Design a square footing for a column size of 400x400. The compression axial load for the load combination of (1.5 DL + 1.5 LL) is 2000 KN. The safe soil bearing capacity is 150 KN/m2 at a depth of 2 metres below E.G.L. Participants are free to go for either a tapered or stepped footing. Besides the total axial load, also account for the self-weight of the footing and soil above it. Assume M25 concrete grade. Do the following checks:

  • If the gross bearing pressure under the footing is within safe bearing capacity
  • Provide sufficient depth and longitudinal steel for resisting bending and shear
  • Sufficient anchorage for column steel into the footing
  • If the bearing pressure at column-footing joint is within 0.45 times the maximum concrete compressive strength

Aim- designing a footing for a column size of 400x400.

Given Data-

Column size = 400x400

Compression axial load P = 2000 KN.

Fck = M25

Fy = Fe500

Soil bearing capacity = 150 kn/m2

Procedure –

Gross Soil Pressure And Footing area

Unfactored load with surcharge + self weight of the footing / allowable soil pressure

10% of the load is taken for self weight.

= (2000/1.5 x 1.1)/150 = 9.77m2

We assume a square footing.

Therefore,

Square root of 9.77m2 = 3.12m each side.

Net soil pressure and depth of the footing.

Factored load / actual area of footing.

2000 / (3.2 x3.2)

= Pn = 195.3 kN/m2

Assume the depth of the footing 500 mm.

Check it for bearing stress as per IS 456-2000 clause 34.4.

Therefore,

Permissible bearing stress 0.45 x Fck = 0.45 x 25 = 11.25 N/mm2

Permissible bearing stress multiplied by the area factor of 2 = 11.25 x 2 = 22.5 N/mm2

Actual bearing stress at the column base of the footing.

2000 x 1000 / 400x 400 =12.5 N/mm2

Actual bearing stress < permissible bearing stress.

12.5 N/mm2<22.5N/mm2

Hence 500 mm depth is okay and provide 50 mm for cover.

Effective depth = 450mm

Bending Moment and flexural reinforcement.

Bending moment due to UDL = wL2/ 2

Where,

w= net pressure into UDL.

w = 195.3 x 3.2 = 652 kN/m

= wL2 / 2

= 625 x 1.62 / 2

Mu = 800 kNm

Area of steel for 1m

Ast = 0.5x 25/ 500 x (1- √1- (4.6x 800 x 106)/ 25 x 1000 x 5002) x 1000 x500

Ast = 1450 mm2

Total Ast required = 4350mm2

No of bars

= Mu / Π/4 x d2.

= 4350 / Π/4 x 162

= 22 nos

Spacing,

S = L / Nos of bars

S = 3200 / 22

S = 145.45 mm

Therefore,

Provide 22 bars of 16mm dia at 140mm spacing.

Check for One way shear stress

Shear force in the one way area = 0.95 x 3.2 x 195.3 kN

= 593.7 kN

Shear stress at one way cut face = tv = 593.7 x 1000 / (3200 x 450)

= 0.412 N/mm2

Shear capacity check as per IS 456-2000 table 19.

= 0.425 N/mm2

Design shear stress is less than capacity shear stress.

Hence okay.

Check for two way shear or punching shear.

Shear force in two way

= (3.2 x 3.2) – (0.85 x 0.85) x 195.3

= 1859 kN

Design shear stress at two way cut face

Tv = 1859 x 1000 / 3450 x 450

= 1.25 N/mm2

Check for shear capacity as per IS 456-2000 cl 31.6.3.1

= 0.25x √fck

= 0.25x √25

= 1.25 N/mm2

Design shear stress is less than shear capacity hence okay.

RESULT-

Provide a 3.2x3.2m footing with a depth of 500 mm.

Provide reinforcement of 20mm dia bars in both directions.

Provide anchorage for column and footing at 750mm.

AutoCAD design.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.