Challenge

Reinforcement detailing of Columns from ETABS output

Aim:

Reinforcement detailing of columns in Etabs .

The ETABS file for a G+4 building is provided. Run the analysis and design the RCC Moment Resisting Frame. The following challenge deals specifically with two columns at the following grid intersections.

  1. 3A
  2. 3B
  • Provide details of longitudinal reinforcement for the two columns, from foundation to terrace level. Sketch the column cross sectional & elevation details or draft it using autocad software.
  • Show shear reinforcement & lapping details as per special confining reinforcement provision of clause 8.1 of IS 13920 - 2016.

INTRODUCTION:

Detailing rule of any Reinforced concrete member:

1. Minimum reinforcement for shrinkage & temperature

2. Ultimate limit state design rebar requirement

3. Ductility rebar requirement

(Whichever is greater, Should be drawn in RC column detailing)

  • Minimum longitudinal reinforcement as per IS-456-2000 clause 26.5.3.1 A 2340 mm2
  • Minimum shear (or) transverse reinforcement as per IS-13920-2016 clause 7.4.2 - 8mm dia at 300mm spacing
  • Development length as per IS-456-2000 clause 26.2.1 L = 41 x diameter of bar

PROCEDURE :

Design of RC columns:

Step-1:

  • Go to analyse tab , then go to check Model
  • Now select the Frames
  • After selecting , run the analysis

Step-2:

  • Go to the Design tab and then go Frame Design Preference
  • Now go to Concrete Frame Design Combination, then click on Star Design
  • Using the above toolpath, the given ETABS model is ensured for its design code assignment and combination assignments. Then the ETABS model is design initiated

Step-3:

  • Go to Design tab , then go to Verify all members passed
  • Now click on the Display design info ,then go to Flexural reinforcement
  • Ater that go to the Display design info , then click on Shear reinforcement

  • As per the noted rebar outputs, the Longitudinal sections for those two RC beams are drawn using AutoCAD software and detailing is done complying IS 13920-2016 requirements
  • As per clause 8.1 of IS13920-2016, the special confining reinforcement is calculated and verified with the drawing detail.
  • As per cluase 8.1 section a), the confining reinforcement length Lo should be at least of below three :

i) larger dimension of frame member (650mm)

ii) 1/6th of clear span (575mm)

iii) 450mm

So ; Lo= 650mm

  • As per cluase 8.1 section b), the maximum spacing of confining reinforcement shall be

i) 1/4th of minimum member dimension (112.5mm)

ii) 6 times of smallest longitudinal rebar (120mm)

iii) 100mm

So maximum shear link spacing maintained = 100mm

Minimum special confining reinforcement should be maximum of (a) or (b)

(a) Ash= 632

(b) Ash= 337

Therefore ; Ash =632 sq mm/m

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.