Sketch a G+1 residential plan according to Vaastu Shastra and Calculation of Loads as per IS code
Sketch a G+1 floor residential plan, according to Vaastu Shastra, and list down the names of the structural drawings required to be provided to the site for construction.
Also, assume the sizes of the structural elements (Column, Beam, Slab, etc.,) and accordingly calculate the individual corresponding loads from the members as per IS code.
Ans: Find the attached (file attached separately) drawing for G+1 floor Residential plan according to Vaastu shastra.
The list of structural drawings required to be provided to site are as follows
- General notes and typical details for the structure
- Centre line drawing
- Footings and columns layout details drawing
- Plinth beam layout details drawing
- First floor level beams and slab layout details drawing
- Roof level beams and slab layout details drawing
- Staircase, headroom and water tank layout details drawing
- Boundary wall and underground water and septic tank layout details drawing
Load calculations
- Consider column size 300mm x 230mm and height of floor 3m
Dead Load of column = 0.30m x0.23m x3.00m x25KN/cum = 5.175 KN
- Consider beam size 230mm x 450mm and length of beam 4m
Dead Load of beam = 0.23m x0.45m x4.00m x25KN/cum = 10.35 KN
- Consider Slab thickness 125mm and span 3m x 4m
Dead Load of slab = 0.125m x 3m x 4.00m x25KN/cum = 37.5 KN
- Consider external brick wall 230mm length 3m height 3.55m
Dead Load of Brick wall = 0.23m x 3m x 3.55m x20KN/cum = 48.99 KN
- Consider Floor finish form room size 3m x 4m
Dead Load of floor finish = 3m x 4m x 1KN/sqm = 12 KN
- Consider room size of 3m x 4m for live load
Live load for 3m x 4m room = 3m x 4.00m x2KN/sqm = 24 KN
- Consider Terrace size of 3m x 4m for live load
Live load for 3m x 4m terrace = 3m x 4.00m x3KN/sqm = 36 KN