Limits and fits calculator (ISO 286)
Pick a nominal size and an ISO hole and shaft class, such as H7/g6. You get both sets of limits, the maximum and minimum clearance or interference, the fit type and a to-scale zone diagram. Sizes up to 500 mm, grades IT1 to IT14, letters c to u. Free, no sign-up, runs in your browser.
ISO 286-1:2010 values · 10,338 limits verified by script · Updated 16 Nov 2026
Size step 24–30 mm
What does a fit like H7/g6 mean?
An ISO fit names a hole class and a shaft class. The letter is the fundamental deviation: where the tolerance band sits relative to the nominal size. Capital letters are holes, lower case are shafts; H and h touch the nominal size; letters towards A/a sit further from it on the clearance side, letters towards Z/z on the interference side. The number is the IT grade: how wide the band is. H7/g6 at 25 mm is a hole of 25.000 to 25.021 mm on a shaft of 24.980 to 24.993 mm.
Each class therefore needs two numbers from ISO 286-1 for your size step: the fundamental deviation (one limit) and the IT value (the band width). The other limit follows:
For holes A to H the table gives the lower deviation EI; for shafts a to h it gives the upper deviation es; from J/j onwards it is the other way round. Then the fit:
A negative clearance is an interference. If both are positive it is a clearance fit, if both are negative an interference fit, and if the signs differ it is a transition fit.
Worked example: Ø25 H7/g6 and H7/p6
25 mm falls in the 18 to 30 mm step for IT grades (and 24 to 30 mm for the letters that use finer steps). There, and .
- H7 hole: , so 25.000 to 25.021 mm.
- g6 shaft: (es is the fundamental deviation of g), so 24.980 to 24.993 mm.
Always a gap of 7 to 41 µm: a clearance fit. ANSI B4.2 calls H7/g6 the sliding fit, for parts that must move and turn freely yet locate accurately.
Swap the shaft for p6: .
Both negative: an interference of 1 to 35 µm, a light press fit. ANSI B4.2 intends this locational interference fit for accurate location and rigidity, not for carrying load through the grip of the fit; that is the job of the drive and force fits (s6, u6) or a key.
Why do H7/p6 and P7/h6 give the same fit?
If you mirrored the shaft rule for holes (), the hole-basis fit H7/p6 and the shaft-basis fit P7/h6 would not match, because the hole is one grade coarser than the shaft. ISO 286-1 fixes that with a correction for holes K, M and N up to IT8 and P to ZC up to IT7 (sizes over 3 mm):
At 25 mm, with p's lower deviation of +22 µm and :
P7/h6 then gives an interference of 1 to 35 µm, identical to H7/p6. The calculator applies automatically; set a hole letter from K to U to see it.
ISO tolerance grades (IT) table
The IT value is the width of the band in µm. It grows with size and roughly ×1.6 per grade from IT6 up. For IT5 and coarser, ISO 286-1 derives it from the standard tolerance factor , using the geometric mean of the size step:
, then rounded. For the 18 to 30 mm step:
| Size (mm) | IT4 | IT5 | IT6 | IT7 | IT8 | IT9 | IT10 | IT11 | IT12 | IT13 | IT14 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0–3 | 3 | 4 | 6 | 10 | 14 | 25 | 40 | 60 | 100 | 140 | 250 |
| 3–6 | 4 | 5 | 8 | 12 | 18 | 30 | 48 | 75 | 120 | 180 | 300 |
| 6–10 | 4 | 6 | 9 | 15 | 22 | 36 | 58 | 90 | 150 | 220 | 360 |
| 10–18 | 5 | 8 | 11 | 18 | 27 | 43 | 70 | 110 | 180 | 270 | 430 |
| 18–30 | 6 | 9 | 13 | 21 | 33 | 52 | 84 | 130 | 210 | 330 | 520 |
| 30–50 | 7 | 11 | 16 | 25 | 39 | 62 | 100 | 160 | 250 | 390 | 620 |
| 50–80 | 8 | 13 | 19 | 30 | 46 | 74 | 120 | 190 | 300 | 460 | 740 |
| 80–120 | 10 | 15 | 22 | 35 | 54 | 87 | 140 | 220 | 350 | 540 | 870 |
| 120–180 | 12 | 18 | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 |
| 180–250 | 14 | 20 | 29 | 46 | 72 | 115 | 185 | 290 | 460 | 720 | 1150 |
| 250–315 | 16 | 23 | 32 | 52 | 81 | 130 | 210 | 320 | 520 | 810 | 1300 |
| 315–400 | 18 | 25 | 36 | 57 | 89 | 140 | 230 | 360 | 570 | 890 | 1400 |
| 400–500 | 20 | 27 | 40 | 63 | 97 | 155 | 250 | 400 | 630 | 970 | 1550 |
Values in µm, ISO 286-1:2010, "over" the lower size up to and including the upper. IT1 to IT3 are in the calculator. As a rough guide (it varies with machine and setup): grinding and honing reach IT5 to IT7, reaming and fine boring IT6 to IT8, turning and milling IT7 to IT11, drilling IT10 to IT13.
Which fit should I use? The ISO preferred fits at 25 mm
ISO 286-1 (Annex) and ANSI B4.2 list ten preferred hole-basis fits. The use descriptions below follow ANSI B4.2; the clearances are this calculator's values at Ø25 mm. Pick one in the calculator to see it at your size.
| Fit | Type | Clearance (+) / interference (−) at Ø25, µm | Typical use |
|---|---|---|---|
| H11/c11 | Loose running clearance | +110 to +370 | Wide commercial tolerances, or allowances on external members |
| H9/d9 | Free running clearance | +65 to +169 | Not where accuracy matters; good for large temperature changes, high speeds or heavy journal pressure |
| H8/f7 | Close running clearance | +20 to +74 | Running on accurate machines and accurate location at moderate speeds and journal pressures |
| H7/g6 | Sliding clearance | +7 to +41 | Not meant to run freely, but to move and turn freely and locate accurately |
| H7/h6 | Locational clearance clearance | 0 to +34 | Snug fit for locating stationary parts that can still be freely assembled and taken apart |
| H7/k6 | Locational transition transition | −15 to +19 | Accurate location, a compromise between clearance and interference |
| H7/n6 | Locational transition transition | −28 to +6 | More accurate location where more interference is acceptable |
| H7/p6 | Locational interference interference | −35 to −1 | Rigidity and alignment with prime accuracy of location, without special bore-pressure needs |
| H7/s6 | Medium drive interference | −48 to −14 | Ordinary steel parts or shrink fits on light sections; the tightest fit usable with cast iron |
| H7/u6 | Force interference | −61 to −27 | Parts that can be highly stressed, or shrink fits where the pressing force needed is impractical |
The shaft-basis equivalents (C11/h11, D9/h9, F8/h7, G7/h6, H7/h6, K7/h6, N7/h6, P7/h6, S7/h6, U7/h6) give exactly the same clearances for sizes over 3 mm (the Δ rule takes care of K to U); use them when one shaft of standard bright bar carries several parts. For rolling bearings, use the bearing maker's recommended shaft and housing classes, which depend on load direction and size.
Hole basis or shaft basis?
Hole basis (H holes, shaft letter varies) is the default in most industries: holes are made with fixed-size reamers and checked with fixed plug gauges, while a shaft can be turned or ground to any size. Shaft basis (h shafts, hole letter varies) suits long bright-drawn shafts that carry several parts with different fits. ISO 286 also allows fits where neither part is H or h, but one system per drawing set keeps tooling and gauges simple.
Why do some tables show ±10 µm for js7 at 25 mm?
The 1988 edition of ISO 286 rounded odd IT7 to IT11 values down to the even number below before halving, so js7 at 18 to 30 mm (IT7 = 21 µm) was printed as ±10 µm. ISO 286-1:2010 gives exactly ±IT/2, ±10.5 µm, and so does this calculator. Older handbooks and some CAD libraries still carry the rounded values; the difference is at most 0.5 µm per limit.
Skill-Lync's design courses teach fits, GD&T and datums on industry drawings, the way design engineers use them at automotive and product companies.
- Geometric Dimensioning and Tolerancing (12 weeks, NX CAD: datums, MMC/LMC, position, profile)
- Post Graduate Program in CAD (48 weeks)
- Post Graduate Program in Manufacturing Design (24 weeks)
- Design for Manufacturability (DFM) (5 weeks)
Frequently asked questions
What does H7/g6 mean?
H7/g6 is an ISO fit: the hole has fundamental deviation H (its lower limit is the nominal size) and tolerance grade IT7; the shaft has deviation g (a little under nominal) and grade IT6. At 25 mm the hole is 25.000 to 25.021 mm and the shaft 24.980 to 24.993 mm: a sliding clearance fit of 0.007 to 0.041 mm.
What is the tolerance of H7 at 25 mm?
H7 at 25 mm is +0.021 / 0 mm, so the hole can be 25.000 to 25.021 mm. The width, 21 µm, is the IT7 value for the 18 to 30 mm size step; H puts the lower limit on the nominal size. The same IT7 band at 50 mm is 25 µm and at 100 mm 35 µm.
What is the difference between clearance, transition and interference fits?
In a clearance fit the smallest hole is still larger than the largest shaft, so there is always a gap (H7/g6). In an interference fit the largest hole is smaller than the smallest shaft, so parts must be pressed or shrunk together (H7/p6, H7/s6). A transition fit can give either, depending on the actual parts (H7/k6, H7/n6).
What is the difference between hole basis and shaft basis?
In the hole-basis system every hole is H (lower deviation zero) and the shaft letter sets the fit, for example H7/g6 or H7/p6. In the shaft-basis system every shaft is h and the hole letter changes, for example G7/h6. Hole basis is the usual choice because reamers and plug gauges for holes come in fixed sizes.
Why do H7/p6 and P7/h6 give the same fit?
ISO 286 adds a small correction, delta, to the upper deviation of holes K to N up to IT8 and P to ZC up to IT7. Delta is the difference between the hole's IT grade and the next finer one. It makes the hole-basis and shaft-basis versions of a fit give the same clearance or interference for sizes over 3 mm: at 25 mm both give 0.001 to 0.035 mm interference.
How do I calculate the limits from an ISO tolerance class?
Look up two numbers for your size step: the fundamental deviation for the letter (es or EI for a to h, ei or ES from j on) and the IT value for the grade. The other limit is the first one minus the IT value for shafts (ei = es - IT) or plus it for holes (ES = EI + IT). The calculator does both lookups and shows the zone diagram.
Does this calculator follow ISO 286-1:2010?
Yes. The IT grades and fundamental deviations are the ISO 286-1:2010 values for nominal sizes up to 500 mm, IT1 to IT14, letters c to u (and C to U). Each value was checked against two independent published tables and the ISO rules by a script. The 2010 edition gives js and JS as exactly plus or minus IT/2.
Related on Skill-Lync
- All free design and quality tools
- Tolerance stack-up calculator: worst case, RSS and Monte Carlo
- True position calculator: MMC bonus tolerance and virtual condition
- GD&T symbols explained: chart, datums and MMC
- All about tolerance stack-up analysis
- DFM checklist with sheet metal, moulding and CNC rule calculators
- FMEA RPN and Action Priority calculator
- Compare Skill-Lync's SolidWorks courses
Sources and how we checked
- ISO 286-1:2010, Geometrical product specifications (GPS) — ISO code system for tolerances on linear sizes — Part 1: Basis of tolerances, deviations and fits (IT grades, fundamental deviations, the Δ rule, the M6 250–315 mm special case) and ISO 286-2:2010 (tables of tolerance classes).
- ANSI B4.2-1978 (R2020), Preferred Metric Limits and Fits: the ten preferred fits and their descriptions.
- Verification: Skill-Lync's scripts/verify/iso286.py holds the table and rules and compares them with RoyMech's ISO 286 tables (182 IT values, 450 shaft and 800 hole deviation cells) and the ISO 286-2 class limits in the open-source isofits project (1,460 classes × size steps, MIT licence). Every disagreement was traced to a typo in one source, confirmed by the other source and the ISO rule; the list is in the script. This page then recomputes all 10,338 limits in TypeScript at build time (11,200 combinations checked) and refuses to build on any difference.