Challenge

Identification of Cracks

Question 1:

A)

Observation:

  • Concrete crushed and the reinforcement is exposed.
  • Concrete spalled beyond reinforcement which may be sign of rupture.
  • Beam top portion looks safe beacuse of the flange advantage from slab.
  • the crack develops from bottom to top means rebar yielding occurs in support bottom only.

Solution:

  • Its from of flexural failure due to reversal of stress during earthqake.
  • During stress reversal support top experiences compression and bottom experiences tension.
  • TOp compression is managed by slab advantage. Bottom tension was not satisfied by the provided reinforcement
  • since the reinforcement got yielding it can not be repaired.

b)

Observation:

  • Crakes along beams and column edge
  • crakes seems to be have devoloped through the stracture as it looks much better
  • Beams looks seperated from the column at the joints
  • Concrete is not sevearly crushed.

Solution:

  • Its beam pullout failure due to insafficient development length of reinforcement in joints
  • During eartquake the horizontal moment of stracture makes this condition worse and detached the beam memeber from column.
  • Provideing anchorage length between two existing concrete is very difficult . so not repeirable.

c)

Observation:

  • Cracks are exactly at the join of column beam
  • Cracks in beam developed through its entire width
  • Sab also developed more cracks a long the beam width direction

SOlution:

  • Its plastic hinge failure
  • The damage occured only in the joint zone first of all.
  • Cycalic lateral loading, stress reversal at the joints led to the damage
  • EVen the slab partisipated to its best to handle the tension ( slab is sevearly craked means it has undergone tension with its flange condition) but unable to control the damage.
  • the joint cen be strengthened.

What is the mode of failure or damage of the beams in the figure above? Are the damages repairable? Elaborate

Question 2:

a)

OBservation:

  • Concrete damaged at the top of the column
  • Concrete damaged all around the column face.
  • Beams are safe.
  • The location of the column looks at edge of the building.
  • No walls are built along the column means it is propably at ground floor for parking car movement acess.

Solution:

  • Its a soft story failure, tehnically plastic hinge formation.
  • Due to absence of infill walls at the ground story columns duroing lateral moment
  • based on the development crush of the concrete IT can iether be reperable or nor repirable.

b)

Observation:

  • Concrete developed complete breakage diagonally
  • Longitudnal reinforcement are intact.
  • Shear rainforcement spaceing looks wider (which means propably lesser shear rebar provided)

Solution:

  • Its is a pure shear failure.
  • Inadequate shear rainforcement compels concrete takes all te shar stresses.

c)

Observation:

  • Column failed completely
  • Failure at top of the column
  • there are two slabs connected to the column propably one midheight of the column
  • The wooden piles might be a post failure support after colum failed. provideing temporary prop t avoid collapse of the entire stracture.

Solution:

  • its a short column failure
  • an additional slab or a beam connected to a column mid-height leads to this effect.
  • this leads to failure especially if the connection is unintentinal and not accounted in design
  • the failure in the picture is not at all repirable.