Automotive fuse and wire size calculator (12 V, 24 V)

Pick the blade fuse for a car circuit the way the fuse maker says to, with the derating for a hot fuse box. Then size the wire for its voltage drop and work out the battery a load needs, hours included. Free, no sign-up.

ISO 8820-3 blade fuse ratings · Littelfuse ATOF + MINI derating tables · ISO 6722-1 conductor resistance · copper α 0.00393 · Peukert · Updated 20 Nov 2026

Load

Fuse

Engine-bay fuse boxes run hot; a box in the cabin is close to 25 °C. The fuse is picked from Littelfuse's maximum allowed current at that temperature (ATOF −40 to 125 °C, MINI −40 to 100 °C). A power in watts overrides the current (I = P / V). Use the steady current; motors and lamps take a short inrush that a slow-blow or the fuse's time curve has to ride through.

Fuse to fit15 ABlue
Allowed at 25 °C13.8 Acontinuous, Littelfuse table
Load on it73%of the allowed current
123457.510152025303540
  • A 10 A fuse would carry only 9.78 A at 25 °C. The "125% of the load" rule gives 12.5 A, which is not a rating; the next one up is 15 A.

How to choose a fuse rating for a car circuit

A fuse is there to protect the wire. It has to carry the circuit's normal current all day without ageing, and blow before the wire behind it overheats. A fuse's rating is not the current it should carry: its element runs hot near the rating, and hotter still in a warm fuse box. Littelfuse publishes, for each blade fuse rating, the maximum continuous current it allows at each ambient temperature (with a 20% temperature margin built in). Pick the smallest rating that covers the load:

For the challenge's 10 A load in a 25 °C cabin box, a 10 A ATO fuse allows only 9.78 A, so the answer is a 15 A (Blue) blade fuse, which allows 13.8 A. In an 85 °C engine-bay box it still allows 11.0 A. A MINI fuse derates faster: at 100 °C a 15 A MINI allows 9.0 A, so the same load needs 20 A. Littelfuse's general design guide says the same thing more simply: at 25 °C, load a fuse to no more than 75% of its rating (10 ÷ 0.75 = 13.3 A, so 15 A). Blade fuses come in fixed ratings only:

RatingATO colourMINIAllowed 25 °CAllowed 85 °CTest cable
1 ABlack–1.0 A1.0 A0.35 mm²
2 AGreyyes2.0 A2.0 A0.35 mm²
3 AVioletyes3.0 A2.0 A0.35 mm²
4 APinkyes3.9 A3.0 A0.35 mm²
5 ATanyes4.9 A4.0 A0.5 mm²
7.5 ABrownyes6.9 A5.0 A0.75 mm²
10 ARedyes9.8 A7.0 A1 mm²
15 ABlueyes13.8 A11.0 A1.5 mm²
20 AYellowyes17.7 A14.0 A2.5 mm²
25 ANaturalyes22.6 A18.0 A2.5 mm²
30 AGreenyes26.6 A21.0 A4 mm²
35 ABlue Green–34.3 A27.0 A6 mm²
40 AOrange–36.3 A28.0 A6 mm²

Allowed currents are Littelfuse's ATOF table (between its temperatures, read in a straight line). Then check the other direction. The wire after the fuse has to cope with the fuse's rated current, not just the load, because currents a little above the rating can flow for minutes before the fuse opens. The "test cable" row is the wire Littelfuse tests each rating on (ISO 8820-3 set-up): a 15 A fuse is tested on 1.5 mm². A thinner wire behind it needs the cable maker's current rating checked.

How to size the wire: voltage drop

In a 12 V system the wire size is usually set by voltage drop, not by heat. Every volt lost in the wire is a volt the lamp, motor or ECU does not get. The drop is the current times the resistance of the whole circuit: the feed, plus the return wire if there is one (a chassis ground return is short and thick, so only the feed counts). Copper's resistance rises 0.393% per °C, so a warm wire drops more:

A 10 A load 3 m from the battery with a return wire is 6 m of circuit. At 60 °C, 1.0 mm² (ISO 6722 maximum 18.5 mΩ/m at 20 °C) drops 1.28 V, 10.7% of 12 V. Within 3% you need 4 mm² (0.33 V). The 500 W load of question 4 draws 41.7 A; on a 2 m run with a return wire it needs 10 mm² for the same 3%.

A widely used limit, from the ABYC E-11 standard for boats' 12 V systems, is 3% for circuits where voltage matters (electronics, main feeds, navigation lights) and 10% for other lighting and non-critical loads. Vehicle makers set their own; the calculator lets you choose.

How big a battery for a 500 W load

A battery's capacity is in ampere-hours: current × time. A 500 W load on 12 V draws I = 500 ÷ 12 = 41.7 A, and that is all you can say until you know how long it runs. For 1 hour it uses 41.7 Ah (500 Wh). Two corrections turn that into a battery to buy:

  • Depth of discharge. A deep-cycle lead-acid battery is meant to be discharged no more than about 50%; deeper cycles cut its life (Battery University: 400-500 cycles at 50%, 150-200 at 100%). 41.7 Ah ÷ 0.5 = 83.3 Ah.
  • Peukert. A lead-acid battery's rated capacity is measured over 20 hours (C20: a 100 Ah battery gives 5 A for 20 h). Drawn in 1 hour, it gives less. With k = 1.25, an average for lead-acid, the 1-hour case needs a 132 Ah C20 battery; for 3 hours, 318 Ah. For loads slower than the 20-hour rate the calculator does not give Peukert credit, and keeps I × t ÷ depth.

Car starting batteries are rated for cranking, not for cycling: their Ah figure is real, but taking half of it every day shortens their life. For a load like this, use a deep-cycle or lithium battery, or run it with the engine on so the alternator carries it.

What 606 student answers got wrong

"Project - Analysis of a practical automotive wiring circuit" asks students to read a car's wiring diagram, then: "If the total load is 10 A from battery, what should be the fuse rating?" and "If 500 W is the load, what is the voltage and capacity of battery you recommend?" 606 reports are public, and we read all of them (counts as of 20 Nov 2026; regex counts with random samples hand-checked; 329 state a fuse answer we could parse, 421 answer the battery question).

AnswerReportsWhat is wrong with it
Fuse 15 A157The right rating. Only 13 of the 329 mention the fuse box temperature, and 19 the wire it protects.
Fuse 12.5 A (125% of 10 A)39No such blade fuse. The next rating is 15 A. Even if it existed, 10 A would load it to 80%, over the 75% limit.
Fuse 13 A23"A bit more than 10 A". 13 A is a UK mains plug fuse, not a car fuse.
Battery 12 V, "41.67 Ah"about 60500 ÷ 12 = 41.67 is a current in amperes. With no runtime it is not a capacity.
Battery 50 V (500 W ÷ 10 A)62The 10 A belongs to question 3. The battery voltage is the vehicle's system: 12 V for a car, 24 V for a truck.
1,000 Ah (24 h) or 30,002 Ah (a month)42+The arithmetic is right; the runtime is invented. A month of 500 W is 360 kWh, as much as six 60 kWh electric-car batteries hold.
  • The runtime is the missing input. 211 reports assume one: 1 hour in 117, 24 hours in 42. The rest give no time at all. The honest answer to question 4 is a table like the one in the Battery tab, with the time stated.
  • 12 V is right. 284 reports pick 12 V. Only 4 mention the alternator, which decides whether the battery has to carry the load on its own at all.
  • Watt-hours and kilowatt-hours. A few write 500 W × 3 h = "1500 kWh"; it is 1,500 Wh, 1.5 kWh.

What this calculator does not cover

  • Wire temperature rise. The wire tab sizes for voltage drop. How hot a wire runs at a current depends on its insulation, the bundle and the air around it; check the cable maker's current rating for your insulation class (ISO 6722 classes A to E, 85-175 °C).
  • Fuse time curves. The allowed currents are for steady loads. Inrush, motor stall and the fuse's melting time (the I²t that decides whether it blows in a short or rides through a start) need the maker's time-current curve.
  • Battery ageing and cold. Capacity falls with age and with temperature; a lead-acid battery at 0 °C gives noticeably less than its 25 °C rating. Add margin for both.
  • High-voltage EV circuits. Traction batteries at 400-800 V use different fuses, cables (ISO 19642, orange) and rules.
Learn vehicle electrical design

Fuse and wire sizing is the first job of a wiring harness engineer. Skill-Lync's harness courses take it on to full harness design in CATIA V5.

How we checked the calculator

The independent Python script scripts/verify/autoelec.py runs 76 checks, and this page recomputes all its examples with the browser code at build time and refuses to build if they differ.

  • Tables compared value by value with a second copy, and against the PDFs themselves: all 13 ATOF and 10 MINI rows of the temperature tables, and all 11 cable sizes in the Prysmian FLRY-B sheet (LEONI's catalogue gives the same values). Each conductor's resistance × area is checked to be that of stranded copper, each derating row to fall with temperature.
  • Fuse pick found by trying every rating in the list, not by the formula; voltage drop recomputed on 5 circuits.
  • Peukert capacity found by bisection on the discharge-time equation and compared with the closed form the page uses on 9 cases; with k = 1 it reduces to I × t ÷ depth.
  • The reports' numbers reproduced: 41.67 A, 50 V, 1,000 Ah, 30,002.4 Ah, 1.5 kWh.

Frequently asked questions

What fuse should I use for a 10 A load in a car?

A 15 A blade fuse (Blue). Littelfuse's ATOF temperature table lets a 10 A fuse carry only 9.78 A continuously at 25 °C, so a steady 10 A load needs the next rating up, 15 A, which carries 13.8 A. In an 85 °C engine-bay box the 15 A fuse still carries 11.0 A. The general rule of loading a fuse to at most 75% of its rating gives the same 15 A. The wire after the fuse must suit the fuse's rating, not just the load.

Is a 12.5 A fuse available for cars?

No. Blade fuses (ISO 8820-3) come in 1, 2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30, 35, 40 A for the regular ATO size, and 2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30 A for MINI. The "125% of the load" rule gives 12.5 A for a 10 A load, so round up to the next standard rating: 15 A.

How do you calculate the fuse rating?

Take the steady load current and the temperature where the fuse sits. Pick the smallest standard rating whose maximum allowed current at that temperature (from the fuse maker's derating table) is at least the load. Without a table, Littelfuse's general rule is to load a fuse to no more than 75% of its rating at 25 °C and derate further for heat. Then check the wire: the fuse protects the wire, so the wire has to suit the fuse's rating.

What size wire do I need for 10 A at 12 V?

It depends on the length. For a 3 m feed with a 3 m return wire (6 m of circuit), at a 60 °C conductor temperature and a 3% (0.36 V) drop limit, the smallest ISO 6722 size is 4 mm², which drops 0.33 V. With a chassis return, only the feed counts and a smaller wire may do.

What battery do I need for a 500 W load?

At 12 V a 500 W load draws 41.7 A. The capacity depends on how long it runs, which the question does not say: for 1 hour it needs 41.7 Ah of energy, and with a lead-acid battery discharged to 50% and a Peukert exponent of 1.25, a 132 Ah (C20) battery. For 3 hours, 318 Ah. Writing "41.67 Ah" without a time is a current, not a capacity.

Why is 12 V used in cars?

Cars use a 12 V lead-acid battery (six 2.1 V cells, about 12.6 V full) charged at about 14 V by the alternator; trucks and buses use 24 V (two 12 V batteries in series) because heavy starters draw half the current at twice the voltage, so the cables can be thinner. 48 V mild-hybrid systems do the same for electric compressors and starter-generators.

Is this calculator free?

Yes. It runs in your browser, needs no sign-up and sends nothing anywhere.

Related on Skill-Lync

Sources

  • Littelfuse, ATO Fuse Fast-Acting Type (257 series): ratings 1-40 A, colour code and cold resistance (Ordering Information table).
  • Littelfuse, ATOF Blade Fuses Rated 32V, Rev. 08/18/2022 (same in 09/27/2024): Ratings table (test cable size per rating) and Temperature Table, maximum allowed current -40 to 125 °C, 20% temperature security margin, test set-up to ISO 8820-3.
  • Littelfuse, MINI Blade Fuse 297, Rev. 09/27/2024: ratings 2-30 A and maximum allowed current load at -40 to 100 °C based on typical derating.
  • Littelfuse, Fuseology Design Guide (2022): rerating, 'operated at no more than 75% of the nominal current rating' at 25 °C, fuse selection checklist.
  • LEONI, Single-core automotive cables, FLRY type A/B, and Prysmian datasheet DB-F-049 FLRY-B (2020): conductor resistance at 20 °C and outside diameter to ISO 6722-1 (the two agree on every size).
  • NBS Handbook 100, Copper Wire Tables (1966): temperature coefficient 0.00393 per °C at 20 °C as specified by the IEC.
  • Victron Energy, BMV-712 manual, Battery capacity and Peukert exponent: Cp = In t, n = 1.25 as an average for lead-acid, C20 definition.
  • Rolls Battery user manual (2017): deep-cycle batteries 'intended to be discharged no more than 50%'; Battery University BU-201: cycle life vs depth of discharge.
  • ABYC, What is voltage drop (E-11): 3% maximum for critical circuits, 10% for lighting and non-critical circuits.
Free counselling

From a wiring diagram to a harness design job.

Fuse and wire sizing, routing rules and CATIA harness models are what harness suppliers test freshers on. A Skill-Lync counsellor can map the course that fits the role you want.

Talk to a course counsellor

Free. We call you back, usually the same day.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.