 0.6² = 0.36; efficiency stays 0.80
  4. Shaft = 0.6 × 0.36 × 120/0.8 = 32.4 kW; input = ÷ (0.92 × 0.97) = 36.3 kW
  5. Saving = 97.2 kW × 6,000 h × ₹8 = ₹46.7 lakh a year

Answer: 133.6 kW with the damper against 36.3 kW with the drive: about ₹47 lakh a year

A pump lifting against static head saves less · Same fan curve used as a pump, system H = 0.4 + 0.6Q² (40 % static head), flow 70 %
  1. Speed needed: n² × 1.4 − 0.4 × 0.49 = 0.4 + 0.6 × 0.49, so n = √(0.6357) = 0.797, not 0.7
  2. Head = 0.4 + 0.294 = 0.694; Q/n = 0.878, efficiency = 0.794
  3. Shaft = 0.7 × 0.694 × 120/0.794 = 73.4 kW; input = 82.3 kW
  4. The cube law alone would have promised 150 × 0.7³/(0.92 × 0.97) = 57.7 kW

Answer: 82.3 kW at 79.7 % speed: still far below the damper's 143.9 kW, but the static head eats part of the cube-law saving

Chapter 2

Motor-load dynamics: the torque equation, speed-torque conventions and four-quadrant operation

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 1KTU not in syllabus

What is the fundamental torque equation of a drive?

Newton's law for rotation at the motor shaft: the motor torque T minus the load torque TL accelerates the total inertia J. If T equals TL the speed stays constant; any surplus accelerates, any deficit decelerates. For the illustrative crane hoist lifting 2 t, the gravity torque at the motor is 123.6 N·m, friction 5 N·m, and reaching 100 rad/s in 2 s with J = 0.4756 kg·m² needs another 23.8 N·m, so the motor must give 152.4 N·m while it speeds up and 128.6 N·m once steady.

Which signs do speed, motor torque and load torque take?

Choose one direction of rotation as positive (for a hoist, lifting). Motor torque is positive when it pushes in that direction; load torque is positive when it opposes it. Then the power the motor delivers is P = T·ω. When T and ω have the same sign, P is positive and the machine is motoring; when they have opposite signs, P is negative and the machine is braking: the load is driving it, and the energy flows back to the supply or into a resistor. Plot T horizontally and ω vertically and these cases fall into four quadrants.

How does a crane hoist use all four quadrants?

Lifting 2 t at steady speed, T = 128.6 N·m and ω = +100 rad/s: quadrant I, motoring. Even slowing the lift needs positive torque (104.8 N·m), since gravity does the braking. Lowering the same load at steady speed, ω = −100 rad/s but T stays +118.6 N·m to hold it back: quadrant IV, braking, 11.86 kW returned. With an empty hook the motor must drive downwards to speed up the descent (−19.3 N·m: quadrant III) and brake the rise to a stop (−9.3 N·m: quadrant II). A train uphill is quadrant I, downhill on its brakes quadrant II.

A crane hoist in all four quadrants: torque, speed and power signs while lifting, lowering, accelerating and braking: interactive loads as you scroll

What is the difference between active and passive load torques?

A passive load torque always opposes motion and flips sign when the motion reverses: friction, cutting, a fan. It can never drive the motor. An active load torque keeps its sign whichever way the shaft turns: gravity on a hoist, a compressed spring, a vehicle on a slope. It can drive the motor, which is why lowering a load brakes. In the hoist, lifting 2 t by 12 m takes 257.2 kJ from the motor and lowering it gives back 237.2 kJ; the 20 kJ difference is the friction work of both trips.

Predict, then check

A crane lowers a heavy load at a steady speed. In which quadrant does its hoist motor operate?

Worked examples

Torque to start a lift · Hoist: drum radius 0.3 m, gear 50:1, payload + hook 2,100 kg, motor-side inertia 0.4 kg·m², friction 5 N·m at the motor; rope speed 0.6 m/s reached in 2 s (illustrative, gearbox losses in the friction)
  1. Motor speed at 0.6 m/s: ω = v·a/r = 0.6 × 50/0.3 = 100 rad/s; α = 100/2 = 50 rad/s²
  2. Gravity torque at the motor: TL = m·g·r/a = 2,100 × 9.81 × 0.3/50 = 123.61 N·m
  3. Total inertia: J = 0.4 + 2,100 × (0.3/50)² = 0.4756 kg·m²
  4. T = TL + Tf + J·α = 123.61 + 5 + 23.78 = 152.39 N·m
  5. Power at the end of the ramp: P = T·ω = 152.39 × 100 = 15.24 kW

Answer: 152.4 N·m while accelerating, peak 15.2 kW, quadrant I

Lowering the load: regenerative braking · The same hoist lowers 2,100 kg at a steady 0.6 m/s (ω = −100 rad/s) for the 10.8 m of travel at full speed
  1. Friction now opposes the downward motion, so it helps to hold the load: T = TL − Tf = 123.61 − 5 = 118.61 N·m
  2. P = T·ω = 118.61 × (−100) = −11.86 kW: negative, the load drives the motor (quadrant IV)
  3. Steady part takes 10.8/0.6 = 18 s, so 11.86 kW × 18 s = 213.5 kJ comes back at the shaft
  4. Whether it reaches the mains depends on the drive: a regenerative front end returns it, a plain diode rectifier needs a braking resistor

Answer: 118.6 N·m holding torque, 11.9 kW generated, 213 kJ in the steady part

An EV scooter uphill and downhill · Scooter + rider 180 kg, wheel radius 0.2 m, motor-to-wheel gear 8:1, 10 m/s, 6 % grade, rolling resistance 0.015 (illustrative; air drag neglected)
  1. Grade angle = atan(0.06); gravity force = 180 × 9.81 × sin = 105.8 N; rolling force = 0.015 × 180 × 9.81 × cos = 26.4 N
  2. Motor speed = 10/0.2 × 8 = 400 rad/s
  3. Uphill: T = (105.8 + 26.4) × 0.2/8 = 3.3 N·m, P = 1322 W: quadrant I
  4. Downhill: gravity now helps: T = (−105.8 + 26.4) × 0.2/8 = −1.98 N·m at +400 rad/s
  5. P = −793 W: quadrant II, the motor brakes and can charge the battery

Answer: Uphill 3.3 N·m (quadrant I, 1.32 kW); downhill −1.98 N·m (quadrant II, 0.79 kW regenerated)

Chapter 3

Equivalent values: inertia and torque referred through gears, belts and hoists, and measuring J

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 1KTU not in syllabus

How is a load's inertia referred to the motor shaft?

Replace the whole train by one inertia at the motor that stores the same kinetic energy. A load turning a times slower than the motor stores ½·JL·(ωm/a)², so it counts as JL/a² at the motor; a mass m moving at v counts as m·(v/ωm)². With the book's 7.5 kW motor (rotor 0.03 kg·m², illustrative) and a 3 kg·m² load through a 6:1 gearbox, J_eq = 0.03 + 3/36 = 0.1133 kg·m²: the big load looks small through the gear.

How is load torque referred, and where does gear efficiency go?

Equate power. When the motor drives the load, the gearbox loss must also be supplied, so the motor sees TL/(a·η). When the load drives the motor (lowering a hoist, a vehicle downhill), the loss is taken from the load's power, so the motor sees TL·η/a. With TL = 150 N·m, a = 6 and η = 0.95, the motor sees 26.32 N·m when driving and 23.75 N·m when driven: the gearbox always works against the power flow.

Which gear ratio accelerates a load fastest?

The load's acceleration is a·Tm/(a²·Jm + JL). Too small a ratio leaves the motor too little torque advantage; too large a ratio makes the motor spin its own rotor uselessly fast. With no load torque the best ratio makes the referred load inertia equal the rotor inertia: a* = √(JL/Jm) = √(3/0.03) = 10, giving 82.9 rad/s² against 73.2 rad/s² at a = 6. A 150 N·m load torque pushes the best ratio up to 13.7. Servo designers call this inertia matching.

Referring a load through a gearbox: equivalent inertia and torque at the motor shaft, the best gear ratio, and the retardation test: interactive loads as you scroll

How is the moment of inertia of a drive measured?

The retardation (coast-down) test. Run the machine at no load slightly above the test speed, switch off, and record speed against time. The only torque left is the no-load loss, so J·dω/dt = −W/ω. Measure the loss W at that speed from a no-load run (input minus copper loss), draw the tangent to the speed curve at that speed, and J = W/(ω·|dω/dt|). For the interactive's motor at 100 rad/s, W = 51.8 W and the slope is −8.64 rad/s², giving J = 0.06 kg·m².

Predict, then check

A motor with rotor inertia 0.02 kg·m² must accelerate a 0.5 kg·m² load (no load torque) as fast as possible. Which gear ratio should it use?

Worked examples

Equivalent inertia of a conveyor · Motor rotor 0.03 kg·m²; 20:1 gearbox; drum 1 kg·m², radius 0.1 m; 600 kg on the belt; motor at 150 rad/s (illustrative)
  1. Drum: 1/20² = 0.0025 kg·m²
  2. Belt mass: v = 0.1 × 150/20 = 0.75 m/s, so m·(v/ωm)² = 600 × (0.75/150)² = 0.015 kg·m²
  3. J_eq = 0.03 + 0.0025 + 0.015 = 0.0475 kg·m²
  4. Check by energy: ½ × 0.0475 × 150² = 534.4 J = rotor 337.5 + drum 28.1 + belt 168.8 J

Answer: J_eq = 0.0475 kg·m²; the 600 kg belt load adds only 0.015 kg·m²

Hoist torque referred through a lossy gearbox · 2,100 kg on a 0.3 m drum, 50:1 gearbox with efficiency 0.9 (illustrative)
  1. Torque at the drum: 2,100 × 9.81 × 0.3 = 6180.3 N·m
  2. Lifting (motor drives the load): 6180.3/(50 × 0.9) = 137.34 N·m at the motor
  3. Lowering (load drives the motor): 6180.3 × 0.9/50 = 111.25 N·m at the motor
  4. Lossless value would be 123.61 N·m: the loss adds when lifting and subtracts when lowering

Answer: 137.3 N·m lifting, 111.2 N·m lowering

Inertia from a retardation test · No-load test at 1,000 rpm: mechanical and core losses 600 W. After switching off, speed falls from 1,010 to 990 rpm in 0.8 s (illustrative)
  1. ω = 1,000 × 2π/60 = 104.72 rad/s
  2. Slope near 1,000 rpm: dω/dt = (20 × 2π/60)/0.8 = 2.618 rad/s²
  3. J = W/(ω·|dω/dt|) = 600/(104.72 × 2.618) = 2.189 kg·m²

Answer: J ≈ 2.19 kg·m²

Chapter 4

Load torques and steady-state stability

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 1KTU not in syllabus

What shapes do load torques take against speed?

Four shapes cover most machines. Constant torque: hoists, conveyors, positive-displacement pumps; the torque is the same at every speed. Torque ∝ speed: viscous friction, some calenders. Torque ∝ speed²: fans, centrifugal pumps, ship propellers. Torque ∝ 1/speed (constant power): winders and lathe spindles cutting at constant power. At half speed a fan needs 25 % of its torque, a constant-power load 200 %. Some loads have a hump, and presses and compressors vary with time within a revolution; chapter 6 treats those.

When is an operating point stable?

The drive settles where motor torque equals load torque, a crossing of the two curves. Nudge the speed up a little. If the load torque now rises more than the motor torque, the net torque is negative and the speed falls back: stable. If the motor torque rises more, the surplus accelerates it further: unstable, and the speed runs away to another crossing, to standstill or to a limit. So compare slopes at the crossing: the load curve must be steeper (in the direction of rising speed) than the motor curve.

Why can an induction motor with a constant load have two operating points?

Its torque curve rises from 77.5 N·m at standstill to 141.6 N·m and then falls steeply towards synchronous speed. A constant load of 89.5 N·m (180 % of rated) crosses it twice: at 144 rad/s, where the motor torque falls with speed (−4.87 N·m per rad/s), stable; and at 27.7 rad/s, on the rising part, unstable. A small kick at the lower point sends the motor up to the upper one. Since the load exceeds the starting torque, the motor cannot start it from rest at all.

Motor and load speed-torque curves: where they cross, and whether that operating point is stable: interactive loads as you scroll

Can a motor curve that rises with speed ever be stable?

Yes, if the load rises faster. Demagnetising armature reaction can make a DC shunt motor's speed rise with load. With a constant rated load it then runs at 188.1 rad/s with a motor slope of +2.63 N·m per rad/s: unstable, it races or stalls. Couple a fan load instead (80 % of rated at rated speed) and the upper crossing at 224.6 rad/s is stable, because the fan torque climbs faster. A DC series motor is stable but races at light load: with a fan needing 20 % torque it runs at 241 rad/s, so it is never left unloaded.

Predict, then check

An induction motor has 77.5 N·m starting torque and 141.6 N·m maximum torque. A constant 100 N·m load is coupled to it at rest and the motor is switched on. What happens?

Worked examples

DC shunt motor with a constant load · The book's DC motor: 220 V, Ra 0.4 Ω, K = 1.273 N·m/A, J = 0.2 kg·m²; constant load 50 N·m
  1. Current = 50/1.2732 = 39.27 A; speed = (220 − 39.27 × 0.4)/1.2732 = 160.45 rad/s
  2. Motor slope: T = K(V − Kω)/Ra, so dTm/dω = −K²/Ra = −4.053 N·m per rad/s; load slope 0
  3. 0 > −4.053: stable
  4. A disturbance dies away with τ = J/(K²/Ra) = 0.2/4.053 = 49.3 ms

Answer: Stable at 160.5 rad/s (1532 rpm); disturbances decay in about 49 ms

Two crossings of an induction motor · The book's 7.5 kW motor (starting torque 77.5 N·m, maximum 141.6 N·m, J = 0.06 kg·m²) with a constant 100 N·m load
  1. Scan the torque curve against 100 N·m: crossings at 141.71 rad/s (slip 0.0978) and 47.12 rad/s
  2. Upper point: dTm/dω = −4.195 N·m per rad/s, below the load's 0: stable
  3. Lower point: dTm/dω = +0.586: above 0, unstable
  4. At the upper point a disturbance decays with τ = J/|slope| = 0.06/4.195 = 14.3 ms
  5. Since 77.5 N·m is less than 100 N·m, the motor must be started before this load is applied

Answer: Stable at 141.7 rad/s, unstable at 47.1 rad/s

A fan on an induction motor · Fan torque equal to the motor's rated 49.75 N·m at its rated speed 150.76 rad/s, varying as ω²
  1. The curves cross once, at rated speed 150.76 rad/s
  2. Fan slope: dTL/dω = 2 × 49.75/150.76 = 0.66 N·m per rad/s
  3. Motor slope at rated: −6.959 N·m per rad/s
  4. 0.66 > −6.959: stable; a fan load is stable on almost any motor curve because its torque rises with speed
  5. With a fan half as heavy the single crossing moves up to 153.96 rad/s, still stable

Answer: One stable point at 150.8 rad/s; slopes 0.66 (load) against −6.96 (motor)

Chapter 5

Starting, braking and reversing: time and energy loss in transient operation

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU not in syllabusMU EEC701 Module 1KTU not in syllabus

How long does a motor take to reach speed?

The torque equation J dω/dt = Te − TL says the net torque accelerates the inertia, so the time is the integral of J dω/(Te − TL) from the start speed to the end speed. Te changes along the speed-torque curve, so the integral is done in steps. For the book's 7.5 kW motor with a total J of 0.3 kg·m², a direct-on-line start reaches within 0.5 % slip of its final speed in 0.5 s with no load and 0.63 s with a constant 50 % load. Using the steady-state curve ignores electrical transients, a fair approximation when the start lasts many electrical cycles.

Why does a direct-on-line start heat the rotor so much?

The rotor copper loss is s times the air-gap power, and at no load all the torque goes into acceleration. Integrating gives a rotor loss of ½Jωs², exactly the kinetic energy stored at synchronous speed, whatever the shape of the torque curve. With J = 0.3 kg·m² that is 3.7 kJ in the rotor, plus 4.24 kJ in the stator, every start. A load makes it worse: 4.95 kJ in the rotor with 50 % constant torque. Frequent starts are limited by this heat, not by the motor's running rating.

Starting and stopping an induction motor: acceleration time and the energy lost in the rotor, direct-on-line against a frequency ramp: interactive loads as you scroll

What does a plugging stop cost?

Plugging swaps two supply phases, so the field turns backwards and the slip runs from about 2 down to 1 as the rotor slows. The same integral, ½Jωs²(s1² − s2²), gives ½Jωs²(4 − 1): three times the stored energy goes into the rotor, 11.1 kJ for J = 0.3 kg·m², with another 12.69 kJ in the stator. The stop is quick, 0.85 s here, but the supply must be cut at standstill or the motor starts in reverse. A full reversal, plugging then accelerating backwards, costs 4 × the stored energy.

How do you cut the energy lost in starting and stopping?

Keep the slip small. A V/f drive ramps the frequency, so synchronous speed rises gradually and the rotor follows a few percent behind. A 3 s ramp at no load loses 0.077 kJ in the rotor against 3.7 kJ for direct-on-line, and the current peaks at 10.6 A instead of 76.2 A. Starting in steps on a pole-changing motor halves the loss, and a lighter J reduces it in proportion. The catch: with a small J and a load, a long ramp keeps the load slipping for longer. At J = 0.06 kg·m² and 50 % load the ramp still loses 0.26 kJ against 0.99 kJ.

Predict, then check

A motor is started direct-on-line with no load. At full speed the rotating parts store 5 kJ. About how much heat is generated in the rotor during the start?

Worked examples

Rotor heat in starting, plugging and reversing · A 4-pole, 50 Hz cage motor drives a load with total J = 0.8 kg·m² and no load torque; it is started 6 times an hour (illustrative)
  1. ωs = 2π × 50 / 2 = 157.08 rad/s; stored energy ½Jωs² = 0.5 × 0.8 × 157.08² = 9.87 kJ
  2. DOL start (s from 1 to 0): rotor loss = ½Jωs²(1² − 0²) = 9.87 kJ
  3. Plugging stop (s from 2 to 1): ½Jωs²(2² − 1²) = 3 × 9.87 = 29.61 kJ
  4. Reversal (plug, then start backwards: s from 2 to 0): ½Jωs²(2² − 0²) = 39.48 kJ
  5. 6 starts an hour add 6 × 9.87 kJ / 3600 s = 16.4 W of rotor heat on average, on top of the running losses

Answer: 9.87 kJ per start, 29.6 kJ per plugging stop, 39.5 kJ per reversal

Quick estimate of a start time · The book's 7.5 kW motor with J = 0.3 kg·m² and a constant 50 % load (24.9 N·m); take the motor torque as an average 100 N·m over the start, to the rated speed of 1,440 rpm
  1. ω = 1,440 rpm = 150.8 rad/s; net torque = 100 − 24.9 = 75.1 N·m
  2. t = J·ω / (T − TL) = 0.3 × 150.8 / 75.1 = 0.602 s
  3. Step-by-step integration with the full torque curve gives 0.63 s to within 0.5 % slip of the final speed
  4. The integration is the same as a constant motor torque of J·ω/t + TL = 97.9 N·m, so 100 N·m was a fair guess; the torque curve's 141.6 N·m peak does not mean a 141.6 N·m average

Answer: About 0.6 s by the average-torque estimate (0.63 s by integration)

Starting in two steps on a pole-changing motor · A two-speed 8/4-pole, 50 Hz motor, total J = 0.5 kg·m², no load (illustrative)
  1. Direct to 4-pole: rotor loss = ½Jωs² = 0.5 × 0.5 × 157.08² = 6.169 kJ
  2. Step 1, 8-pole field at ωs/2 = 78.54 rad/s, slip 1 → 0: ½ × 0.5 × 78.54² = 1.542 kJ
  3. Step 2, switch to 4-pole: the rotor is at half speed, slip 0.5 → 0: ½Jωs²(0.5² − 0) = 1.542 kJ
  4. Total = 1.542 + 1.542 = 3.084 kJ, half the direct start; n equal steps cut it to 1/n

Answer: 3.08 kJ in two steps against 6.17 kJ direct

Chapter 6

Load equalization with a flywheel

Which syllabus covers thisAU not in syllabusVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 1KTU not in syllabus

Why smooth out a pulsating load?

Presses, punches, rolling mills and reciprocating compressors need a large torque for a short part of each cycle. The illustrative press here needs 110 N·m for 1 s in every 6 s, but only 30.8 N·m on average. A motor that follows every peak must deliver 2.2 times the rated torque of the book's 49.75 N·m motor, and its current pulses dip the supply voltage for other loads. Smoothing lets the motor work near the mean instead, so a smaller motor and a steadier supply current will do.

How does a flywheel share the peak?

When the load torque jumps, the motor's speed falls a little, and the flywheel gives up kinetic energy, ½J(ω1² − ω2²), to help carry the load. During the light part the motor speeds up again and refills the flywheel. With an 8 kg·m² flywheel and a motor whose slip at rated torque is 8 %, the motor's peak falls from 110 N·m to 53.9 N·m while the speed dips 8.7 %. Drag the flywheel inertia toward zero and the motor torque follows the load again.

Load equalization: a flywheel lets a drooping motor ride through a pulsating press or rolling-mill load with a smaller peak torque: interactive loads as you scroll

Why must the motor's speed droop for a flywheel to help?

A flywheel only releases energy when its speed falls. A synchronous motor runs at constant speed, so however big the flywheel, the motor must still supply every peak: Tmax stays at 110 N·m. A cage motor with 4 % slip helps, but less: the same 8 kg·m² flywheel gives a 74.3 N·m peak against 53.9 N·m at 8 % droop. A slip-ring motor with extra rotor resistance, switched in by a slip regulator, raises the droop when equalization is needed.

What formula gives the motor torque during the cycle?

With a linear droop Tm = (ω0 − ω)/k, the torque equation becomes first order: the motor torque moves toward the load torque with time constant τ = J·k. During a heavy part it rises from its starting value T0 toward TL, and afterwards it decays toward the light load. After a few cycles the start and end values repeat, which gives the periodic peak. Here k = 0.253 rad/s per N·m and J = 8.06 kg·m², so τ = 2.04 s.

Predict, then check

A press is driven by a synchronous motor through a heavy flywheel. As the flywheel is made heavier, what happens to the motor's peak torque?

Worked examples

Periodic peak torque with a flywheel · A coir-mill press: 80 N·m for 2 s, then 12 N·m for 6 s, repeating. A 6-pole, 50 Hz motor with droop k = 0.2 rad/s per N·m (Tm = (ω0 − ω)/k); total J = 15 kg·m² (illustrative)
  1. τ = J·k = 15 × 0.2 = 3 s; ω0 = 2π × 50 / 3 = 104.72 rad/s
  2. a = e^(−2/3) = 0.5134, b = e^(−6/3) = 0.1353
  3. Tmax = [80(1 − a) + a(1 − b)·12] / (1 − ab) = 47.56 N·m
  4. Tmin = 12 + (Tmax − 12)·b = 16.81 N·m; the mean load is 29 N·m
  5. Speed swings between ω0 − k·Tmin = 101.36 and ω0 − k·Tmax = 95.21 rad/s

Answer: Motor peak 47.6 N·m instead of 80 N·m; speed 95.2 to 101.4 rad/s

Sizing the flywheel for a target peak · The press of the interactive: 110 N·m for 1 s, 15 N·m for 5 s; motor droop 8 % (k = 0.08 × 157.08 / 49.75); limit the motor peak to 60 N·m
  1. k = 0.2526 rad/s per N·m
  2. Single-pulse formula (motor starts each pulse at 15 N·m): 60 = 110 − 95·e^(−1/τ), so τ = 1 / ln(95/50) = 1.558 s and J = τ/k = 6.17 kg·m²
  3. Periodic check with that J: the light part is too short for the torque to fall back to 15 N·m (it ends at 16.9 N·m), so the peak settles at 60.98 N·m, above the target
  4. Solving the periodic formula for Tmax = 60 N·m by bisection gives τ = 1.612 s, J = 6.38 kg·m² (motor 0.06 included)

Answer: J ≈ 6.4 kg·m² (the single-pulse estimate, 6.2 kg·m², falls short)

Energy the flywheel gives up in each stroke · The interactive's default: press load, total J = 8.06 kg·m², droop 8 %
  1. Periodic motor torque runs from Tmin = 18.34 to Tmax = 53.91 N·m (τ = 2.036 s)
  2. Speeds: ω0 − k·Tmin = 152.45 rad/s at the start of the stroke, ω0 − k·Tmax = 143.46 rad/s at its end
  3. Energy released = ½J(ω1² − ω2²) = 0.5 × 8.06 × (152.45² − 143.46²) = 10.716 kJ
  4. Check: ∫(TL − Tm)·ω dt over the 1 s stroke, summed numerically = 10.716 kJ
  5. A steel disc of radius 0.4 m giving the 8 kg·m² flywheel: m = 2J/r² = 100 kg

Answer: About 10.72 kJ per stroke from a 100 kg, 0.8 m disc

Chapter 7

Heating and cooling of motors and the classes of duty

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 2KTU not in syllabus

How does a motor's temperature rise with time?

Treat the motor as one body with heat capacity C and thermal resistance R to the coolant. Losses heat it, and the heat flow out grows with the rise θ, so θ climbs exponentially toward the steady rise θss = P·R with time constant τ = RC. It reaches 63.2 % of the way in τ, 95 % in 3τ and 99.3 % in 5τ. IEC 60034-1 finds τ from a cooling curve: 1.44 times the time to cool to half the full-load rise, so 45 min to half gives 64.9 min.

What limits how hot a motor may run?

The insulation. IEC 60034-1 (Table 7) limits the average winding rise, measured by the rise in winding resistance, for AC machines up to 200 kW to 80 K for thermal class 130 (B), 105 K for class 155 (F) and 125 K for class 180 (H), over a 40 °C coolant. So a class F winding may average 145 °C; hot spots run hotter than the average the resistance reads. The book's interactive rates its motor so that 100 % load running continuously settles exactly at the 105 K class F limit.

What are the duty types S1 to S10?

IEC 60034-1 lists ten: S1 continuous; S2 short-time; S3 intermittent periodic; S4 intermittent periodic with starting; S5 the same with electric braking; S6 continuous operation periodic; S7 continuous periodic with electric braking; S8 periodic with related load and speed changes; S9 non-periodic load and speed variations; S10 discrete constant loads and speeds. Periodic duties use a 10 min cycle with 15, 25, 40 or 60 % on time unless agreed otherwise. In the interactive, S3 at 40 % with 130 % load peaks at 98.7 K, under the 105 K limit.

Motor heating and cooling over a duty cycle: temperature rise for continuous, short-time and intermittent duty: interactive loads as you scroll

How much can a motor be overloaded for a short time?

If the motor starts cold and runs for less than about 3τ, it never reaches its steady rise, so a larger loss is allowed. With copper loss only, the load may rise by 1/√(1 − e^(−t/τ)): 1.38 × rated for 30 min with τ = 40 min. Constant losses raise it to 1.53 × with the interactive's loss split, because that part of the rated loss does not grow with load. Two more limits apply: the torque must stay below what the motor can develop, and a stopped self-ventilated motor cools slowly, so the rest must be long enough.

Predict, then check

Same motor, 130 % load for 4 min in every 10 min, fan on the shaft. Which runs hotter: S3 (stopped in between) or S6 (running at no load in between)?

Worked examples

Time constant from a heat run · A motor at constant load is heading for a final rise of 90 K and reaches 60 K after 60 min from cold (illustrative)
  1. θ = θss(1 − e^(−t/τ)): 60 = 90(1 − e^(−60/τ)), so e^(−60/τ) = 1/3
  2. τ = −60 / ln(1/3) = 54.61 min
  3. Time to reach 85 K: t = −τ·ln(1 − 85/90) = 54.61 × ln 18 = 157.9 min
  4. After 3τ = 164 min the rise is 95 % of 90 K = 85.5 K, close enough to call it settled

Answer: τ = 54.6 min; 85 K after about 158 min

Short-time (S2) rating · A 15 kW motor is rated S1 at the class F limit; heating τ = 50 min; constant losses are 0.6 of the copper loss at rated load (illustrative). It is to run S2 20 min from cold
  1. Loss at load x (per unit of rated loss) = (0.6 + x²)/1.6; the rise at the end must just reach the limit
  2. (0.6 + x²)/1.6 × (1 − e^(−20/50)) = 1, with 1 − e^(−0.4) = 0.3297
  3. x² = 1.6/0.3297 − 0.6 = 4.253, so x = 2.062
  4. S2 20 min rating = 15 × 2.062 = 30.9 kW (copper loss alone would allow 1.742 × = 26.1 kW)
  5. Check the torque too: the motor must develop that much torque without stalling

Answer: About 30.9 kW for 20 min (S2 20 min)

Intermittent periodic (S3) temperature · On load for 4 min, at rest for 6 min (S3 40 %); the on-load level alone would settle at 120 K; heating τ = 30 min, cooling τ at rest = 60 min (illustrative)
  1. e^(−4/30) = 0.8752, e^(−6/60) = 0.9048
  2. Periodic maximum = 120(1 − 0.8752) / (1 − 0.8752 × 0.9048) = 71.98 K
  3. Periodic minimum = 71.98 × 0.9048 = 65.13 K
  4. First cycle from cold reaches only 14.98 K; the geometric series of cycles builds up to 72 K
  5. Under the 105 K class F limit; a simple average, 120 × 0.4 = 48 K, would mislead because cooling at rest is slower

Answer: Swings between 65.1 and 72 K: within class F

Chapter 8

Choosing the motor rating: equivalent current, torque and power methods

Which syllabus covers thisAU EE3012 Unit IVTU not in syllabusSPPU 404191(B) Unit IMU EEC701 Module 2KTU not in syllabus

Why does the RMS torque decide the rating of a motor on a varying load?

Heating comes mostly from copper loss, which goes as current squared, and with constant flux current goes as torque. So a cycle heats the motor like a steady torque equal to the root-mean-square of the cycle. This holds when the cycle is short compared with the thermal time constant and cooling stays the same. The illustrative crane cycle averages 37.6 N·m, but its RMS is 50.9 N·m, just above the 49.75 N·m of a 7.5 kW motor. Sizing by the average would cook the motor.

Once T_rms is known, how is the motor picked?

Take the next standard size, then check the peak. IS 12615 lists 4-pole ratings such as 5.5, 7.5, 11, 15 and 18.5 kW. IEC 60034-1 guarantees a momentary excess torque of at least 60 % for 15 s, so the peak should stay under 1.6 × rated. For the press, T_rms = 60.5 N·m points to 11 kW (73 N·m), but its 140 N·m stroke is more than 1.6 × 73 = 117 N·m. The peak decides: 15 kW. Try editing a segment to see which check binds.

Sizing a motor for a fluctuating load cycle: RMS torque, the rating chosen and the peak-torque check: interactive loads as you scroll

When do the equivalent current and equivalent power methods work?

The current method is the most direct, since copper loss goes as I², but it needs the current over the cycle. For a DC motor with constant field, current is proportional to torque, so the torque and current methods agree. The power method assumes constant speed as well. In the crane cycle the creep segment carries 70 N·m at 20 % speed: lots of current, little power. So the power method reads 6.28 kW against T_rms × ω = 7.68 kW, and it under-sizes the motor.

How is a motor rated for intermittent duty?

If a load runs for a fraction D of a short cycle and the motor rests otherwise, copper loss alone would allow 1/√D times the continuous rating: 2 × at 25 %. Constant losses that stop with the motor raise this a little. A stopped self-ventilated motor cools slowly, which cuts it, and a 10 min cycle is not short against a 40 min τ. With the heating chapter's model, S3 at 40 % allows 135 % with a shaft fan and 173 % with a separate fan, against 158 % from 1/√D. The peak-torque check still applies.

Predict, then check

A load needs 100 N·m for 10 s and nothing for the next 30 s, repeating quickly. Is a motor rated 50 N·m good enough?

Worked examples

RMS torque for a machine-tool spindle · A Pune lathe spindle cycle at 1,440 rpm: 75 N·m for 4 s, 50 N·m for 25 s, 20 N·m for 10 s, 0 for 11 s (cooling assumed the same at rest; illustrative)
  1. Σ T²·t = 75² × 4 + 50² × 25 + 20² × 10 + 0 = 89000 N²·m²·s; cycle = 50 s
  2. T_rms = √(89000 / 50) = 42.19 N·m
  3. Power at 1,440 rpm (150.8 rad/s) = 42.19 × 150.8 = 6.36 kW
  4. Next IS 12615 size: 7.5 kW, rated torque 49.7 N·m
  5. Peak check: 75 / 49.7 = 1.51, within 1.6, so the 7.5 kW motor passes both checks (an 80 N·m peak would be 1.608 × and force 11 kW)

Answer: T_rms = 42.2 N·m: a 7.5 kW motor

Equivalent current of a DC drive · The book's DC motor (220 V, 50 A, K = 1.273 V·s/rad) on a cycle of 120 A for 5 s, 60 A for 20 s, 30 A for 15 s
  1. I_rms = √((120² × 5 + 60² × 20 + 30² × 15) / 40) = 62.75 A
  2. Equivalent torque = K × I_rms = 1.273 × 62.75 = 79.9 N·m
  3. The motor's rated 50 A is less than 62.7 A: it would overheat
  4. The 120 A peak is also 2.4 × rated: check it against the maker's commutation (overload) limit as well

Answer: I_rms = 62.7 A: the 50 A motor is too small

Where the power method goes wrong, and an intermittent rating · Part of the crane cycle at 1,440 rpm: hoist 75 N·m for 15 s at full speed, creep 70 N·m for 6 s at 20 % speed, rest 20 s, lower 25 N·m for 15 s at full speed; then a 7.5 kW motor on S3 25 % (illustrative)
  1. T_rms = √((75² × 15 + 70² × 6 + 25² × 15) / 56) = 46.89 N·m, so P = T_rms × ω = 7.07 kW
  2. Power method: the creep power is 70 × 0.2 × 150.8 = 2.11 kW, giving P_eq = 6.21 kW, an under-estimate
  3. S3 25 %, copper loss only: 7.5 / √0.25 = 15 kW; with constant losses half the copper loss: 7.5 × √(1.5/0.25 − 0.5) = 17.6 kW
  4. Check the torque: 2.35 × rated torque in every on period is close to the book motor's pull-out torque of 2.85 × rated: torque goes as V², so a 9 % voltage dip would stall it; here the torque, not the heat, limits the S3 rating

Answer: Size by T_rms (7.07 kW), not the power method (6.21 kW); S3 25 % is torque-limited, not heat-limited

Chapter 9

DC motor characteristics and braking: regenerative, dynamic and plugging

Which syllabus covers thisAU not in syllabusVTU BEE613D Module 3SPPU 404191(B) Unit IIMU EEC701 Module 4KTU PCEET403 Module 4

What does the speed-torque line of a separately excited DC motor look like?

A straight line. The back EMF Kω equals V − Ia·Ra and torque is K·Ia, so speed falls by Ra/K² for every newton-metre. The book's 220 V motor (illustrative: Ra 0.4 Ω, K 1.273 V·s/rad) runs at 1,650 rpm with no load and droops 10 % to 1,500 rpm at its rated 63.7 N·m. Lowering V shifts the line down in parallel, weakening the field raises it and steepens it, and extra armature resistance only steepens it. Carry the same line past zero torque and you are already braking.

What are the three ways to brake a DC motor electrically?

Make the current reverse while the motor keeps turning: torque then opposes motion (quadrant II). Regenerative: the source voltage drops below the back EMF and power flows back. Dynamic: the armature is switched onto a resistor Rb, and the motor works as a generator heating it. Plugging: the supply is reversed, so supply and back EMF push current together through a series resistor. Starting at 1,500 rpm with Rb = 2 Ω, the braking current is −83.3 A and the torque −106.1 N·m. The machine stops in 0.66 s against a 20 % friction load (illustrative).

Braking a DC motor: regenerative, dynamic (rheostatic) and plugging lines on the speed-torque plane: interactive loads as you scroll

How does regenerative braking return energy, and when is it possible?

The armature current reverses only when E exceeds the terminal voltage. Two ways get you there. A hoist lowering a load can drive the motor above its 1,650 rpm no-load speed at full voltage, or a converter can cut its voltage below E. In the interactive, the converter holds −75 A from 1,500 rpm: a constant −95.5 N·m that stops the drive in 0.29 s. Of the 2.47 kJ stored, 1.52 kJ goes back to the supply, 0.65 kJ heats Ra and the rest is friction. The source has to be able to accept power: a diode rectifier cannot.

How do dynamic braking and plugging compare?

Dynamic braking torque, −K²ω/(Ra + Rb), is proportional to speed, so it fades as the motor slows. With no friction the speed would only decay exponentially, with τ = J(Ra + Rb)/K² = 0.296 s for Rb = 2 Ω. Plugging stays strong down to standstill, but the supply keeps pushing. From 1,500 rpm through 4 Ω the supply adds 4.75 kJ, and 6.94 kJ of heat ends up in the resistors: 2.8 times the stored energy. The supply must be cut at zero speed, or the motor starts running backwards.

Predict, then check

A DC motor is braked dynamically through a fixed resistor from 1,500 rpm. At 750 rpm, how does its braking torque compare with the torque at the start?

Worked examples

Regenerative braking of a hoist lowering a load · The book's motor (220 V, Ra 0.4 Ω, K 1.273 V·s/rad) on full 220 V; an overhauling load drives it so that 40 A flows back into the supply (illustrative)
  1. Current reverses, so E = V + I·Ra = 220 + 40 × 0.4 = 236 V
  2. Speed ω = E/K = 236/1.273 = 185.35 rad/s = 1,770 rpm, above the 1,650 rpm no-load speed
  3. Braking torque = K·I = 1.273 × 40 = 50.93 N·m
  4. Mechanical power from the load = E·I = 9.44 kW; returned to the supply V·I = 8.8 kW; I²Ra = 640 W

Answer: 1,770 rpm, 50.9 N·m braking torque, 8.8 kW returned

Sizing a dynamic braking resistor · The book's motor running at 1,500 rpm (E = 200 V), J = 0.2 kg·m², no load torque; limit the braking current to 2 × rated = 100 A
  1. Ra + Rb = E/I = 200/100 = 2 Ω, so Rb = 2 − 0.4 = 1.6 Ω
  2. Initial braking torque = K·I = 1.273 × 100 = 127.3 N·m
  3. Time constant τ = J(Ra + Rb)/K² = 0.2 × 2/1.621 = 0.2467 s; ω = ω0·e^(−t/τ)
  4. Time to 10 % speed = τ·ln 10 = 0.568 s
  5. Stored energy ½Jω² = 2.467 kJ; share heating Rb = Rb/(Ra + Rb) = 80 %, i.e. 1.974 kJ

Answer: Rb = 1.6 Ω, 127 N·m at the start, 10 % speed after 0.57 s

Plugging: the resistor and the torque left at standstill · The same motor at 1,500 rpm (E = 200 V); supply reversed; braking current limited to 100 A; 20 % rated friction torque (12.7 N·m)
  1. Supply and EMF now add: R total = (V + E)/I = (220 + 200)/100 = 4.2 Ω, so external R = 3.8 Ω
  2. Torque at the start = −K × 100 = −127.3 N·m
  3. At standstill E = 0: I = 220/4.2 = 52.38 A and T = −66.7 N·m, still enough to drive the motor backwards, so a zero-speed switch must open the supply
  4. Stop time (La neglected): τ = J·R/K² = 0.518 s; ω(t) = (ω0 + b)e^(−t/τ) − b with b = V/K + TL·R/K² = 205.8 rad/s gives t = 0.294 s
  5. Energy: the supply delivers 4.78 kJ, and 6.98 kJ of heat goes into R

Answer: External R = 3.8 Ω; stop in 0.29 s; 7 kJ dumped as heat

Chapter 10

Controlled-rectifier-fed DC drives: single-phase and three-phase

Which syllabus covers thisAU EE3012 Unit IIVTU not in syllabusSPPU 404191(B) Unit IIMU EEC701 Module 4KTU PCEET403 Module 4

How does the firing angle set the armature voltage?

A thyristor bridge connects the armature to the supply from the firing angle α onwards. A fully controlled single-phase bridge, with the current flowing all the time, gives an average of 0.9·V·cos α. From a 250 V secondary (illustrative) that is 225.1 V at α = 0 and 112.5 V at 60°. A half-controlled (semi) bridge freewheels instead of going negative: (√2·V/π)(1 + cos α). A three-phase full bridge gives 1.35·VLL·cos α, which is 225.5 V from 167 V. The converter bridges themselves are covered in the Power Electronics book.

How does a rectifier-fed drive control speed?

Speed follows the armature voltage: ω = (Va − Ia·Ra)/K. Raising α lowers Va, and the whole speed-torque line moves down in parallel, so the speed stays stiff against load changes at every setting. In the interactive (single-phase full bridge, a 22 mH smoothing choke, rated torque), α = 60° gives Va = 112.5 V and 694 rpm. The armature current carries a 100 Hz ripple around its 50 A average. Torque follows the average current, and the ripple only adds heating.

A controlled rectifier driving a DC motor: firing angle, armature voltage and current waveforms and the speed-torque lines: interactive loads as you scroll

What happens when the firing angle passes 90°?

The average voltage turns negative while the current keeps its direction, so power flows from the DC side back to the AC supply: the bridge inverts. Only an active load can do this, because the motor must be driven backwards to make its EMF negative. A hoist lowering a load is the classic case (quadrant IV). At α = 130° and rated current, Va = −144.7 V and the hoist runs at −1,235 rpm. A semi-converter cannot invert. α must stay short of 180°: the outgoing thyristor needs a margin of reverse voltage to turn off.

Why use a three-phase bridge, and what does α do to the power factor?

A three-phase bridge gives six pulses per cycle (300 Hz ripple) instead of two (100 Hz), so the current ripple is far smaller for the same inductance. Its current stays continuous down to lighter loads too. With a smooth DC current, the supply current's fundamental lags the voltage by α in a full bridge and by α/2 in a semi bridge. At α = 90° the full bridge's displacement factor is cos 90° = 0, against 0.707 for the semi. Low speed on a full bridge means poor power factor.

Predict, then check

A single-phase fully controlled bridge feeds a DC motor with continuous armature current. The firing angle is set to 90°. What is the average armature voltage?

Worked examples

Firing angle for a speed · Single-phase full bridge, 250 V secondary; the book's motor at rated current 50 A (continuous) and 1,000 rpm
  1. E = K·ω = 1.273 × 104.72 = 133.33 V
  2. Va = E + Ia·Ra = 133.33 + 20 = 153.33 V
  3. cos α = Va/(0.9 × 250) = 153.33/225.08 = 0.6812
  4. α = 47.06°

Answer: α ≈ 47.1°

Lowering a hoist with a three-phase bridge · Three-phase full bridge, 167 V line; hoist load holds the book's motor at rated current while lowering at 800 rpm (illustrative)
  1. Speed is reversed: E = 1.273 × (−83.78) = −106.67 V
  2. Va = E + Ia·Ra = −106.67 + 20 = −86.67 V
  3. cos α = −86.67/225.53 = −0.3843, so α = 112.6°: the bridge inverts
  4. Power from the falling load E·I = 5.333 kW; armature loss 1 kW; returned to the AC supply 4.333 kW

Answer: α ≈ 112.6°, 4.33 kW returned to the supply

Semi versus full bridge at the same voltage · 250 V secondary; the book's motor at 30 A; compare a semi bridge at α = 90° with a full bridge at α = 60°
  1. Semi: Va = (√2 × 250/π)(1 + cos 90°) = 112.54 V; full: 0.9 × 250 × cos 60° = 112.54 V, the same
  2. Speed = (Va − 30 × 0.4)/K = 78.96 rad/s = 754 rpm in both cases
  3. Displacement factor: full cos 60° = 0.5; semi cos 45° = 0.707
  4. The semi bridge draws less reactive power but cannot reverse its voltage, so it cannot regenerate

Answer: Both 754 rpm; semi displacement factor 0.71 against 0.5

Chapter 11

Discontinuous conduction and the dual converter

Which syllabus covers thisAU EE3012 Unit IIVTU not in syllabusSPPU not in syllabusMU not in syllabusKTU not in syllabus

Why does the armature current become discontinuous at light load?

Thyristors cannot carry current backwards. At light load the average current is small, the ripple is larger than the average, and the current reaches zero at an extinction angle β before the next firing at α + 180°. While nothing conducts, the armature floats and its terminal voltage is the back EMF E, not the supply. The average voltage then depends on β and E as well as α, so the simple 0.9·V·cos α no longer holds and Va comes out higher.

What does discontinuous conduction do to the speed?

The speed rises above the straight line. Take a single-phase full bridge from 250 V at α = 60°, with 30 mH in the armature circuit (illustrative) and 20 % rated torque. The current stops at β = 207.7° and the motor runs at 1,389 rpm, not the 814 rpm the continuous line predicts. As load falls further, the speed climbs toward Vm/K = 2,652 rpm for α ≤ 90°, because a thyristor fired while the supply still rises conducts until E reaches the peak. The speed regulation becomes poor.

Discontinuous armature current: when the current falls to zero each cycle and the speed rises at light load: interactive loads as you scroll

Where is the boundary, and how do drives push it to lighter loads?

At the boundary the continuous current's minimum just touches zero. With only the motor's 8 mH, our single-phase drive is discontinuous below 114 N·m at α = 90°, which is above rated torque. A 22 mH smoothing choke brings that down to 30.4 N·m. A three-phase bridge, with six pulses, does better still. The current controller has to handle both regions, because the converter's gain falls sharply once the current is discontinuous.

What is a dual converter and why does circulating current help?

Two full bridges in antiparallel: bridge 1 carries positive armature current and bridge 2 negative, so the motor gets all four quadrants. They are fired with α1 + α2 = 180° so both give the same average voltage. Without circulating current only one bridge conducts, and reversal waits a dead time for the current to die. Both bridges are discontinuous near zero current, so the speed jumps around zero torque. With a reactor between them, a circulating current keeps both bridges conducting: the line stays straight and reversal is smooth.

Predict, then check

A rectifier-fed DC motor runs at light load with discontinuous armature current. Compared with the straight speed-torque line drawn for continuous current, its actual speed is:

Worked examples

Extinction angle and average current · Single-phase full bridge, 250 V (Vm = 353.6 V), α = 60°, total armature circuit 0.4 Ω and 30 mH, back EMF held at E = 150 V by the load
  1. X = ωL = 314.16 × 0.03 = 9.425 Ω, Z = 9.433 Ω, φ = 87.57°
  2. Vm·sin 60° = 306.2 V is above E, so conduction starts at α
  3. i(θ) = (Vm/Z)[sin(θ − φ) − sin(α − φ)e^(−(θ − α)/tan φ)] − (E/R)(1 − e^(−(θ − α)/tan φ))
  4. i returns to zero at β = 221.64° (bisection), before α + 180° = 240°: discontinuous
  5. Average current (integral of i over 180°) = 14.17 A, so T = K·Iavg = 18.05 N·m at 1,125 rpm
  6. Va = [Vm(cos α − cos β) + E(π − β + α)]/π = 155.67 V, against 112.54 V for continuous current

Answer: β ≈ 221.6°, Iavg ≈ 14.2 A

The continuous/discontinuous boundary at α = 90° · Same bridge and 30 mH circuit, α = 90°; at the boundary the continuous current's minimum, at the firing instant, is zero
  1. Periodicity with i(α) = 0 gives E_b = −R(Vm/Z)·sin(α − φ)·(1 + x)/(1 − x), x = e^(−π/tan φ) = 0.8752
  2. E_b = −0.4 × (353.6/9.433) × sin(2.43°) × 15.022 = −9.55 V
  3. Va = 0 at α = 90°, so Iavg = (0 − E_b)/R = 23.87 A and T = 30.4 N·m
  4. With only the motor's 8 mH the same boundary is at 113.5 N·m, above rated torque

Answer: Boundary ≈ 30.4 N·m (48 % of rated) at −72 rpm

A dual converter in circulating-current mode · Two single-phase full bridges, 250 V; α1 = 50°; the book's motor at +30 A (motoring) and −30 A (braking)
  1. α2 = 180° − 50° = 130°: bridge 1 gives 0.9 × 250 × cos 50° = 144.68 V, and bridge 2's −144.68 V is the same voltage seen from the other side
  2. +30 A from bridge 1: ω = (144.68 − 12)/1.273 = 104.21 rad/s = 995 rpm
  3. −30 A through bridge 2: ω = (144.68 + 12)/1.273 = 123.05 rad/s = 1,175 rpm, braking in quadrant II
  4. The instantaneous bridge voltages differ, so a reactor limits the circulating current that keeps both bridges conducting

Answer: 995 rpm motoring, 1,175 rpm braking, on one straight line

Chapter 12

Chopper-fed DC drives: time-ratio and current-limit control, two- and four-quadrant choppers

Which syllabus covers thisAU EE3012 Unit IIVTU BEE613D Module 3SPPU 404191(B) Unit IIIMU EEC701 Module 4KTU PCEET403 Module 4

How does time-ratio control set the armature voltage, and what sets the ripple?

A chopper switches the DC bus onto the armature for a fraction D of each period, so Va = D·V. Keeping the frequency fixed and varying the on-time is PWM; varying the frequency with a fixed on-time also works but makes filtering harder. On the motor's own 220 V as a bus, D = 0.6 gives 132 V and 840 rpm at rated load. The current ripples between two exponentials, 6.6 A peak to peak at 1 kHz with La = 8 mH: about V·D(1 − D)/(L·f), largest at D = 0.5.

What is current-limit control, and why is it used for starting?

The chopper turns off when the current reaches Iref + Δ and back on at Iref − Δ, so the current stays in a band whatever the back EMF. The motor then starts at constant torque. In the interactive start (90 A ± 5 A against a half-load conveyor, illustrative), the speed ramps at (K·Iref − TL)/J and reaches 1,200 rpm in 0.306 s. The switching frequency is not fixed. It is highest, V/(8ΔL) = 688 Hz, when E + Ra·I = V/2, and falls at both ends of the run.

Chopper-fed DC drive: time-ratio control and current-limit (hysteresis) control while starting a motor: interactive loads as you scroll

Which chopper gives which quadrants?

Class A (one switch and a freewheeling diode) gives only forward motoring. Class C adds a lower switch S2 and a diode D1 across the upper switch. S2 shorts the armature so the EMF builds up a negative current, and when S2 opens D1 pushes it into the bus: regenerative braking. Driven by an overhauling load at D = 0.6 and −50 A, the motor turns at 1,140 rpm and returns 6.6 kW. Class E, a full H-bridge, gives Va = (2D − 1)·V and all four quadrants.

How high should the chopping frequency be?

Higher frequency shrinks the ripple roughly in proportion: 13.7 A at 500 Hz, 6.87 A at 1 kHz and 1.72 A at 4 kHz for D = 0.5. That means less extra heating and torque pulsation, and in a class A chopper continuous current down to lighter loads. Switching losses grow with frequency, though, so the choice is a trade-off. A bipolar H-bridge swings ±V instead of V to 0, which doubles the ripple at the same frequency.

Predict, then check

A class A chopper on 220 V runs the book's motor at D = 0.5 against a constant load torque. D is raised to 0.6. By how much does the speed rise, roughly?

Worked examples

Duty ratio and exact ripple · Class A chopper, 220 V bus, 2 kHz; the book's motor at 50 A and 1,000 rpm; La = 8 mH, Ra = 0.4 Ω (τa = 20 ms)
  1. E = 1.273 × 104.72 = 133.33 V; Va = E + 20 = 153.33 V
  2. D = Va/V = 0.697; on-time 348.5 µs of each 500 µs period
  3. Exact ripple Δi = (V/R)(1 − e^(−DT/τ))(1 − e^(−(1−D)T/τ))/(1 − e^(−T/τ))
  4. Δi = 550 × 0.00528 = 2.904 A
  5. Linear estimate V·D(1 − D)/(L·f) = 2.904 A; current swings 48.55 to 51.45 A

Answer: D ≈ 0.697, Δi ≈ 2.9 A peak to peak

Class C regenerative braking · Class C chopper, 220 V bus; an overhauling load drives the book's motor at 1,200 rpm; required braking current 40 A
  1. E = 1.273 × 125.66 = 160 V
  2. The current flows into the bus, so Va = E − I·Ra = 160 − 16 = 144 V
  3. Fraction of time the terminal sits at V (D1 conducting) = 144/220 = 0.6545; S2 is on for 0.3455
  4. Power: mechanical in E·I = 6.4 kW, Ra loss 0.64 kW, into the bus Va·I = 5.76 kW

Answer: S2 duty ≈ 0.345, 5.76 kW returned

A current-limit start · Class A chopper, 220 V; band 80 A ± 4 A; half-load conveyor 31.8 N·m (passive); J = 0.2 kg·m²; target 1,200 rpm
  1. Torque in the band = K × 80 = 101.9 N·m; acceleration = (101.9 − 31.8)/0.2 = 350.1 rad/s²
  2. Time to 125.7 rad/s ≈ 0.359 s; allowing for the 2.9 ms initial current ramp, 0.361 s
  3. At E = 80 V (600 rpm): on-time = 2ΔL/(V − E − Ra·I) = 0.593 ms, off-time = 2ΔL/(E + Ra·I) = 0.571 ms
  4. Switching frequency = 1/(on + off) = 859 Hz, close to the maximum V/(8ΔL) = 859 Hz at E + Ra·I = 110 V

Answer: About 0.36 s to 1,200 rpm; switching near 859 Hz mid-start

Chapter 13

Transfer functions of the DC motor, load and converter

Which syllabus covers thisAU EE3012 Unit VVTU not in syllabusSPPU 404191(B) Unit IIIMU EEC701 Module 3KTU not in syllabus

What is the transfer function of a separately excited DC motor?

Two equations: La·di/dt = V − Ra·i − K·ω and J·dω/dt = K·i − TL. With TL = 0 they give a second-order system with two time constants: electrical τa = La/Ra and mechanical τm = J·Ra/K². For the book's 220 V motor with J = 0.2 kg·m², τa = 20 ms and τm = 49.3 ms, so ζ = ½√(τm/τa) = 0.785 and the speed overshoots only 1.86 %. The catch is the current: switching 220 V straight onto the motor at rest drives 370 A, 7.4 times rated, after 33.9 ms.

DC motor step response from its two time constants: armature and mechanical, overshoot and settling: interactive loads as you scroll

How do the load and a load-torque step enter the model?

The load adds its inertia to J, referred through any gearing, and its torque TL enters as a disturbance at the torque summing point. Viscous friction B adds a B·ω term and turns J·s into J·s + B. At constant armature voltage a step of rated torque, 63.7 N·m, makes the book's motor slow down by TL·Ra/K² = 15.7 rad/s, which is 150 rpm or 10 % of base speed, while the current rises to TL/K = 50 A. That droop is what the speed loop of chapter 15 removes.

What is the transfer function of a thyristor converter?

Over the useful range it is a gain plus a delay. With a cosine-wave firing circuit the average output is linear in the control voltage: the book's illustrative bridge gives Vd0 = 3√2 × 200/π = 270.1 V for 10 V of control, so Kc = 27 V/V. A six-pulse bridge at 50 Hz fires every 3.33 ms; a new command waits on average half of that, T = 1.67 ms. That dead time is modelled as a lag Kc/(1 + sT). At 300 rad/s the lag adds 26.6° of phase and the true dead time 28.6°: close enough for loop design.

Which feedback elements close the loops of a DC drive?

Speed comes from a DC tachogenerator (an illustrative 60 V per 1,000 rpm gives 90 V at base speed) or an incremental encoder. A 1,024-line encoder read on both edges of both channels gives 4,096 counts per revolution, 102,400 counts per second at 1,500 rpm; counted over 1 ms, one count is 14.6 rpm, so slow speeds need longer windows or pulse timing. Armature current is read by a Hall-effect sensor or a shunt with an isolated amplifier. Each sensor adds a small filter lag that joins the converter delay in the loop design.

Predict, then check

You couple a load that doubles the total inertia J of the drive. What happens to the speed response to a voltage step?

Worked examples

A machine-tool spindle drive: time constants and poles · The book's motor (Ra 0.4 Ω, La 8 mH, K 1.273 V·s/rad) on a Pune machine-tool spindle, total J = 0.35 kg·m² (illustrative)
  1. τa = La/Ra = 0.008/0.4 = 20 ms
  2. τm = J·Ra/K² = 0.35 × 0.4/1.6211 = 86.36 ms
  3. ζ = ½√(τm/τa) = ½√(4.318) = 1.039: above 1, so two real poles
  4. s = −1/(2τa) ± √(1/(4τa²) − 1/(τaτm)) = −25 ± √(625 − 579) = −18.22 and −31.78 1/s
  5. Time constants 1/|s|: 54.9 ms and 31.5 ms

Answer: τm = 86.4 ms, ζ = 1.04: no overshoot, poles at −18.2 and −31.8 1/s

Why a DC drive needs a current loop: the 220 V start · The book's motor with J = 0.2 kg·m² at rest; 220 V applied in one step, no current limit
  1. τm = 49.35 ms, τa = 20 ms, ζ = 0.785: σ = 1/(2τa) = 25 1/s, ωd = √(1/(τaτm) − σ²) = 19.7 rad/s
  2. Current I(s)/V(s) = (τm s/Ra)/(τmτa s² + τm s + 1) gives i(t) = (V/(La·ωd))·e^(−σt)·sin(ωd·t)
  3. Peak where tan(ωd·t) = ωd/σ: t = 33.9 ms
  4. i peak = 220/(0.008 × 19.7) × e^(−0.847) × sin(0.667) = 370.4 A (an RK4 run agrees)
  5. That is 7.4 × rated: commutator flashover and a tripped breaker, so the current must be controlled

Answer: About 370 A at 34 ms, 7.4 times rated

Converter gain and delay · Three-phase fully controlled bridge from a 200 V (line) transformer secondary at 50 Hz, control voltage 0 to ±10 V with a cosine-wave firing circuit (illustrative)
  1. Vd0 = 3√2 × VLL/π = 3 × 1.4142 × 200/3.1416 = 270.09 V
  2. Kc = Vd0/10 V = 27.01 V/V
  3. Six pulses per cycle: firing every 20/6 = 3.33 ms; mean wait half of that, T = 1.667 ms
  4. Model Kc·e^(−sT) ≈ Kc/(1 + sT); at 300 rad/s, ωT = 0.5: lag phase atan(0.5) = 26.6°, dead-time phase 28.6°

Answer: Gc(s) = 27/(1 + 0.00167 s); the lag is within 2.1° of the dead time near the current-loop crossover

Chapter 14

The inner current loop: PI design and current limiting

Which syllabus covers thisAU EE3012 Unit VVTU not in syllabusSPPU 404191(B) Unit IIIMU EEC701 Module 3KTU not in syllabus

Why does a DC drive have an inner current loop?

Torque is K times armature current, so a current loop is a torque controller. It also protects: chapter 13 showed 370 A when 220 V is switched onto the stopped motor, while the loop holds whatever the speed loop asks for, clamped at a limit of 100 A (2 × rated, the illustrative limit used in this book). Because it is fast, crossing over near 273 rad/s, the speed loop sees it as a simple lag, and it hides converter nonlinearities and supply dips. The back EMF changes slowly, so the current loop treats it as a disturbance.

How is the current PI tuned by the modulus optimum?

The plant is Kc/(1 + sT) × (1/Ra)/(1 + sτa). Choose the PI integral time Ti = τa = 20 ms, so its zero cancels the slow armature pole; an integrator and the 1.67 ms converter lag remain. Then pick Kp so the closed-loop gain stays flat for as long as possible: Kp = τa·Ra/(2·Kc·T) = 0.0889 V/A. The loop becomes 1/(2T²s² + 2Ts + 1) with ζ = 0.707: 4.32 % overshoot at 10.5 ms, 10-90 % rise in 5.06 ms, phase margin 65.5°.

Designing the inner current loop: a PI controller that cancels the armature time constant, and the current limit: interactive loads as you scroll

What happens when Kp or Ti is set wrongly?

With Ti = τa the loop stays second order and only Kp matters: ζ = 1/√(2m) for m times the modulus-optimum gain. Doubling Kp gives ζ = 0.5 and 16.3 % overshoot; halving it gives an overdamped, slower loop. A short Ti no longer cancels the armature pole and adds phase lag: Ti = 5 ms with the right Kp overshoots 36 %. A long Ti leaves a slow creeping tail at the end of every step. Ti is the more critical setting, so La and Ra are measured during commissioning.

How do the current limit and the converter voltage limit act?

The current reference is clamped at 100 A. The converter can only reach ±270 V, so at standstill di/dt cannot exceed 270/0.008 = 33,762 A/s and 100 A takes at least 2.96 ms. At 1,500 rpm the back EMF uses 200 V and the Ra drop 40 V, leaving 30 V: di/dt is then limited to 3,762 A/s. When the PI output hits its clamp the integrator must stop (anti-windup), or it winds up and causes a large overshoot later.

Predict, then check

The current PI is set to the modulus optimum (4.3 % overshoot). You double Kp and leave Ti = τa. What overshoot do you expect?

Worked examples

Modulus-optimum current PI for the book's drive · Ra 0.4 Ω, La 8 mH; converter Kc 27.01 V/V, lag T = 1.667 ms (six-pulse bridge, illustrative)
  1. Ti = τa = La/Ra = 20 ms
  2. Kp = τa·Ra/(2·Kc·T) = 0.02 × 0.4/(2 × 27.01 × 0.001667) = 0.0889 V/A
  3. Open loop after cancellation: 1/(2Ts(1 + Ts)); |L| = 1 at (ωcT)² = (√2 − 1)/2, ωcT = 0.4551, ωc = 273.1 rad/s
  4. Phase margin = 90° − atan(0.4551) = 65.53°
  5. Closed loop 1/(2T²s² + 2Ts + 1): ζ = 1/√2, overshoot e^(−π) = 4.32 %

Answer: Kp = 0.0889 V/A, Ti = 20 ms; ωc = 273 rad/s, phase margin 65.5°

The same motor on a single-phase bridge · A Kerala coir-mill press drive using the same motor on a single-phase full bridge from a 260 V secondary, control ±10 V (illustrative)
  1. Vd0 = 2√2 × 260/π = 234.1 V, so Kc = 23.41 V/V
  2. Two pulses per cycle: firing every 10 ms, mean delay T = 5 ms (three times the six-pulse value)
  3. Kp = 0.02 × 0.4/(2 × 23.41 × 0.005) = 0.0342 V/A, Ti = 20 ms
  4. Crossover ωc = 0.4551/T = 91 rad/s against 273 rad/s; peak time 2πT = 31.4 ms against 10.5 ms

Answer: Kp = 0.0342 V/A; the current loop is 3 times slower (91 rad/s), which also slows the speed loop built on it

Step size and the voltage limit · Modulus-optimum loop of example 1, motor at standstill (E = 0), current reference steps of 50 A and 100 A
  1. 50 A step: peak 50 × (1 + 0.0432) = 52.16 A at 2πT = 10.47 ms; 10-90 % rise 5.06 ms
  2. The PI output jumps by Kp·Δi at the step: converter command 0.0889 × 50 × 27.01 = 120 V
  3. 100 A step: command 240 V, still inside ±270.1 V, so the response is the same shape, doubled
  4. With Kp raised 20 %, the 100 A step asks for 288 V: the converter clamps, the rise is slower than linear and the integrator must be held (anti-windup)

Answer: Peak 52.2 A at 10.5 ms; the 100 A step just fits (240 V of 270 V)

Chapter 15

The outer speed loop: cascade control and P, PI and PID speed controllers

Which syllabus covers thisAU EE3012 Unit VVTU not in syllabusSPPU 404191(B) Unit IIIMU EEC701 Module 3KTU not in syllabus

What is cascade control of a DC drive?

Two loops, one inside the other. The outer speed controller compares the speed reference with the measured speed and outputs a current reference, clamped at the current limit; the inner current loop of chapter 14 makes the armature current follow it. Seen from outside, the closed current loop is roughly a lag of 2T = 3.33 ms; add an illustrative 5 ms speed-sensor filter and the small lags sum to Teq = 8.33 ms. In a big speed step the current sits at its limit, so the motor accelerates at maximum torque without ever exceeding it.

Cascade control of a DC drive: a speed step with the current held at its limit while the motor accelerates: interactive loads as you scroll

How is the speed PI tuned by the symmetric optimum?

The plant from current reference to speed is K/(Js) times the lag 1/(1 + sTeq): an integrator, so a modulus-optimum PI would leave load errors to creep away slowly. The symmetric optimum places the PI zero at 1/(4Teq) and the crossover at 1/(2Teq) = 60 rad/s, midway on a log scale between the PI zero and the lag corner, which maximises the phase margin: 36.9°. For the book's drive Kp = 9.42 A per rad/s and Ti = 33.3 ms. A step overshoots 43.4 %; a reference filter 1/(1 + 4Teq·s) cuts that to 8.1 %.

What happens during a large speed step?

The speed error is big, the speed PI saturates and the current reference sits at the limit, 100 A. The motor torque is then constant at K × 100 = 127.3 N·m and the speed ramps in a straight line at (K·Imax − TL)/J = 637 rad/s² with no load: 0 to 1,000 rpm in 0.164 s. The current PI then has to chase the back EMF, which rises as a ramp. Adding K·ω to the converter command (EMF feed-forward) keeps it on the limit. Without it the current settles 6.3 A short and the ramp is 6.3 % slower.

How do P, PI and PID speed controllers compare?

P control has no integrator, so under load it needs a standing error to produce the current: Δω = TL/(K·Kp). With Kp = 9.42 A per rad/s, a 60 % load leaves the book's motor 30.4 rpm slow, and rated load 50.7 rpm. PI removes the error completely; the integral term finds the needed current within a few Ti. Adding D on the measured speed makes the controller fight acceleration, so the dip after a load step shrinks, but it also amplifies encoder noise and pulls the loop off its symmetric optimum, so this book's drive stays with PI.

Predict, then check

A rated load torque is suddenly applied to the drive running at 1,000 rpm under the symmetric-optimum PI speed loop. After the transient, the speed is:

Worked examples

Symmetric-optimum speed PI for a port conveyor · The book's motor on a Chennai port conveyor, total J = 0.6 kg·m² (illustrative); current loop lag 2T = 3.33 ms, speed filter 5 ms
  1. Teq = 2T + Tw = 3.333 + 5 = 8.33 ms
  2. Ti = 4·Teq = 33.3 ms
  3. Kp = J/(2·K·Teq) = 0.6/(2 × 1.2732 × 0.00833) = 28.27 A per rad/s
  4. Crossover 1/(2Teq) = 60 rad/s and phase margin 36.9°, the same as for J = 0.2: Kp scales with J, the bandwidth does not

Answer: Kp = 28.3 A per rad/s, Ti = 33.3 ms (3 × the gain for J = 0.2)

Accelerating on the current limit · The book's motor (J = 0.2 kg·m²) with a friction-like load of 30 % rated torque during the start, current limit 100 A, speed step to 1,000 rpm
  1. Motor torque at the limit: K × 100 = 127.32 N·m; load 19.1 N·m
  2. α = (K·Imax − TL)/J = (127.32 − 19.1)/0.2 = 541.1 rad/s²
  3. 1,000 rpm = 104.72 rad/s, reached in 104.72/541.1 = 0.1935 s (an RK4 run agrees)
  4. Kinetic energy stored at 1,000 rpm: ½ × 0.2 × 104.72² = 1097 J

Answer: A straight-line ramp at 541 rad/s², about 194 ms to 1,000 rpm

Steady error of a P speed controller · P speed control with Kp = 9.42 A per rad/s (the symmetric-optimum gain without its integrator), steady load 40 N·m
  1. Current needed: TL/K = 40/1.2732 = 31.42 A
  2. Error that produces it: Δω = i/Kp = 31.42/9.425 = 3.333 rad/s = 31.8 rpm
  3. Doubling Kp halves the error, but the loop K·Kp/(Js(1 + sTeq)) goes from ζ = 0.707 to ζ = 0.5: 16.3 % overshoot
  4. A PI controller removes the error without that trade-off

Answer: 31.8 rpm below the reference; a PI controller brings it to zero

Chapter 16

Armature voltage control and field weakening: constant torque and constant power

Which syllabus covers thisAU EE3012 Unit VVTU BEE613D Module 3SPPU not in syllabusMU not in syllabusKTU not in syllabus

How is a DC motor run below and above base speed?

Below base speed the field is kept at rated and the armature voltage is raised with speed: rated current gives rated torque, 63.7 N·m for the book's motor, at any speed up to 1,500 rpm, and the power rises with speed. At base speed the armature voltage reaches 220 V. To go faster the field is weakened: K = (V − Ia·Ra)/ω, so at rated current K falls as 1/ω, the torque falls as 1/ω and the power stays at 200 V × 50 A = 10 kW. These are the constant-torque and constant-power regions.

Armature voltage control below base speed and field weakening above it: torque, power and current limits against speed: interactive loads as you scroll

How much field current does a given speed need?

With a linear field, If is proportional to K, so at rated current If = Ifr × base speed/speed exactly, with the Ra drop included. At 2,250 rpm the book's motor needs 0.667 A of its 1 A field and offers 42.4 N·m; at 3,000 rpm 0.5 A and 31.8 N·m, still 10 kW. A lighter load needs less current, so the field can stay stronger: the interactive's default constant-power load (8 kW) at 2,250 rpm runs on 0.681 A of field and 39.2 A of armature current.

What limits the field-weakening range?

Commutation: at high speed and weak field, armature reaction and the reactance voltage of the coils being commutated cause sparking, so makers cap the current above some speed. This book uses an illustrative cap of Ia·n constant above 3,000 rpm. Then mechanical strength: the armature and commutator have a top speed, here an illustrative 3,750 rpm, where the current limit is 40 A, K = 0.519, torque 20.8 N·m and power 8.16 kW.

Which loads suit field weakening, and why is field failure dangerous?

Constant-power loads suit it: winders, reels, a Pune machine-tool spindle taking light cuts at high speed. A fan does not: its torque rises with ω² while the available torque falls as 1/ω, so a fan that needs full torque at base speed cannot go faster at all. Losing the field is dangerous. At no load the speed is about V/K, so if the field current falls to 0.2 A the motor heads for 8,250 rpm. Under load the armature current shoots up instead. A field-failure relay trips the drive.

Predict, then check

The book's motor runs at 3,000 rpm (twice base speed) in field weakening, with rated armature current. What torque can it give?

Worked examples

Field and armature current for a constant-power load · The book's motor (220 V, Ra 0.4 Ω, K 1.273 at 1 A field) driving an 8 kW constant-power load at 2,700 rpm (illustrative)
  1. ω = 2,700 × 2π/60 = 282.74 rad/s; TL = 8,000/282.74 = 28.294 N·m
  2. V = Ia·Ra + K·ω with Ia = TL/K gives K²·ω − V·K + TL·Ra = 0
  3. K = (220 + √(220² − 4 × 282.74 × 28.294 × 0.4))/(2 × 282.74) = 0.7227 V·s/rad (the larger root: weaker current)
  4. Ia = TL/K = 39.15 A (under 50 A); If = 1 A × 0.7227/1.2732 = 0.568 A
  5. Check: (220 − 39.15 × 0.4)/0.7227 = 282.74 rad/s

Answer: Va = 220 V, If = 0.568 A, Ia = 39.2 A

Top speed for a constant-torque load · The book's motor driving a constant 40 N·m load; armature current limited to 50 A, field weakening allowed up to 3,000 rpm
  1. Above base speed V = 220 V. The highest speed uses the full 50 A, so K = TL/Ia = 40/50 = 0.8 V·s/rad
  2. ω = (V − Ia·Ra)/K = (220 − 20)/0.8 = 250 rad/s = 2,387 rpm
  3. Field current If = 1 A × 0.8/1.2732 = 0.628 A
  4. Power 40 × 250 = 10,000 W = rated developed power; 2,387 rpm is below the 3,000 rpm commutation limit

Answer: 2,387 rpm with If = 0.63 A; any faster would need more than 50 A

How far can a fan go above base speed? · A cement-plant fan in Ariyalur (illustrative) on the book's motor, needing 50 % of rated torque at 1,500 rpm, with T ∝ n²
  1. Fan torque: 0.5 × 63.66 × (ω/ωb)² N·m; available at rated current above base: 10,000/ω N·m
  2. Equal when 0.5 × Tr × ω²/ωb² = Tr × ωb/ω, so (ω/ωb)³ = 2 and ω = 1.26 × ωb (bisection agrees)
  3. n = 1,500 × ∛2 = 1,890 rpm, K = 200/197.9 = 1.011, If = 0.794 A
  4. A fan needing full torque at base speed gives (ω/ωb)³ = 1: no field-weakening range at all

Answer: About 1,890 rpm (1.26 × base); fans run in the constant-torque region

Chapter 17

Stator voltage control and the energy-efficient induction motor drive

Which syllabus covers thisAU EE3012 Unit IIIVTU not in syllabusSPPU not in syllabusMU EEC701 Module 5KTU PCEET403 Module 4

How does lowering the stator voltage slow an induction motor?

Torque at any slip goes as V², while the slip of peak torque stays put. Three pairs of back-to-back thyristors in the supply lines, the same AC voltage controller a soft starter uses, chop the voltage down and the torque curve shrinks. The load curve now crosses it at a larger slip, so the motor runs slower. On the book's 7.5 kW motor driving a fan sized for rated torque at rated speed, 70 % voltage gives 1,370 rpm, a line current of 17.5 A and an efficiency of 82.2 %. At full voltage those are 1,440 rpm, 13.6 A and 89.6 %.

Stator voltage control of an induction motor driving a fan: speed range, rotor loss and why it suits fans, not constant torque: interactive loads as you scroll

Why does stator voltage control suit fans but not constant-torque loads?

At the running point the motor torque equals the load torque, and Pag = T·ωs. So the rotor copper loss is s·ωs·TL whatever the motor. With a fan, TL falls as (1 − s)², so the loss s(1 − s)² is largest at s = 1/3 and equals 4/27 of TL(ωs)·ωs. On the book's fan that is 1,257 W, 4 times the rated 315 W. With constant torque the loss grows in step with s: rated torque at 60 % voltage runs at 1,194 rpm and puts 1,594 W into the rotor. Below 59 % voltage the motor stalls.

How can lowering the voltage save energy at light load?

At light load a motor carries its full core loss and magnetising current for very little output. Lowering the voltage cuts the core loss (it goes as V²) and the magnetising current, while the rotor current rises slightly to keep the torque. Total loss has a minimum. The book's motor at 25 % of rated torque, with an assumed core loss of 1.5 % of rated input, loses 241 W at 415 V and 179 W at 280 V, the best voltage. Over an assumed 6,000 hours a year at ₹8/kWh that saves ₹2,992. At 50 % load the best voltage is 396 V and saves only 2 W.

What are the drawbacks of the thyristor voltage controller?

Phase-angle control chops the current, so the motor gets harmonic currents that heat it further, and the supply sees a lagging power factor that worsens as the firing is delayed. The speed range is narrow and depends on the load. A cage motor meant for this duty needs a high-resistance rotor and is derated, because of the large rotor loss at medium slip. Most new fan and pump installations use V/f drives (chapter 18). Where the controller survives is as a soft starter, and as a light-load energy saver on motors that run long hours far below rating.

Predict, then check

A fan motor is slowed by lowering its stator voltage. At what slip is its rotor copper loss largest?

Worked examples

A fan at 70 % voltage · The book's 7.5 kW, 415 V, 4-pole motor (R1 0.8, X1 1.4, R2′ 0.75, X2′ 1.4, Xm 40 Ω) driving a fan that takes rated torque 49.75 N·m at rated speed 1,439.6 rpm; supply cut to 70 % (290.5 V line); core loss 1.5 % of rated input at 415 V (illustrative)
  1. Fan torque: TL = 49.75 × (n/1,439.6)²; motor torque from the equivalent circuit at 290.5 V
  2. Solve Tm(s) = TL(s) by bisection: s = 0.0864, n = 1,370 rpm, T = 45.08 N·m
  3. Air-gap power Pag = T·ωs = 45.08 × 157.08 = 7,081 W
  4. Rotor loss = s·Pag = 0.0864 × 7,081 = 612 W (rated 315 W); stator loss 730 W; core loss 61 W
  5. Output = (1 − s)Pag = 6,470 W; efficiency = 6,470/(7,811 + 61) = 82.2 %

Answer: 1,370 rpm, 17.5 A, rotor loss 612 W, efficiency 82.2 %

Slowing an ID fan: voltage control against a V/f drive · An induced-draught fan at a cement plant (illustrative): 4-pole, 50 Hz motor, the fan takes 190 N·m at 1,480 rpm; wanted speed 1,000 rpm. With V/f, assume the full-load slip of 20 rpm scales with torque
  1. Fan torque at 1,000 rpm: 190 × (1,000/1,480)² = 86.74 N·m; shaft power = 9.08 kW
  2. Voltage control: synchronous speed stays 1,500 rpm, s = (1,500 − 1,000)/1,500 = 0.3333
  3. Pag = T·ωs = 86.74 × 157.08 = 13.625 kW; rotor loss = s·Pag = 4.542 kW, half the shaft power
  4. V/f: slip ≈ 20 × 86.74/190 = 9.13 rpm, so ns = 1,009.1 rpm; rotor loss = T × slip speed = 86.74 × 9.13 × π/30 = 83 W
  5. Worst case under voltage control, at s = 1/3: 4/27 × 190 × (1,500/1,480)² × 157.08 = 4.54 kW in the rotor

Answer: Voltage control dumps 4.54 kW in the rotor at 1,000 rpm, V/f only 83 W

Energy saving by voltage reduction at light load · The book's motor at a constant 25 % of rated torque (12.44 N·m), core loss 1.5 % of rated input at 415 V (123.7 W, ∝ V²); assumed 6,000 h a year at ₹8/kWh
  1. At 415 V: s = 0.0093, total loss (stator + rotor + core) = 241.4 W
  2. Golden-section search on total loss over V: best V = 279.7 V (67.4 %); a 0.1 V grid agrees
  3. At 279.7 V: s = 0.021, total loss = 179.1 W (core loss falls to 56.2 W)
  4. Saving = 62.3 W × 6,000 h = 374 kWh a year = ₹2,992 at ₹8/kWh

Answer: Run at about 280 V: loss falls from 241 W to 179 W, about ₹2,992 a year

Chapter 18

V/f control: constant air-gap flux, low-speed boost and operation above base speed

Which syllabus covers thisAU EE3012 Unit IIIVTU BEE613D Module 4SPPU not in syllabusMU EEC701 Module 5KTU PCEET403 Module 4

Why keep V/f constant when you lower the frequency?

The air-gap flux goes as E/f, where E is the air-gap EMF. Hold the flux at rated and the motor gives rated torque at rated current at any speed, with the torque-speed curve simply shifted down. Lowering f alone would push the flux up and saturate the iron, so the voltage is cut in proportion. A plain V/f law falls short at low speed, because the stator resistance drop becomes a big share of the small voltage. At 10 Hz (83 V) and rated torque, the book's motor has only 77 % flux. Its pull-out torque is 59.4 N·m against 141.6 N·m at 50 Hz, and it runs at 196 rpm.

V/f control: torque-speed curves at different frequencies, with and without low-speed voltage boost, and field weakening above base: interactive loads as you scroll

What does IR boost do, and why is a fixed boost not enough?

Boost adds a voltage at low frequency to make up the stator drop: the law starts at Vb at 0 Hz instead of 0 V. On the book's motor at rated torque, a boost of 16.3 V brings the flux to exactly 100 % at 10 Hz, and 16.6 V does it at 5 Hz. With 16 V the 10 Hz pull-out torque rises from 59.4 to 79.2 N·m. A fixed boost is right at one load only: lightly loaded, the motor is over-fluxed and draws extra magnetising current. That is why drives offer automatic boost, which raises the voltage with the measured current.

What happens above base speed?

The inverter cannot give more than rated voltage, so above 50 Hz V stays at 415 V and the flux falls as 1/f. This is the field-weakening region. Pull-out torque falls roughly as 1/f²: 141.6 N·m at 50 Hz, 102.9 at 60 Hz and 68.9 at 75 Hz. The pure 1/f² law would give 62.9 at 75 Hz; the real figure is a little higher because R1 matters less at high frequency. At rated current the torque falls about as 1/f, which gives constant power. Rated torque at 75 Hz would need 20.2 A, 1.5 times rated, so it cannot be carried for long. Rated power is typically available only up to about 130-150 % of nameplate speed.

How do V/f drives start softly and hold speed under load?

At rated flux the slip speed in rpm depends only on torque: rated torque costs 60 rpm at 50 Hz and 61 rpm at 10 Hz. Slip compensation estimates the torque from the current and raises the frequency by that slip, holding the speed without a sensor. Starting is a frequency ramp from a few hertz, so the motor always runs near its own synchronous speed, at low slip and near rated current. A direct-on-line start of the same motor draws 76.2 A, 5.7 times rated. Constant torque below base and constant power above it are the drive's two operating regions.

Predict, then check

A motor runs on a plain V/f law (no boost). At 10 Hz, how does its pull-out torque compare with that at 50 Hz?

Worked examples

Plain V/f at 20 Hz · The book's 7.5 kW motor on a V/f law without boost; constant load at rated torque 49.75 N·m
  1. V = 415 × 20/50 = 166 V line; synchronous speed = 120 × 20/4 = 600 rpm; reactances × 0.4
  2. Slip for 49.75 N·m (bisection on the circuit): s = 0.1166, n = 600 × (1 − s) = 530 rpm
  3. Air-gap EMF E = I2′·|R2′/s + jX2′| gives E/f = 93 % of rated
  4. Pull-out torque (Thevenin) = 97 N·m; current = 14.13 A

Answer: 530 rpm, flux 93 %, Tmax 97 N·m, 14.1 A

Boost for rated flux at 5 Hz · The same motor at 5 Hz carrying rated torque; find the 0 Hz boost Vb that gives rated air-gap flux
  1. No boost: V = 41.5 V, Tmax = 31.8 N·m, below the 49.75 N·m load: the motor stalls
  2. Flux rises with Vb, so bisect on Vb for E/f = rated (E from the circuit at the slip that carries 49.75 N·m)
  3. Vb = 16.64 V, so V(5 Hz) = 16.64 + (415 − 16.64) × 0.1 = 56.5 V
  4. Pull-out torque with this boost = 58.9 N·m: the load now runs, at 90 rpm

Answer: Vb ≈ 16.6 V (56.5 V at 5 Hz instead of 41.5 V)

A constant-power spindle above base speed · A machine-tool spindle in Pune (illustrative) driven by the book's motor needs 7.5 kW at 2,000 rpm; V/f with V held at 415 V above 50 Hz
  1. Torque = 7,500/(2,000 × π/30) = 35.81 N·m
  2. Bisect on f for n = 2,000 rpm at that torque: f = 69.53 Hz (ns = 2,086 rpm, s = 0.0412)
  3. Current = 12.99 A against 13.42 A rated
  4. Pull-out torque at 69.5 Hz = 79 N·m, 2.21 times the load

Answer: f ≈ 69.5 Hz, 13 A (97 % of rated current)

Chapter 19

VSI and CSI drives, closed-loop slip control and braking of induction motors

Which syllabus covers thisAU EE3012 Unit IIIVTU not in syllabusSPPU 404191(B) Unit IVMU EEC701 Module 5KTU not in syllabus

What is the difference between a VSI drive and a CSI drive?

A voltage source inverter has a large capacitor in its DC link. A 415 V diode bridge charges it to about 560 V, and the inverter chops that into six-step or PWM voltages, so the motor current follows from the voltage. A current source inverter has a large inductor instead and steers a nearly constant link current between the phases, so the voltage follows from the current. The CSI shrugs off a short circuit and can regenerate simply by reversing the link voltage with a controlled rectifier, because its link current never reverses. A VSI's link current does reverse when braking, so it needs a braking resistor or an active front end.

How does closed-loop slip regulation work?

At constant flux and small slip, torque is proportional to the slip frequency, the rotor's electrical frequency. A speed controller therefore outputs a slip-frequency command, clamped to a safe maximum. The drive adds it to the measured rotor frequency to get the inverter frequency, and takes the voltage from the V/f law. On the book's motor, rated torque needs 2.01 Hz of slip and 4 Hz gives 87.1 N·m. Pull-out comes at 13.1 Hz, so a clamp near 4 Hz limits the torque, and with it the current, during fast changes. A negative slip command brakes the motor, so all four quadrants come from one loop.

How do regenerative braking, plugging and DC injection compare?

Stopping the book's motor with J = 0.3 kg·m² from 1,500 rpm, where 3.7 kJ is stored: a 20 Hz/s frequency ramp stops it in 2.46 s and returns 3.26 kJ to the DC link. Plugging stops it in 0.84 s but puts 11 kJ into the rotor, three times the stored energy, and draws 80 A. DC injection at 15 A turns the stored energy into rotor heat. Its torque peaks at 55 N·m near 27 rpm and is weak at high speed, so it takes 11.8 s.

Braking an induction motor: regenerative braking by lowering the frequency, plugging and DC injection, compared in time and energy: interactive loads as you scroll

Where does regenerated energy go in a VSI drive?

Back into the DC link capacitor, whose voltage rises. A diode front end cannot pass power back to the mains, so a braking chopper switches a resistor across the link above a threshold voltage. That is dynamic braking, and it turns the energy into heat. A regenerative drive with an active front end instead feeds the energy back to the supply. Ramping the book's motor with J = 0.3 kg·m² down at 20 Hz/s needs about 18.8 N·m, or 2.96 kW at the start. With an illustrative 700 V chopper threshold, the resistor must be at most 165 Ω.

Predict, then check

An unloaded motor running at synchronous speed is stopped by plugging (two phases swapped). How much energy does its rotor absorb compared with the kinetic energy stored?

Worked examples

Plugging a high-inertia load · The book's 4-pole, 50 Hz motor with total J = 0.5 kg·m² (illustrative), unloaded at 1,500 rpm, stopped by plugging; losses other than rotor copper loss ignored for the energy count
  1. ωs = 2π × 50/2 = 157.08 rad/s; stored energy = ½ × 0.5 × 157.08² = 6.169 kJ
  2. Plugging: slip falls from 2 to 1, rotor energy = ½Jωs²(2² − 1²) = 18.506 kJ = 3 × stored
  3. For comparison, a direct-on-line start from rest (s from 1 to 0) puts ½Jωs² = 6.169 kJ into the rotor
  4. So one plug-stop heats the rotor as much as three starts

Answer: 18.51 kJ into the rotor, three times the 6.17 kJ stored

Sizing a braking resistor for a ramp stop · The book's motor, total J = 0.3 kg·m², stopped by ramping the frequency from 50 Hz at 20 Hz/s; diode front end; braking chopper switches at 700 V DC (illustrative)
  1. Synchronous speed falls at 2π × 20/2 = 62.83 rad/s², so the braking torque ≈ J·α = 0.3 × 62.83 = 18.85 N·m
  2. Peak braking power, at the start: 18.85 × 157.08 = 2,961 W
  3. Resistor that absorbs it at 700 V: R ≤ 700²/2,961 = 165 Ω
  4. Energy over the 2.5 s ramp ≈ ½ × 2,961 × 2.5 = 3.7 kJ, the stored energy (minus the motor's own losses)

Answer: About 3 kW peak, a resistor of 165 Ω or less

DC injection braking torque · The book's motor (Lm = 127.3 mH, Lr = 131.8 mH, R2′ = 0.75 Ω, 2 pole pairs) with 20 A DC through two terminals in series; J = 0.3 kg·m²
  1. Equivalent AC current I1 = √(2/3) × 20 = 16.33 A
  2. Peak torque 3pI1²Lm²/(2Lr) = 98.4 N·m at ωsl = R2′/Lr, i.e. rotor speed 27.2 rpm
  3. At 1,500 rpm: T = 3.56 N·m, braking power 560 W, below the ceiling 2·Idc²·R2′ = 600 W
  4. Slowing from 1,500 to 750 rpm (RK4 on J dω/dt = −T): 4.96 s; the ceiling alone would suggest 4.63 s

Answer: Peak 98.4 N·m at 27 rpm; only 3.6 N·m at 1,500 rpm

Chapter 20

Rotor resistance control and slip power recovery

Which syllabus covers thisAU not in syllabusVTU not in syllabusSPPU 404191(B) Unit IVMU not in syllabusKTU not in syllabus

How does rotor resistance control work, and what does it cost?

A slip-ring motor brings its rotor circuit out through brushes, so resistors can be added. Torque depends on R2′/s, so at the same torque the slip grows in step with the total rotor resistance, and the pull-out torque stays put. On the book's motor made wound-rotor, at rated torque, 4 Ω of external resistance (referred to the stator) drops the speed to 1,118 rpm. The whole slip power, 1.99 kW, is burnt in the resistors and rotor, and efficiency falls to 70.6 %. The extra resistance does give high starting torque at low current, which is why cranes and hoists used it.

Rotor resistance control against slip power recovery: where the slip power goes and the efficiency at reduced speed: interactive loads as you scroll

How does a static Kramer drive recover the slip power?

The rotor feeds a diode bridge. Its DC goes through a smoothing reactor to a thyristor inverter firing at α above 90°, and a transformer of ratio a returns the power to the mains. At no load the rectified rotor EMF, 1.35·s·E2, just balances the inverter's back-voltage, 1.35·a·E2·(−cos α), so s0 = −a·cos α. With an illustrative a = 0.5 and α = 125°, the no-load speed is 1,070 rpm and the motor runs at 988 rpm at rated torque. Of the 2.67 kW slip power, 2.35 kW returns to the supply: efficiency is 87.3 % against 62.4 % with resistors at the same speed.

Why is the converter small, and what are the catches?

The converter only handles the slip power, so a drive for a narrow speed range needs a converter far smaller than the motor. Doubly-fed wind generators use the same idea: typically 25-30 % of the power through the converter, over about ±30 % speed. The catches start with standstill, where the rotor voltage is highest, so the drive starts on resistors and switches the converter in near its lowest speed. A line-commutated inverter also draws lagging reactive power that grows as α nears 180°, so the overall power factor is poor at low speed. And at fixed torque the rotor current, 11.8 A here, stays the same at every speed, so the motor runs no cooler at low speed.

How can a slip-ring motor run above synchronous speed?

A diode bridge passes power only out of the rotor, so a static Kramer drive runs only below synchronous speed. Replace it with a converter that passes power both ways (two back-to-back thyristor bridges, a cycloconverter, or today two PWM converters) and you get a Scherbius drive. It can feed power into the rotor as well as take it out, so the machine runs sub- and super-synchronous, motoring or generating. The rotor converter can also supply reactive power, which improves the stator power factor. The doubly-fed induction generator of a wind turbine is this machine.

Predict, then check

A Kramer drive carries a constant load torque. Its speed is lowered from 1,440 rpm to 1,000 rpm by raising α. What happens to the rotor current?

Worked examples

Rotor resistance for 1,000 rpm · The book's motor as a wound-rotor machine (R2′ = 0.75 Ω referred) at rated torque 49.75 N·m; rated slip 0.04025; wanted speed 1,000 rpm
  1. Wanted slip s = (1,500 − 1,000)/1,500 = 0.3333
  2. Same torque ⇒ same R2′/s: R_total = 0.75 × 0.3333/0.04025 = 6.211 Ω, so Rext = 5.461 Ω (referred)
  3. Pag = T·ωs = 7,815 W; slip power burnt = s·Pag = 2,605 W
  4. Output = 5,210 W, input = 8,247 W, efficiency = 63.2 %

Answer: Rext ≈ 5.46 Ω; 2.6 kW wasted, efficiency 63.2 %

Firing angle for a no-load speed · Static Kramer drive on the same motor; rotor standstill line EMF E2 = √3 × Vth = 400.9 V (unity turns ratio, illustrative); transformer ratio a = 0.5; wanted no-load speed 1,200 rpm
  1. s0 = (1,500 − 1,200)/1,500 = 0.2
  2. s0 = −a·cos α ⇒ cos α = −0.2/0.5 = −0.4, α = 113.6°
  3. Check: rotor bridge DC = 1.35 × 0.2 × 400.9 = 108.3 V
  4. Inverter DC = 1.35 × 0.5 × 400.9 × cos 113.6° = −108.3 V: equal and opposite, so no current flows

Answer: α ≈ 113.6°

What recovery saves at 1,000 rpm · The same motor at rated torque and 1,000 rpm for an assumed 5,000 h a year at ₹8/kWh: rotor resistors against a static Kramer drive with a = 0.5 (converter and transformer losses neglected)
  1. Resistors (Example 1): input 8,247 W for 5,210 W out
  2. Kramer: back-EMF solved for s = 1/3 at rated torque gives α = 123.9°; rotor loss 315 W, returned 2,290 W
  3. Net input = 8,247 − 2,290 = 5,957 W, efficiency 87.5 %
  4. Saving = 2,290 W × 5,000 h = 11,451 kWh = ₹91,612 a year

Answer: About 2.29 kW less input, roughly ₹91,612 a year at the assumed tariff

Chapter 21

The d-q model: Clarke and Park transforms

Which syllabus covers thisAU not in syllabusVTU not in syllabusSPPU not in syllabusMU EEC701 Module 6KTU not in syllabus

What does the Clarke transform do to three phase currents?

With no neutral, ia + ib + ic = 0, so three currents carry only two independent numbers. The Clarke transform packs them into one space vector with components iα and iβ on two fixed, perpendicular axes. With the 2/3 scaling used in this book the vector's length equals the phase peak: the book's 7.5 kW motor at rated current (13.42 A rms) gives a vector 18.98 A long, turning at 314 rad/s for 50 Hz. Edith Clarke published these methods in 1937 and 1938.

What does the Park transform add, and why does it help control?

Park projects the space vector onto d and q axes that rotate. Pick the frame speed and the picture changes. In the stationary frame, d and q are just α and β, 50 Hz sinusoids. In a frame turning with the supply and aligned to the voltage, the rated current becomes two constants: id = 16.23 A (in phase with V) and iq = −9.85 A (the lagging, reactive part). In a frame on the rotor, they turn slowly at the slip frequency, 2.01 Hz. Constants are what PI controllers regulate well. Robert Park published the transform in 1929.

Clarke and Park transforms: three phase currents become one rotating vector, then two steady numbers in a rotating frame: interactive loads as you scroll

What does the induction motor look like in d-q form?

In a frame turning at ωk, the stator voltage is Rs·is + dψs/dt + jωk·ψs, and the shorted rotor gives 0 = Rr·ir + dψr/dt + j(ωk − ωr)·ψr. Fluxes are ψs = Ls·is + Lm·ir and ψr = Lm·is + Lr·ir, and torque is 1.5·p times the cross product of ψs and is. From the book motor's reactances: Lm = 0.1273 H, Ls = Lr = 0.1318 H, leakage factor σ = 0.0665, rotor time constant τr = 0.176 s. In steady state this gives 49.75 N·m at rated slip, exactly the equivalent-circuit torque.

Why does a factor 1.5 appear, and what do unbalance and harmonics look like?

Amplitude-invariant scaling keeps lengths equal to phase peaks but not power: p = va·ia + vb·ib + vc·ic = 1.5(vd·id + vq·iq). For the rated motor, 1.5 × 338.8 V × 16.23 A = 8.25 kW, the input power. The power-invariant scaling √(2/3) removes the 1.5 but changes the lengths. Distortion shows up as ripple in the synchronous frame. An unbalance is a negative-sequence part, so it ripples at 2f. A 5th harmonic turns backwards at 5f, so it ripples at 6f.

Predict, then check

The book's motor runs at rated slip on 50 Hz. You view its balanced stator currents in a d-q frame fixed to the rotor. What do id and iq look like?

Worked examples

Clarke and Park by hand · Instantaneous phase currents ia = 10 A, ib = −2 A, ic = −8 A; a dq frame at θ = 30°
  1. iα = (2/3)(10 + 1 + 4) = 10 A; iβ = (−2 + 8)/√3 = 3.464 A
  2. |i| = √(10² + 3.464²) = 10.583 A at 19.11° from the a axis
  3. Back: ib = −iα/2 + (√3/2)iβ = −5 + 3 = −2 A, ic = −5 − 3 = −8 A
  4. id = iα cos 30° + iβ sin 30° = 8.660 + 1.732 = 10.392 A
  5. iq = −iα sin 30° + iβ cos 30° = −5 + 3 = −2 A; |idq| = 10.583 A, the same length

Answer: iα = 10 A, iβ = 3.46 A; id = 10.39 A, iq = −2 A

The rated motor in the synchronous frame · The book's 7.5 kW, 415 V motor at rated load: 13.42 A rms, pf 0.855 lagging; d axis on the supply-voltage vector
  1. Phase voltage peak = 415/√3 × √2 = 338.8 V; current peak = 13.42 × √2 = 18.98 A
  2. φ = acos 0.855 = 31.25°; id = 18.98 × 0.855 = 16.23 A, iq = −18.98 × sin φ = −9.85 A
  3. P = 1.5 × vd × id = 1.5 × 338.8 × 16.23 = 8247 W
  4. Check: 3 × V × I × pf = 3 × 239.6 × 13.42 × 0.855 = 8247 W; shaft output 7,500 W, efficiency 90.9 %
  5. Q = −1.5 × vd × iq = 5004 var (the magnetising and leakage reactive power)

Answer: id = 16.23 A, iq = −9.85 A, both constant; P = 8.25 kW

Inductances and frame speeds of the book's motor · X1 = X2′ = 1.4 Ω, Xm = 40 Ω, R1 = 0.8 Ω, R2′ = 0.75 Ω at 50 Hz; 4 poles; rated slip from the equivalent circuit
  1. Lm = 40/(2π × 50) = 0.1273 H; leakage 1.4/314.16 = 4.456 mH; Ls = Lr = 0.1318 H
  2. σ = 1 − Lm²/(Ls·Lr) = 0.0665; τr = Lr/R2′ = 0.1757 s; stator transient time constant σLs/R1 = 10.95 ms
  3. Rated slip s = 0.0403: rotor speed 1439.6 rpm, rotor electrical speed 301.5 rad/s
  4. Synchronous frame 314.16 rad/s; rotor frame 301.5 rad/s; difference = slip speed 12.646 rad/s = 2.013 Hz
  5. dq check: ψr = Lm·is/(1 + j·ωsl·τr) gives T = 1.5·p·(Lm/Lr)·Im(ψr*·is) = 49.749 N·m = equivalent-circuit torque 49.749 N·m

Answer: Lm = 0.1273 H, Ls = Lr = 0.1318 H, σ = 0.066, τr = 0.176 s; rotor-frame currents at 2.01 Hz

Chapter 22

Vector control: the DC motor analogy, direct and indirect field orientation

Which syllabus covers thisAU not in syllabusVTU BEE613D Module 4SPPU not in syllabusMU EEC701 Module 6KTU not in syllabus

What is the DC motor analogy behind vector control?

A separately excited DC motor makes torque T = K·If·Ia: the field and armature currents are separate, and the commutator keeps them at right angles. Vector control rebuilds this in an induction motor. Put the d axis on the rotor flux: id then sets the flux (ψr = Lm·id in steady state) and iq sets the torque. For the book's 7.5 kW motor, id = 7.79 A gives ψr = 0.992 Wb, and iq = 17.31 A then gives the rated 49.75 N·m. Hasse and Blaschke developed it from 1968 into the early 1970s.

How does indirect field orientation find the flux angle without measuring flux?

It computes the slip the rotor flux must have: ωsl = iq/(τr·id). It then adds this to the measured rotor electrical speed and integrates to get the flux angle. At rated torque that is 17.31/(0.1757 × 7.79) = 12.65 rad/s, or 2.01 Hz, exactly the motor's rated slip frequency. With a fast current loop the torque follows iq at once. With a 0.5 ms current loop it reaches 90 % in 0.5 × ln 10 = 1.15 ms. A scalar V/f drive given the same step takes tens of milliseconds and wobbles while its flux settles.

Indirect field-oriented control: a torque step answered almost instantly, against the slower response of scalar V/f control: interactive loads as you scroll

What goes wrong if the controller's rotor time constant is wrong?

The slip comes out wrong, so the d axis drifts off the real flux. Torque and flux then settle at wrong values over about τr. At rated torque, if the estimate is 0.6 τr, the flux falls to 0.63 Wb and the torque to 33.5 N·m. If it is 1.6 τr, this linear model gives 1.41 Wb and 63 N·m. A real motor would saturate long before that much flux. Rotor resistance, and so τr, changes as the rotor warms up, which is why drives adapt τr online.

How is direct field orientation different, and when is scalar V/f enough?

Direct orientation measures or estimates the flux itself. Older drives used search coils. Most now use a voltage model, ψs = ∫(v − Rs·i) dt, or a current model. The voltage model fails at low speed. At 1 Hz the book motor's stator EMF is only 6.5 V peak, while the drop across Rs at rated current is 15.2 V, so a small error in Rs swamps it. Indirect orientation needs a speed or position sensor and τr. For a fan or pump that never needs fast torque, scalar V/f needs no sensor, is far simpler and is enough.

Predict, then check

An indirect FOC drive runs the book's motor at rated torque. The rotor heats up and its resistance rises 30 %, but the controller keeps the cold rotor time constant. What happens?

Worked examples

FOC set points for the book's motor at rated flux and torque · 7.5 kW motor: Lm = 0.1273 H, Lr = 0.1318 H, τr = 0.1757 s, p = 2; rated current 18.98 A peak, rated slip 0.0403
  1. In the rotor-flux frame iq/id = ωsl·τr = 12.646 × 0.1757 = 2.222
  2. id = 18.98/√(1 + 2.222²) = 7.789 A; iq = 17.307 A
  3. ψr = Lm·id = 0.1273 × 7.789 = 0.9917 Wb
  4. KT = 1.5·p·Lm²/Lr = 0.3691 N·m/A²; T = KT·id·iq = 49.749 N·m
  5. Equivalent circuit at s = 0.0403 gives 49.749 N·m: the same operating point

Answer: id* = 7.79 A, iq* = 17.31 A, ψr = 0.992 Wb, T = 49.75 N·m

A 30 N·m command at 1,000 rpm · Same motor and rated flux (id* = 7.79 A); torque command 30 N·m; rotor speed 1,000 rpm
  1. iq* = T/(KT·id*) = 30/(0.3691 × 7.789) = 10.436 A
  2. Stator current |is| = √(7.79² + 10.44²) = 13.023 A peak = 9.21 A rms
  3. Slip ωsl = iq*/(τr·id*) = 10.436/(0.1757 × 7.789) = 7.626 rad/s = 1.214 Hz
  4. Rotor electrical frequency 2 × 1,000/60 = 33.333 Hz, so the inverter runs at 34.547 Hz
  5. Check with the equivalent circuit at 34.55 Hz, s = 0.0351, voltage scaled to give 13.02 A peak: T = 30 N·m

Answer: iq* = 10.44 A, slip 1.21 Hz, inverter frequency 34.55 Hz

A detuned rotor time constant · Rated torque command; the controller uses τ̂r = 0.6 τr and then τ̂r = 1.6 τr; linear magnetics
  1. Tuned: x = ωsl·τr = iq/id = 2.222; detuned x = 2.222/k
  2. Steady state with is fixed: |ψr| = Lm|is|/√(1 + x²), T = 1.5·p·(Lm²/Lr)·|is|²·x/(1 + x²)
  3. k = 0.6: x = 3.703, |ψr| = 0.63 Wb, T = 33.46 N·m (−32.8 %)
  4. k = 1.6: x = 1.389, |ψr| = 1.412 Wb, T = 63.04 N·m (26.7 %)
  5. Torque peaks at x = 1, so at rated load (x = 2.22) a large estimate raises torque, while at light load (x below 1) it lowers it

Answer: 0.6 τr: 33.5 N·m and 0.63 Wb; 1.6 τr: 63 N·m and 1.41 Wb (over-fluxed)

Chapter 23

Direct torque control: flux and torque hysteresis and the switching table

Which syllabus covers thisAU not in syllabusVTU not in syllabusSPPU not in syllabusMU EEC701 Module 6KTU not in syllabus

What is the idea behind direct torque control?

DTC skips current loops, PWM and rotor-frame transforms. Neglect the small Rs drop and the stator flux moves at exactly the applied voltage, dψs/dt = v. So each inverter state pushes the flux tip along its own direction. Every sample, two hysteresis comparators ask whether the flux and the torque should go up or down, and a table picks the state. On a 560 V link one vector moves the flux 18.7 mWb in a 50 µs sample. Takahashi and Noguchi presented DTC in 1984 and 1986, Depenbrock filed his direct self-control patent in October 1984, and ABB launched its ACS600 DTC drives in 1995.

Which voltages can the inverter apply, and how does each change flux and torque?

A two-level inverter has eight states: six active vectors of length 2/3 × Vdc = 373.6 V, 60° apart, and two zero vectors (all legs high or all low). The radial part of a vector changes the flux magnitude. The tangential part swings the stator flux ahead of the rotor flux and raises the torque, since T = 1.5·p·Lm/(σ·Ls·Lr)·|ψs|·|ψr|·sin γ. At the book motor's rated point, |ψs| = 1.038 Wb, |ψr| = 0.992 Wb and γ = 8.4°. A zero vector parks the stator flux, the rotor flux catches up, and the torque falls.

How does the classic switching table choose a vector?

Split the plane into six sectors, each centred on one active vector Vk. If the flux and torque must both rise, apply Vk+1. Flux down but torque up: Vk+2. Torque inside its band: a zero vector, choosing 0 or 7 to need the fewest switch changes. Torque down: Vk−1 or Vk−2. In the interactive the book's motor runs at 750 rpm at rated torque. Widen a band or lengthen the sample time and the ripple grows. Each sample can overshoot a band by up to 374 V × Ts.

Direct torque control: the stator flux vector kept inside a hysteresis band by choosing one of six inverter voltage vectors: interactive loads as you scroll

How does DTC compare with field-oriented control?

DTC gives very fast torque, needs no current PI loops and no rotor parameters: the flux estimate uses only Rs. The price is a switching frequency that wanders with speed and load, and more torque and current ripple. At 750 rpm and rated torque the stator flux must turn at 169.7 rad/s, which needs 176 V of tangential voltage on average. An active vector supplies about 324 V, so active vectors fill roughly 54 % of the samples and zero vectors the rest. FOC with PWM gives a fixed frequency and smoother current.

Predict, then check

The stator flux lies in sector 1 (around V1 at 0°). The flux is below its band and the torque is below its band. Which vector does the classic table pick?

Worked examples

Vector size and flux step per sample · 415 V supply, six-pulse diode bridge, two-level inverter; book motor's rated stator flux; Ts = 50 µs and 25 µs
  1. Vdc = (3√2/π) × 415 = 560.4 V
  2. Active vector length = 2/3 × 560.4 = 373.6 V (amplitude-invariant scaling)
  3. Rated stator flux = √2 × |V − R1·I1|/ω = 1.0376 Wb (peak)
  4. Δψ in 50 µs = 373.6 × 50 µs = 18.68 mWb = 1.8 % of the flux
  5. Δψ in 25 µs = 9.34 mWb = 0.9 %

Answer: 373.6 V vectors; a 1.8 % flux step per 50 µs sample

Reading the switching table · Stator flux at 100° from the a axis; flux above its band (cψ = −1), torque below its band (cT = +1); Vdc = 560.4 V
  1. Sectors are centred on V1 at 0°, V2 at 60°, V3 at 120°; 100° lies in 90° to 150°: sector 3
  2. Table row 'flux down, torque up' gives Vk+2 = V5, at 240°
  3. Radial part = 373.6 × cos(240° − 100°) = −286.2 V: flux falls
  4. Tangential part = 373.6 × sin(140°) = 240.2 V: the flux swings forward, torque rises
  5. V4 at 180° is no good: its radial part here is 373.6 × cos 80° = +64.9 V, so it would raise the flux

Answer: Sector 3, vector V5 (state 001): radial −286 V, tangential +240 V

How often active vectors are needed at 750 rpm · Book motor at 750 rpm, rated torque 49.75 N·m, stator flux 1.038 Wb; Rs drop neglected
  1. Rotor-flux frame steady state: id = 7.789 A, iq = 17.307 A (gives |ψs| = 1.038 Wb and T = 49.75 N·m)
  2. Slip = iq/(τr·id) = 12.65 rad/s; stator flux speed = 2 × 78.54 + 12.65 = 169.73 rad/s
  3. Average tangential voltage needed = ω·|ψs| = 169.73 × 1.038 = 176.1 V
  4. Mid-sector tangential part of Vk+1 = 373.6 × sin 60° = 323.6 V
  5. Fraction of time on active vectors ≈ 176.1/323.6 = 0.544; at 50 Hz the need would be 326 V, all that one vector can give: the inverter is at its voltage limit

Answer: About 54 % active vectors, the rest zero vectors

Chapter 24

Synchronous motor drives: V/f and self-control, margin angle and power factor control

Which syllabus covers thisAU EE3012 Unit IVVTU not in syllabusSPPU 404191(B) Unit VMU EEC701 Module 5KTU not in syllabus

How does an open-loop V/f synchronous motor drive work, and what limits it?

The inverter sets the frequency and the rotor must follow it exactly, at load angle δ behind the supply. Several motors on one inverter run in perfect step. With V/f constant, V, the field EMF and Xs all scale with frequency, so the pull-out torque 3·V·Ef/(Xs·ωs) is the same at every frequency. For this chapter's illustrative 37 kW, 415 V motor at half load with unity-pf field, it is 454 N·m. The catch is acceleration: the frequency ramp must leave the rotor enough spare torque to keep up.

Why does a fast frequency ramp pull the motor out of step?

Ramping at r Hz/s asks the rotor for an extra J·2πr/p of torque on top of the load. The step in demand makes δ swing past its new balance point. If it passes 180° the torque reverses and the motor slips poles. With J = 10 kg·m² at half load, a slow quasi-static view allows 10.7 Hz/s. The equal-area criterion with no damping allows only 7.85 Hz/s, because of the overshoot. A damper winding adds some margin, and it also damps hunting, the slow swinging of δ after any disturbance.

Synchronous motor drives: open-loop V/f against self-control, and margin-angle and power-factor control: interactive loads as you scroll

What is a self-controlled synchronous motor drive?

A rotor-position sensor, or the motor's own voltages, sets the inverter's switching instants, so the stator frequency always equals the rotor speed. The controller sets δ, and through it the torque. The motor cannot pull out, because the field can never run ahead of the rotor. It behaves like a DC motor whose commutator is replaced by the inverter. In the interactive, with δ capped at 60°, it gives 393 N·m and reaches 50 Hz from 10 Hz in 4.56 s for any ramp faster than that. The PMSM and BLDC drives of the next chapters are self-controlled.

What are margin-angle control and power-factor control?

A load-commutated inverter (LCI) uses thyristors that turn off only when the motor's own back EMF reverses their current. So the current must lead the voltage by a margin angle, and the motor must be over-excited. With an illustrative 20° margin at rated load, the field rises from 10.07 A to 11.63 A, pf is 0.94 leading and the current is 54.8 A instead of 51.5 A. A 2020 ABB and Shell paper notes that only synchronous motors suit an LCI and that unity pf is then impossible. A transistor VSI can hold unity pf for the least current.

Predict, then check

The interactive's motor accelerates safely on open-loop V/f at 5 Hz/s. You switch to 20 Hz/s, first open-loop, then self-controlled. What happens?

Worked examples

Unity power factor at rated load · Illustrative 37 kW, 415 V (star), 50 Hz, 4-pole wound-field synchronous motor; Xs = 2.5 Ω, Rs neglected; Ef = 27 V per field ampere
  1. V = 415/√3 = 239.6 V; I = 37,000/(3 × 239.6) = 51.47 A in phase with V
  2. Ef = V − jXs·I: |Ef| = √(239.6² + 128.7²) = 272 V; δ = atan(128.7/239.6) = 28.24°
  3. Field current = 272/27 = 10.07 A
  4. Check: 3·V·Ef·sin δ/Xs = 3 × 239.6 × 272 × sin 28.24°/2.5 = 37000 W
  5. Pull-out torque = 3·V·Ef/(Xs·ωs) = 497.8 N·m vs rated 235.5 N·m: 2.11 times

Answer: I = 51.5 A, δ = 28.2°, If = 10.07 A, Tmax = 498 N·m

Margin-angle control for a load-commutated inverter · Same motor at rated 37 kW; the current must lead V by 20° (illustrative margin, overlap neglected)
  1. I = P/(3·V·cos 20°) = 54.78 A, leading
  2. Ef = V − jXs·I = (239.6 + 46.8) − j128.7 V; |Ef| = 314 V
  3. δ = 24.19°, If = 314/27 = 11.63 A (15.5 % more field than at unity pf)
  4. pf = cos 20° = 0.94 leading; current 6.4 % above the unity-pf value
  5. Pull-out torque rises to 574.8 N·m, so the stiffer field also helps stability

Answer: If = 11.63 A, I = 54.8 A at pf 0.94 leading, δ = 24.2°

How fast can open-loop V/f accelerate? · Half load (117.8 N·m), unity-pf field at that load, J = 10 kg·m², rotor in step at 10 Hz, ramp to 50 Hz, no damping
  1. Unity pf at half load: Ef = 248.1 V, Tmax = 454.1 N·m (same at every frequency on V/f)
  2. Extra torque for a ramp r: J·2πr/p = 31.42·r N·m
  3. Quasi-static limit: (454.1 − 117.8) × 2/(2π × 10) = 10.71 Hz/s
  4. Equal areas: δ0 = 15.03°, the critical demand 364.3 N·m (δ1 = 53.34°) makes the swing just reach 180° − δ1
  5. Critical ramp = (364.3 − 117.8) × 2/(2π × 10) = 7.85 Hz/s; a swing simulation stays in step at 0.98 times this and pulls out at 1.02 times

Answer: About 7.8 Hz/s without damping (quasi-static estimate 10.7 Hz/s); 10 to 50 Hz takes at least 5.1 s

Chapter 25

PMSM drives: torque-speed capability, MTPA and field weakening

Which syllabus covers thisAU EE3012 Unit IVVTU not in syllabusSPPU not in syllabusMU not in syllabusKTU not in syllabus

Where does a PMSM's torque come from, and what is maximum torque per ampere?

In the rotor frame, torque is 1.5·p times ψm·iq (magnet torque) plus (Ld − Lq)·id·iq (reluctance torque). A surface magnet rotor has Ld = Lq, so only iq counts and the best choice is id = 0. An interior magnet rotor has Lq bigger than Ld, so a negative id adds torque. For the book's interior PM motor at 400 A, putting all the current on the q axis gives 156 N·m; the MTPA split, id = −213 A and iq = 339 A, gives 218.6 N·m from the same current.

What sets the base speed, and what does the drive do above it?

Stator voltage grows with speed, and the inverter can only make Vdc/√3 = 202 V peak from the 350 V link. The MTPA point at 400 A reaches that limit at 3,864 rpm: the base speed, where the motor gives 88.4 kW. Above it the controller pushes id more negative to cancel part of the magnet flux and keep the voltage inside the limit. At 8,000 rpm it uses id = −364 A and iq = 166 A, so the torque falls to 137.5 N·m while the power rises to 115.2 kW.

PMSM torque-speed capability: constant torque up to base speed, field weakening above it, surface against interior magnets: interactive loads as you scroll

Why does the characteristic current ψm/Ld decide how fast the motor can run?

At very high speed the voltage depends on the d-axis flux ψm + Ld·id, so the controller must drive it towards zero. That needs id = −ψm/Ld = −433 A. With Imax at or above this characteristic current, constant power continues in theory to any speed. With less, there is a top speed Vmax/(ψm − Ld·Imax), Rs neglected: 96,483 rpm for 400 A, so the power is still 118.8 kW at 16,000 rpm. A surface PM version limited to 200 A tops out at 13,783 rpm.

What is inside a PMSM drive?

A rotor position sensor (resolver or encoder) gives the angle for the Park transform, so the drive is self-controlled: it can never pull out of step. Two fast PI loops regulate id and iq, a speed loop outside them asks for torque, and a table turns each torque and speed into the best id and iq: MTPA below base speed, field weakening above it. Space-vector PWM then sets the inverter switching. The dq-plane picture of the current circle and voltage ellipse is in the Electric Vehicles book.

Predict, then check

A surface PM motor (Ld = Lq) runs below base speed. For the most torque per ampere, where should the controller put id?

Worked examples

MTPA for an interior PM motor · The book's IPM motor: p = 4, ψm = 0.065 Wb, Ld = 0.15 mH, Lq = 0.35 mH, current limited to 300 A peak (illustrative)
  1. MTPA: id = [ψm − √(ψm² + 8(Lq − Ld)²I²)] / [4(Lq − Ld)] = −145.9 A
  2. iq = √(300² − id²) = 262.1 A
  3. Magnet torque 1.5 × 4 × 0.065 × 262.1 = 102.2 N·m; reluctance torque 1.5 × 4 × (0.15 − 0.35)×10⁻³ × (−145.9) × 262.1 = 45.9 N·m
  4. Total 148.1 N·m; with id = 0: 1.5 × 4 × 0.065 × 300 = 117 N·m
  5. A golden-section search over the current angle gives the same id = −145.9 A

Answer: id = −146 A, iq = 262 A, T = 148.1 N·m, 27 % more than id = 0

Base speed of a surface PM motor · Surface PM: ψm = 0.065 Wb, Ld = Lq = 0.15 mH, p = 4, 400 A peak, Vmax = 350/√3 V, Rs neglected (illustrative)
  1. Below base speed id = 0 and iq = 400 A
  2. Flux linkage |ψ| = √(ψm² + (Lq·iq)²) = √(0.065² + 0.06²) = 0.0885 Wb
  3. Base electrical speed ωe = Vmax/|ψ| = 202.07/0.0885 = 2284 rad/s; mechanical 571.1 rad/s = 5,454 rpm
  4. Torque 1.5 × 4 × 0.065 × 400 = 156 N·m; power at base = 156 × 571.1 = 89.1 kW

Answer: Base speed 5,454 rpm, 156 N·m, 89.1 kW

Field weakening at 1.5 times base speed · The same surface PM motor at 1.5 × base speed, 400 A, Rs neglected (illustrative)
  1. ωe = 1.5 × 2284 = 3427 rad/s; the voltage limit is a circle: (ψm + Ld·id)² + (Ld·iq)² = (Vmax/ωe)²
  2. With id² + iq² = 400²: id = [(Vmax/ωe)² − ψm² − Ld²·400²] / (2·ψm·Ld) = −222.9 A
  3. iq = √(400² − id²) = 332.1 A, T = 1.5 × 4 × 0.065 × 332.1 = 129.5 N·m
  4. Power = 129.5 × 856.6 = 111 kW (base: 89.1 kW)
  5. Top speed Vmax/(ψm − Ld·Imax)/p = 202.1/0.005/4 rad/s = 96,483 rpm, because 400 A is just under ψm/Ld = 433 A

Answer: id = −223 A, T = 129.5 N·m, P = 111 kW

Chapter 26

BLDC drives: six-step inverter, Hall sensors and sensorless back-EMF commutation

Which syllabus covers thisAU not in syllabusVTU BEE613D Module 5SPPU 404191(B) Unit IIMU not in syllabusKTU not in syllabus

How is a BLDC drive different from a PMSM drive?

A BLDC motor is wound for a trapezoidal back-EMF with 120° flat tops. The six-step inverter drives two phases at a time with flat current blocks, so e·i summed over the phases is constant and torque = 2·ke·I. For an illustrative 48 V scooter motor, ke = 0.07 V·s/rad at 20 A gives 2.8 N·m. Rotor position is needed only six times per electrical cycle, so three Hall sensors are enough. A PMSM has a sinusoidal back-EMF, takes sinusoidal currents, and needs a continuous angle from an encoder or resolver.

How does sensorless commutation find the rotor without Hall sensors?

In every 60° step one phase floats. It carries no current, so its terminal voltage measured against the virtual neutral is its own back-EMF. That EMF crosses zero halfway through the float, 30° electrical before the next commutation should happen. The controller times 30° from the length of the previous step, then switches. At 1,500 rpm with 4 pole pairs the electrical frequency is 100 Hz, so 30° takes 0.83 ms. In the interactive, a +10° error stretches that to 40° = 1.11 ms.

Sensorless BLDC commutation: the floating phase's back-EMF zero crossing, the 30 degree delay and what a timing error costs: interactive loads as you scroll

What does a commutation timing error cost?

A late or early switch drives a phase while its EMF is still on the ramp. With ideal current blocks the average torque is 1 − δ²/7200 of ideal (δ in electrical degrees), the same early or late: 98.6 % at 10° and 87.5 % at 30°. The dips are worse than the average suggests: the torque falls to 1 − |δ|/60 once per step, a ripple of 17 % at 10° and 57 % at 30°. Winding inductance slows the current's rise, which is why a small advance helps at high speed. The ideal-current model does not show that.

Why does back-EMF sensing fail at standstill and low speed?

Back-EMF is proportional to speed: 22 V at 3,000 rpm but zero at standstill, so there is nothing to detect at start. Below a few volts, comparator offsets and PWM noise hide the zero crossing: with a 2 V threshold the illustrative motor needs 273 rpm. Drives therefore start open loop, aligning the rotor and then ramping the commutation rate until the EMF is readable, or they fit Hall sensors. Starting from an arbitrary phase can turn the motor backwards briefly. Observers estimate the EMF from the measured voltages and currents.

Predict, then check

A sensorless BLDC drive waits 30° electrical after each zero crossing. The motor speeds up from 1,000 rpm to 2,000 rpm. What happens to that wait in milliseconds?

Worked examples

Commutation timing · 4-pole-pair BLDC at 2,400 rpm, six-step drive (illustrative)
  1. Electrical frequency fe = p·n/60 = 4 × 2,400/60 = 160 Hz
  2. One 60° step lasts 1/(6·fe) = 1.042 ms; commutations per second = 6 × 160 = 960
  3. Zero crossing to commutation = half a step = 30° = 0.521 ms

Answer: Commutate 0.521 ms after each zero crossing, 960 times per second

A filter delay becomes a timing error · The zero-crossing comparator's filter delays the signal by 0.1 ms; same motor; ke = 0.07 V·s/rad, I = 20 A (illustrative)
  1. At 2,400 rpm (fe = 160 Hz): δ = 0.1 ms × 360° × 160 Hz = 5.76° late
  2. Average torque = 1 − δ²/7200 = 1 − 33.18/7200 = 99.54 %, so 2.8 N·m becomes 2.787 N·m
  3. At 3,000 rpm: δ = 7.2°, loss 0.72 %; the error grows with speed
  4. Torque dips to 1 − δ/60 = 90.4 % once per step at 2,400 rpm

Answer: δ = 5.76°: 0.46 % average torque lost at 2,400 rpm; fix it by subtracting the known delay from the 30° wait

Lowest speed for sensorless running · Comparator needs at least 1.5 V of back-EMF; ke = 0.07 V·s/rad, 4 pole pairs, rated 3,000 rpm (illustrative)
  1. ω = 1.5/0.07 = 21.43 rad/s = 205 rpm
  2. That is 6.8 % of rated speed; electrical frequency 13.6 Hz
  3. Below it the drive runs open loop (or on Hall sensors) and hands over once crossings are seen

Answer: About 205 rpm (6.8 % of rated)

Chapter 27

Switched reluctance motor drives: torque from changing inductance

Which syllabus covers thisAU not in syllabusVTU BEE613D Module 5SPPU not in syllabusMU not in syllabusKTU not in syllabus

How does an SRM make torque with no magnets and no rotor winding?

The rotor is a stack of steel laminations with salient poles. An energised stator phase pulls the nearest rotor pole towards alignment, the position of least reluctance and highest inductance. With linear magnetics the torque is ½·i²·dL/dθ. In this book's illustrative 6/4 motor, L rises from 8 mH to 60 mH over 30°, so dL/dθ = 0.0993 H/rad and 15 A gives 11.2 N·m while L rises. Where L falls the same current brakes, so each phase gets current only on its rising stretch.

Why does an SRM drive use an asymmetric half bridge?

Torque goes with i², so the current's direction does not matter and each phase needs only unipolar current. The asymmetric bridge, the most common SRM converter, puts one switch above and one below each winding, with two diodes. Both switches on apply +Vdc. One switch on lets the current freewheel at 0 V, which is soft chopping. Both off send the stored energy back to the link capacitor through the diodes at −Vdc. Each phase has its own leg, so one faulty phase does not short the others.

How do the turn-on and turn-off angles shape the torque?

At 1,000 rpm the phase switches on at 10°. The current reaches 15 A within 2.4°, before L starts rising at 13°, and chopping holds it. It switches off at 40° and the current is gone by 56°, leaving a short braking tail after L starts falling at 47°. Average torque is 10.54 N·m, ripple 55 %. Above about 1,875 rpm the back-EMF i·ω·dL/dθ plus the R·i drop exceeds 300 V, the current can no longer be held, and the drive runs single-pulse with an earlier turn-on.

Switched reluctance motor: phase inductance against rotor angle, torque from a current pulse, and torque ripple: interactive loads as you scroll

What is the energy-conversion loop, and how does it give the average torque?

Plot flux linkage against current for one stroke. The current rises along the unaligned line, flux builds while the rotor turns, then both fall back to zero. The enclosed area W is the mechanical work of that stroke. A 6/4 motor makes 3 × 4 = 12 strokes per revolution, so average torque = 12·W/2π: the interactive's 5.52 J gives 10.54 N·m. The cost is torque ripple and noise, which the controller must limit, by shaping the current or controlling flux linkage. SRMs are used in some appliances and industrial sewing machines.

Predict, then check

You reverse the current in an SRM phase winding but keep its size. What happens to the torque?

Worked examples

Torque at constant current · Illustrative 6/4 SRM: L rises from 8 mH to 60 mH over 30° of rotation; phase current 15 A
  1. dL/dθ = (0.060 − 0.008)/(30° × π/180) = 0.0993 H/rad
  2. T = ½ × 15² × 0.0993 = 11.17 N·m while L rises
  3. Strokes per revolution = phases × rotor poles = 3 × 4 = 12; stroke angle = 360°/12 = 30°
  4. The rising stretch (30°) equals one stroke, so with ideal current blocks the phases hand over with no gap

Answer: 11.17 N·m per phase, 12 strokes per revolution

Average torque from the energy per stroke · Same motor; (a) ideal: 15 A switched on and off instantly at the ends of the rising stretch; (b) the interactive's default (chopping, 1,000 rpm, 10° to 40°)
  1. (a) Loop area W = ½ × 15² × (0.060 − 0.008) = 5.85 J
  2. (a) Average torque = 12 × 5.85/(2π) = 11.17 N·m, the same as Example 1
  3. (b) Simulating the phase (dψ/dt = v − R·i, ψ = L(θ)·i) gives W = 5.519 J and a peak of 15.55 A
  4. (b) Average torque = 12 × 5.519/(2π) = 10.54 N·m: the current's rise time and its tail into falling L cost 5.7 %

Answer: 11.17 N·m ideal; 10.54 N·m with real current shapes

When chopping stops working · Same motor, 300 V link, R = 0.5 Ω, 15 A reference
  1. While L rises, the back-EMF is i·ω·dL/dθ; chopping needs 300 ≥ R·i + i·ω·dL/dθ
  2. ω = (300 − 0.5 × 15)/(15 × 0.0993) = 196.3 rad/s = 1,875 rpm
  3. At 3,000 rpm the back-EMF at 15 A would be 15 × 314.2 × 0.0993 = 468 V, more than the 300 V link, so the current falls while L rises
  4. Time to build 15 A from zero in the unaligned region: t = −(L/R)·ln(1 − iR/V) = 0.405 ms, which is 2.43° at 1,000 rpm

Answer: Chopping holds 15 A up to about 1,875 rpm; above that, single-pulse control with turn-on advanced

Chapter 28

Stepper motor drives: excitation modes, L/R and chopper drives, pull-out torque

Which syllabus covers thisAU not in syllabusVTU not in syllabusSPPU 404191(B) Unit VIMU not in syllabusKTU not in syllabus

How does a stepper motor move and hold position without feedback?

Each energised phase pulls the rotor teeth into line with the stator teeth, the position of least reluctance; a hybrid rotor adds a magnet. Change which phases carry current and the rotor jumps one step. A two-phase hybrid with 50 rotor teeth has 4 × 50 = 200 full steps per revolution, or 1.8° each, a common rating. The controller just counts pulses: 1,000 pulses per second is 300 rpm. Push the rotor off position and the restoring torque grows up to the holding torque; beyond that it slips a step and the count is wrong.

What do wave, two-phase-on, half-step and microstep excitation change?

With one phase on (wave), the illustrative motor holds 0.85 N·m at 2 A. Two phases on add as vectors: √2 times, 1.2 N·m, for twice the copper loss. Half stepping alternates one and two phases: 0.9° steps, but the torque alternates between 0.85 and 1.2 N·m. Microstepping sets sine and cosine currents. At 1/8 step, 0.225°, the current vector keeps a constant length, so motion is smooth and torque stays at the one-phase level.

Why does torque fall with step rate, and how do L/R(4) and chopper drives help?

A winding is an R-L circuit: τ = L/R = 2 ms. At 500 full steps/s with two phases on, each winding reverses every 4 ms. A plain 3 V L/R drive then reaches only 76 % of rated current, giving 0.29 N·m. With 12 V and 4.5 Ω in series, τ falls to 0.5 ms and the motor gives 0.9 N·m, halving only at 1,044 steps/s. That resistor wastes three times the motor's copper loss. A chopper uses a 36 V bus with no resistor and switches to hold 2 A.

Stepper motor drives: winding current with an L/R drive against a chopper drive, and pull-out torque falling with step rate: interactive loads as you scroll

What are pull-out and pull-in torque, and when is closed-loop control needed?

Pull-out torque is the load a running motor carries at a given step rate before it stalls or misses steps. Pull-in torque, measured without an acceleration ramp, is lower because the motor must also accelerate the rotor and load inertia within each step. Near the mechanical resonance the rotor rings, and steps may be lost. Drives therefore ramp the step rate and keep a torque margin. An encoder closes the loop: lost steps are detected and corrected. The interactive ignores back-EMF and resonance, so its curves are optimistic at high rates.

Predict, then check

Same stepper, same current per winding. You switch from wave drive (one phase on) to two phases on. The holding torque becomes about:

Worked examples

How far the current gets in one step · Winding 1.5 Ω, 3 mH, rated 2 A; wave drive at 250 full steps/s; (a) L/R drive 3 V, (b) L/R(4): 12 V with 4.5 Ω in series (illustrative)
  1. Step time 1/250 = 4 ms; (a) τ = 3 mH/1.5 Ω = 2 ms; (b) τ = 3 mH/6 Ω = 0.5 ms
  2. (a) End of step: i = 2(1 − e^(−4/2)) = 1.729 A; average over the step = 2[1 − (τ/T)(1 − e^(−T/τ))] = 1.135 A
  3. (b) End of step: 2(1 − e^(−8)) = 1.999 A; average 1.75 A
  4. Torque goes with average current: (a) 57 %, (b) 88 % of the one-phase holding torque; the shaft turns at 75 rpm

Answer: (a) 1.14 A average (57 %), (b) 1.75 A (88 %)

The price of the series resistor · One winding held at 2 A: (a) L/R(4) drive, 12 V with 4.5 Ω in series; (b) ideal chopper (illustrative)
  1. Motor copper loss = 2² × 1.5 = 6 W in both cases
  2. (a) Series resistor loss = 2² × 4.5 = 18 W; supply gives 12 × 2 = 24 W = 6 + 18 W
  3. (b) The chopper switches its 36 V bus so the average winding voltage is only 2 × 1.5 = 3 V; supply power ≈ 6 W
  4. With two phases on, every figure doubles

Answer: L/R(4) draws 24 W per winding to deliver what the chopper does with 6 W

Pull-out torque with two phases on · Same winding, plain 3 V L/R drive (τ = 2 ms), two phases on at 500 full steps/s; holding torque 1.2 N·m (two on) (illustrative)
  1. Each winding sees a square wave of ±3 V with half period 2 steps = 4 ms
  2. Periodic peak current = 2·tanh(Tp/2τ) = 2·tanh(1) = 1.523 A (76 % of rated)
  3. Mean current in the commanded direction = I − (I + Ipk)(τ/Tp)(1 − e^(−Tp/τ)) = 0.477 A
  4. Torque (simplified) = 1.2 × 0.477/2 = 0.286 N·m, 24 % of holding
  5. Torque halves at 261 steps/s with this drive and at 1,044 steps/s with L/R(4)

Answer: About 0.29 N·m at 500 steps/s (24 % of holding torque)

Keep going

Recommended reading

  • Fundamentals of Electrical Drives, G. K. Dubey
  • A First Course on Electrical Drives, S. K. Pillai
  • Modern Power Electronics and AC Drives, B. K. Bose
  • Electric Motor Drives: Modeling, Analysis and Control, R. Krishnan
  • Electrical Drives: Concepts and Applications, Vedam Subrahmanyam
  • Power Semiconductor Controlled Drives, G. K. Dubey
  • Electric Drives, N. K. De and P. K. Sen

How this book was made

Chapters follow the official syllabi listed above. Every interactive's formulas and every worked-example number were checked by script. Explanations, animations and examples are original to Skill-Lync.

From the exam to a core job

Talk to a counsellor.

Ask how motor and drives engineers use electrical drives on real projects, and what the PMSM Control Theory course covers.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.