Challenge

Concept on positioning of Columns

Question 1:

Comment on the layout of the framing plan concerning earthquake resistance in the two horizontal directions X or Y (dots are columns, lines depict beams). Look into aspects of symmetry, redundancy and bi-directional stiffness and ductility.

Ans

Symmetry in X-direction

If we split the plan vertically half,it look mirrored

Here it is symmetric in x direction

Symmetry in Y-direction

If we split the plan horizontally half,it look mirrored

Here it is symmetric in y direction

Redundancy in X direction

The columns in x direction is comparatively more and evenly spaced

So the is redundant in x direction(except top and bottom rows)

Redundancy in Y direction

The columns in y direction is lesser and evenly spaced

The structure is redundant but less than x direction

Bi directional stiffness

The columns in horizontal direction are connected to straight to straight beams

Any lateral load passing from the left end will reach on right through straight path

Less possibility for force diversion takes place

The columns in vertical direction are not connected to straight to straight beams

The lateral load form south side divested to east and west side to reach end

So force diversion takes place in y direction

So the plan is weak in Bi directional stiffness in y direction

Ductility

From the plan it is clear that more columns are in x direction compared to y direction

It will result to high stiffness in x direction which reduces the ductility in x direction

The north south beams are arranged in zigzag which leads to discontinuous bracing

So the plan is more ductile in y direction compared to x direction



Question 2:

What are the possible sources of irregularity in the building shown here? Explain how, as an engineer, each of these irregularities should be dealt with.

Ans

Vertical irregularity

The building have large area in bottom stories than the upper stories

The floor plan area getting reduced by height

The building floor plan area is to be crosschecked with reference to IS 1893 2016 Table-6 serial number 3

Soft storey

The building has uncovered space in 6th floor

There is no occupancy and partition walls provided it will lead to plastic hinge formation at the columns

This has to be checked and designed with reference to IS-1893-2016 Figure 4A

Sloppy base

The building is constructed on sloppy ground at one side

It will leads to significant variation in stiffness

With reference to IS-1893-2016 Figure 5E slope should be avoided

Question 3:

A 4-storey hotel building has an open ground floor for the restaurant. Story 2 to 4 have one row of rooms along each long side in plan, separated by a corridor. The two short sides of the perimeter are fully in-filled in all storeys, except for certain openings at the ends of the corridor at storeys 2 to 4 and along the right-hand side of the ground floor. There is a staircase near the upper left-hand corner, with straight flights between landings at floor levels and in-between floors. Cross-section dimensions are written next to the member no. in meters.

Comment on the features of the structural design and of the layout of infills which are important for earthquake resistance and seismic performance. How do they relate to the almost full collapse of this building (the extreme left-hand bay with the staircase survived, as well as one long-side façade in the rear end, and the frame along the right-hand side in plan).

Ans

Hotel building has an open ground floor for the restaurant so it will result in soft storey mechanism in the ground floor of he building

Rooms along two bays is separated by open corridor the bays filled with rooms will have higher mass compared to the middle bay left open for corridors this lead to mass irregularity along height

Two short sides covered with infill walls .This means the buildings left and right side is more stiffer during seismic force.

Staircase portion at left top corner,usually staircase and elevators are stiffer than other elements because of concentrated concrete elements staircase portion will have more stiffness

No beam connections in Y direction.This will make building more vulnerable during North South seismic waves

Beams connected along column minor axis.The columns are having longer dimension in Y direction so it is more stiffer in y direction,but beams are running only along x direction which would attract lesser lateral force and hardly transfer it.

Variation in column size.The internal columns have heavier size than external columns but this will lead to significant difference in lateral drift of column,so the concrete floor