Battery pack calculator

Work out how many cells go in series and in parallel for any pack energy and voltage. For 18 kWh at about 400 V from ANR26650M1-B cells, the answer is 122S18P: 2,196 cells, 402.6 V and 18.117 kWh, or 120S19P if you size on the datasheet's 2.4 Ah minimum capacity.

You get the fewest-cell configuration near your voltage, the energy at the rated and at the datasheet-minimum capacity, the full and empty voltage, current and power limits, the mass of the cells, the size of the cell block with a drawing, and the I²R heat at a current. It opens on the 18 kWh ANR26650M1-B pack of Skill-Lync's battery technology course. The second tab checks the S, P, voltage and energy in your report. Free, no sign-up, runs in your browser.

Cell data as printed by A123 Systems (2012) and Lithium Werks · checked against an exact-fraction script · Updated 20 Nov 2026

The calculator tries the whole series counts up to two either side of pack voltage ÷ cell voltage, keeps those within 3% of your voltage, and picks the one needing the fewest cells. "Usable DoD" below 100% adds cells so that share of the energy alone meets the target. Cell resistance defaults to the datasheet's 1 kHz AC impedance, which is lower than the DC resistance, so the heat shown is a lower bound.

Configuration122S18P2,196 cells
Energy18.117 kWh17.392 kWh at 2.4 Ah
Voltage402.6 V244 to 439.2 V
122 groups of 18 · 3 per row · 41 rows1,512 mm × 1,148 mm × 65 mm cell block
  • Capacity 45 Ah (43.2 Ah at minimum). Continuous 900 A = 362 kW at 402.6 V (220 kW at 244 V); 10 s pulse 2,160 A.
  • Cells weigh 166.9 kg (109 Wh/kg, cells only).
  • Cell block 1,512 × 1,148 × 65 mm = 112.8 L (cells themselves 75.8 L); 1 empty group place{LY.empty === 1 ? "" : "s"} in the last row.
  • At 45 A (2.5 A per cell), I²R heat is at least 82.4 W.
SPCellsNominal VkWh
119192,261392.718.653
120192,28039618.810
121192,299399.318.967
122182,196402.618.117
123182,214405.918.265

What is the 18 kWh battery pack project?

"Battery pack capacity: 18 kWh. Cell: ANR26650M1-B. Prepare a detailed battery pack drawing along with its enclosure. State your assumptions." That is project 1 of Skill-Lync's Introduction to Battery Technology for Electric Vehicle, which also runs inside the battery, EV and hybrid PG programs. 655 public student reports of it are on Skill-Lync, and Skill-Lync read all of them on 20 Nov 2026.

The cell is a 26650 lithium iron phosphate (LiFePO₄) power cell: 26 mm across, 65 mm long, 3.3 V and about 2.5 Ah. Before anyone draws holders or an enclosure, they have to decide how many cells go in series (S, which sets the voltage) and in parallel (P, which sets the capacity). That decision is what this calculator makes, and it is where most of the reports go slightly wrong.

How many cells does an 18 kWh pack need?

Each cell stores its voltage times its capacity:

So 18,000 Wh ÷ 8.25 Wh = 2,181.8, which rounds up to 2,182 cells. 142 of the 655 reports quote that number. The catch: a pack is S groups of P cells, so the cell count must be S × P, and 2,182 = 2 × 1,091, where 1,091 is prime. No real pack has 2,182 cells.

The smallest counts that can be arranged, with 12 to 140 cells in series, are:

  • 2,183 cells: only 37S59P (122.1 V, 147.5 Ah).
  • 2,184 cells: 39S56P, 42S52P, 52S42P, 56S39P, 78S28P, 84S26P, 91S24P, 104S21P and more. 91S24P (300.3 V) is the fourth most common answer in the reports.
  • 2,196 cells: 122S18P (402.6 V), the most common answer, and 61S36P (201.3 V).

If you size on the datasheet's minimum capacity of 2.4 Ah (7.92 Wh per cell) instead, it takes at least 2,273 cells.

How do you choose cells in series and in parallel?

Pick the pack voltage first, because the motor and inverter fix it. Then:

Round S to a whole number, then work out P with that rounded S and round P up. For 400 V: 400 ÷ 3.3 = 121.2. The calculator tries the whole numbers up to two either side (all within 3% of 400 V here) and keeps the one with the fewest cells:

SNominal VP on 2.5 AhCellskWhP on 2.4 AhCellskWh at 2.4 Ah
119392.7192,26118.653202,38018.850
120396192,28018.810192,280 (fewest)18.058
121399.3192,29918.967192,29918.208
122402.6182,196 (fewest)18.117192,31818.359
123405.9182,21418.265192,33718.509

Rounding S up to 122 lets P drop from 19 to 18, which saves 103 cells over 121S19P. That is why 122S18P is the best 400 V answer on the 2.5 Ah rating: 2,196 cells, 45 Ah, 18.117 kWh. 79 of the 655 reports chose it.

Should you size on the rated or the minimum capacity?

The A123 datasheet gives the ANR26650M1-B as 2.5 Ah nominal, 2.4 Ah minimum. A cell from the factory can have anything from 2.4 Ah up. If every cell in 122S18P came in at 2.4 Ah, the pack would store 17.392 kWh, 3.4% short of 18.

Skill-Lync parsed the pack-level S × P of every report that states one: 335 of the 655. 278 of those 335 (83%) store less than 18 kWh at the 2.4 Ah minimum, and 32 are short even at 2.5 Ah. Only 87 reports mention the 2.4 Ah figure at all. Sizing on the minimum, the fewest cells near 400 V is 120S19P: 2,280 cells, 396 V, 18.058 kWh at worst and 18.810 kWh at 2.5 Ah.

The current Lithium Werks page lists the same cell as 2.6 Ah typical, 2.5 Ah minimum and 8.58 Wh. On that sheet, 2.5 Ah is the minimum, and 122S18P meets 18 kWh even at minimum capacity. Which is right depends on which sheet you cite, so cite one, and say which capacity you sized on. Real packs are also not run from 100% to 0%; if only 90% of the energy is usable, 18 kWh usable on 2.4 Ah takes 121S21P (2,541 cells). Set "Usable DoD" in the calculator to try it.

Which configurations did the reports choose?

The eight most common pack configurations in the 655 reports, all with A123 datasheet values:

ConfigReportsCellsNominal VFull / empty VAhkWh (2.5 Ah)kWh (2.4 Ah)Cells (kg)
122S18P792,196402.6439.2 / 2444518.11717.392166.9
48S48P372,304158.4172.8 / 9612019.00818.248175.1
50S44P362,200165180 / 10011018.15017.424167.2
91S24P342,184300.3327.6 / 1826018.01817.297166
100S22P242,200330360 / 2005518.15017.424167.2
60S36P202,160198216 / 1209017.82017.107164.2
22S100P102,20072.679.2 / 4425018.15017.424167.2
46S48P92,208151.8165.6 / 9212018.21617.487167.8

Highlighted: under 18 kWh. 60S36P is short even at 2.5 Ah; at 2.4 Ah only 48S48P still makes it, because it carries the most cells. 22S100P is a 72.6 V pack with 250 Ah, a choice for a low-voltage motor, not a swap of 100S22P.

What voltage, current and power does 122S18P give?

A LiFePO₄ pack's voltage moves a lot between full and empty. 122S18P reads 439.2 V fully charged (3.6 V per cell), 402.6 V nominal and 244 V at the 2.0 V minimum. The charger, contactors and DC link must be rated for 439.2 V, and the inverter must still make power at 244 V.

Each cell can deliver 50 A continuously and 120 A for 10 s, so 18 in parallel give 900 A continuous (362 kW at nominal voltage, 220 kW near empty) and 2,160 A for 10 s. These are cell limits. The busbars, fuses, contactors and cooling set the real ones. The heat:

With the datasheet's 6 mΩ (1 kHz AC impedance), 1C (45 A) gives 2.5 A per cell and 82.4 W for the whole pack. At the full 900 A it is 15 W per cell, 32.9 kW of heat, which no 26650 pack sheds without serious cooling. DC resistance is higher than the 1 kHz figure and rises in the cold, so treat these as lower bounds; Skill-Lync's battery thermal management project models the rest.

How big and heavy is the cell block?

The cells alone weigh 2,196 × 76 g = 166.9 kg, which is 109 Wh/kg. Holders, busbars, the BMS, cooling plates and the enclosure all add to that, and the project asks you to state what you assume for them.

On a square grid with a 2 mm gap the cell pitch is 28 mm. Put each parallel group of 18 in a line (504 mm) and 3 groups side by side: 41 rows, a 1,512 × 1,148 × 65 mm block of 112.8 L, of which the cells fill 75.8 L. Staggered (hexagonal) rows bring the rows 13.4% closer together. The drawing in the calculator follows the groups per row and gap you set, with alternate parallel groups in alternate colours so the series order is visible.

Which mistakes show up in the reports?

  • S rounded down, P kept. 20 reports take 200 V, get 200 ÷ 3.3 = 60.6, use 60 in series, but keep P = 18,000 ÷ (2.5 × 200) = 36, worked out for the unrounded voltage. 60S36P is 198 V and 17.82 kWh, 1% short. With S = 60, P must be 37.
  • P rounded down. 18,000 ÷ (121 × 8.25) = 18.03. Three reports take 18, giving 121S18P at 17.9685 kWh. Round P up.
  • A cell count that is not S × P. 142 reports quote 2,182 cells; the pack they then draw has a different number. Use S × P for mass, cost and the drawing.
  • Rated capacity taken as guaranteed. 83% of the stated packs fall below 18 kWh at the 2.4 Ah minimum, and only 87 reports mention it.
  • Also caught by the Check tab: the full-charge voltage used as nominal, 3.2 V instead of the datasheet's 3.3 V, S and P swapped, Wh written as kWh, and a pack mass lighter than its cells.

What this calculator does not cover

  • Holders, busbars, enclosure and BMS. It sizes the cells and the cell block. Wall thickness, crash structure, venting and cable routing are the drawing part of the project.
  • Capacity at other temperatures, rates and ages. The datasheet capacity is at 0.5C and room temperature; cold, high current and cycling all reduce it. Size with margin, or use DoD below 100%.
  • Cell-to-cell spread inside a group. A parallel group shares current by resistance, and a series string is limited by its weakest group. Balancing and binning are BMS topics.
  • Thermal behaviour. The heat line is a steady I²R estimate with the AC impedance. Temperature rise needs a thermal model with the cooling path.
Learn battery pack design

The 18 kWh pack is project 1 of Skill-Lync's battery technology course, followed by thermal modelling of the pack, battery chemistry and drive-cycle studies. Pack sizing, BMS and thermal management are what EV battery teams hire for.

Frequently asked questions

How many ANR26650M1-B cells does an 18 kWh battery pack need?

At least 2,182 by energy alone (18,000 Wh ÷ 8.25 Wh per cell = 2,181.8), but 2,182 = 2 × 1,091 cannot be arranged as a real series × parallel pack. The smallest arrangements are 37S59P (2,183 cells, 122.1 V) and 2,184 cells (91S24P at 300.3 V, 52S42P, 42S52P and others). For about 400 V the fewest cells is 122S18P: 2,196 cells, 402.6 V, 45 Ah, 18.117 kWh.

What is the best series-parallel configuration for an 18 kWh, 400 V pack?

With the cell's 2.5 Ah rating, 122S18P (2,196 cells, 18.117 kWh, 402.6 V nominal, 244 to 439.2 V). If you size on the A123 datasheet's minimum capacity of 2.4 Ah, 120S19P (2,280 cells, 396 V, 18.058 kWh even at minimum capacity). 122S18P is the most common answer in Skill-Lync students' reports: 79 of 655.

How do I calculate cells in series and parallel for a battery pack?

Series count S = pack voltage ÷ cell nominal voltage (round to a whole number). Parallel count P = pack energy ÷ (S × cell voltage × cell capacity), rounded up. Total cells N = S × P. Then recheck the energy with the rounded S and P: rounding S down and keeping the P worked out for the unrounded voltage leaves the pack short, which is what 60S36P (17.82 kWh) does.

What is the voltage range of a 122S LiFePO4 pack?

With ANR26650M1-B cells: 402.6 V nominal (122 × 3.3 V), 439.2 V fully charged (122 × 3.6 V) and 244 V at the 2.0 V minimum. The charger, contactors and inverter must handle 439.2 V; the motor drive must still deliver power at 244 V.

How much does an 18 kWh 26650 battery pack weigh?

The cells alone: 2,196 × 76 g = 166.9 kg for 122S18P, or 109 Wh/kg. Holders, busbars, the BMS, cooling and the enclosure come on top, so a pack weighs more than this.

Why do different reports use 2.4, 2.5 or 2.6 Ah for the same cell?

Two datasheets. A123 Systems' 2012 sheet gives 2.5 Ah nominal and 2.4 Ah minimum. Lithium Werks' current product page gives 2.6 Ah typical and 2.5 Ah minimum, with 8.58 Wh. Both are the same cell; say which sheet and which figure you sized on.

Related on Skill-Lync

Sources

  • A123 Systems, "Nanophosphate High Power Lithium Ion Cell ANR26650M1-B" datasheet MD100113-02 (2012): 3.3 V, 2.5 / 2.4 Ah nominal / minimum at 0.5C, 76 g, 26 × 65 mm, 6 mΩ (1 kHz AC typical), 50 A continuous, 120 A for 10 s, standard charge 2.5 A to 3.6 V CCCV, −30 °C to 55 °C.
  • Lithium Werks, ANR26650m1B product page (read 20 Nov 2026): 2.6 Ah typical (2.5 Ah minimum), 8.58 Wh, 76.0 ± 1.5 g, Ø25.96 ± 0.5 × 65.40 ± 0.25 mm, <10 mΩ, 52 A continuous, 120 A for 10 s, 2.0 V minimum, charge to 3.6 V.
  • Skill-Lync, all 655 public reports of "Mechanical design of battery pack", read 20 Nov 2026: 549 name the 26650 cell, 522 the 18 kWh target, 335 state a parseable pack-level S × P (the largest S × P in the text, 16 to 22 kWh).
  • Skill-Lync, scripts/verify/battery-pack.py: every figure on this page in exact fractions (cell counts, the factorisation of 2,182, the configuration search, voltage window, energy at both capacities, block size, heat). The page recomputes them in its own code and fails the build if they differ.
Free counselling

From a cell datasheet to an EV battery career.

Sizing a pack, drawing it, keeping it cool and managing it with a BMS is the work battery and EV teams test for. A Skill-Lync counsellor can map the course that fits the role you want.

Talk to a course counsellor

Free. We call you back, usually the same day.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.