Challenge

Identification of Cracks

CHALLENGE 01

1.

a)

Observation:

  • Concrete crushed and reinforcement is exposed.
  • Concrete spalled beyoned the reinforcement which may be a sign of rupture.
  • Beam top portion looks safe because of the flange advantage from the slab.
  • The crack develops in bottom to top which means rebar yeilding occurs in support bottom only.

Answer:

  • It's form of Flexural failure due to reversal of stress during earthquake.
  • During stress reversal, support top experiences compression and bottom experiences tension.
  • Top compression is managed by slab advantage. Bottom tension was not satisfied by the provided reinforcement.
  • Since the reinforcement got yeilded, it cannot be repaired.

b)

Observation:

  • Cracks along beam-column edge.
  • Cracks seem to have developed through the structure as it looks much wider.
  • Beam looks seperated from the column at joints.
  • Concrete is not severly crushed.

Answer:

  • It's Beam Pull out failure due to insufficient developement lenght of reinforcement in joints.
  • During earthquake, the horizontal movement of structure makes this condition worse and detached the beam member from the column.
  • Providing the anchorage length between the two existing concrete is very difficult. So, it is not repairable.

c)

Observation:

  • Cracks are excatly at the joint of column-beam.
  • Cracks in beam developed through its entire width.
  • Slab also developed more cracks along the beam width direction.

Answer:

  • It's a Plastic hinge failure.
  • The damage occured only in joint zone first of all.
  • Cyclic lateral loading and stress reversal at the joints led to the damage.
  • Even the slab participated to its best to handle the tension, but unable to control the damage.
  • The joint can be strengthened.

2.

a)

Observation:

  • Concrete damaged at the top of a column.
  • Spalling of concrete occurs all around the column face.
  • Beams are safe.
  • The location of looks at edge of the building.
  • No walls are built along the column means it is probably at the ground floor, for parking car movement access.

Answer:

  • It's a Soft storey failure, technically plastic hinge formation.
  • Due to the absence of infill walls at the ground floor, the plastic hinge forms at the top of ground storey columns during lateral movement.
  • Based on the development of cursh or spall of concrete, it can either repairable or non-repairable.

b)

Observation:

  • Concrete developed complete breakage diagonally.
  • Longitudinal reinforcements are intact.
  • Shear reinforcement spacing looks wider, which means probably lesser shear reinforcement provided.

Answer:

  • It's a Pure Shear failure.
  • Inadequate shear reinforcement compels concrete takes all the shear stress.

c)

Observation:

  • Concrete failed completely.
  • Failure at the top of cloumn.
  • There are two slabs connected to the column, probably one at mid height of the column.
  • The wooden piles might be a post failure support after column failed, providing temporary prop to avoid collapse of the entire structure.

Answer:

  • It's a Short column failure.
  • An additional slab or a Beam connected to a column in mid-height leads to this effect.
  • This leads to failure especially if the connection is unintentional and non accounted in design.
  • The failure given in the picture is not at all repairable.
Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.