Challenge

To plan a structural layout and to create grids using TSD

Q1.Summarize the user interface in TSD with the for the following items: -

  • Project Workspace – How to access and usage 
  • Scene Content – Demonstrate the use of scene content
  • Create two scene views
  • Loading drop list- How to access
  •  Properties windows – how to access and usage

ANS :

AIM : To summarize the user interface in TSD with the for the following items: -

  • Project Workspace – How to access and usage 
  • Scene Content – Demonstrate the use of scene content
  • Create two scene views
  • Loading drop list- How to access
  •  Properties windows – how to access and usage

PROCEDURE :

1.PROJECT WORKSPACE :

Open the Tekla Structural Designer Software and the software will open as follows

Click on new option under home tab to create new model work space

Project Workspace is now active, all the Ribbons and Menu bars are visible and can used in the project

2.SCENE CONTENT

Go to Windows tab in that select scene content

The scene content checkbox will appear in that select the elements which need to be visible and hidden

3.CREATE TWO SCENE VIEWS

Tekla Software itself will create two default views i.e., 2D and 3D view

Grid lines are drawn to show the different views

2D VIEW

3D VIEW

4.LOADING DROP LIST

On the left side of the workspace clock on the plus icon near the loading to open the loading drop down list their various load cases and combinations which are created will be displayed

5.PROPERTIES WINDOWS

Go to Windows tab Select Properties windows to open or close it

RESULT : The given question is Solved

 

2. Create a new file in TSD and set up the settings for a steel building to have member grade FE410 and concrete grade of M30 as per IS codes. The covers for the members to be as per the following input: -

MEMBERS

IN CONTACT WITH GROUND

ABOVE GROUND

Column

50mm

40mm

Slab

30mm

25mm

Pile cap

75mm

 

Foundation

50mm

 

ANS :

AIM : To Create a new file in TSD and set up the settings for a steel building to have member grade FE410 and concrete grade of M30 as per IS codes. The covers for the members to be as per the following input: -

MEMBERS

IN CONTACT WITH GROUND

ABOVE GROUND

Column

50mm

40mm

Slab

30mm

25mm

Pile cap

75mm

 

Foundation

50mm

 

PROCEDURE :

Open the Tekla Structural Designer Software and the software will open as follows

Click on new option under home tab to create new model work space

Project Workspace is now active, all the Ribbons and Menu bars are visible and can used in the project

In home tab select Materials  

In the appeared dialogue box select material and in that select Steel under Material type and India under Regional code and Select Fe410WA under available grades and click on default

Select Concrete under Material type and India under Regional code and Select M30 under available grades and click on default

To change the cover settings click on the settings option in the home tab, Setting dialogue box will appear in that under loading section select Structural default

Select SSL option and apply the cover values corresponding to contact with ground

 

Select TOF option and apply the cover values corresponding to above ground

RESULT : The Given Question is been solved


3. With reference to the input drawing as per Attachment 1, 1.1, and 1.2 and study the steel building plan and summarize your understanding of the plan.  Based on your study assume and explain the location of columns and beam and develop a hand sketch for each plan

ANS :

The first step of any structural planning is to study the architectural drawing given and to check the various properties like geometry, symmetry, stiffness, redundancy etc. After this assigning the columns and beams are done before planning for foundation or any other components.

Column placement should be done properly considering some of the points

<!-- [if !supportLists]-->·         <!--[endif]-->At or near the corners of the building

<!-- [if !supportLists]-->·         <!--[endif]-->At intersection of beams or walls

<!-- [if !supportLists]-->·         <!--[endif]-->Select positions in such way to avoid bending moment in beam

<!-- [if !supportLists]-->·         <!--[endif]-->To avoid larger spans of beams

<!-- [if !supportLists]-->·         <!--[endif]-->To avoid centre to centre distance between columns

<!-- [if !supportLists]-->·         <!--[endif]-->Column on property line

<!-- [if !supportLists]-->·         <!--[endif]-->Column should not be placed at opening or at areas having less spaces

GROUND FLOOR PLAN

FIRST FLOOR PLAN

ELEVATION

 

4. Model grid lines and construction levels as per Attachment 1. 1.1 and 1.2. All dimensions are in mm

  • The base level to be 500mm below ground level.

ANS :

AIM : To Model grid lines and construction levels as per Attachment and base level should be 500mm below the ground level

PROCEDURE :

Open the Tekla Structural Designer Software and the software will open as follows

Click on new option under home tab to create new model work space

Project Workspace is now active, all the Ribbons and Menu bars are visible and can used in the project

Go to model tab select construction level, the construction level dialogue box will appear

Create construction levels as Base, Ground Floor, First Floor, Roof beam level and Roof Top and Height as per the attachment

In model tab select grid line and quick parallel grid line option to create horizontal and vertical grid lines as per the dimensions given in the attachments

RESULT : The construction levels and grid lines are drawn corresponding to the given attachments