The Sample Building, Architectural Plans and Design Codes
A free lesson from Skill-Lync's Structural Design of Highrise Precast Buildings using ETABS course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Week 1 Session 3”
What will you learn in this free Structural Design of Highrise Precast Buildings using ETABS lesson?
The instructor presents the sample building: a ground plus 15 residential block in Kanpur with a 17 by 11 meter floor plate and a stilt parking floor. The lesson reads the architectural plans, then lists the codes used, including IS 456, IS 875, IS 1893, IS 13920, IS 15916 and FIB 14.
- Building parameters: location, floor heights, soil assumptions
- Reading architectural plans as a structural engineer
- Stilt floor as a soft or weak storey
- Indian codes and FIB 14 used for precast
What comes after lesson 3?
Later in Skill-Lync's Structural Design of Highrise Precast Buildings using ETABS course (paid): lesson 4, Week 1 Session 4; lesson 5, Week 2 Session 1; lesson 6, Week 2 Session 2. The full course has 56 lessons (22 h 56 min of video); see the course overview or its price and syllabus.
Lesson transcript
Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.
So now as we move towards the building that we will be taking for our course, for the structural design, as I have already told you in the earlier slides that we have covered, the building is going to be pre-cast building. The number of stories will be ground plus 15 and the building is almost completely pre-cast except the foundation part of it. The foundation would be cast in place concrete. Just to tell you, for all the floors that we have, there could be some parts of it which could be cast on site, maybe the top screed of it, screed topping that we will be having.
But apart from that, almost all of the things will be pre-cast and we will be covering design as well as the connection part of it. Now the next part that we have, that is the floor plate dimension for that particular building would be 17 by 11 meters. It is approximate that I have taken. So it's sort of a residential building that I have taken except there is for the lower first part of it, it's used as a parking. So there is certain restriction in terms of column placements and wall placements there. Otherwise, the floor plate that we have is of around 17 by 11 meters, 17 in one direction, 11 in the other direction.
Typically, on a typical floor, it's usually a residential architecture plant. We will be moving further and looking at those plants closely as we, in this particular slides only. If we see the location of the structure is Kanpur, how does it help to know the location of the structure? I think that is very much important when you are doing a structural design because you need to know the seismic as well as the wind loads that could come upon the building. So you are at least always required to know the structural location where is it located.
Further, if we talk about what is the soil bearing capacity? Soil bearing capacity has been assumed to be 150 kN per meter square. It's not like that that you could use this project, this capacity whenever you're working on a project near to the specified area. The actual SBC depends upon this geotechnical analysis done at the site. So for that, you need to coordinate to the client before starting with those calculations. If we talk about the soil subgrade modulus that we will be taking, that will be 10,000 kN per meter cube for our case.
Whereas, some of you would know that there is a slight relationship between the soil bearing capacity and the subgrade modulus, assuming the certain factor of safety. But here, we have directly chosen it to be 10,000 kN per meter cube. This, again, these two parameters will be used when we will be going on to the foundation design in the subsequent weeks. And if we see what exactly do we have, since we will be designing a raft foundation, maybe then we might be needing the subgrade modulus k.
Because of which we will be taking into this displacement or the thickness of soil into picture to actually have a more realistic behavior. If we talk about the floor height that we have in this particular building, the floor heights for this is going to be 2.7 meter for the stilt floor where we have the parking. And other floors, which is the 3 meters each, which is basically 14 floors above that we have will be 3 meters each that we have that we will be covering. So, that's the mostly idea of the building design that we have.
These are the basic parameters that one needs to know. There would be other also that you need to discuss at the very beginning. And I think those are things that is related to the what sort of structural system is there. Whereas, in this particular if we talk, those will be our way of doing the analysis. Like how, what structural system we are going to choose for our particular building. We will be talking more about these when we go on to the next weekly sessions. So, moving on to the next slide that we have.
So, here I have taken the plan of the building. And here you can see, as I was telling you, this is the parking area. So, only the staircase part of it is visible. The near area would be actually left for parking. So, this is the grid that you have. As you can see, I have marked the dimension of each and every grid, inches as well as meter. So, this is the lowermost plan where this area is used as parking. If we see the entrance of the building is somewhere over here, sewer line and the stormwater drain has been marked over here.
These are few details which help while deciding few of the detail at the plinth level. We might get to it when we get to the design. But as the structural engineer, you need to be aware of where the sewer line is placed, how the stormwater drain has been placed. Because, usually these are main concerns of an architect. But while working with a particular project, you should also be aware. One more thing, you can see that there is a plot entrance from here. So, the column location should be such that you do not place a column somewhere over here.
Because, if you place some column as per a structural framing somewhere over here, it is going to collide. Or, a wall, let us say you put a wall over there, you cannot do so. Because, there will be a gate. We will be having that as an entrance to the building over here. So, that is the mostly thing about it. If we talk about what ground floor parameters are, it will be a stilt floor. So, first of all, I would just want to tell you that some of you might know what exactly is stilt floor.
So, stilt floor is lowermost floor where you have the reduced wall length because it is being used for the parking. And, it is sort of a weak story or a soft story as well. Sometimes soft story also in your building. The concept of weak story or soft story is directly taken from IS 1893. We will talk about these as well at length when we get on to what exactly a weak story or a soft story is. Since, that stilt floor does not have any infill walls in between, which is since it is used for parking, apart from the column and the wall placement that you have, you cannot have the infill wall betweens.
Because, let us say if you have a column over here and a column over here, the in-between area cannot be filled with an infill wall because you are using that space as a driveway. Since, you cannot have that, the lateral stiffness of your building reduces, right? Whereas, above floor will be all residential floor. There, you will be having periphery walls which will be actually adding to the stiffness of the structural system which will make the structural system, I would say, more stiffer. I am not talking about the shear walls or the beam column system which is actually providing the lateral strength to the building.
I am talking about a little stiffness which we will be getting up because of the infill walls that we have. So, since, slower floor is not having any infill walls as compared to the floors above, this level becomes more prone to the deflections that can result from the seismic forces or rent forces per se. But, mostly towards these seismic forces. If we talk about the blade dimension that we have, again, 17 by 11 meters. If you look closely, this side which is maybe in the future, we will be talking this as X only because that's how we have oriented our building.
Y would be this. So, it will be, X will be 17 meters and Y will be 11 meters that will be following. We sometimes, we will, as of now, you can see that these are marked in fit and inches also. But, in our way of working as per the design and the analysis part of it, we will be sticking to the SI units. So, it will be only in meters that we will be dealing with mostly. Uses, as I already told you, this will be a parking floor.
We have chosen this to be a parking floor to make it slightly complicated in terms of how the column placements in the shear wall system needs to be thought upon. And, the flow rate that is there for this particular floor will be 2.7 meters. That is the architecture plan that we have at the ground floor level. If I move to the next slide now, there, we do have the architecture plan of typical floor 1. So, this is the typical floor plan 1. And, I just tell, I should tell you, the level 2 to level 7 is actually typical floor plan 1.
Which is basically, they have a certain sort of a residential flat which have a different architectural layout. And, the above architectural layout is different. So, in the last slide, we did study that how the parking layout is and how do we need to study that. But, if now, I think we should pay more heat to look at these architecture plan. So, I know some of you might have already worked upon these sort of plans as they might have worked upon us on a purely concrete cast and statue building.
But, again, I think it is very, very essential for any person who is starting up their career that they need to read the architectural drawing. They should know that how exactly it is, what exactly is meant by what. So, here, as you can see, the same staircase that we were seeing below, we can see that there is this lift lobby that is there. Then, there is a lift entrance that we have. And, then, at this place, we have a crossed weld staircase which is basically, it is not a dog-like staircase.
It is mostly, we have two steps here also. So, it is going somewhere like that. It starts from here and there are maybe 6, 7, 7 steps over here. Then, maybe 3 rise over here and then similarly 7 steps over here and gets you to the next level. It is something like that. The center core that is there, if we talk about the entrance to the flat that we have. At every level, we will be having an entrance to the flat from somewhere over here or essential part, something like this.
If you enter the room, there's a fire area, fire areas, nothing, just the common place that they have. Then they have lobby, there is first bedroom connecting, there's dressing for that and there is attached room for that. I know these things are more concerns to the architect, but at times, you will be thrown to questions related to that and you'll have to figure out a solution in that sense. Since along with the architectural features, we need to have that knowledge of basic architecture, how exactly it's working and what all parameters are there.
So you all should be aware that in toilet areas, in balcony areas, architects demand of the sunk that we need to have. Then how do we take care of the sunk when we are dealing with completely free car system? How do we attain that? We need to know that. And similarly, you should also know that when you're dealing with the institution building. But again, here we are looking more towards the architecture layout. If you look over here, here is the drawing area for the slide. There is another bedroom that we have.
There is this common toilet, which has an entrance from somewhere over here as well. And there is this drawing area and if you look, there is the kitchen in this area. There is this dining room and there is another big master bedroom of this is around 13 feet by 16 feet, very large in 16 feet by 16 feet and 10 inches, which is very, very large bedroom that they have. And also then there is a dressing attest and there is a toilet attest to it. So this is one big flat that they have on that level.
And also if you look closely, you have balconies on both sides along the X axis of the building coming out of the thing. So when I have taken this to be 17 meters, I think these areas are not included because floor plate, but the floor plate at this level is actually much, much bigger. So it is basically it also includes five feet from in both on both the sides of this balcony as well. Here is a utility area that you have where there is some space left for washing and all those things that are connected to the kitchen that you have.
If you look closely, there has been a shaft left over here onto which the most of the pipes must be passing through over here. Now, why are we looking at these things? You might be thinking is a structural engineer do I need to know that the answer is absolutely yes. Because while working with the structural system, when you are starting to place columns on those plants and when you are planning to what sort of structural system would be there, would I use that shear wall or would I use that shear wall?
What should be their idea and where all you should put those columns? Where all should you span your beams? Could you have a, like, let's say if in your system, if you place a column directly in front of this location somewhere over here. So that's not a feasible solution. Like architect right away is going to avoid or basically throw that solution out or any person, not in architect. Even let's say if you do a house owner, if you suggest that solution, that won't be a solution to work for.
So basically, with the structure, only purpose that we are pulling that we are making buildings, right? So it has to be in coherence with whatever the idea of the building is. So similarly, you need to place your column such that it actually, you can avoid as much as possible in terms of it's directly being exposed to a visible area. Same goes for a structural beam. If a beam is spanning from this wall or this column to this wall, then it will be a problem because it will be directly visible in the area.
So either the depth of the beam has to be less and it should cover within the fall ceiling. And if it's not, then maybe you can work out a solution. But let's say if you cannot avoid that, then there is no issue. Then you'll have to have that beam. But you should know all those things very prior before actually doing so. So this is one typical floor plan that we have. If we talk about that, it's a typical floor. Floor per dimension is 11 by 17 meters.
I tell you, these 5 feet I have not included. So you can include that as well. And it will be more than 17 meters or 10 feet is almost added. So that will be slightly at least around 19 meters or so. So users, if we talk about this completely residential, some areas are although common lobby and staircases, but other is actually residential only. And then we have mostly residential areas, bedrooms, washrooms, and then balconies. If we talk about the floor height, floor height for this would be 3 meters.
And the levels for which we have such plan is actually level 2 to level 7. So level 1st was the parking for us, level 2 to level 7, which makes around 6 levels. We have that as a pre-cast residential floor of this plan. If I move to the next slide that we have, next slide is the typical floor plan too. It is also a residential plan. It's just a bit varying in terms of the layout. So as you can closely see, this core, the staircase has not moved a bit.
It's at the same place as coming as it should not, right? One cannot take the staircase there and there. Although architects sometime do work out that sort of amazing plans and or so. But again, in terms of vertical continuity of the load that is getting down because of the vertical loads that we have, we need to know that the load path is as simple as possible. I must tell you, whenever you're working in a building, it's very essential that the load path that you have thought for, be it for gravity load, be it for any later load, it needs to be very simple, at least in your brain.
And then you should be able to sketch it out with a basic frame system or basic structural system that you've thought on. And then how can you actually articulate the same in that architecture plan that you have. So now let's get on to this architecture plan for typical floor level 2 that we have. Although similar, but there we had a directly bathroom over here or near to the foyer area after this. But here you actually have a drawing area at this place and here we have a big bedroom and there is a kitchen and there is another bedroom.
There is another toilet and there is one more toilet. This is a common toilet and this is an attached toilet. That was a single flat on that particular floor having three rooms. Here it's one architectural layout like this, where it has two bedrooms, one attached bathroom and one common bathroom. It has a drawing area as well as the kitchen is there and there is one balcony. And the other half of the floor bed is actually left for a penthouse. So here actually, if you can see, these are actually two story villas, which is basically two stories will be combined within.
And if you can see over here, you can see a staircase within a flat. This is one unit of a flat and here is another unit of the flat. Here you can see the staircase within. So your answer should be in an architect meeting when you're sitting that how come in a flat system, we are actually having a staircase within our flat. It's within a one residential unit. But the thing is, if we talk about this unit, the floor above also and floor below also would be one unit.
So basically, two floors comprise of one unit and combining both, we will be having one bedroom, a toilet, a drawing area somewhere over here. And above this, if we look there, you'll be having one more bedroom over here and another bedroom over here. So that's the idea behind it. That's all have been thought upon. Similarly, we'll have to work with that system. Our idea would be to choose a system which can work with this sort of structural plan or a plan. If we look now, I think this is again typical floor plan.
The floor dimension is similar. 11 meters by 19 meters more or less. You can say the 1.5 meters may be coming because of the extension of balconies that we have. But here the essential difference that we have from the plan that we were seeing earlier. The typical floor plan 1 is actually, it has two flat units whereas it had only one. So that's the idea behind it. So if we talk about two floor for this, this will be one flat and above this, there will be another separate flat.
But this will be a common villa sort of penthouse sort of a thing spanning between two floors. So that is the idea behind it. This floor would have access from two levels. That's the idea behind it. And if we talk about level 8 to level 13 is actually, which is again what six levels would be gone in this typical floor plan 2 that we have. And above that, we'll be having another level which will be roof in our case. If I go back again to a comparison, as I told you, this is a one complete flat.
That you cannot see a full wall architectural separation between these two. But if I move to the floor plan 2, which I had from that slide, it is again a separation, a close complete separation. No window, no nothing. So there is actual separation between these two. That's more about the building that we'll be using and we'll be designing. Taking it to be a pre-caste building, it's going to be a 15 floor building. First floor would be the parking level 2 to level 7. That is a six more floor we have that is typical floor plan 1.
After that, we have six levels of typical floor plan 2. After that, we'll be having a roof level and maybe a... Level at the level above the level. Yeah, so that's mostly the bit and next we move to the next slide that we have. So this was mostly on to the whatever we are going to do in this particular course that we have, right? So just the beginning, we will be diving more deep into the architecture plan that we have and thinking about the structural system we need to choose for the loads that we have.
All those things we will be covering those mostly the gist of it. But now let's get on to the course that we will be covering. So at the very beginning, I told you that the we will be going through just mentioning what course that we will be covering in this particular complete 12 session course. So we will be using Indian structural course, the complete course has to be done as per the Indian structural course that we have. We might be using few references from above related to precast.
But whenever I use such references, I'll just keep you updated. That's what we are using. So we will be using IS456, the Indian code for plain and reinforced concrete code of practice, which actually tells you what strength parameters, what material safety parameters, what checks for flexure, what checks for shear, what checks for compression, what all things you need to take care of while working with concrete as a material that you have. Then we will be following IS75 part 1 to part 5 to take care of the loads that we have in our building.
So as you must, some of you might know, some of you might not know that part 1 covers the head load that we have from various type of material that we have, it specifies the density and all this part 2 covers the impulse loads. The part 3 covers the snow load and the part 4 covers the wind loads. Similarly, for earthquake, it's not covered in IS875. We have a separate code for that to deal with the seismic because in India, the seismicity has been very well prominent issue, especially in some areas.
So at least there has been a separate code to deal with IS that is IS 1893. There is a criteria for earthquake resistant design of the structure. We will be also closely looking at IS 1893. And there is again IS 13920, which actually ensures the ductile detailing of the reinforced concrete structure subjected to seismic forces. So since non-linearity in terms of geometry in our building, it's mostly taken care of at the in the IS 13920 in our building, whereas the dynamic nature of the forces is actually taken care of by IS 1893.
But the non-linearity we have in our building is actually taken care of by IS 13920. So I must tell you, since we'll be starting on this course, you should at least brush up your knowledge that you have of these codes. If you don't have, don't worry, we'll be covering whatever we are going to need. We will be covering in a particular course that we have. But still, if you have some knowledge and if you develop the curiosity, you should go and actually look at the structural codes that we are going to use at these.
Again, I think whatever you do as a study, it will be useful for the sessions of other sessions. I had if I move to the next slide that we have now what course will be referring to for this in terms of precast. So we did talk about what we'll be referring in terms of whatever we know. We know in terms of loads, we know in terms of seismic criteria, what we'll be following, what in terms of complete design, what we'll be following. So there is a specific code for precast also in as per Indian standard, that is IS 15916.
Building design an erection using prefabricated concrete. Although it's very small code in terms of number of pages, but it talks a lot in terms of how precast buildings to be dealt with. Although in India, it's still catching up in terms of standardization and code of practice that one needs to follow. But still, I must say that this code is very helpful when you're doing the design. Although at times you'll have to fetch some references from some research papers that you're working or maybe some other foreign codes.
But at least this code that we have, the IS 15916 is also useful. We'll also be taking in help of FIB 14, which is again, bulletin 43 from the structural connection for precast concrete buildings. It will be helpful in terms of getting the few of the connections that we have taken here. In Indian codes, the structural connections is actually left for your liberty as per what you want to design as in. It has to follow certain criteria though, but actually what type of connection you want to choose, there is not much information there.
So, but here I must say FIB 14 would be, we'll be fetching few connections from there. And I think in precast, structural connections are the most critical thing that one needs to work upon because the building is not monolithic and constructed in one go with beam and columns constructed together. So, the connections that you have between those elements, between any element, become very, very critical. So, this is the end for the session three, week one. So, this is the end for the session three, week one.